Federal Communications Commission 23
iv .4111r r Public Safety and Homeland Security Bureau
,
x, •CeMMIS�e
RADIO STATION AUTHORIZATION
Licensee: ST. LUCIE COUNTY FIRE DISTRICT FCC Registration
Number (FRN): 0012236766
SIGURD BO
ST. LUCIE COUNTY FIRE DISTRICT
5160 NW MILNER DRIVE
PORT ST. LUCIE FL 34983
SGANNED
13Y
St. Lucie County
Call Sign File Number
WQFR287 0002938831
Radio Service
PW - Public Safety Pool,
Conventional
Regulatory Status
PMRS
Frequency Coordination Number 1
gram Wale 06 I Effective Date Expiration Date Print Date
09-14-2003-08-2007 o9-14-2016 03-o8-2007
1. STATION TECHNICAL SPECIFICATIONS
'fixed Location Address or Mobile Area of Operation
Loc.
1 Address
1201-1 LENNARD DRIVE
City County
PORT ST, LUCIE ST. LUCIE
Let (NAD83): 27-18-14.3 N Long (NAD83): 80-16-46.9 W
-oc.
2 Address
7583'OCEAN DRIVE
City County
JENSEN BEACH ST. LUCIE
Let (NAD83): 27-17-50.2 N Long (NAD83): 80-13-5-2 W
-oc.
3
Address
777 DALTON CIRCLE
City
PORT ST. LUCIE
Let (NAD83): 27-15-49.2 N
-oc-
1
Address
201 BECKER ROAD
City
PORT ST. LUCIE
Let (NAD83): 27-12-36.5 N
.oc.
Address
300 NW CALIFORNIA BLVD
City
PORT ST. LUCIE
County
ST. LUCIE
Long (NAD83): 80-24-43.2 W
County
ST. LUCIE
Long (NAD83): 80-21-29-3 W
County
ST. LUCIE
State
F
ASR 2
S
FL
ASR No.:
State
FL
ASR No.:
State
FL
ASR No.:
State
FL
:onditions:
'ursuant to Section 309(h) of the Communications Act of 1934, as amended, 47 U.S.C. Section 309(h), this license is
ubject to the following conditions: This license shall not vest in the licensee any right to operate the station not cv)1
ght in the use of the frequencies designated in the license beyond the term thereof nor in any other mcnrlel than
luthorized herein. Neither the license nor the right granted thereunder shall be assigned or otherwise transferred in
iolation of the Communications Act of 1934, as amended. See 47 U.S.C. Section 310(d). This license is subiect in
brms to the right of use or control conferred by Section 706 of the Communications Act of 1934, as amended
ee 47 U.S.C. Section 606.
FCC 601 - ULSHSI
December 2006
'Richter Engineering, Inc.
Certificate of Authorization 09356
April 26, 2007
St. Lucie County Building Dept
Ft. Pierce, FL
Re: 120-Ft Self Support Tower CON
St. Lucie County, FL
FILE
Dear Building Official:
It is understood that Expert Construction Managers is proposing to construct a 120-ft self
support pole for this site.
The tower will be designed in accordance with the 2004 Florida Building Code (FBC)
and the Telecommunications Industry Association Standard TIA/EIA-222-F standard.
The basic wind speed is a design wind velocity, which means that the tower will safely
withstand the fall design wind velocity and still maintain an additional load capacity
known as a "Safety Factor." The safety factors used to design communication poles are
the same factors used in building design. A safety factor of 1.25 is specified by the
American Institute of Steel Construction (AISC) and a factor of 1.3 is specified by the
American Concrete Institute (ACI). These safety factors are incorporated into both the
pole and foundation design. A 1.25 safety factor means that the pole would have to be
subject to 25% more load (than the design load) before failure would theoretically occur.
This tower was designed with the top 40-ft meeting the design wind criteria, while the
lower 80-ft of the pole and anchor rods will be over -designed to resist more than the
design wind loads. When steel becomes overstressed it does not suddenly break, it will
bend and buckle. In the unlikely event that this pole would experience a wind event that
would cause a collapse, the upper portion of the pole would become overstressed first and
would buckle. The upper portion of the tower would then double over and hang from this
level or, at worst, break off resulting in a fall radius of approximately 40-ft. Once the
upper portion is no longer upright catching the full force of the wind, the stresses in the
lower portion of the pole are reduced, making a further collapse of the tower unlikely.
If you haveany further questions, please feel free to contact me.
Mark Richter, PE
FLPE 56196
Mail: 2007 W. Reynolds St, Plant City, FL 33563 * 813-754-8148 ■ FAX 813-752-0512
- '11
MR. -A
Mark V. Richter
Licensed Professional Engineer
2007 West Reynolds St. • Plant City, 33563 • Tel 813.500.0362 • Fax 813.782.0512
May 16, 2007 COPYFILE
Expert Construction Managers, Inc.
815 S. Kings, Ave.
Brandon, FL 33511
RE: St. Lucie County Fire Department, Fire Station #8
120' SS tower
Please be advised that we will inspect the construction on the above referenced project
and provide an engineering letter for $500.
Mark V. Richter, P.E.
Florida License # 56196
R
Mark V. Richter
Licensed Professional Engineer
2007 West Reynolds St. • Plant City, 33563 • Tel 813.600.0362 • Fax B13.752.05.12
May16,2007 FILE COPY
Expert Construction Managers, Inc.
815 S. Kings, Ave.
Brandon, FL 33511
RE: St. Lucie County Fire Department, Fire Station #8
120' SS tower
Please be advised that we will inspect the construction on the above referenced project
and provide an engineering letter for $500.
Mark V. Richter, P.E.
Florida License # 56196
Page 1 of 1
Saint Lucie County, Florida
Property Appraiser's - Internet Mapping Print Service
N.
Y
art
F
' .w.. \��.` ✓���g g","." :lam `•)
'fr; ( �►
Map Legend:
--Interstates
Toll, Roads
— MajorRoeds
(] �bdNision
Condo
�20+Acres
0' Parcels
Q;I'mprvd Sales
[,] Land Sales
http://www.paslc.org/StlPrintnew.asp?Cmd=SIZE&Se1Cmd=&MapWidth=647&MapHeight=487&activeLayer-8&where=o&... 4/20/2007
44
OPPE0.0
R C TEST BORING RECORD
SCIENCES
BORING NO: FS#8
PROJECT: Fire Stations No. 8 and 15
JOB NO: 06-1249-64
REPORT NO: 001
PROJECT LOCATION: Fort Pierce, FL
ELEVATION: Not Provided
BORING STARTED: 11/9/2006
BORING COMPLETED: 11/9/2006
DRILLING METHOD: Mud Rotary
RIG TYPE: Dietrich D50
HAMMER: Rope and Cathead
GROUNDWATER: _% 4.0 ATD
BORING DIAMETER (IN): 3
SHEET 1 OF 2
Remarks:
G
(FT.)
(�)
DEPTH
(FT)
MATERIAL DESCRIPTION
L
S
R
RESISTANCE N TI N
O
0 10 SO JO 0 50 60 70 609010
BLOWS
5„
Brawn -orange -tan fine SAND (SP)
Tan fine SAND (SP)
Tan fine SAND (SP) with few limerock fragments
5
Dense tan fine SAND (SP) with trace limerock
fragments
10 - 14 -
21
Dense tan fine SAND (SP) with few limerock
fragments
12 - 17 -
23
10
Very firm to dense to gray fine SAND (SP) with trace
to few shell fragments
11 -12 -
15
15
8-15-
20
19
9-15-
25
Ila
_M
0 P0.0PER0
R C TEST BORING RECORD
S C I E N C E S
BORING NO: FS#8
PROJECT: Fire Stations No. 8 and 15
JOB NO: 06-1249-64
REPORT NO: 001
PROJECT LOCATION: Fort Pierce, FL
ELEVATION: Not Provided
BORING STARTED: 11/9/2006
BORING COMPLETED: 11/912006
DRILLING METHOD: Mud Rotary
RIG TYPE: Dietrich D50
HAMMER: Rope and Cathead
GROUNDWATER: Q 4.0 ATD
BORING DIAMETER (IN): 3
SHEET 2 OF 2
Remarks:
FILE C(j PY
G
ELEVPENET
(Fr.)
DEPTH
MATERIAL DESCRIPTION
L
S
RDARDI
STANRESISTANCE (N)RATION
a ro xo ao ao so so ro es solo
BLOWS
25
30
35
ao
45
50
9-15-
17
9-15-
17
9-15-7
Very firm to dense to gray fine SAND (SP) with trace
to few shell fragments(Continued)
Very firm gray clayey fine SAND (SC)
Boring terminated at 40 feet. Boring was backfilled
with grout.