HomeMy WebLinkAboutPLANSBuilding Permit #
Fastener: 0 10 Pancake Head Wood Fastener
TYNCAL ASSETABLY PRORLE wEw
-------------------------------
I V11MAL AUAMULY ISUME I RIC VILLA
F
-ABLE A
Roofpreas
Field
Perimeter/Corner
Mlax Design Pressure
-114.25psf
-156.75pst
Fastener Spacing
16"o.c.
D.C.4'
Fastener Size
x10
#10
METAL ROOF PANEL FASTENER: 410 X P PANCAKE -HEAD CORROSION RESISTANT WOOD
FASTENER. FASTENERS SHALL BE SUFFICIENT LENGTH TO PENETRATE THROUGH THE ROOF
SHEATHING A MINIMUM OF 3/16". TWO (2) FASTENERS SHALL BE INSTALLED IN EACH CLIP.
CLIPS SHALL BE 8" O:C. ALONG PANEL EVERY PANEL.
ROOTING ATIACHMENT
PER SUNLAST METALS MIAMI SERIES SNAP LOCK 1.75 (FL#21423.3)
UNDERLAYMENT SHALL BE INSTALLED AS PER MANUFACTURER'S INSTALLATION GUIDELINES
UNDERLAYMENT SHALL BE GCP APPLIED TECHNOLOGIES, GRACE ICE & WATER SHIELD (NOA#
18-0119.01)
FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING
THE WALL AND ROOF THROUGH JOINTS IN COr` 'NGS, THROUGH MOISTURE -PERMEABLE
MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS
THROUGH THE ROOF PLANE. ALL FLASHING SHALL BE IN ACCORDANCE WITH FLORIDA
BUILDING CODE
FLASHING SHALL BB INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER
THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE
FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS NOT
LESS THAW' PROVIDED INFBC TABLE 1503.2. Thl: REQUIREMENT DOES NOT APPLY TO HIP AND
RIDGE JUNCTIONS.
ALL ROOFING INSTALLATIONS SHALL BE IN ACCORDNNCE WITH FBC 2017.
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Owners Name Vt V L-N c7
Applicant:
a
e
�k---I
ROOF BREATHING NAILING ZONE nts... "A" = 5 FEET
(IYPIC4L GANARLC1MFPLAN"PLAN VIE"
T3 NAILS AT 6" O.C. PERIMETER AND 6" O.C. FH ID
2T NAILS AT 6" O.C. PERIMETER AND 6" O.C_ FIELD
3T " NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD
NOTE: ROOF SHEATHING SHALL BE THICK CDX PLYWOOD ROOF SHEATHING
FASTENED TO ROOF FRAMING WITH 8d RING -SHANK NAILS (PER FRC803.2.3.1) SPACED
PER ZONE DESIGNATIONS AS SHONW ABOVE.
Product
Opening Design
Pressures
Product Rated
Desl n Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
f'' A
Mullions
'
Fixed Glass
Block Glass
Skylights
Sliding Blass Doors
'
Swing Type Doors
French Doors
Garage Doors
Hurricane Protection
Roof Ventilation
Roofing Material
- 05115'
- 16-
— It4,2
t5,�5'
�ju�I,aST
i..tr.ttL,
�7�t;rr?5
L*t
Z 1 422i
I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the
wind loads and forces specified by current code provisions.
Name: Signature: ON PLAN
Design Prof: _ I� ,$$ vwel,i? .� �' �,is.� �?� Cert. No. Date:
STRUCTURAL NOTES
1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10.
2) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED.
3) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO
INSTALATION OF HARDWARE IS'NOT PERMITED.
4) UNLESS OTHERWISE NOTED, THU INSTALLATION OF SPECIFIED HARDWARE
SHALL CONFORM TO THE MAN CTURES INSTRUCTIONS AND STANDARD
PRACTICIES.
5) STUCCO CEILINGS AND SOFFIT OTE: EXTERIOR CEILING AND SOFFIT TO BE
STUCCO OVER WIRELATH W/ 11 A.'2" NAILS W/ 3/8" 0 HEAD @ 6" O.C. OVER (2
LAYERS) OF OF (15# FELT OR TY 'AK BUILDING WRAP) OVER EACH FRAMING
MEMBER ON 19/32" CDX PLYWO(D WITH IOD NAILS AT 4" O.C..
6) EXTERIOR FRAME WALLS TO BESTUCCO OVER WIRELATH WITH 11 GA. 2"
LONG NAILS WITH 3/8" 0 HEAD @ 6" O.C. OVER (2) LAYERS OF (15# FELT OR
TYVAK BUILDING WRAP) OVER 10/32" CDX PLYWOOD WITH 10D NAILS TO
STUDS @ 6" O.C. PERIMETER AND FIELD.
PLUMBING NOTES:
1) ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2017-PLUMBING
2) EXTEND ALL PLUMBING VENT STACKS UP THRUGH NEW ROOF IN
ACCORDANCE WITH FBC PLUMBING REQUIREMENTS.
ELECTRICAL NOTES
1) ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70)
2014 EDITION.
2) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT.
TRUSS CONNECTOR
SCHEDULE
TRUSS ID
BEARING POINT
TRUSS ACTUAL
CONNECTOR
CONNECTOR
FASTENERS
NOTES
_
UPLIFT
ID
UPLIFT DESIGN
AH7
1ST & 2ND
1458
(2)- HTS 20
2900
(20) -10d
H03
1ST & 2ND
1249
(1)- HTS 20
1450
(20) -10d
LH7
1ST & 2ND
2516
(1)- MGT
3965
(22) -10d & (1) - 5/8"
A.B.
0
VALLEYS
CONT.
100 # PLF
( )- MTS 16
1000
(14)-10d X 1 1/2"
t 1 STRAP AT EACH END AND AT 24" O.C.
1
O
ALL OTHERS AT
FRAME BEARING
LESS THAN 1000#
EACH
< 1000#
(1)- HTS 20
1450
(20) -ROd
AT FRAME BEARING
TRUSS COMPANY
BUILDERS FIRST
LAYOUT DATE
6 14 2019
CUT -SHEET DATE
6 14 2019
--
SOURCE
NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED.
NOTES:
1 VALLEY TRUSSES MAY BE ATTACHED WITH SIMPSON VTCR W/ (4)- #9 SO X 2 1/2" TO SUPPORTING TRUSS AND (3)- #9 SO X 1 1/2"
TO VALLEY TRUSS IN LIEU OF MTS16 AS STATED. VTCR SHALL BE INSTALLED AT EACH END AND 24" O.C. MAX.
2 USE SIMPSON EPDXY STRONG TIE SYSTEM WITH 12" MIN, EMBEDMENT FOR ANCHOR BOLTS(A.B.).
TRUS,� NOTES:
1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER.
2) CONTRACTOR TO PROVIDE PAUL WELCH INC., AND BUILDING DEPARTMENT WITH ENGINEERED
TRUSS DRAWINGS BEFORE INSTALLING TRUSSES,
3) CONTRACTOR TO VERIFY ALL EXISTING ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING,
AND INSTALLING TRUSSES.
4) TRUSS TO TRUSS CONNECTIONS TO BE PROVIDED BY TRUSS COMPANY
5) SEE TRUSS CONNECTOR SCH, FOR TRUSS TO WALL CONNECTIONS,
Planning & Development Services Department
• Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) +62-1553
Certification for Design Load Compliance
Project Name: DEVENS
Project Address: 8609 S. INDIAN RIVER DR.
Permit #: Occupancy Type: R" X Construction Type: V
INSTRUCTIONS FOR USE:
+ This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Buildine Code 2017 Edition with 20 _Supplements using ASCE 7-10
2. 2. Structure Designed as (check one): X Enclosed _ Partially Enclosed _ Open
3. Risk Category: —1 X 11 III_ IV Exposure Category: _ B C X D
4. Design Wind Velocity 180 mph 139 ASD N/A LRFD End Zone Width: 5 It
S. Mean Roof Height: 25 ft Roof Pitch: 4 :12 Parapet: N/A It
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 32.0 Zone 2: 88.5
8 5 Zone 3: 32.0 _130.9 Zone 4: 55.6 Zone 5: 55.6 Garage: 52.7
50.9 -60.3 -74.4 -68.6
7. Design Loads: Floor: N/A PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:, N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED
B. Were Shear Wails Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Ronald 1. Price 17788 / 5115
Print Name Cert # & Co. Cert Auth.
ON PLAN 7/12/2019 Paul Welch Inc.
Signature, Date, and Seal 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL
SLCCUV Form # U2U-12 Revised 3/1S/12 IA) Company Name & Address
SGANNED
St. tuce county
n PAUL. ELGH INC.
:/TVIECRANICAL rt ELECTRICAL * CIVIL ENGINEERING
= _l984 S.W. BILTMORE ST. SUITE#'1 14
N PORT SAINT LUCIE, FL 34984
PHONE EMAIL
J1P (772) 785 `9888 PWE;LCHINC@AOL.COM
RONALD J. PRICE P.E. FL. REG. NO. 17788
JUL 1 2 2019
i
'Co
O
r3DQ�
�I�'aaall0
paOO
a
WOV0
V
1>
W
=
W
cc
0
F.
� L
L)
C
C
u
c
Cam/ L
- ROOF TRUSS PLACEMENT PLAN / AREA OF WORK PLAN 3/8" V-0"
NOTES:
1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL
DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT.
2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE
ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES.
SCOPE OF WORK 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER
SCALED DIMENSIONS.
CUT EXISTING ROOF OVERHANGS OFF ON EXISTING ROOF. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE
- INSTALL NEW PITCHED ROOF OVER EXISTING ROOF PER PLAN. (FBC) 2017, FBC 2017 RESIDENTIAL, FBC 2017 PLUMBING CODE, FBC 2017
- EXTEND CHIMNEY UP. MECHANICAL CODE, FBC 2017 ENERGY CONSERVATION, AND THE NEC (NFPA - ;- -
70) 2014 EDITION. '� ��. - - _ - - PAUL WELCH INC.
5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY •. ^ - - �� ^y
^ y. ^ -+f MRCHANICAL * ELECTRICAL * CIVIL ENGINEERING
HEAVY TERMITE INFESTATION AREA PER FRC 301. _ s
6) ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B.0 ti _ 1984 S.W. BILTMORE ST. SUITE# 114
2017 FOR EXISTING BUILDINGS. ^'r.'; q' s PORT SAINT LUCIE, FL 34984
PHONE EMAIL
1772) 785.9888 PWELCHINC@AOL.COM
JUL 2 2019
RONALD J. PRICE P.E. FL. REG. No. 17788
1 �.
W�
ZZ
0
�
o'
U
W�WU
Lu
V
U
00
WWI
cc
o
U
w
U
N
O
w
c�
o0
2X8 WOOD B
EXISTING R(
W
I,.
METAL ROOFING OVER
UNDERLAYMENT ON 24/32" CDX
PLYWOOD SHEATHING NAILED
W/ 8d RINGSHANK NAILS PER
DETAIL
PRE- ENGINEERED WOOD TRUSSES
@ 24" O.C. (MAX. SPACING)'
"SIMPSON" STRAP PER TRUSS
CONNECTOR SCH.
ROOF JOIST BEYOND WALL TO BE
CUT OFF
METAL FLASHING/ DRIP EDGE
I X 8 HARDIE FASCIA OVER 2X6
WOOD. FASCIA
SOFFIT PER STRUCTURAL NOTE
# 5 WITH 4" X 22" VENTS AT 48"
O.C.
DBL 2 X 8 WOOD PLATE WITH 5/8" X
6' MIN. EMBED THREADED ROD
DRILLED OUT AND EPDXIED TO
EXISTING CONC. BEAM AT 24" O.C.
EXISTING ROOF JOIST TO REMAIN
EXISTING CONC. BEAM.
TYPICAL )VALUROOF SECTION nts...
r
TOP OF CHIMNEY SHALL BE A
MINIMUM OF 24" HIGHER THAN
THE HIGHEST ROOF WITHIN 10
FEET AWAY
METAL SPARK ARRESTOR -- - -
METAL TOP CAP / FLASHING -- / — —
DBL 2X6 CONT. WOOD TOP PLATE —1
"SIMPSON" SP6 WITH (6)- 10d —�
NAILS EACH STUD TOP AND
BOTTOM PLATES W
C'
2 X 6 WD STUDS @ 16" O.C. a
STUCCO PER STRUCT. NOTES
4
ROOF CRICKET BY BUILDER
2 X 6 P.T. WD BOTTOM PLATE W/
5/8" X 6" EMBED THREADED ROD
DRILLED OUT AND EPDXIED AT
24" O.C.
EXISTING CHIMNEY WALLS
\
CHIMNEY EXTENSION DETAIL nts...
PAMMELCH INC.
1V886PIANICAL * ELECTRICAL * CIVIL ENGINEERING
1984 S.W. BiLTMORE ST. SUITE# 114
PORT SAINT LUCIE} FL 34984
PHONE EMAIL
(772)7 85-988 8
PwELc HINC@AOLI COM
19 RONALD J. PRICE P.E. FL.
JUL L 2 20 REG. No. 17788