HomeMy WebLinkAboutENGINEERING - FIELD DENSITY TEST1798 AGORA CIRCLE S.E. SUITE 5
PALM BAY, FLORIDA 32909
250 S.W. 13T" AVENUE
POMPANO BEACH, FLORIDA 33069
FIELD DENSITY TESTS OF COMPACTED SOILS
DATE: 5/29/08 ORDERNO: 08-1607 PERMIT NO. 08-030272
CLIENT: HEMMINGWAY HOMES
PROJECT: PROPOSED RESIDENCE BUILDING PAD %�urnnee&A.0
BY
ADDRESS: 1103 TILTON ROAD, PORT ST. LUCIE, FLORMA St I lldeCou*
MATERIAL DESCRIPTION: DARK BROWN SILICA SAND
LOCATION:
10' DIAG FROM NW CORNER
LOCATION:
I O' DIAG FROM SE CORNER
LOCATION:
10' DIAG FROM SW CORNER
FIELD DENSITY METHOD AS.T.M. D-2922
DRY DENSITY P.C.F. IN THE FIELD
107.5
106.6
107.1
• MOISTURE
8.7
7.5
8.1
• COMPACTION IN THE FIELD
99.3
98.4
98.9
% COMPACTION REQUIREMENT
95%
PROCTOR VALUE, P.C.F.
108.3
OPTIMUM MOISTURE, %
12.0
LABORATORYNO.
P-712
�NyED
V
DEPTH IN INCHES
12
6� G
REc
�UN 0 2 2098
PROCTOR A.S.T.M D-1557 METHOD
public Worku
county, HL
St. Lucie
REMARKS: SOILNOTTESTED BELOW FOOTINGS
TESTED BY: SL Respectfully submitted,
CHECKED BY: KM fS 'ID�
WISSAIv1 S. NAe�1I I,
As a mutual protection to clients, the public and ourselves, all reports FEDERAL ENGMM G a TESTING
are submitted as the confidential property of clients, and authorization FLORIDA REG. H39584'
for publication ofstatements, conclusions or extracts from or regarding CERTIFICATE OF AUTHORIZATION 4 5471
our reports is reserved pending our written approval.
A density test determines the degree of soil of the tested layer ofmaterial only. A density does not replace a soil bearing capacity determination.