Loading...
HomeMy WebLinkAboutALUMINUM STRUCTURE PERMITCERTIFICATION: t This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO - - OBTAIN -FINANCING, CONSULT WITH YO.UR_LENDER OR ANATTO_RN_EY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in high Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction.: I. understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Ow 'r Builder, have verified that the existing foundation meets the requi ments of the Engineer of Record and i deatYbtk condition to withstand the uplift and weight of the aluminum s ucFZ nd said structure will not exceed the to tint%�i,(..,e structure that was in existence prior to removal by the sto �/ SIGNATURE STPI,TE OF FLORIDA COUNTY OFF- L"Cl� The foregoing instrument was acknowledged before me this�day of c� 2t�, by l-ii P:'Y7 n I klftU y,who is personally own to me or wit s, produced identification. (SEAL) je ft.% Kevin i Stevrart �T My �COmmi48i0n M354413 Ev rM OU' DW 29.200s IMPORTANT NOTICES: STATE OF FLARIDA COUNTY OFf The foregoing instrument was acknowledged before me this may of 20tE� by cs who is personally known to me or wh It produced `(L dentification. . iimature of Notary (SEAL) .00% Kevin jS*,.t W Cammissigt M354413 NTE*nn 0061)M29.2005 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. ONLY: Date: $I / I I Fee Due: Receipt# Permit #19 �l 1. 2. 3. 4. ALL INFO MUST BE COMPLETE & FILLED -IN TO BE ACCEPTED /V P-EV5 /V St. Lucie County Building and Zoning -2300-VirginiaAvenue - n�11nn11C Ft. Pierce, FL 34982-5652 - - SUAN ED 772-462-1553 BY �;f. I 1 iP.lp COUTItt/ APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION LOCATION/SITE ADDRESS:_1103 Tilton Road Port Saint Lucie FL 34952 S/DNAM&: ST Lucie Gardens SITEPLANNAME: Bessemer PROPERTY TAX ID#: 3414-501-0704-000-3 LEGAL DESCRIPTION (attach extra sheets if necessary): St Lucie Gardens 23 36 40 BLK 3 Lot 4-Less S 10 FT and Less RD R/W (9.62 AC) 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. 3 NO. 4 9. PARCELS ACRE Q FT. 0 -LhOT DIMENSIONS i � �O X, D 135AW 10. SETBACKS (ACTUAL) FRONT:_ BACK: 7%'% 2GHT SIDE: I LEFT SIDE: i5O 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade, SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X ❑- CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X )a POOLENCLOSURE N Sty❑ NEW E{ EXISTING 32 X 59 1,888 ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X TOTALSQUARE FOOTAGE OF CONSTRUCTION 1,888 12. VALUE OF CONSTRUCTION: $ 15.220.00 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDVForm N0.:001-02 Rev.2/19/07c1 NAME:"Willian Bessemer ADDRESS: 1103 Tilton Road CTTy. Port Saint Lucie, FL STATE: FL PHONE (DAYTIME): pz7J 701_3500 email: ZIP 34952 FILL IN NAME AND. ADDRESS BELOW 1F THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: PHONE (DAYTIME): CONTRACTOR INFORMATION STATE: 011 STATE OF FLORIDA REG./CERT #: ST. LUCIE COUNTY CERT #: BUSINESS NAME: Pioneer Screen Cc Onc II 1682 SW Biltmore St QUALIFIER'SNAME: Michael J Newman ADDRESS: 1682 SW Biltmore Street CITY: Port Saint Lucie STATE: FL PHONE(DAYTIME): (7721 340-4393 FAXNO.772-340-4626 ARCHITECT/ENGINEER: BDQ, Inc ADDRESS: 1950 NE%170th-, Avenue CITY: 'iVrfrHiS\_�`�)&� STATE: FL 0 34984 email: Pioneerscreen@msn.com ZIP H016" a` 19c-, �_Q PHONE (DAYTIME): (352) 529-0080 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPi ICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear'and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFICE USE ONLY ZONING41, Y ' ` "t s SECTION TOWNSHIP _ RANGE MAP NO. 37 OAS �3 �! l�J D l• Additional Yes ZONING ytn LAND USE u LOT CVG % Permits no � Y ( REPORT CODE j I BIMS FEE $ MISC FEES it #r- TOTAL FEES $ ;BUILDING.`& ZONING-REVIEW,x, REVIEWS ZONING ZONING PLANS MISC. VEGETATION VALUE OF CONSTRUCTION REVIEWED BY EXAMINER USING ICC TABLE DATE COMPLETE Q U I INITIALS PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE.ONE- OF —THE -FOLLOWING: X 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4" wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girls, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 0 wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. u Code Compliance Division 2300 Virginia Avenue FL Pierce, FL 34982 Phone: (772) 462.1553 Fax: (772) 462-1148 http://stiucieco.gov/ce issued:-09/24/2008 - Job Location: 1103 TILTON RD Permit Type: Pool Enclosure Job Description: BUILDING PERMIT Page 1 Conf #: 516- — Permit #: SLC 0808-0098. City: PORT ST LUCIE SCANNED AN/ INSTALLATION OF POOL ENCLOSURE - POOL# 0808-0097 St. UM- 011o/ S/D St Lucie Gardens S/D Lot: 4 Block: 3 Parcel: 3414-501-0704-000/3 Contractor NEWMAN MICHAEL J PIONEER SCREEN COMPANY INC II (772) 340-4393 1682 SW BILTMORE ST Property Owner WILLIAM K BESSEMER 5561 NW THYER CIRCLE Setbacks Left:150.00 Number of Units: 1.00 Minimum Floor Elevation: PORT ST LUCIE, FL 34984 (772)878-2704 PORT ST LUCIE, FL 34983 Right: 118.00 Front: Rear: 779.00 Zoning: RM-5 Floors: 2 Buildings: 1 Square Footage: 0.00 Flood Map: 283F Flood Zone: A Elev: 18.86 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this properly that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10). F.S. - WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY, BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit.