SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 2922
DATE TESTED:
June 17, 2019
KSM JOB #: 192355-1d/SS/cv
PERMIT#:
b_ •
It!~CEIV�9
CONTRACTOR:
Ron Raymond Construction
�l�G 2 3 2019
SCANED
JOB LOCATION:
2800 S. Brocksmith Road
'BY
sT. ucie County, Permitting
Fort Pierce, Florida S$.LUCIeGou y
MATERIAL:
Brown Sand with Traces of Clay
ITEM TESTED:
Compacted Foundation Fill for the House Pad
tE§f _L6i,:;kTF(5i LOCATION
DEPTH MOIS- PEN
DRY MAX. DRY PERCENT
OF SAMPLE
TURE READ
DENSITY PROCTOR COMPACTION
----------------------------------------------VALUE
---------------
Is' Lift
1. S.W.
0 -12" 8.5 43
108.6
110.9 97.9
2. Center
" 36
106.E
" 95.8
3. N.E.
" 41
107.5
96.9
2nd Lift
4. N.W.
12" - 24" 9.7 38
106.9
110.9 96.4
5. Center
37
106.4
95.9
6. S.E.
41
107.3
" 96.8
Final Lift
7. S.W.
24" - 36" 10.2 42
108.1
110.9 97.5
8. Center
40
106.6
96.1
9. N.E.
42
108.5
" 97.8
Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366
Tr C!1 t
&%L6V4VjL
KELLER, SCHLEICHER & MacWILL1AM ENGINEERING AND TESTING, INC.
MARTIN (772) 337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772) 589-0712
PALM BEACH (5611845-7445 www.ksmangineering.net MELBOURNE (321) 768-8488
FAX (561) 845-8876 E-Mall: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093
C.A.: 5693 FAX (772) 589.6469
DATE TESTED:
PERMIT #:
CONTRACTOR:
JOB LOCATION
Soil Description:
Max. Dry Density:
Optimum Moisture:
Julie E. Keller, P.E.
President
MOISTURE -DENSITY RELATIONSHIP
MODIFIED PROCTOR (ASTM D 1557)
June 17, 2019
Ron Raymond Construction
2800 S. Brocksmith Road
Fort Pierce, Florida
KSM JOB #: 192355-1p
112T--T---7---1---I---r T--7--,
I I 1 I I I I I I
I I I I I I I I 1
111--t--7-- 1---I-----t--7--7
I I I I I I I I I
I I I I I I I I I
110t--t--1--1--- --F-- -- t--1
I I I I I I I I I
I I I I I I I I I
109+---+-- F---I— —I---F --+ — F---I
I I I I I I I I I
I I 1 I I I I I
108+-- 4a 4——1---I---I---a -- --�
I I I I I I I I I
I I I I I I I I
107�--�— t-----1-----�-- t--�
I I I I I I I I I
I I 1 I I I I I
106L--1--1--J---I---L --1 --1--J
I I I I I I 1 I I
I I I I I I I I I
105 ----4---4---4---4
9 10 11 12 13 14 15
Moisture - Percent of Dry Weight
Brown Sand with Traces of Clay
110.9 P.C.F.
12.0 Percent
Ronald G. Keller, P.E.: 37293 / SI Lie. No.: 860 / Julie E. Keller, P.E.: 68366
' 1
"l1!JAYL
KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC.
MARTIN (772) 337-7755 P.O. BOX 78-1377 SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712
PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488
FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NEr ST. LUCIE (772) 229-9093
C.A.: 5693 FAX (772) 589-6469
June 18, 2019
Ron Raymond Construction
PO Box 12058
Ft. Pierce, FL 34979
Re: 2800 S. Brocksmith Road
Fort Pierce, Florida
Permit #:
KSM Project#: 192355-1d
Dear Mr. Raymond:
AUG 2 3 2019
ST. Lucie County, Permitting
Enclosed, please find the nuclear density test results performed on the compacted
foundation fill for the house pad at the above referenced project.
Should you have any questions, please feel free to contact the office.
!t
Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366