Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WINDOW PAPERWORK
HAYFIELD� ��I� ��,D� � �I e""D(su' R� C�?� ��P �'Y INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHORS ARE REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN ATOLERANCE OF±1/2INCH OF THE DEPICTED LOCATION IN THE ANCHOR LAYOUT DETAIL (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE I/4 INCH. SH IM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. S. FINLESS INSTALLATION: FOR INSTALLATION INTO WOOD FRAMING USE #8 WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1 112 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. 6. FIN INSTALLATION: FOR INSTALLATION INTO WOOD FRAMING USE k8 WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1112 INCH MINIMUM EMBEDMENT INTO WOOD SUBSTRATE. 7. MINIMUM EMBEDMENTAND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 8. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BYTHE ANCHOR MANUFACTURER. 10. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD -MINIMUM SPECIFIC GRAVITY OF 0.42. 201 HORIZONTAL SLIDING WINDOW (NON -IMPACT) GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE 2010 FLORIDA BUILDING CODE (FBC) AND THE 2009 IRC/IBC, EXCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • AAMA/WDMA/CSA 101/I.S.2/A440-05 2. ADEQUACY OF THE EXISTING STRUCTURAL 2X FRAMING AS MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 2X BUCKS SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCKDESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. 5. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: PVC 7. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300-04 GLASS CHARTS. SEE SHEET 2 FOR GLAZING DETAIL. 10 44" MAX. WINDOW / HEIGHT \ 2 / 64" MAX. WINDOW WIDTH 28.50" MAX. D.L.O. WIDTH „X„ - III , „o„ ELEVATION 37.75" MAX. D.L.O. HEIGHT SCANNED BY St. LucleCOODW TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 - INSTALLATION, GENERAL NOTES,A ELEVATION 2 - FIN SECTIONS, GLAZING DETAIL, A ANCHOR LAYOUT 3 - FINLESS SECTIONS, ANCHOR LAYOUT, 6 SOM DESIGN PRESSURE RATING DESIGN PRESSURE MISSILE IMPACT RATING t35 / -35 PSF NON -IMPACT Digitally signed by Hermes F Norero, P.E. Reason: I am approving this document Date: 2012.04.27 09:29:34-04'00' HAYFRED WINDOW E,DOORCOMPANY P.O. BOX 25, INDU5TRIAL RD. HAYFIELD, MINNESOTA 55940 N {u m m O Z U O ZI—L'm I --I W Z OLL d> J v V) Y i2 V) l9 Q Q Z OL O W 00 Z�OC a IO N r f W 'xm33s - LL Z o F ZLU Cz @ x H 9 L J Z 0 Hz v ^ J p H H WU LU aL w ^ 6 g OLL O m cn V) 1�' Z) 1,15 , Y U Z 2 In U 10001 1 OF 3 2X WOOD FRAME BY OTHERS SHEATHING BY OTHERS — EXTERIOR FINISH BY OTHERS PERIMETER CAULK BY OTHERS gJ ..aril O.A. WINDOW EXTERIOR HEIGHT 0 1 SEE GLAZING DETAIL 1 1/2" MIN. #8 PAN HEAD WOOD SCREW INSTALLATION ANCHOR 3/4" MIN. EDGE DISTANCE 1/4" MAX. SHIM SPACE INTERIOR rA-� VERTICAL SECTION 2 2X WOOD FRAME - HEAD FIN INSTALLATION 1.00" MAX. FROM CORNERS, TYP. 6.50" MAX. �I° O.C., TYP. r_ 1.00" MAX. FROM CORNERS, TYP. 6.50" MAX. O.C., TYP, ul ANCHOR LAYOUT FIN INSTALLATION INTERIOR EXTERIOR 2X WOOD FRAME BY OTHERS #8 PAN HEAD WOOD SCREW INSTALLATION ANCHOR 1 1/2" MIN. EMBEDMENT SEE GLAZING .TAIL HORIZONTAL SECTION \llzMEETING RAIL 3/4" MIN. EDGE DISTANCE 1/4" MAX. SHIM SPACE 1 INTERIOR SEE GLAZING DETAIL SHEATHING—� BY OTHERS EXTERIOR EXTERIOR FINISH BY OTHERS PERIMETER CAULK O.A. WINDOW WIDTH f BY OTHERS ©HORIZONTAL SECTION 2X WOOD FRAME -JAMB 2UB FIN INSTALLATION 0.75" O.A. INSULATED GLA55 1/2" GLASS _ BITE GLAZING DETAIL NOTE: GLASS THICKNESS AND TYPE MAY VARY PER A5TM E 1300 REQUIREMENT GLASS CHARTS. Aftmor i MOM L HA 000xcMDOaW P.O. BOX 25. INDUSTRIAL RD. HAYFIELD, MINNESOTA 55940 PH: 507-477-3224 FX: 5074T7-3605 H � y a Z�1O� m Z m Z¢Q o¢�S = U O �YOL k '., in 2 j; m Z Q 2 H n O 0 Z w w n 4 r V O� H H a F m w ca ix _ H 0 U- otj m r p 1'1�5 Zm mP 3= Y � SHEET: 2 OF 3 SEE GLAZING DETAIL O.A. EXTERIOR WINDOW HEIGHT PERIMETER CAULK BY OTHERS EXTERIOR FINISH BY OTHERS SHEATHING BY OTHERS #8 PAN HEAD WOOD SCREW INSTALLATION ANCHOR INTERIOR 1/4" MAX. SHIM SPACE 2X WOOD FRAME I 13/4" MIN. EDGE BY OTHERS r^�1 DISTANCE rb-'\ VERTICAL SECTION 3 2X WOOD FRAME -SILL FINLESS INSTALLATION 1.00" MAX. FROM 6.50" MAX. CORNERS, TYP. O.C., TYP, 1.00" MAX. FROM CORNERS, TYP. 6.50" MAX. O.C., TYR ANCHOR LAYOUT FINLESS INSTALLATION 1 1/2" MIN. EMBEDMENT SEE GLAZING DETAIL 11/2" MIN. EMBEDMENT 1/4" MAX. SHIM SPACE I INTERIOR EXTERIOR — O.A. WINDOW WIDTH 2X WOOD FRAME BY OTHERS #8 PAN HEAD WOOD SCREW INSTALLATION ANCHOR 3/4" MIN. EDGE DISTANCE SHEATHING BY OTHERS EXTERIOR FINISH BY OTHERS PERIMETER CAULK BY OTHERS HORIZONTAL SECTION 3 2X WOOD FRAME -JAMB FINLESS INSTALLATION BILL OF MATERIALS ITEMNO. PARTNUMBER DESCRIPTION MATERIAL MANUFACTURER 1 11GA01 FRAME HEAD, SILL, AND IAMB VINYL VISION EXTRUSIONS LIMITED 2 110A15 MAIN SASH VINYL VISION EXTRUSIONS LIMITED 3 11OA16 INTERIOR INTERLOCK SASH VINYL VISION EXTRUSIONS LIMITED 4 11OA14 SINGLE SLIDER MULLION VINYL VISION EXTRUSIONS LIMITED 6 110A18 PULLRAILSASH VINYL VISION EXTRUSIONS LIMITED 6 11OA20 SUDERTRACK VINYL VISION EXTRUSIONS LIMITED 7 110A25 SINGLE LEG GLASS STOP VINYL VISION EXTRUSIONS LIMITED r-., .Ammar iiMFRL 1A7� w HAYFff1D WINDOW a,DOORCOMPANY P.O. BOX 25, INDUSTRIAL RD. HAYFIELD, MINNESOTA 55940_ PH: 507477-3224 FX: 507-477-3605 m U 4 U00 zH ZF-w w m Z F d> J a F Y LL V) 0 � cR O w coN ne w $ CL N Z O L3 " F- IHL V ct Iq j i a a H ey dco x F- n 0. �aQ )y % T Lti 1J m CO 'o J m V V) )WG #: HDW001 SHEET: 3 OF 3