HomeMy WebLinkAboutPLANS4' C.O.T.G. ASSUMED LOCATIODN� OF EXISTING 4' BUILDING SEWER PIPE I♦/ NIPS ,nAG 0 EXISTING BEDROOM EXISTING BATHROOM EXISTING BEDROOM ORIGINAL 200 AMP IAIN LUG (;IRCUIT BREAKER PANEL EXISTING FAMILY ROOM EXISTING 1 STORY C.B.S. HOUSE zm ❑ N z X Q W J STING CHEN "�— ASSUMED LOCATION OF EXISTING — — HOUSE BUILDING DRAIN (SOIL/WASTE DRAIN PIPE) BELOW CONCRETE FLOOR SLAB F—� EXISTING DINING ROOM EXISTING MASTER SUITE 1 I Im- �[vmkw MAIN ENTRANCE A" MASTER BATHROOM REMODEL LOCATION PLAN SCALE: 1/8" =,'-o" GENERAL PLUMBING LEGEND AND ABBREVIATIONS -----EBS----- ASSUMED LOCATION OF EXISTING BUILDING SEWER — - - —ES — - - — ASSUMED LOCATION OF EXISTING BUILDING DRAIN (SANITARY SOIL/WASTE DRAIN PIPE) VTR APPROX. LOCATION OF EXISTING SOIL/WASTE PIPE VENT RISER UP ABOVE CEILING (AND THRU ROOF WHERE NOTED VTR) RENCE NOTE: 1. ORIGINAL PERMITTED HOUSE CONSTRUCTION PLANS WERE NOT OBTAINED OR REVIEWED BY THE E.O.R. AND ACTUAL LOCATION OF EXISTING WATER SUPPLY PIPING (HOT & COLD) AND SOIL/WASTE DRAIN PIPE AND VENT RISERS COULD NOT BE FULLY VERIFIED BY ON -SITE INSPECTION PERFORMED MAY 24, 2019. 2. THE LOCATION OF EXISTING HOUSE SANITARY WASTE AND SOIL/WASTE DRAIN PIPE, SHOWN IN THESE PLAN IS DIAGRAMMATIC ONLY, FOR PURPOSES OF ASSUMING LOCATION OF WASTE DRAIN PIPE AND WATER APPLY PIPING ASSOCIATED WITH THE BATHROOM REMODEL. 3. CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE EXISTING SANITARY WASTE, SOIL/WASTE DRAIN PIPE, AND COLD (& HOT) WATER SUPPLY PIPING IN THE VICINITY OF THE BATHROOM AND MAKE NECESSARY PIPE ALIGNMENT ADJUSTMENT AS NEEDED TO PROVIDE SERVICE TO REMODELED BATHROOM PLUMBING FIXTURES AND CONNECT TO ORIGINAL HOUSE WASTE DRAIN PIPE AND HOT & COLD WATER SUPPLY PIPE. EXISTING DINING ROOM (FLOOR TILE) CLOSET I,\ eq ❑ EXISTING W.I.C. `, xi 9 (CARPETING) , $, N� 2V' VRC O 1 LINE OF SOFFIT/SHELF ABOVE WITH RECESSED LIGHTING FIXTURES EXISTING MASTER BEDROOM (CARPETING) EX 2668 P.D. Lo TILE EXISTING W.I.C. EXISTING MASTER BATH CEILING HEIGHT = 9'-11 % (AFF) (13"x13" CERAMIC FLOOR TILE) EXISTING ELECTRIC WATER PUMP ,V-3%" I. 3'-OX2" 1 7'-OY4' EXISTING FINISHED BATHROOM LENGTH (CARPETING) EXISTING PLUMBING WALL FEXISTING 11¢" VRC EX. 53" x73' SH ( SILL HEIGHT =24"AFF) 5'-1 EXISTING MASTER BATHROOM PLAN SCALE: 3/8" _,'-O" .I : _ z*r14 21 o _- II7 _ .GI=i'I F-1 1 lO— DEMOLITION WORK IDENTIFICATION NOTE A�- NEW REMODEL CONSTRUCTION IDENTIFICATION NOTE EXISTING 8" CMU EXTERIOR HOUSE WALL 3/4" FURRING & 1/2 G.W.B. INTERIOR AND CEMENT STUCCO FINISH EXTERIOR EXISTING INTERIOR 2x4 STUD PARTITION WALL 1/2" GYPSUM WALLBOARD INTERIOR (NON -BEARING, U.N.O.) L DIM. I. EXISTING FIELD MEASURED DIMENSION LINE DIM. BATHROOM REMODEL CONSTRUCTION DIMENSION LINE TO FINISHED G.W.B. SURFACE EX.2668 EXISTING INTERIOR DOOR MARK DOOR SIZE: 2'-6"W x 6'-8"H (OPENING) NOMINAL H.C. HOLLOW CORE (DOOR TYPE) B.F. BI-FOLD (DOOR TYPE) P.D. POCKET DOOR (DOOR TYPE) S.G. SAFETY GLAZING (IN DOOR OR WALL PANEL) (PER CPSC 16 CFR PART 1201, CATEGORY I OR II) D.O. DOOR OPENING R.O. ROUGH OPENING G.W.B. GYPSUM WALLBOARD SHEATHING U.N.O. UNLESS NOTED OTHERWISE AFF ABOVE ORIGINAL/FINISHED FLOOR SURFACE/CARPETING AFS ABOVE NEW FINISHED TILE SURFACE CONT. CONTINUOUS VTR SOIL/WASTE PIPE VENT THROUGH ROOF VRC SOIL PIPE VENT RISER UP TO RE -VENT ABOVE CEILING M.C. MEDICINE CABINET O 0 x r a 4 m 0 in x N z LL 0 Z F (n X w C � 4 M u C M 0D PMh z c tV 3 0 _ N v C) CC z _ v ❑- c E CD C L �C 3 Lycc N 0 a c o a (' L 1 C v o`Aj3 Q. Z Q v v_ L � 04 M ¢ " k FILE COPY l pl(gl�� REVIEWS FOR CODE COMPLIANCE ST. LUCIE COU TY BOCC IMt �EC��ED JU( Q $ 2019 PBpm(H(np Luau 8�' LuC(e COun(v SCANNED St. Lucie • U V w V ?� /0 F••1 h � � � N W0 U O U ] a 0 Be a y (n N m N O] Of r O U1 e` Z 0 O V� C3 En W li Z z 1 LU 0 no Z J W W U) ® Ili fe (j) O R V CM® 4) C L1. ' :a ® > 0• L" m O ''5^^w_ V Z V = M E V OO d 0 N d M W J (/� U) W ad Iwo c Timothy C. Boudah 514 S.W_ PSL. Blvd. Port St. Lucie, Pl. 3495 P.E_ No. 63179 Date: v �/ SCALE: AS NOTED JOB NO.: 1319.0525 Al SHEET 1 OF 5 EXISTING MASTER BEDROOM (CARPETING) EX 2668 P.D. CLOSET } F\-----3 < d Q z o EXISTING W.I.C.; `.co ; _ U (CARPETING) i i $, Xa c Ld EXISTING DINING ROOM (FLOOR TILE) TING MASTER (CERAMIC FLOOR TILE) APPROX. SLAE SAW CUT LINE 0 ra EXISTING W.I.C. (CARPETING) PLUMBING WALL OPEN WALL TO EXPOSE EXISTING DRAIN PIPE & WATER SUPPLY PIPE AND INSTALL NEW DRAIN & WATER SUPPLY PIPE IN WALL TO SERVE NEW VANITY SINK EXISTING DRAIN PIPE & H/C - WATER SUPPLY PIPE (IN WALL) CLOSET EXISTING W.I.C. (CARPETING) EXISTING DINING ROOM (FLOOR TILE) y EXISTING MASTER BEDROOM (CARPETING) EX. 268E P.D. } Q —T I 0 J Q Z F I I N. 1 AT t7 m 0, 1 1— .U.Ld O § n EXISTING W.I.C. (CARPETING) i INSTALL NEW VANITY BASE - ----------- '`------ ---�__ AWER CABINETS, SINK AND 24- LBBAAK y W siNK BABE z4 9AKAWEB 1Y (BAOB�A6EB COUNTERTOP RENOVATED MASTER BATH F D (NEW PORCELAIN FLOOR TILE) ------ INSTALL TILE THRESHOLD FOR TRANSITIONS INTO SLOPED SHOWER FLOOR //// SHOWER RAIN HEAD 076'AFS� _ — INSTALL NEW TOILET NEW TOILET PAPER I PLUMBING WALL TE& CONNECT TO EXISTING WAR SUPPLY & DRAINAGE AND NA TALL NEND W BATH ASSEMBLYFILLER RA Ill RNIA FA •ON ON / I IE, rPA PA I- --70 - EX. ST x73" SH INSTALL NEW 24"x 36" LONG ( SILL HEIGHT =24"AFF) PVC LINEAR FLOOR DRAIN W/ -O' 2'-0" 316 S.S. DIAMOND PLATE STRAINER MAX. INSTALL NEW TILED SHOWER 1 SEAT (24"X24"X18"H) 4V A2 4X" 3'-5" V-0" 7'-10%t" DEMOLITION PLAN FINISHED BATHROOM FLOOR PLAN SCALE: 3/8" = 1'-0" SCALE: 3/8" =1'-0" SEE SHEET A-4 FOR ELECTRICAL MODIFICATION PLAN GENERAL DEMOLITION NOTES 1. ELECTRICAL, A. ISOLATE ALL ELECTRICAL LIGHTING AND POWER CIRCUITS AS NEEDED TO PERFORM PROPOSED DEMOLITION WORK. MAIN ELECTRICAL PANEL IS LOCATED IN GARAGE. B. ALL EXISTING ELECTRICAL LIGHTING AND POWER CIRCUIT WIRING TO BE PROTECTED IN -PLACE AND REUSED. C. ALL EXISTING ELECTRICAL CIRCUITS TO BE REUSED. NO NEW ELECTRICAL CIRCUITS REQUIRED FOR PROPOSED REMODEL WORK. D. ELECTRICAL LOAD CALCULATIONS ARE NOT REQUIRED AS THERE WILL BE NO INCREASE IN ELECTRICAL SERVICE CIRCUITS OR ELECTRICAL POWER LOAD. 2. HEATING, VENTILA11ON & AIR-CONDITIONING: A. BATHROOM REMODEL WORK WILL NOT AFFECT A/C SUPPLY AIR DUCTS, SUPPLY AIR REGISTERS, RETURN AIR GRILLES, AND WILL NOT AFFECT EXISTING H.V.A.C. SYSTEM. BATHROOM DEMOLITION WORK VENTIRCATION NOTES - STING WALL PAPER COVERING: - REMOVE EXISTING WALL PAPER THROUGHOUT MASTER BATHROOM. EXISTING CEILING SOFFIT: 2 - REMOVE EXISTING CEILING SOFFIT AT BATHROOM ENTRY. - REMOVE EXISTING VANITY LIGHT FIXTURES; CIRCUIT WIRING TO BE PROTECTED -IN -PLACE AND REUSED. EXISTING FLOOR TILE: 3 - REMOVE ALL EXISTING WOOD BASE BOARD MOLDING WITHIN THE BATHROOM. - COMPLETELY REMOVE ALL EXISTING FLOOR TILE WITHIN THE BATHROOM. - CLEAN AND PREPARE EXIS71NO CONCRETE FLOOR SURFACE TO RECEIVE NEW PORCELAIN FLOOR TILING. EXISTING VANITIES (2): - REMOVE EXISTING SINK FAUCETS, VALVES, AND FIXTURES. - TEMPORARILY SHUT OFF/CAP HOT & COLD WATER SUPPLY LINES AND DRAIN PIPE TO EXISTING SINK 4 (PROTECT IN -PLACE FOR REUSE). - REMOVE EXISTING BACK SPLASH AND COUNTER TOPS. - REMOVE EXISTING VANITY BASE CABINETS AND OPEN UP G.W.B. WALL SHEATHING TO EXPOSE EXISTING HOT & COLD WATER LINES, AND WASTE DRAIN PIPE, FOR EXTENSIONS TO NEW VANITY LOCATIONS. EXISTING JACUZZI TUB: - REMOVE EXISTING WHIRLPOOL TUB. - REMOVE EXISTING TUB FAUCET VALVE AND FIXTURES. - TEMPORARILY SHUT OFF/CAP WATER SUPPLY LINES AND PLUG TUB DRAIN PIPE (PROTECT ALL 5 ROUGH PLUMBING FOR REUSE). - REMOVE EXISTING HYFLO PUMP AND PUMP PIPING. - REMOVE EXISTING WALL MOUNTED ELECTRICAL RECEPTACLE; CIRCUIT WIRING TO BE PROTECTED AND REUSED. - REMOVE EXISTING TUB FRAMING, TO EXPOSE WALL AND CONCRETE FLOOR. - REMOVE EXISTING PUMP HOUSING WOOD FRAMING. - REMOVE EXISTING WALL MOUNTED TIMER SWITCH ASSOCIATED WITH WHIRLPOOL PUMP. EXISTING SHOWER STALL: - REMOVE EXISTING GLASS SHOWER DOOR, DOOR FRAME AND HARDWARE. - REMOVE EXISTING SHOWER FAUCET VALVE AND FIXTURES. 6 - TEMPORARILY SHUT OFF/CAP WATER SUPPLY LINES AND PLUG SHOWER DRAIN PIPE (PROTECT ALL ROUGH PLUMBING FOR REUSE). - REMOVE ALL EXISTING FLOOR TILE, AND WALL TILING. - REMOVE SHOWER BASE AND UNDERLING BASE MATERIAL AND ALL CURB CONSTRUCTION FLUSH TO ORIGINAL CONCRETE FLOOR SURFACE. - SAW CUT THROUGH EXISTING CONC. FLOOR SLAB WITHIN PERIMETER INTERIOR LIMITS OF NEW SHOWER FLOOR AREA AND REMOVE CONCRETE SLAB (APPROX 5'-6" X 3'-64) EXISTING TOILET: - REMOVE EXISTING TOILET, COVER & PROTECT DRAIN FOR INSTALLA110N OF NEW TOILET. - MODIFY EXISTING HOT & COLD WATER COPPER PLUMBING LINES AT EXISTING VANITY TO REACH NEW CENTERED PLACEMENT OF BATHROOM SINK FAUCET. INSTALL WATER HAMMER VALVE ON HOT & COLD WATER SUPPLY PIPE, IF NEEDED. - INSTALL NEW OR RELOCATE EXISTING PVC DRAIN PIPE AT EXISTING VANITY SINKS. A SEE PLUMBING MODIFICATION PLAN - INSTALL NEW FLOOR MOUNTED VANITY BASE CABINETS, COUNTER TOPS, BACK SPLASH, AND SINK BOWLS. - INSTALL NEW CODE APPROVED COLD (& HOT) WATER SUPPLY FIXTURE FAUCETS IN STRICT CONFORMANCE WITH FAUCET FIXTURE MANUFACTURER'S INSTALLATION INSTRUCTIONS. - INSTALL NEW WALL MOUNTED MIRRORS AND BATHROOM FlNISHINGS PER HOMEOWNER'S SPECIFICATIONS. - EXPOSE EXISTING DRAIN PIPE & INSTALL NEW DRAIN PIPE FOR NEW 71" SAUNDERS FREESTANDING TUB W/ FLOOR MOUNT TUB FILLER (DELTA MODEL T4759-FL-LHP) B - INSTALL NEW TUB FILLER IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND CONNECT TO EXISTING DRAIN PIPE AND WATER SUPPLY PLUMBING. - FINISH WITH PAINT/TILE PER HOMEOWNER'S PREFERENCES. - EXPOSE AND MODIFY EXISTING SHOWER CONTROL VALVE PIPING HOT & COLD WATER COPPER PLUMBING LINES TO EXTEND PIPING UP THRU INTERIOR WALL FOR HAND HELD SHOWER CONTROL VALVE AND NEW RAIN HEAD SHOWER. - REMOVE EXISTING SHOWER DRAIN. SAW CUT AND REMOVE CONCRETE SLAB TO INSTALL LINEAR SHOWER DRAIN WITH PVC DRAIN PIPE CONNECTION TO EXISTING SHOWER DRAIN PIPE. SEE PLUMBING MODIFICATION PLAN - POUR NEW 3W THICK MIN. CONCRETE FLOOR SLAB TO FORM SHOWER FLOOR. SLOPE NEW SHOWER FLOOR TO DRAIN AT MAX )r PER FOOT. TROWEL APPLY LIQUID WATER PROOFING MEMBRANE FOR THIN -SET. TILE FLOORING WITH THRESHOLD TILE AT SHOWER ENTRANCE. - INSTALL )r CEMENT BOARD ON WALLS AND TILE SHOWER IN ACCORDANCE WITH HOMEOWNER'S PREFERENCES. INSTALL TWO HANDICAP GRAB BARS AS SHOWN ON PLAN. - CONSTRUCT NEW 24"X24" SHOWER SEAT AT 18" HIGH AFS. - INSTALL �e FULLY TEMPERED SAFETY GLASS WITH ALUMINUM TRIM MOUNTED TO WALL &KNEE WALL 7FT. MINIMUM HEIGHT ABOVE FINISHED FLOOR. INSTALL NEW TOWEL BARS AT EACH SIDE OF MASTER BATH AS SHOWN ON PLAN. �[ INSTALL NEW WATER CLOSET AND TOILET PAPER HANGER IN ACCORDANCE WITH HOMEOWNER'S PREFERENCE. INSTALL NEW PORCELAIN TILE THROUGHOUT MASTER BATHROOM. FINISH, PAINT, AND ADD BASEBOARD ACCORDING TO HOMEOWNER'S PREFERENCES. Fl_t. n EXISTING DRAIN PIPE & H/C WATER SUPPLY PIPE IN WALL TO REMAIN FOR REUSE INSTALL NEW VANITY BASE CABINETS, SINK AND COUNTERTOP NEW 24" HIGH 2x4 FRAME KNEE WALL WITH FULLY TEMPERED SAFETY GLAZING 5' HIGH (MIN.) EINSTALL NEW 71" SAUNDERS ACRYLIC FREE STANDING TUB WITH FLOOR MOUNT TUB FILLER SHOWER FIXTURE LEGEND: �-- HORIZONTAL 24" LONG GRAB BAR, 1)fO MAX. (1Y4"A MIN.) �J MOUNTED CENTERLINE 0 36" AFS — VERTICAL 18" LONG GRAB BAR 14"0 (14-0 MIN.) �1 MOUNTED WITH BOTTOM CENTER 0 39 AFS �- H/C WATER SUPPLY VALVE FAUCET �! MOUNTED 42" AFS - HAND HELD SHOWER WAND W/ H/C WATER SUPPLY VALVE BASE MOUNTED 0 38" AFS EXISTING HOUSE 8" CMU EXTERIC WALL ON MONOLITHIC POURED PERIMETER FOOTING/FLOOR SLAB (ROLL -IN ACCESSIBLE SHOWER) ci c� M M C O _I L� M ai � J M cV Q N v U a CL v _ W J L N a 0 w O W LLJ L. CI_ Q z o 04 ro rn AND REMOVE EXISTING CONC. FLOOR POUR NEW SHOWER FLOOR 4" MIN. ABOVE TILE THRESHOLD (TYPICAL ALL SIDES) LIQUID TYPE TROWEL APPLIED THIN -BED WATE PROOFING MEMBRANE REDGARD OR EQUAL CONFORMING TO ANSI A116.10 THRESHOLD (PH ACCESSIBLE) -NEW PORCELAIN FLOOR 11LE MAX' / 'EXISTING BATHROOM FLOOR SLAB LINEAR FLOOR DRAIN POUR NEW CONCRETE FLOOR SLAB (3r THICK MIN.) OVER PREPARED COMPACTED SUB -BASE WITH VAPOR BARRIER OVER TERMITE CHEMICALLY TREATED SOIL SCALE: 318" _ REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC • W a U � � m W z F v o/� M rn a Q >� L' U U o z a = CL Lo rn cliao BO ~ Y ~ rn tali n Is e Z oO C) n-a N" W W � GC 0 Z I z 1w I V a Z J W G W — Vi ® `0M uj V O 4) M v / LL LL m O JO ?�% Z O € =j M O O m G1 G 04 v/ yU) i C W ad -- I.L I q i i i 7 S " Timothy C. l3oudah 3 514 S.W. PSL. Blvd. Port St. Lucie, Fl. 34953 F P.E. No. 63179 0 2 y n n r � Date z SCALE 3 AS NOTED JOB NO.: F 1319.0525 J r A-2 SHEET 2 OF 5 EXISTING MASTER BEDROOM (CARPETING) IX 2689 PD. I � I I J J i EXISTING W.I.C. N = W f/1 ASSUMED LOCATION OF EXISTING n (n HOUSE - BUILDING DRAIN 57< (SOIL/WASTE DRAIN PIPE) I Ld BELOW CONCRETE FLOOR SLAB I EXISTING 2Y1" VTR wl EXISTING DINING ROOM (FLOOR TILE) , �f I I I EX.3" SOIL I DID N EXISTING W.I.C. m EXISTING PLUMBING WALL EXISTING 1X' EXISTING 1Y4" WASTE & P-TRAP tYi WASTE & P-TRAP 0 5=yASTE 0 S=Y4�/FT. (MIN.) TO BE (MIN.) VANITY FOR RELOCATED TO CENTER OF 0 -- REUSED FOR INSTALLATION MASTER SINK MASTER BATH INSTALLATION OF NEW SINK —NEW 2" W/D PIPE & P-TRAP FOR LINEAR SHOWER DRAIN SLOPE = Y4'/FT NSTALL NEW 1X" O5 I WASTE & P-TRAP II �, FOR NEW TUB L X. 2" WASTE _ — _ ° — & P-TWAP7 — - APPROX. LIMIT OF EXISTING EX. 1)z" WASTE D CONC. FLOOR SLAB REMOVAL RISER PIPE FROM BENEATH SLAB © REMOVE EX. 1 WASTE & -TF DRAIN PIPE WDV PLUMBING MODIFICATION PLAN SCALE: 3/8" = 1'-O" EXISTING 1Y4'VANITY TO BE REMOVED lY4 111 EXISTING-'--��` EXISTING 3" solL �, DINING ROOM EXISTING WC � ` l/ i W NEW SHOWER EXISTING ASSUMED LOCATION OF EXISTING 2 1/2" PVC VTR HOUSE BUILDING DRAIN (BELOW CONCRETE FLOOR SLAB) EXISTING MASTER SUITE ---------------- 1)5" VRC -� / I I EXISTING 1)j" VRC I / I I VANITY NEW 1Y4' 1Y4" ---------- 2"EWD ------+ -------7l�- -I 1 Y4" • EXISTING 1Y4' VANITY TO BE REUSED NEW LINEAR SHOWER DRAIN 2" W/D PIPE W/ TRAP REMODELED BATH DRAIN, AND NEW lY2" TUB TUB OVERFLOW PIPE J TUB ��NEW 1X" TUB DRAIN PIPE & P-TRAP rH A EXISTING TUB DRAIN & P-TRAP DIAGRAM SCALE: NTS PLUMBING LEGEND and ABBREVIATIONS 1a— NEW PLUMBING MODIFICATION IDENTIFICATION NOTE EWD EWD EXISTING WASTE DRAIN PIPE C.O.T.G.(E) ---4- +— EXISTING BUILDING DRAIN/SEWER CLEAN OUT TO GRADE ------ WD WD NEW WASTE DRAIN (WD) PIPE (SIZE PER PLAN) NEW WASTE DRAIN PIPE WITH TRAP WASTE PIPE TRAP ce — RISER PIPE DOWN �— RISER PIPE UP PIPE TEE PIPE ELBOW VTR SOIL/WASTE PIPE VENT THROUGH ROOF VRC SOIL PIPE VENT RISER UP TO REVENT ABOVE CEILING W/D WASTE/DRAIN PIPE C.O. CLEAN OUT W.C.WATER CLOSET (TOILET) BATHROOM PLUMBING MODIFICATION WORK NOTES - VANITY SINKS WATER SUPPLY PLUMBING: 1 - EXISTING VANITY SINKS HOT & COLD WATER SUPPLY PIPES TO BE CAPPED, DISCONNECTED, AND/OR RELOCATED AS NOTED IN DEMOLISH PLAN/ WORK IDENTIFICATION NOTE #4. SHOWER WATER SUPPLY PLUMBING: - REMOVE TILE, SAW CUT AND REMOVE CEMENT WALL BOARD SHEATHING TO EXPOSE EXISTING SHOWER HOT & COLD WATER SUPPLY PIPES. 2 - TIE INTO EXISTING WATER SUPPLY PIPES WITH NEW 3/B"0 (MIN.) COPPER HOT & COLD WATER DISTRIBUTION PIPES. WATER SUPPLY TO BE PIPED WITHIN EXISTING WALL TO NEW HAND HELD SHOWER HEAD AND INTO CEILING TO SUPPLY NEW RAIN HEAD SHOWER. TUB WATER SUPPLY PLUMBING: 11E INTO EXISTING HOT & COLD WATER SUPPLY PIPES TO CONNECT TO NEW TUB FILLER. VANITY SINKS WASTE DRAIN RISER -PIPES: - SAW CUT AND REMOVE GYPSUM WALL BOARD SHEATHING TO EXPOSED EXISTING VANITY SINKS W/D RISER -PIPE. 4 - MODIFY EXISTING W/D RISER -PIPE, ELBOW, AND HORIZONTAL W/D PIPE SECTION, AS NEEDED, TO INSTALL NEW SCHED. 40 PVC W/D PIPE TRANSITION FITTINGS TO DEVELOP W/D PIPE ALIGNMENT TO BOTH NEW VANITY SINK LOCATIONS. SHOWER WASTE DRAIN PIPES: - SAW CUT AND REMOVE EXISTING CONCRETE FLOOR SLAB WITHIN LIMITS OF NEW SHOWER STALL AND EXCAVATE SOIL FROM EXISTING SHOWER DRAIN PIPE TO NEW LINEAR SHOWER DRAIN. - INSTALL NEW SCHED. 40 PVC W/b PIPE (MATCH EXISTING W/D PIPE SIZE) WITH PIPE SLOPE GREATER THAN 1/4-INCH 5 PER FOOT OF PIPE - INSTALL 45 DEG. PIPE ELBOWS TO ASSEMBLE VERTICAL DRAIN PIPE UP THROUGH SHOWER FLOOR AND INTO BOTTOM OF LINEAR DRAIN. - WRAP W/D RISER PIPE, OR PLACE RISER IN PIPE SLEEVE, WHERE W/O PIPE PASSES THRU CONCRETE FLOOR SLAB, AND SEAL PIPE WRAP, OR SLEEVE, WITH NON -CORROSIVE CLAMPING RING DEVICE TO ELIMINATE ANNULAR SPACE BETWEEN PIPE AND SLEEVE, IN CONFORMANCE WITH FBC-R, SECTION P2603.3.1. TUB FLOOR WASTE DRAIN: 8 - INSTALL NEW 71" SAUNDERS ACRYLIC FREESTANDING TUB IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. - EXCAVATE CONCRETE FLOOR AS REQUIRED TO CONNECT NEW 1V W/D DRAIN RISER PIPE TO EXISTING PIPE BENEATH CONCRETE SLAB FLOOR. CONCRETE SLAB REPAIR WORK NOTES: 1. PLACEMENT OF CONCRETE SHALL NOT COMMENCE UNTIL CERTIFICATION OF TERMITE PROTECTION SOIL TREATMENT IS OBTAINED FROM A QUALIFIED PROVIDER IN ACCORDANCE WITH PROVISIONS OF THE FBC-RESIDENTIAL, SECTION R318.1. 2. FOLLOWING PLACEMENT OF CHEMICAL SOIL TREATMENT FOR TERMITE PROTECTION, COVER COMPACTED SUBGRADE WITH 6 MIL (MIN.) POLYETHYLENE (OR CODE RECOGNIZED CLASS I VAPOR RETARDER). 3. CONCRETE USED TO RESTORE BATHROOM SHOWER SLAB/PIPE TRENCH, MAY CONSIST OF HAND MIXED PRE -MIX CONCRETE CONSISTING OF TYPE II CEMENT, THAT CAN PROVIDE A HIGH EARLY STRENGTH =3500 PSI (MIN.) COMPRESSIVE STRENGTH 0 7 DAYS (4000 PSI 0 28 DAYS), SUCH AS "QUIKRETE" 5000 CONCRETE MIX, PRODUCT #1007, OR SAKRETE HIGH STRENGTH CONCRETE MIX, CONFORMING TO ASTM C387, OR EQUAL 3. CONCRETE MUST BE MIXED AND CURED IN STRICT ACCORDANCE WITH PRODUCT MANUFACTURER'S WRITTEN INSTRUCTIONS. 4. CONCRETE MUST BE ALLOWED TO CURE FOR A MINIMUM OF 7 DAYS BEFORE LOADING CONCRETE SURFACE AND A MINIMUM OF 14 DAYS BEFORE SETTING THIN -SET MORTAR FOR PLACING NEW PORCELAIN FLOOR TILING. EXISTING 1/2"0 COPPER (HOT & COLD) WATER SUPPLY RISER PIPES IN WALL AT EXISTING VANITY SINK TO BE EXPOSED AND RE -USED AND RELOCATED FOR CONNECTION AND EXTENSION OF HOT & COLD WATER SUPPLY AT NEW VANITY SINKS. (TYPICAL BOTH SINKS/VANITIES) EXISTING 89.5" VANITY, SINK, — AND PLUMBING FIXTURES TO BE REMOVED & REPLACED EXISTING DINING ROOM (FLOOR TILE) INSTALL 1/2"0 COPPER PIPE FITTING THRU WALL WITH 1/2"x 3/8" STRAIGHT STOP ISSULATION/SHUT-OFF VALVE (1/4 TURN FULL PORT BALL VALVE, OR EQ.) WITH S.S. POLISHED BEAUTY RING (TYPICAL BOTH VANITY SINKS) EXISTING 1/2"0 COPPER (HOT & COLD) WATER SUPPLY RISER PIPES IN WALL AND SHOWER HEAD MIXING VALVE TO REMAIN IN -PLACE AND RE -USED; OR UPGRADE TO MEET HIGH TEMP. LIMIT STOP SETTING PER CURRENT CODE. REPLACE FAUCETS AND SHOWER HEAD PER HOMEOWNER'S SATISFACTION EXISTING MASTER BEDROOM (CARPETING) CLOSET EXISTING W.I.C. M� 1 (CARPETING) I �, •I \ I EUNI Ii �1 w I/ �I nLE 0 w EXISTING W.I.C. (CARPETING) EXISTING PLUMBING HOT & COLD WATER SUPPLY TO BE RELOCATED TO SINK CENTERED IN NEW VANITY MASTER BATH Cj`n M CM C C V ° M C o� � s c U .d ° m c k a � a a C a m N O 3 � CD 4 a m a C. W L, I ° � o ¢ Z o u, d cV � � o CL M EXISTING 73" VANITY, SINK, AND i PLUMBING FIXTURES TO BE REPLACED NEW 24" HIGH KNEE WALL WITH K TEMPERED SAFETY GLASS PANEL EXISTING 1/2"0 (HOT & COLD) WATER SUPPLY RISER PIPES FOR EXISTING TUB TO BE EXPOSED AND RE -USED FOR CONNECTION AND EXTENSION OF HOT & COLD WATER SUPPLY AT NEW FLOOR �C MOUNT TUB FILLER. SUPPLY MODIFICATION SCALE: 3/8" =1'-0" GENERAL PLUMBING CONSTRUCTION NOTES: 1. MATERIALS AND INSTALLATION OF PLUMBING PIPING FOR SANITARY DRAINS, VENTS, AND WATER DISTRIBUTION SHALL CONFORM TO REQUIREMENTS OF THE 2017 FBC-RESIDENTIAL CODES, WITH MATERIALS AS SPECIFIED ON SHEET A-5, AND AS NOTED AND SHOWN ON THESE PLANS. 1. LOCATION OF EXISTING HOUSE WASTE DRAIN PIPES, BUILDING DRAIN (SANITARY SOIL/WASTE DRAIN PIPE), AND BUILDING SEWER PIPE, HAVE NOT BEEN DETERMINED BY THE E.O.R. EXISTING HOUSE BUILDING DRAIN, SANITARY SOIL PIPE, WASTE DRAIN PIPE, AND VENT PIPES, SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. PLUMBING CONTRACTOR SHALL DETERMINE LOCATION OF EXISTING SANITARY SOIL, WASTE DRAIN PIPE, AND VENTS, WITHIN VICINITY OF THE BATHROOM, AND AS NEEDED TO INSTALL NEW BATHROOM VALVES AND FIXTURES. 2. LOCATION OF EXISTING HOUSE COLD (& HOT) WATER SUPPLY PIPE SERVING BATHROOM PLUMBING FIXTURES HAVE NOT BEEN DETERMINED BY THE E.O.R. PLUMBING CONTRACTOR SHALL DETERMINE LOCATION OF EXISTING COLD (& HOT) WATER SUPPLY PIPE WITHIN BATHROOM, AND AS NEEDED TO MODIFY, CONNECT AND EXTEND NEW WATER SUPPLY PIPE TO NEW BATHROOM SINKS, SHOWER AND TUB. 3. EXISTING HOUSE HOT WATER SUPPLY PIPE IS ASSUMED TO BE PARALLEL TO EXISTING HOUSE COLD WATER SUPPLY PIPE 4. PROVIDE NEW )f DIA. (MINIMUM) HOT & COLD WATER SUPPLY PIPING FROM OLD WATER SUPPLY PIPE TO NEW VANITY SINK FAUCET, TUB, AND SHOWER FIXTURES WITHIN EXISTING INTERIOR PARTITION WALLS. 5. PROVIDE 1/2" DIAMETER FULL -PORT SHUT OFF BALL VALVE AT HOT & COLD WATER SUPPLY LINES TO NEW VANITY SINK, SHOWER AND TUB. 6. PROVIDE COLD WATER HAMMER ARRESTORS AT DEAD END VANITY SINK WATER SUPPLY LINE, IF NEEDED. 7. ALL HOT AND COLD WATER PIPE INSTALLED IN UN -CONDITIONED AIR SPACE MUST BE INSULATED AND WRAPPED TO MEET CONFORMANCE NTH 2O17 FBC-ENERGY CONSERVATION CODE, SECTION R403.5.6. SEE SHEET No. A-5 FOR PLUMBING INSULATION SPECIFICATIONS. 8. INSTALL NEW 1 1/4" DIA. PVC WDV PIPE AT THE RELOCATED VANITY SINK BOWL WITH PIPE TRAP. 9. CONNECT TO EXISTING VANITY SINK, TUB, AND SHOWER DRAIN PIPES WITH NEW SCHEDULE 40 PVC PIPE AND FITRNGS TO SERVE NEW BATHROOM DRAINS. PIPE SIZE OF NEW WASTE DRAIN AND RISER PIPES, MUST MATCH SIZE OF EXISTING WASTE DRAIN PIPES. DO NOT REDUCE PIPE SIZE. 10. HOMEOWNER SHALL SELECT AND/OR FURNISH ALL NEW BATHROOM PLUMBING FIXTURES AND ACCESSORIES, FOR INSTALLATION BY GENERAL CONTRACTOR. I f L.v FOR E COUNTY Igqii44 SEE SHEET A-5 for PLUMBING MATERIAL SPECIFICATIONS 0 a c w V) 5 a N�p I 00 w �z N Gi W A ® 2 Fu J U CCU S Lu x 3 a Vl rn cli 00 m ~ ch Y m ¢a N h N N Z o IL U) V� U W E Z Z 1 U an Z NJ W ® OC E Vi o r Lu W0 M � cm v/LL..r Q ® �m0Coe V Z V = 0 .T. co E " (2 Rp 4) �C4CD C. 14 v/ 3 J r"T W �w N� Timothy C. 13oudah 514 S.W. PSI. Blvd. Port St. Lucie, Pl. 34953 P.E. No. 63179 f Dat SCALE AS NOTED JOB NO": 1319.0525 A-3 SHEET 3 OF 5 EXISTING PLUMBING WALL EXISTING DINING ROOM (FLOOR TILE) CLOSET EXISTING MASTER BEDROOM (CARPETING) EXISTING WALL MOUNT A/C RETURN GRILLE EXISTING WALL MOUNT - A/C SUPPLY REGISTER (E) N \ 2688 P.D. EXISTING W.I.C. >. (CARPETING) \ a EXISTING W.I.C. 3 I Q z y kl m nl (E) _ a. in m IUll w � `------' ) (E)/ EXISTING WALL MOUNT (E/R) (E� A/C SUPPLY REG15TER� - / (CARPETING) EXISTING NUTONE SWITCH BANK, UGHT/WNT/HEAT (E/R) jE�) \\ i (E/RE/R(E) Fl ° , T GFI I ` -----------------------------�-- --- LINE OF SOFFIT/SHELF I I I ABOVE WITH RECESSED \ I I EXISTING MASTER LIGHTING FIXTURES \ BATH RELOCATE EXISTING � \ (E/RR)) HEAT LIGHT & FAN \ ()// \\ REMOVE EXISTING SHOWER LIGHT NG REMOVE EXISTING RECEPTACLE OUTLET—/ 0 JACUZZI PUMP REUSE EXISTING CIRCUIT WIRING FOR (2) NEW RECEPTACLE OUTLETS NEAR NEW VANITIES 9 ALL EXISTING ELECTRICAL DEVICES (OUTLETS, RECEPTACLES, LIGHT FIXTURES, LIGHT SWITCHES, AND OTHER ELECT. DEVICES) ASSOCIATED WITH THE EXISTING BATHROOM ARE SHOWN ON THIS PLAN WITH DESIGNATION SYMBOLS AND DEVICE ABBREVIATION. EX Na ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION (E) EXISTING SINGLE POLE ROCKER LIGHT SWITCH SET 0 44" AFF TYPICAL (U.N.O. ON PLAN) O(E) EXISTING DUPLEX RECEPTACLE OUTLET WALL MOUNTED 0 12 AFF TYPICAL (U.N.O. ON PLAN) O(E) EXISTING GROUND FAULT INTERRUPTER DUPLEX GFI RECEPTACLE OUTLET (D(E) EXISTING JACUZZI TUB TIMER E) INCANDESCENT CEILING L GIHSTING T F XTURESSED ) V EXISTING SURFACE MOUNTED CEILING LIGHT FIXTURE (E) EXISTING EXHAUST FAN UNIT WITH LIGHT FIXTURE O (E) EXISTING CEILING MOUNT EXHAUST FAN EXISTING COMMON ELECT. POWER CIRCUIT WIRING — r (CONCEALED ABOVE CEILING & IN WALLS) EX. 53" x73" SH ELECTRICAL DEVICE ABBREVIATIONS: (E) EXISTING ELECTRICAL DEVICE TO REMAIN IN -PLACE & RE -USED E/R RELOCATE ELECTRICAL DEVICE/RE-USE BRANCH CIRCUIT HARING E/A REMOVE ELECTRICAL EXISTING DEVICE/ABANDON CIRCUIT WIRING E/RR REMOVE & REPLACE EXISTING ELECTRICAL DEVICE WITH NEW DEVICE (RE -USE BRANCH CIRCUIT WIRING) (N) NEW ELECTRICAL DEVICE: SWITCH, RECEPTACLE, LIGHT FIXTURE, ETC., - TO BE INSTALLED - C DUPLEX RECEPTACLE OUTLET SET ABOVE COUNTER TOP BACK SPLASH GFI-R GROUND FAULT INTERRUPTED (DUPLEX RECEPTACLE) HVAC l E43END and ABBREIAATIONS: EXISTING CEILING MOUNTED SUPPLY AIR REGISTER WITH VOLUME DAMPERS Ld HEATING VENTILATION AND AEI 1. BATHROOM REMODEL WORK DOES NOT REQUIRE ANY CHANGES OR MODIFICATION TO EXISTING WHOLE HOUSE HVAC SYSTEM R A/C SUPPLY COMPONENTS. 2. ALL EXISTING BATHROOM CEILING MOUNTED SUPPLY AIR REGISTERS AND SUPPLY •'- AIR DUCTS TO REMAIN IN -PLACE AND FUNCTIONAL. TION PLAN SCALE: 3/8" = 1'-0" l- • • • • _ - • • _ SINCE ALL ELECTRICAL LIGHTING AND POWER CIRCUITS WILL BE REUSED, AND NO NEW ELECTRICAL CIRCUIT IS REQUIRED R PLANNED, ELECTRICAL LOAD CALCULATIONS ARE NOT REQUIRED, AS THERE IS NO ANTICIPATED INCREASE IN ELECTRICAL POWER LOAD ON EXISTING MAIN BREAKER SERVICE PANEL REMOVE (4) EXISTING LIGHT FIXTURES IN CEILING SOFFIT, PATCH & FINISH CEILING 1 - INSTALL (8) NEW HIGH HAT L.E.D., RECESSED LIGHT FIXTURES IN CEILING - REUSE EXISTING CIRCUIT HARING AND INSTALL (2) NEW LIGHT SWITCHES INSTALL (2) NEW 4"0 WALL MOUNTED ELECT. JUNCTION BOXES FOR NEW VANITY UGHT FIXTURES v IL INSTALL (2) NEW WALL MOUNTED LIGHT SWITCHES REUSE EXISTING LIGHTING CIRCUIT - INSTALL (2) NEW CEIUNG MOUNTED 6" RECESSED VAPOR SEALED LE.D. LIGHT FIXTURES ABOVE 3 SHOWER GLASS PARTITION - INSTALL (1) NEW WALL MOUNTED LIGHT SWITCH 0 EXISTING LIGHT SWITCH - REUSE EXISTING LIGHTING CIRCUIT RELOCATE EXISTING LGHT/4ENT/HEAT CEILING MOUNT FIXTURE 4 - PER HOMEOWNER SPECIFICATION TOWARD CENTER OF NEW SHOWER - REUSE EXISTING CIRCUIT WIRING AND SWITCHES F- REUSE ELECTRICAL CIRCUIT FROM JACUZZI PUMP AND REROUTE WIRING TO INSTALL (1) NEW \� L GFl RECEPTACLE OUTLET AT EACH SINK VANITY GENERAL ELECTFUCAL CODE REOLAREMENTS- 1. THE NEW UGHTNG AND RECEPTACLE LOCATIONS ARE DIAGRAMMATIC AND IS NOT INTENDED TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE ELECTRICAL CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL NECESSARY WIRE, CONDUIT, CONNECTORS, SWITCHES, RECEPTACLES, ELECTRICAL FIXTURES AND EQUIPMENT, ETC., AS REQUIRED FOR A COMPLETE AND FUNCTIONAL ELECTRICAL LIGHTING AND POWER SYSTEM, AS HEREIN NOTED AND INDICATED ON THIS PLAN. 2. ALL ELECTRICAL INSTALLATION WORK, MATERIALS, AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE 2017 FBC-RESIDENTIAL CODES, PART IV, CHAPTERS 34 THROUGH CHAPTER 41, AND NFPA-70, 2014 NATIONAL ELECTRICAL CODE REQUIREMENTS, AS MAY BE APPLICABLE, OR OTHERWISE SPECIFIED IN THESE PLANS, AND ALL APPUCABLE LOCAL CODES AND ORDINANCES, AS MAY BE REQUIRED BY ST. LUCIE COUNTY BUILDING DEPARTMENT, 3. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT LOCATION AND PROVIDE ROUGH -INS FOR ALL EQUIPMENT FURNISHED BY OTHERS. AFTER ALL EQUIPMENT HAS BEEN INSTALLED, THE ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AND PROVIDE ALL NECESSARY WIRE CONDUIT, CONNECTORS, SWITCHES, RECEPTACLES, JUNCTION BOXES, ETC. THAT ARE REQUIRED TO MAKE FINAL CONNECTIONS. 4. ALL EXISTING ELECTRICAL SUPPLY CIRCUITS TO BE RE -USED. RE -USE EXISTING CONVENIENCE RECEPTACLE CIRCUITS AND WALL SWITCHES AS INDICATED. PROVIDE NEW LIGHT FIXTURES, CONVENIENCE ELECTRICAL OUTLETS AND WALL SWITCHES WHERE INDICATED. 5. VERIFY EXACT LOCATION OF NEW LIGHTING FIXTURES, AND WALL MOUNTED SWATCHES WITH HOMEOWNER. 6. IN ACCORDANCE WITH NFPA-70, 2014 NEC, ARTICLE 210.11(C)(3); THE BATHROOM OUTLET RECEPTACLE MUST BE SUPPLIED BY THE ORIGINAL HOUSE 20 AMP BRANCH CIRCUIT DEDICATED TO BATHROOM POWER SUPPLY, R A NEW DEDICATED 20 AMP BRANCH CIRCUIT MUST BE PROVIDED TO SERVE THIS BATHROOM RECEPTACLE. 7. CONVENIENCE DUPLEX OUTLET RECEPTACLES LOCATED IN THE BATHROOM MUST BE 125V, 15 AMP R 20 AMP OUTLET RECEPTACLE THAT IS UL LISTED (UL 943) GROUND -FAULT CIRCUIT -INTERRUPTER RECEPTACLE (GFl-R), OR PROTECTED BY A GROUND -FAULT INTERRUPTER CIRCUIT BREAKER (GFI-C), PER FBC-R, SECTION E3902 (NFPA 70, 2014 N.E.C., ARTICLE 210.8(A)). 8. BATHROOM CONVENIENCE DUPLEX RECEPTACLE MUST BE TAMPER RESISTANT IN ACCORDANCE WITH FBC-R, SECTION F4002.14 (NFPA 70, 2014 NEC, ARTICLE 406.12.) EXISTING PLUMBING WALL EXISTING DINING ROOM (FLOOR TILE) EXISTING MASTER BEDROOM (CARPETING) EXISTING WALL MOUNT A/C RETURN GRILLE EXISTING WALL MOUNT - A/C SUPPLY REGISTER (E) i \EX 265E P.D. CLOSET EXISTING W.I.C. (CARPETING) \ Q EXISTING W.I.C. EXISTING WALL MOUNT - A/C SUPPLY REGISTER (CARPETING) i Z =W to E L) X , � W (E) (E) — -_ (N) EXISTING NU TONE SWITCH (N) /( BANK, LIGHT/VENT/HEAT \ \ , i GFI E \ I SN ------ --�--- -�----�---- / I----�--------�- GFI Y (N) "f (N) I (N) "1" (N) / !� i 1 (N) "r" (N) "T" (N) "I"(N) MASTER BATH I (E) (N) \ (E) ) a THROOMI EX, 53" x73" SH PLAN ALL NEW ELECTRICAL DEVICES (OUTLET RECEPTACLES, LIGHT FIXTURES, LIGHT SWITCHES, SCALE: 318" = 1'-D " EXHAUST FAN, AND OTHER ELECT. DEVICES) TO BE MODIFIED OR INSTALLED FOR THE BATHROOM REMODEL WORK ARE SHOWN ON THIS PLAN WITH DESIGNATION SYMBOL/DEVICE ABBREVIATION. NEW ELECTRICAL SYMBOL LEGEND SYMBOL- DESCRIPTION 0___ NEW ELECTRICAL MODIFICATION IDENTIFICATION NOTE $(N) SINGLE POLE ROCKER SWITCH (15A, 125V) SET TO MATCH PP EXISTING SWITCH HEIGHT (U.N.O.) N=NEW q(N) WALLESETEABOVECLE 0 NTER BACK SPLASH (U.N.O. ON PLAN) N=NEW NEW 6" RECESSED L.E.D. VAPOR SEALED CEILING N) LIGHT FIXTURE WITH LENS R NEW 4" HIGH HAT L.E.D. RECESSED LIGHT FIXTURE (N) (W/O LENS) y NEW WALL MOUNT VANITY LIGHT FIXTURE 090" AFF WITH GLOBE NEW @(N) FOR ELECTRICAL WIRING ORCEILING DEVICE JUNCTION BOX NEW COMMON CIRCUIT WIRING 12 AWG MIN. ----- NMC/ ROMEX, OR BETTER) CONCEALED IN WALL C3 M � w ° M O W m IJ '0 2 J Lo M N � hM1 C w' U a a v „ a � t — = •� e v l0 C-D W W � CJ u c O a a C N It N � ° d M t REVIEWED FOR ._M'.�`D 0�,APUANCE SEE SHEET A-5 for ELCTRICAL MATERIAL SPECIFICATIONS W M f` z O/� M to ^ tV p C ] ao 3 a E y rn m q ® rn I a 9 0 cn e If Z 0 O jw V� a 0 W o i li i O Z i i , i z uj f Z J W W ' 0 ® �W/ C I.I= 3. U) o R W i PWF)u V co _ 'QAA C v / I �a0- �' LL m ® �O/ r c!) z 3 0 =M Eu = e O= ON fi"3 r J " y W 2 ad w J a J Y J z n Timothy C. Boudah 514 S.W. PSI_ Blvd. y Port St. Lucie, F1. 3495,17 P.E. Y No. 63179 r 9 y ° Date: %N z SCALE: AS NOTED JOB NO.: 1319,0525 0 A-4 SHEET 4 OF 5 CODES AND STANDARDS: 1. ALL CONSTRUCTION MUST CONFORM TO 2017 FLORIDA BUILDING CODE -RESIDENTIAL, AND CONFORMANCE WITH APPLICABLE REFERENCED INDUSTRY STANDARDS LISTED THEREIN, AND AS SPECIFIED IN THESE PLANS. HOMEOWNER/CONTRACTOR NOTES: 1. ANY DISCREPANCIES ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE COMMENCING WORK. 2. THE HOMEOWNER/CONTRACTOR IS SOLELY RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL,SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE ENGINEER IS NOT RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION OR FOR RELATED SAFETY PRECAUTIONS AND PROVISIONS. INSPECTIONS: 1. THE HOMEOWNER/CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE ALL MANDATORY INSPECTIONS REQUIRED BY THE ST. LUCIE COUNTY BUILDING DEPARTMENT ARE MET. DEMOLITION NOTES: 1. HOMEOWNER/CONTRACTOR MAY BE REQUIRED TO OBTAIN DEMOLITION PERMIT BEFORE PROCEEDING WITH THE WORK. CONTACT LOCAL BUILDING AUTHORITIES GOVERNING THIS WORK , AND TO BECOME FAMILIAR WITH LOCAL LAWS AND REGULATIONS , A. DISCONNECT ALL ELECTRICAL SYSTEMS WITHIN THE AREA TO BE DEMOLISHED BEFORE PROCEEDINCN WITH DEMOLITION WORK. C. DEMOLISH ONLY THE MEMBERS SPECIFIED IN THE DEMOLITION PERMIT. TAKE EVERY PRECAUTION TO PROTECT EXISTING STRUCTURE THAT IS TO REMAIN. D. REMOVAL, ABANDONMENT, SEALING AND CAPPING EXISTING WATER DISTRIBUTION PIPE, SANITARY WASTE, DRAIN AND VENT PIPE MUST BE PERFORMED IN ACCORDANCE WITH APPUCABLE PROVISIONS OF THE 2017 FBC-RESIDENTIAL-PLUMBING CODES. E. REMOVE ALL RUBBISH AND DEBRIS FROM THE HOUSE AND OFF THE PROPERTY ON A DAILY BASIS. WOOD CONSTRUCTION: 1. LUMBER USED FOR INTERIOR KNEE WALL SOLE PLATE SHALL CONSIST OF PRESSURE TREATED (P.T.) SOUTHERN YELLOW PINE STRUCTURAL GRADE NO.2, OR BETTER. PRESSURE TREATMENT (P.T.) SHALL CONFORM TO AWPA STANDARDS AND MEET ONE OF THE FOLLOWING USE CATEGORIES: A. MICRONIZED COPPER QUATERNARY (MCQ): AWPA UC2 STANDARD; MINIMUM RETENTION = 0.25 PCF. B. DISODIUM OCTABORATE TETRA HYDRATE (DOT): AWPA UC2 STANDARD, MINIMUM RETENTION = SBX 0.28 PCF C. EQUAL OR BETTER THEN NOTED, 2. DIMENSIONAL FRAMING LUMBER USED FOR INTERIOR WALL FURRING AND OR WALL STUD CONSTRUCTION SHALL MEET THE FOLLOWING MINIMUM SPECIES AND GRADE: MEMBER GRADE & SPECIES: INTERIOR 2X4 STUD WALL FRAMING NO. 2 S-P-F, OR BETTER AND TOP PLATES: BLOCKING & ALL MISC. LUMBER: STUD GRADE S-P-F, OR BE1TIER (Fb min =550 PSI, Ft min =3211 PSI, & E=1,200,000 PSI) ALL HEADER MATERIAL: NO. 2 STRUCT S-P-F, OR BETTER PLACEMENT 1. INTERIOR NON -BEARING WALL STUDS SHALL BE PLACED NOT MORE THAN 24 INCHES ON CENTER. CONVENTIONAL WOOD FRAMING TO BE CONSTRUCTED TO MEET MINIMUM REQUIREMENTS PER CHAPTER 6 OF THE FLORIDA BUILDING CODE -RESIDENTIAL AND AS OTHERNISE DETAILED ON THESE CONSTRUCTION PLANS. 2. DRILLING AND NOTCHING OF STUDS, WALL PLATES, AND ALL CONVENTIONAL FRAMING LUMBER SHALL CONFORM TO REQUIREMENTS AS SPECIFIED IN FBC-R, SECTION R602.6, R602.6.1, AND PIPE UTILITIES PASSING THRU OR WITHIN STUD FRAMING CAVITY SHALL BE PROTECTED WITH 16 GAUGE STEEL SHIELD PLATE INSTALLED IN CONFORMANCE WITH SECTION P2603.2. 3. PROVIDE ADEQUATE BLOCKING FOR ALL FRAMING REQUIRED FOR LIGHT FIXTURES, ELECTRICAL AND MECHANICAL EQUIPMENT, ETC. 4. PROVIDE STRUCTURE SUPPORT BLOCKING AT EACH GRAB BAR TO SUSTAIN 300 LB STATIC LOAD. FRAMING CONNECTORS and FASTENERS: 1. FASTENERS (NAILS & SCREWS) SHALL BE HOT -DIPPED ZINC -GALVANIZED IN ACCORDANCE WITH ASTM A 153 STANDARDS, CLASS C, OR SHALL BE TYPE 304 STAINLESS STEEL, ASTM A-167, MEETING MECHANICAL REQUIREMENTS OF ASTM F593., OR BETTER. 2. MINIMUM REQUIREMENTS FOR NAILING THE WOOD FRAMED MEMBERS SHALL MEET NUMBER AND FASTENER SIZE AND TYPE AS LISTED IN THE NAILING SCHEDULE FBC-RESIDENTIAL TABLE R602.3(1). 3. FRAMED KNEE WALL WITH PRESSURE TREATED SILL PLATE OVER CONCRETE FLOOR SHALL BE SECURED WITH 1/4'0 TAPCON MASONRY SCREWS X 1 1/2" MINIMUM EMBEDMENT AT 20' O.C. MAXIMUM, OR SHOT PINS AT 16" O.C. MAX., PER MANUFACTURER'S RECOMMENDATIONS, SUCH AS HILTI LOW VELOCITY POWDER ACTUATED TOOL WITH 0.177" DS PINS, OR RAMMSET #N48. SECURING PLATE WITH MASONRY NAILS IS NOT ACCEPTABLE CONCRETE SCREWS ("TAPCONS") 1. TAPCON SCREWS USED FOR FASTENING 2X4 SOLE PLATE FRAMING TO CONCRETE SLAB SHALL BE "TAPCON" AS MANUFACTURED BY READ HEAD/ITW BUILDEX CONSTRUCTION PRODUCTS; MIAMI DADE NOA #16-1222.06 (EXP. DATE: AUGUST 31, 2021); OR EQUAL. A. ALL SCREWS SHALL HAVE A HEX WASHER HEAD (WITH 5/8" DIA. WASHER) B. SCREWS MUST BE CORROSION RESISTANT WITH "BLUE & SILVER CUMASEAL" FINISH MEETING ASTM G85 TEST STANDARDS, OR BETTER. C. EQUIVALENT CONCRETE SCREWS MUST HAVE MIAMI-DADE N.O.A. OR FLORIDA PRODUCT APPROVAL NUMBER THAT MEET OR EXCEED THE REQUIRED LOAD SPECIFICATIONS AS NOTED BELOW. D. CONCRETE SCREWS SHALL BE 1/4"0 X 3" LONG "TAPCON" SCREW WITH THE FOLLOWING LOAD CAPACITY (AT MINIMUM EDGE DISTANCE): LOAD SPECIFICATIONS CONCRETE( 002 0 PS) (1 1/2" EMBEDMENT) MINIMUM ULTIMATE TENSION CAPACITY: 1252 LBS. MINIMUM WORKING TENSION CAPACITY: 313 LBS. MINIMUM WORKING SHEAR CAPACITY: 232 LBS. GYPSUM DRYWALL: 1. INSTALLATION OF INTERIOR GYPSUM DRYWALL BOARD, UNLESS OTHERWISE REQUIRED BY HOMEOWNER, SHALL CONSIST OF STANDARD 36" THICK GYPSUM WALLBOARD CONFORMING TO ASTM C1396, WITH TAPERED EDGES. ALL INTERIOR CEILINGS WITH TRUSS SPACED GREATER THAN 18" SHALL REQUIRED )4" CEILING RATED (SAG -RESISTANT) GYPSUM WALLBOARD, PER FBC-RESIDENTIAL TABLE R702.3.5, OR 5/8" THICK GYPSUM WALLBOARD. 2. METAL TRIM SHALL MEET OR EXCEED THE FOLLOWING: A. CORNER BEADS: U.S. GYPSUM #103 B. CASING BEADS: U.S. GYPSUM #200A C. CONTROL JOINTS: U.S. GYPSUM #093 3. TAPE AND COMPOUND SHALL MEET OR EXCEED THE FOLLOWING: A. REINFORCING TAPE: 1-7/8" WIDTH TO 2-1/2 ASTM C 475 B. JOINT COMPOUND: ASTM C 475. 4. BACKER BOARD FOR ATTACHMENT OF ADHESIVE APPLIED CERAMIC OR PORCELAIN TILE APPUCATIONS, THAT IS NOT EXPOSED TO WET CONDITIONS, MAY CONSIST OF WATER-RESISTANT GYPSUM BACKER BOARD MANUFACTURED IN COMPLIANCE WITH ASTM C1396, C1178 OR C1278. V THICK BACKER BOARD IS PERMITTED ON CEILING WHEN APPLIED TO FRAMING SPACED 12" O.C. MAX., AND MUST BE W THICK WHEN CEILING FRAMING IS SPACED 16" O.C. OR GREATER. 5. BACKER BOARD USED FOR WET APPLICATIONS, AS REQUIRED IN THE NEW SHOWER AREA MUST CONSIST OF FIBER -CEMENT BOARD OR FIBER -REINFORCED GYPSUM BACKER BOARD MANUFACTURED IN ACCORDANCE WITH ASTM C1288 OR C1278; OR CODE APPROVED EQUAL, PER FBC-R, SECTION 702.4.2. 6. GYPSUM WALLBOARD FASTENING SCREWS SHALL CONSIST OF #6 x 1Y4 TYPE "W" DRYWALL SCREWS CONFORMING TO ASTM C1002 STANDARDS FOR WOOD STUD AND ROOF TRUSS CONNECTIONS. DRYWALL SCREWS SHALL BE SPACED NO GREATER THAN 8" O.C. EDGES AND 12" O.C. IN THE FIELD. CONSTRUCTION SPECIFICATIONS INTERIOR FINISHING: 1. ALL INTERIOR FINISHING WORK, MATERIALS, AND WORKMANSHIP SHALL BE DETERMINED AND SPECIFIED BY THE HOMEOWNER. 2. REMOVAL AND REPLACEMENT OF EXISTING BATHROOM FLOOR TILE AND EXISTING SHOWER WALL TILING, SHALL BE DETERMINED BY THE CONTRACTOR IN ACCORDANCE WITH HOMEOWNER'S SPECIFICATIONS. 3. ALL WOOD CASING, BASE BOARD MOLDING, FLOOR COVERING, TRIM, PAINT, AND FINISHING WORK, MATERIALS, AND WORKMANSHIP SHALL BE DETERMINED AND SPECIFIED BY THE HOMEOWNER. SU13GRADE PREPARA11ON: 1. BEDDING AND BACKFILL COMPACTION BELOW THE NEW BATHROOM SHOWER FLOOR SHALL BE ACHIEVED BY MEANS AND METHODS DETERMINED BY THE RESPONSIBLE CONTRACTOR. 2. INTERIOR PLUMBING TRENCH BACKFILL COMPACTION SHOULD BE ACHIEVED TO YIELD A SOIL DENSITY = 90% OF THE MAXIMUM DRY UNIT DENSITY OF THE EXISTING BACKFILL SOILS AS DETERMINED BY MODIFIED PROCTOR METHOD PER ASTM D-1557. 3. TRENCH BACKFILL SOIL DENSITY TESTING BY INDEPENDENT SOILS TESTING FIRM SHALL BE REQUIRED WHEN THE HOMEOWNER REQUIRES VERIFICATION OF THE PLUMBING TRENCH BACKFILL COMPACTION SOIL DENSITY. 4. PLACEMENT OF CONCRETE TO RESTORE BATHROOM SHOWER FLOOR SLAB SHALL NOT COMMENCE UNTIL BACKFILL COMPACTION REQUIREMENTS AS SPECIFIED IN THESE NOTES HAVE BEEN MET UNLESS OTHERWISE DIRECTED BY THE HOMEOWNER AND CERTIFICATION OF TERMITE PROTECTION SO TREATMENT IS N L OBTAINED FROM A QUALIFIED PROVIDER IN ACCORDANCE NTH PROVISIONS OF THE FBC-RESIDENTIAL, SECTION R318.1. 5. CONCRETE FLOOR PATCH MATERIAL MUST BE PLACED OVER A 6 MIL (MIN. THICKNESS) POLYETHYLENE VAPOR BARRIER (OR EQUAL) WHEN SOIL TREATMENT IS APPLIED FOR TERMITE PROTECTION SEAL BARRIER AT PLUMBING PIPE PENETRATIONS WITH HIGH DENSITY POLYETHYLENE ADHESIVE TAP. CONCRETE WORK: 1. CONCRETE WORK ASSOCIATED WITH THE CONCRETE SHOWER FLOOR SLAB AND PATCH WORK OVER THE NEW PLUMBING PIPE TRENCH SHALL BE PERFORMED WITH SITE MIXED CONCRETE MIX AS DETAILED AND NOTED IN THESE PLANS. 2. PROTECTING AND CURING THE FINISHED CONCRETE SHOWIER FLOOR SLAB AND PATCH WORK MUST BE PERFORMED FOR NO LESS THAN 14 DAYS. PLUMBING AND PIPING CONSTRUCTION MATERIALS: PLUMBING FIXTURES AND ACCESSORIES 1. OWNER/CONTRACTOR SHALL SELECT EACH PLUMBING FIXTURE AND ALL APPURTENANCES FOR USE IN THE BATHROOM. 2. PLUMBING FIXTURES STANDARDS SHALL COMPLY WITH CHAPTER 27 AND FLOW EFFICIENCIES SHALL COMPLY WITH CHAPTER 29 (TABLE P2903.2) OF THE 2017 FBC-RESIDENTIAL CODE, AND ANY LOCAL ORDINANCE OR STATE LAW GOVERNING WATER FLOW RATE AND WATER CONSUMPTION OF PLUMBING FIXTURES. PIPE AND PIPE PRODUCTS 1. COLD WATER DISTRIBUTION PIPE LINES SHALL BE COPPER, MINIMUM WEIGHT NOT LESS THAN TYPE L ABOVE GRADE, AND TYPE K BELOW GRADE, MEETING ASTM B88. SOLDERED JOINTS SHALL CONFORM TO ASTM B 828 AND CONTAIN LESS THAN 0.2 X LEAD, WITH FLUX CONFORMING TO ASTM B813. OTHER WATER -DISTRIBUTION PIPE AS LISTED IN FBC-R, TABLE P2906.5 WITH FITTINGS LISTED IN TABLE P2906.6, MAY BE USED. 2. ALL WATER SUPPLY SERVICE PIPE, DISTRIBUTION PIPE, CONNECTIONS, FITTINGS, CONTROL VALVES, FAUCETS AND APPURTENANCES MUST BE LISTED AS CONFORMING TO NSF 61. 3. SHOWER CONTROL VALVE MUST BE EQUIPPED WITH PRESSURE -BALANCE VALVE, OR THERMOSTATIC MIXING VALVE, OR COMBINATION PRESSURE -BALANCE/ THERMOSTATIC MIXING VALVE, CONFORMING TO ASSE 1016 OR ASME A112.1016, MATH HIGH TEMPERATURE LIMIT STOP NOT GREATER THAN 120 DEGREES F. 4. HAND-HELD SHOWER HEAD SHALL BE PROVIDED WITH BACKFLOW PROTECTION IN CONFORMANCE WITH ASME A112.18.1 STANDARDS, OR CODE ALLOWED EQUAL 5. MODIFICATION TO EXISTING DRAIN, WASTE, AND VENT PIPE SHALL PERFORMED WITH PVC DWV PIPE, METING ASTM 2665, SCHEDULE 40 MINIMUM, OF MINIMUM SIZE REQUIRED BY CODE. 6. MODIFICATION AND INSTALLATION OF ANY ABOVE -GROUND WASTE, DRAIN AND VENT PIPE MUST CONFORM TO ASTM F409 OR MATERIAL AS LISTED IN FBC-R, TABLE P3DO2.1(1). 7. MODIFICATION AND INSTALLATION OF UNDERGROUND WASTE, DRAIN, VENT PIPE, AND BUILDING DRAIN PIPE: MUST CONFORM TO MATERIAL LISTED IN FBC-R. TABLE P3002.1(2). 8. ALL WASTE, DRAIN, AND VENT PIPE FITTINGS MUST CONFORM TO MATERIAL LISTED IN FBC-R, TABLE P3002.3. 9. WATER HAMMER ARRESTER, IF NEEDED SHALL BE BELLOWS OR PISTON TYPE WITH PRESSURIZED CUSHIONING CHAMBER CONFORMING TO ASSE 1010. MANUFACTURED WATER HAMMER ARRESTERS SHALL BE SMITH NO 3000 SERIES "HYDROTROLS", JOSAM, ZURN OR EQUAL, INSTALLED IN ACCORDANCE WITH PLUMBING AND DRAINAGE INSTITUTE STANDARD NO. WH2O1. ALL OTHER COLD WATER LINES MAY BE PROVIDED WITH A 15" HIGH AIR CHAMBER PIPE. 10. WHERE PIPE INSULATION IS REQUIRED TO MEET REQUIREMENTS OF THE FLORIDA BUILDING CODE, OR IF DESIRED BY THE HOMEOWNER„ AND ANY HOT OR COLD WATER PIPE INSTALLED ABOVE CEILING SHALL BE INSULATED. HOT AND COLD WATER PIPING INSULATION SHALL BE SELECTED TO MEET THE FOLLOWING PARAMETERS: A. MINIMUM OF i" THICK FIBERGLASS INSULATION, WITH A FIRE RETARDANT JACKET, HAVING AN AVERAGE THERMAL CONDUCTIVITY NOT EXCEEDING 0.22 BTU INCH PER SQ.FT. PER DEGREE F, PER HOUR (APPROX. R-VALUE = 4.5) AT A MEAN TEMPERATURE OF 100 DEGREES F. COLD WATER PIPING INSULATION SHALL BE PROVIDED WITH A VAPOR BARRIER WITH MAX WATER VAPOR TRANSMISSIONS 0.05 PERM -INCH. B. PIPE INSULATION SHALL HAVE A FLAME SPREAD AND SMOKE DENSITY RATING NOT EXCEEDING 25/50 AS TESTED PER ASTM STANDARD E-84. 11. IN CONFORMANCE WITH 2O17 FBC-ENERGY CONSERVATION CODE, SECTION R403.5.3, PRESCRIPTIVE HOT WATER PIPE INSULATION SHALL CONSIST OF A MINIMUM RATED INSULATION R-VALUE=3, APPLIED TO HOT WATER PIPING AS FOLLOWS: A. PIPING 3/4 INCH DIAMETER AND LARGER, B. PIPING LOCATED OUTSIDE CONDITIONED AIR SPACE, C. PIPING FROM HOT WATER HEATER TO A DISTRIBUTION MANIFOLD, D. PIPING LOCATED UNDER THE FLOOR SLAB, AND E. SUPPLY AND RETURN PIPING IN RECIRCULATION SYSTEM (OTHER THAN DEMAND RECIRCULATION SYSTEMS). VALVES 1. ALL COLD (AND HOT) WATER DISTRIBUTION PIPE LINES SHALL BE PROVIDED WITH FULL PORT BALL VALVES WITH STEM LEVEL 1/4 TURN HANDLES. INSTALLATION 1. PLUMBING PIPE SHALL BE INSTALLED IN CONFORMANCE WITH 2O17 FBC-RESIDENTIAL CODE CHAPTER 26, AND REFERENCE STANDARDS NOTED THEREIN. 2. SEAL PIPE PENETRATIONS THROUGH CEILING FRAMING WWTH APPROVED FIRE STOPPING SEALANT MATERIAL 3. PROVIDE ALL PIPE CONNECTIONS WITH INDUSTRY STANDARD FITTINGS IN ACCORDANCE WITH APPLICABLE PLUMBING CODES, ASME B16, AND ASTM STANDARDS FOR ALL PIPE PRODUCTS USED. INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF EQUIPMENT. 4. INSTALL DIELECTRIC COUPLING AND NIPPLE FITTINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS IN ANY WATER PIPING. 5. SHOWER CONTROL VALVE MUST BE PRESSURE -BALANCE OR THERMOSTATIC -MIXING TYPE, OR A COMBINATION PRESSURE-BALANCE/P*RMOSTAI1C MIXING VALVE, WITH HIGH TEMPERATURE LIMIT STOP, MANUFACTURED AND TESTED IN CONFORMANCE WITH ASME 1016/ASME A112.1016, PER 2017 FBC-R, SECTION Prom. TESTING AND CLEANING WHEN REQUESTED BY LOCAL BUILDING INSPECTOR, OR IF REQUIRED BY CODE, PLUMBING CONTRACTOR SHALL TEST AND CLEAN ALL MODIFIED PLUMBING AS FOLLOWS: 1. All NEW WATER SUPPLY PIPING (HOT & COLD WATER) SHALL BE WATER TESTED TO PRESSURES OF AT LEAST 1.5 TIMES THE STATIC WORKING PRESSURE OF THE BUILDING SUPPLY WATER PRESSURE, OR 50 PSI MINIMUM, FOR A MINIMUM OF 15 MINUTES, AFTER INSTALLATION, IN CONFORMANCE WITH FBC-R, SECTION P2503.7. 2. NEW AND MODIFIED WATER SUPPLY PIPING (HOT & COLD WATER) MUST BE STERILIZED, AFTER PRESSURE TESTING, AND BEFORE PLACING WATER SUPPLY SYSTEM INTO SERVICE, WITH A DISINFECTANT METHOD RECOGNIZED FOR POTABLE WATER PER AWWA B300, USING SODIUM HYPOCHLORITE SOLUTION OR CALCIUM HYPOCHLORATE GRANULES OR TABLETS; DILUTED TO NOT LESS THAN 25 mg/L CHLORINE/WATER SOLUTION, RETAINED IN NEW OPERATING PIPING SYSTEM FOR AT LEAST 24 HOURS, THEN FLUSHED TO REMOVE ALL CHLORINATED WATER, 3. DRAIN, WASTE AND VENT PIPE (DWV SYSTEM) SHALL BE WATER OR AIR TESTED, IN ACCORDANCE NTH FBC-RESIDENTIAL, SECTION P2503.5 AFTER ROUGH AND FINISHED PLUMBING INSTALLATIONS. 4. NEW SHOWER LINER INSTALLATION MUST BE TESTED IN ACCORDANCE WITH FBC-RESIDENTIAL, SECTION P2503.6, OR BETTER. ELECTRICAL CONSTRUCTION MATERIALS: CONTRACTOR NOS 1. THE ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED FOR THE WORK BY ALL AUTHORITIES HAVE JURISDICTION. 2. ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE. BY GENERAL CONTRACTOR OR HOMEOWNER. 3. CORRECTION OF ANY DEFECTS TO BE COMPLETED WITHOUT ADDITIONAL CHARGE AND TO INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. SWITCHES AND RECEPTACLES 1. ALL GENERAL PURPOSE LIGHT SWITCHES AND RECEPTACLES SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER, SUCH AS BY PASS & SEYMOUR, BRYANT, HUBBELL, OR LEVITON. COLOR OF DEVICES AND PLATES SHALL BE DICTATED BY THE HOMEOWNER. A. SINGLE POLE SNATCH: 15 AMP, 120/277V AC, COMPLYING NTH UL E3896. B. GENERAL USE 120V DUPLEX RECEPTACLES: NEMA NO. 5-20R, 2-POLE, 3-WIRE GROUNDING TYPE, 125 VAC., 20 AMP RATING, SPECIFICATION GRADE, COMPLYING WITH UL E2186, MATH TAMPER -RESISTANT RATING, OR EQUAL C. GROUND -FAULT CIRCUIT INTERRUPTER RECEPTACLES (GFI-R), MATH TAMPER -RESISTANT RATING; 120 VAC., 20 AMP RATING: SHALL MEET UL 943 STANDARDS MATH UL CLASS A TRIPPING REQUIREMENT PER NFPA M 2014 N.E.C., ARTICLE 210.8(A); NEMA NO. 5-20R, 3-MARE GROUNDING TYPE; OR EQUAL D. WALL PLATE COVERS FOR ALL SWITCHES AND RECEPTACLES SHALL BE SMOOTH PLASTIC FASTENED WITH METAL SCREWS HAVING HEADS MATCHING PLATE COLOR. HOMEOWNER TO SELECT COVER PLATE STYLE AND COLOR. LIGHTING FIXTURES 1, ALL LIGHTING FIXTURES, MANUFACTURER AND TYPE OF NEW LIGHTS TO BE SELECTED BY HOMEOWNER/GENERAL CONTRACTOR AND INSTALLED BY THE LICENSED ELECTRICAL CONTRACTOR. 2. ELECTRICAL CONTRACTOR SHALL INSTALL AND/OR RE -MARE ALL CEILING AND WALL MOUNTED LIGHT FIXTURES AS NOTED ON THE PLANS, AND PROVIDE ALL NECESSARY LAMPS, BALLASTS SOCKETS, HOUSING, CEILING TRIM RINGS, BRACKETS, LENSES/DIFFUSERS AND OUTLET BOXES, AND ALL OTHER APPURTENANCES NEEDED TO PROVIDE A COMPLETE AND FUNCTIONAL LIGHTING SYSTEM. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE INSTALLATION OF LIGHTING FIXTURE AND APPURTENANCES WITH HOMEOWNER/GENERAL CONTRACTOR, WIRES AND CABLES 1. ALL ELECTRIC CONDUCTORS AND GROUNDING WIRES SHALL BE MINIMUM WIRE SIZE OF #12 AWG SOLID FOR RECEPTACLE POWER VARING AND #14 AWG SOLID FOR GENERAL LIGHT FIXTURE WIRING, WITH THWN/THHN INSULATION, OR NM SHEATHED CABLE. 2. CONDUCTOR MATERIAL SHALL BE LIMITED TO COPPER WIRE, ALUMINUM WIRE IS NOT ACCEPTABLE. 600 V INSULATION (ASTM STANDARD COMPOUNDS) AS REQUIRED BY NEC. 3. PROVIDE GROUNDING CONDUCTOR WHEN RUN WITH CIRCUIT CONDUCTORS WITH SAME INSULATION AS CIRCUIT CONDUCTORS. BOXES AND ENCLOSURES 1. OUTLET BOXES, PULL AND JUNCTION BOXES SHALL CONFORM TO NEMA 250, TYPE 1, EXCEPT IN DAMP OR WET LOCATIONS USE NEMA 250, TYPE 3R, OR CODE APPROVED EQUAL GROUNDING 1. ELECTRICAL CONTRACTOR MUST VERIFY THAT THE EXISTING HOUSE GROUNDING ELECTRODE SYSTEM CONSIST OF ALL AVAILABLE GROUNDING CONDUCTORS BONDED TOGETHER IN ACCORDANCE WITH FBC-R, SECTION E3908 (NFPA 70, 2014 N.E.C. ARTICLE 250.50). HEATING, VENTILATION & AIR CONDITIONING: 1. PROPOSED BATHROOM REMODEL WORK WILL NOT AFFECT EXISTING HVAC SUPPLY AIR DUCT WORK OR RETURN AIR GRILLES, AND WILL NOT REQUIRE ANY MODIFICATIONS TO THE EXISTING H.V.A.C, SUPPLY OR AIR -RETURN DUCT SYSTEM. 2. PROPOSED BATHROOM REMODEL WORK WILL NOT AFFECT THE ENERGY PERFORMANCE OF THE EXISTING H.V.A.C. SYSTEM, THEREFORE, FLORIDA ENERGY CODE CALCULATIONS ARE NOT REQUIRED, UNLESS OTHERWISE SPECIFICALLY REQUESTED BY THE GOVERNING BUILDING PERMITTING. EXHAUST AIR 1. EXISTING BATHROOM EXHAUST FANS TO BE PROTECTED IN -PLACE AND RE -USED. 2. NO MODIFICATION TO EXISTING BATHROOM EXHAUST FANS PROPOSED. U Ld M C O U -ni rnl u 2 J N N CL a v J = C L: N 3 LL. � 0) w' U i O 3 C a CL Z O N N a a a 3 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC w U � A_ N I✓`N 1yIs r,� E W Z �J�1 :FLU❑WSJ z � v / C/p� M�1 rh ^ N • W U (Hj F N N rn N °D m ~ U in Y m ~ h 0 8 ui Z z 0 O� 0 0 z z U L Z NJ Q W ® � Q W C �' d vI > O p, W Wuc*0 v+ LL ' a U) >°. U. Rb 0 /'J^^ Z V _ V C ci :3v, ECD Q m GNn"' ''AA J v/ r+ W �ad � �// Y �y w Timothy C. Boudah 514 S.W. PSL. Blvd. Port SC. Lucie, Fl. 3495 P.E. No. 63179 A l rr� Dater SCAM AS NOTED JOB NO.: 1319.0525 A-5 SHEEP 5 OF S