Loading...
HomeMy WebLinkAboutProduct Evaluation ReportBUILDING DROPS 127 W.FairbSuite4 8 Suite 438 Winter Park, FL 32789 A Perfect Solution in Every Drop 407.644.6957 PH Ik Certificate of Authorization: 79578 407.644.2366 FX contact@buildingdrops.com Product Evaluation Report Of JELD-WEN, inc. Energy Saver/Contour Wood Edge Steel Door for Florida Product Approval FL# FL13540 Report No. 1562 Florida Building Code 2007 & 2010 Per Rule 9N-3 Method: 1— A (Certificate) Category: Exterior Doors Sub — Category: Swinging Exterior Door Assemblies Product: Energy Saver/Contour Wood Edge Steel Door Material: Steel/Wood Product Dimensions: 74"x 81.75" 74"x80.5" 64.5"x95.25" 64.5"x94.5" ALEX SPYROU 2012.01. 12 14:53:50 -05'00' Prepared For: JELD-WEN, inc. 3737 Lakeport Blvd. Klamath Falls, OR. 97601 Prepared by: Alexis Spyrou, P.E. Florida Professional Engineer # 68101 Date: 12/01/2011 Contents: Evaluation Report Pages 1— 4 Installation Details Pages 5 Alexis Spyrou, P.E. Florida No. 68101 � f BUILDING DROPS FL#: FL18s40 A Perfect Solution in Every Drop Date: 12/01 /2011 Report No: 1562562 it Certificate of Authorization: 29578 Manufacturer: JELD WEN, Inc. Product Category: Exterior Doors Product sub -Category: Swinging Exterior Door Assemblies Compliance Method: State Product Approval Rule 9N-3.005 (i)(a) Product Name: Energy Saver/Contour Opaque Wood Edge Steel Door (impact Rated- Doors Only) 74" x 81.75" 74" x 80.5" 64.5" x 95.25" 64.5" x 94.5" Scope: This is a Product Evaluation Report issued by Alexis Spyrou, P.E. (FL # 68101) for Jetd-Wen Inc. based on Rule Chapter No. 9N-3.005, Method la of the State of Florida Product Approval, Department of Community Affairs - Florida Building Commission. Code. Limits of Use: Alexis Spyrou, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in arty other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the 2007 & 2010 Florida Building See installation Instructions JW162009, signed and sealed by Alexis Spyrou, P.E. (FL # 68101) for specific use parameters. 1. This product has been evaluated and is in compliance with the 2007 & 2010 Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the 2007 & 2010 Florida Building Code and does not require an impact resistant covering on single and double door systems. impact resistant shutters are required for sidelites and transom. 4. Site conditions that deviate from the details of drawing JW162009 require further engineering analysis by a licensed engineer or registered architect. 5. See installation Instructions JW162009 for size and design pressure limitations. Alexis Spyrou, P.E. Florida No. 68101 Page 2 of 5 BUILDING DROPS FL#:FL13540 A Perfect Solution tEvery Drop IQ Certificate of Authorization: Date: 12/01/2011 on: 2957$ Report No: 1562 Quality Assurance: The manufacturer has demonstrated compliance of door products in Accordance with the Florida Building Code and Rule 9N-3.005 (3) for manufacturing under a quality assurance program audited by anapproved quality assurance entity through National Accreditation & Management Institute, Inc. (FBC Organization #QUA1789) Performance Standards: The product described herein has been tested per: Referenced Data: • ASTM E 283-04 • ASTM E330-02 • ASTM E 331-00 • ASTM E 1886-05 • ASTM E 1996-05b 1. Product Testing performed by Quality Testing Inc. (FSC Organization # TST7638) Report #: SJW2009-199, Report pate: 1/18/2010 SJW2009-200, Report Date; 1/18/2010 2. Quality Assurance National Accreditation and Management Institute (FBC Organization #: QUA 1789) Alexis Spyrou, P.E. Florida No. 68101 Page 3 of 5 It BUILDING DROPS FL#: FL13540 /2011 A Perfect Solution in Every Drop Date: 12/01562 Certificate of Authori ation:29578 Report No: 2562 installation: 1. Approved anchor types and substrates areas follows: Through Frame Installation: A. For two by (2X) wood buck substrate, use #10 Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For concrete or masonry substrate where one by (1X), non-structural, wood bucking is employed, use 3/16" diameter nW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25' Into concrete or masonry. C. For concrete or masonry substrate where wood bucking is NOT employed, use 3/16" diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25' into concrete or masonry. Refer to Installation Instructions (JW162009) for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure 1 Positive 55 PSF* Negative 55 PSF *Product has not been rated for water infiltration. If authority having jurisdiction requires that product meets this requirement, product shall be used when installed at location protected by overhang such that overhang (OH) ratio = OH length/01-1 height is 1.0. AlexisSpyrou, P.E. Florida No. 68101 Page 4 of 5 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 79578 Installation Method JELD-WEN, inc. Energy Saver/Contour Opaque Wood Edge Inswing/Outswing ' 25 Ga. Steel Impact Door System s rvP. 3•TYP. 1 I I IIIII I 1 { b _ j i O � � F � iQ S m C � - T' FL*:FL13540 Date: 12/01/2011 Report No: 1562 Alexis Spyrou, P.E. Florida No. 68101 Page 5 of 5 74' MAX FRAME MOTH (O/OXO) 3'TYP. d �ETYP. fTYR t T- � I I I j I i I I j - I i I I I I j I j I j I j j b L T � j I I j i l `T FL*:FL13540 Date: 12/01/2011 Report No: 1562 Alexis Spyrou, P.E. Florida No. 68101 Page 5 of 5