Loading...
HomeMy WebLinkAboutSLC FIRE DISTRICT PLAN REVIEWST LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION SCANNED PLAN REVIEW BY 2400 Rhoqp Island Avenue Telephone: 772-462-83 Ft Pierc , FL 34950 FAX: 772-462-8466 ( )New Construction ( )Tenant Improvement ( )Addition ( )Renovation/alterations ( )Shell Only Jurisdiction: SLC F.P.B.: B-04-354 Occupancy: Dickerson of Florida Building Dept: 24061255 Address: 3122 North 25th St Number of stories: 2 Contractor Proctor Construction Company Phone # 772-234-8164 Contractor's Address: 1401 Hwy AIA, Suite 301 City: Vero Beach State: FL Zip Code: 32963 Architect/Engineer: WCG/Neel-Schaffer Phone # 772-770-4707 Building Owner: Review Date: 8/16/2004 Occupancy Type: Business Automatic sprinklers: Gross sq ft: 16,000 Net sq ft: Occupant Load: Based On: Construction Type: SBCCI Type: IV unp NOTE 1. All revisions must be in compliance before the final inspection. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Permit fees are required to be paid in full prior to any inspections. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ). 7. Penetrations through rated assemblies shall be of proper UL design. 8. UL design criteria shall be submitted with the construction plans. 9. Fire Alarm Panels shall be located indoors. THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED. REVISIONS REQUIRED ACCESS BOX IS REQUIRED ( ) ACCESS KEY SWITCH REQUIRED ( ) /1. Stairs: Maximum riser height is 7 inches. The plans indicate +/- 7 3/16". ✓2. Door Number 8 requires a 3/4-hr door and jamb assembly equipped with a self -closing device. 0 FFPC 1 �3. Doors 14 and and 43 43 require a 1-hr. door and jamb assembly equipped with aself-closing device. FFPC 101-8.2.3.2.3 ✓4. Stairwell door number 14 shall swing in the direction of egress. FFPC 101-7.2.1.4.3 The change will cause the door to swing more than one-half of the required width of the corridor. ■ ■ Revise accordingly. FFPC 101-7.2.1.4.4 W �5. Provide an exit light fixture above door number 30 in the north entry corridor. r� '6. Provide an exit light fixture above door number 47 on the second floor. -'�7. Plan notes indicate a fire alarm system. A separate permit is required. -1'18. Provide portable fire protection. i 9.1 Provide the UL rated ceiling assembly number and design criteria sheet. -10. The second floor storage shall be separated from the remainder of the occupancy by not less than 1-hr. rated construction. Provide information on the epicore system. Reviewed by: �-' L J,¢.p Date: 8/16/2004