HomeMy WebLinkAboutFIELD DENSITY TESTIr
1798 AGORA CIRCLE S.E. SUITE 5
PALM BAY, FLORIDA 32909
FIELD DENSITY
DATE: 01/19/05 ORDER NO:
CLIENT: B & D GRADING INC.
�6� 1 2CC5
ACTED SOIL
-ol:c Works
ADDRESS: 2790 COOLIDGE ROAD FORT PIERCE, FLORIDA 34945
AVENUE
UDA 33069
059i NSF
PROJECT: PROPOSED RESIDENCE BUILDING PAD LOT 31, THE RESERVE, THE LAKES
ADDRESsT. dgCHAMPIONS WAY ST LUCIE COUNTY FLORIDA
MATERIAL DESCRIPTION: BROWN SAND
LOCATION: N.E. CORNER OF PAD
LOCATION: S.W. CORNER OF PAD SCANNED
LOCATION: S E CORNER OF PAD gy
LOCATION:
St. LUCiecouylty
FIELD DENSITY METHOD AS.T.M. D-2922
DRY DENSITY P.C.F. IN THE FIELD
106.9
106.2
106.4
%MOISTURE
8.7
9.6
10.1
% COMPACTION IN THE FIELD
98.7
98.0
98.2
% COMPACTION REQUIREMENT
95%
PROCTOR VALUE, P.C.F.
109.4
OPTIMUM MOISTURE, %
12.5
LABORATORYNO.
P-1521
DEPTH ININCHES
12
PROCTOR A.S.T.M D-1557 METHOD
REMARKS; SOIL NOT TESTED BELOW FOOTINGS
TESTED BY: SL
CHECKED BY: KM
As a mutual protection to clients, the public and ourselves, all reports
are submitted n the confiderdial property of clients, and augwization
for publication ofsWemcnts, c onclusiom or e#racls fmm or mgm ding
our repoAs is reeved pending our written approval.
RespecUblly submitted,
yVi
s sa P. SAM S. N fA. P.E.
FEDERAL ENGINEERING & TESTING
FLORIDA REG. #39584