HomeMy WebLinkAboutGENERAC PAPERWORKProtector® QS Series INCLUDES: • Two-Une LCD Multilingual Digital Evolution'" Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position. • True Power'" Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • -*1%Voltage Regulation • Natural Gas or LP Operation GENERAC® SCANNED PROTECTOR@ QS SERIES BY Standby Generators StludeCOunty Liquid -Cooled Gaseous Engine Standby Power Rating Model RG022 (Aluminum - Bisque) - 22 kW 60 Hz Model RG027 (Aluminum - Bisque) - 27 kW 60 Hz Model RG032 (Aluminum - Bisque) - 32 kW 60 Hz Model RG038 (Aluminum - Bisque) - 38 kW 60 Hz Model RG048 (Aluminum - Bisque) - 48 kW 60 Hz • 5 Year Limited Warranty • UL 2200 Listed ce QUIFF • Capability to be installed within 18" (457) mm of a building* Meets EPA Emission Regulations 'Only if located away from doors, windows, and fresh air 22 & 27 kW are CAIMA emissions compliant intakes, and unless otherwise directed by local codes. 32 & 38 kW not for sale in CA / MA FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O SOLIDSTATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: 0 GENERAC TRANSFER SWITCHES. Long life and reliability are • PROTOTYPE TESTED v NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this • SYSTEM TORSIONAL TESTED v MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. 22.27.32.38.48kW GENERATOR Type Synchronous Rotor Insulation Class H (22 &27 kW) or F (32,38 & 48 R Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output leads 1-Phase 4 wire Alternator Output leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct VOLTAGE REGULATION Type r Electronic Sensing Single Phase Regulation 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation . 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 26 (22, 27, 32 & 38 kW) or Group 24F (48 M, 525CCA System Voltage 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All models fully prototyped tested ENCLOSURE FEATURES Aluminum weather Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added protective enclosure durability. Enclosed critical grade Quiet, critical grade muffler is mounted inside the unit muffler to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. (All ratings in accordance with BS5514, IS03046, IS08528, SAE J1349 and DIN6271) GENERAC° IIIIIIIIIIN dicatip & engineering data ENGINE SPECIFICATIONS: 22, 27, 32 & 38 kW Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bore (iNmm) 3.41/86.5 Stroke (iNmm) 3.94/100 Compression Ratio 9.5:1 Intake Air System Nahualy Aspirated (22 & 27 kW) or Turboclerged/Aftercooled (32 & 38 kW) Lifter Type Hydraulic ENGINE SPECIFICATIONS: 48 kW Make Genemc Model V-Type Cylinders 8 Displacement (Liters) 5.4 Bare (iNmm) 3.55/90.2 Stroke (iNmm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Itturally Aspirated Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge 4/3.8 (22, 27, 32 & 38 kW) or Crankcase Capacity (qVl) 6/5.7 (48 kW) ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven 1980 - 22 & 27 kW Fan Speed (rpm) 1500 - 32 & 38 kW 1954 - 48 kW 18.1/459.7 (22 & 27 kW) or Fan Diameter (iNmm) 22/558.8 (32, 38 & 48 kW) Pusher (22 & 27 kW) or Fan Mode Puller (32. 38 & 48 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14° water colum/9-26 mm HG LP Fuel Pressure 11 -141 Water Column NG Fuel Pressure 5 -14° Water Column I- \ Is 22.27.32.38.48kW GENERATOR OUTPUT VOLTAGEAW - 60 Hz GENERAC° operating data kW LPG Amp LPG kW Nat Gas Amp Nat. Gas CB Size (Both) 120/24O V, 10, 1-.0 pf 22 92 22 92 100 - - RG022 120/208 V, 30, 0.8 of 22 76 22 76 80 120/240 V, 30, 0.8 pf 22 66 22 66 80 1201240 V, 10, 1.0 pf 27 113 25 104 125 RG027 120/208 V. 30, 0.8 of 27 94 25 87 100 120/240 V, 30, 0.8 of 27 81 25 75 90 120/240 V. 10, 1.0 of 32 133 32 133 150 120/208 V, 30, 0.8 pf 32 ill 32 111 125 RGO32 120/240 V, 30. 0.8 pf 32 96 32 96 100 277/480 V, 30, 0.8 pf 32 48 32 48 60 120/240 V, 10, 1.0 pf 38 158 38 158 175 120/208 V, 30, 0.8 pf 38 132 38 132 150 RG038 120/240 V. 30, 0.8 of 38 114 38 114 125 277/480 V, 30. 0.8 pf 38 57 38 57 60 120/240 V, 10. 1.0 pf 48 200 48 200 200 120/208 V, 30, 0.8 pf 48 167 48 167 175 RG048 120/240 V, 30, 0.8 pf 48 1 144 48 144 150 277/480 V, 30, 0.8 pf 46 1 72 48 72 80 SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip Q <.4 pf Natural Gas Propane 15% 30% (ft3/hr) (m3/hr) (gaVhr) (Vhr) W/hr) 120/240 V, 10 55 135 RG022 120/208 V, 30 40 92 120/240 V, 30 35 80 120/240 V, 10 62 170 RG027 1201208 V, 30 70 120 1201240 V, 30 61 103 120/240 V. 10 75 180 RG032 1201208 V. 30 87 210 120/240 V, 30 75 182 277/480 V, 30 36 87 120/240 V. 10 75 180 120/208 V. 30 87 210 RGO38 120/240 V, 30 75 182 277/480 V, 30 36 87 120/240 V, 10 85 195 120/208 V, 30 90 218 RG048 1201240 V, 30 78 189 277/480 V, 30 36 87 Note: Fuel pipe must be sized for full load. For Btu content, multiply W/hr x 2520 (IP) or ft3/hr x 1000 (NG) For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hrx 37.26 ING) Refer to "Emissions Data Sheets' for maximum fuel flow for EPA and SCAOMD permitting purposes. Exercise cycle 42 1.2 0.44 1.7 16 25% of rated load 100 2.8 1.1 4.2 40 RGO22 50% of rated load 190 5.4 2.1 7.8 75 75% of rated load 255 7.2 2.8 10.5 101 100% of rated load 316 9 3.4 13 125 Exercise cycle 42 1.2 0.44 1.7 16 25% of rated load 108 3.1 1.2 4.5 43 RGO27 50% of rated load 197 5.6 2.1 8.1 78 75% of rated load 287 8.2 3.1 11.8 114 100% of rated load 359 10.2 3.9 14.8 143 Exercise cycle 79 2.2 0.8 3.2 30 25% of rated load 144 4.1 1.7 6.3 60 RG032 50% of rated load 226 6.4 2.7 10.3 97 75% of rated load 298 6.4 3.7 13.9 132 100% of rated load 375 1 10.6 4.6 17.5 166 Exercise cycle 83 2.3 0.9 3.2 31 25% of rated load 162 4.6 1.7 6.6 62 RG038 - 50% of rated load 255 7.2 2.9 10.8 103 75% of rated load 345 9.8 4 15 142 100% of rated load 437 12.4 5.2 19 185 Exercise cycle 95 2.7 1 3.9 38 25% of rated load 204 5.8 2.16 8.5 82 RG048 50% of rated load 392 11.1 4.14 15.7 1 151 75% of rated load 547 15.5 5.8 22.8 220 100% of rated load 756 21.5 7.96 31.3 302 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. GENERAC' 22.27.32.38.48kW operating data ENGINE COOLING 22 kW 27 kW 32 & 38 kW 48 kW Air flow (inlet air including alternator and combustion air in cfrrVcmm) 2400/68 1 2400/68 1 2200/62.3 4350/123.2 System coolant capacity(gal/lilers) 2.5/9.5 2.5/9.5 1 2.5/9.5 3/11.4 Heat rejection to coolant (BTU per hr/MJ per Inn) 99,000/104.5 105.000/110.8 1 145,000/153 186,000/196.2 Maximum operation air temperature on radiator (°C/°F) 60/150 Maximum ambient temperature (°C/'F) 50/140 COMBUSTION REQUIREMENTS Flow at rated power(cfm/cmm) 68/1.9 1 68/1.9 106/3 163/4.6 SOUND EMISSIONS Sound output in dB(A) at 23 ff (7 m) with generator in exercise mode' 61 1 61 1 58 1 63 Sound output in dB(A) at 23 it (7 m) with generator operating at normal load' 70 1 70 1 64 1 68 'Sound levels are Wlren from the front of the generator. Sound levels baleen from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfrrVcmm) 1 165/4.7 1 180/5.1 1 300/8.5 1 414/11.7 Exhaust temperature at muffler outlet(°C/°F) 1 482/900 1 538/1000 1 579/1075 1 552/1025 ENGINE PARAMETERS Rated Synchronous rpm 1800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration.................... Altitude Deration (22, 27 & 48 kW) Altitude Deletion (32 & 38 I(W) ..... CONTROLLER FEATURES ...3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F ..1 % for every 100 m above 183 m or 3% for every 1000 it above 600 it 1 % for every 100 m above 915 m or 3% for every 1000 it above 30001t Two -Line Plain Text LCD Display....................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto..............................................................................................................................................Automatic Star) on Utility failure. 7 day exerciser Off...........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual......................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds.................................................................................................................................................10 sec standard Engine Start Sequence..................................................................................................................... Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration) EngineWarm-up.....................................................................................................................................................................................................................5 sec EngineCool-Down..................................................................................................................................................................................................................1 min Starter Lock-out................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartBattery Charger........................................................................................................................................................................................................ Standard Automatic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................ Standard AutomaticLow Oil Pressure Shutdown............................................................................................................................................................................... Standard OverspeedShutdown..............................................................................................................................................................................................Standard, 72 Hz HighTemperature Shutdown...............................................................................................................................................................................................Standard OvercrankProtection..........................................................................................................................................................................................................Standard SafelyFused......................................................................................................................................................................................................................Standard Failureto Transfer Protection.............................................................................................................................................................................................. Standard LowBattery Protection........................................................................................................................................................................................................ Standard 50 Event RunLog............................................................................................................................................................................................................... Standard FutureSet Capable Exerciser.............................................................................................................................................................................................. Standard IncorrectWiring Protection.................................................................................................................................................................................................Standard InternalFault Protection.....................................................................................................................................................................................................Standard CommonExternal Fault Capability ......................................................................................................................................................................................Standard GovernorFailure Protection................................................................................................................................................................................................ Standard RADIATORIEXHAUST DISCHARGEAIR (BOTHSIDES) AIR INTAKE (BOTIH SSIIDES) BATTERY 12" 1 I NEOAT 0774 J 3ND ENCLOSEDWITHIN GENERATOR ENCLOSURE DISCHARGE AIR TOP VIEW 1040 48 (40.9j I1.91 EL LINT LEFT SIDE VIEW NOTE 5) REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. NOTES 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (431 WIDE X 1885 (74.2') LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA TO STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL I CIRCUIT BREAKER INFORMATION: -SEE SPECIFICATION SHEET OR OWNERS MANUAL -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUMP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SNITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR ANDIOR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. S. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 51&11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAMMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EIKKAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. 980 SEE NOTE 138.61 JERAU. EIGHT IEIGNT ACCESS ASSELACCEONTROL ASSEMBLY, I48 t L PANELACCESS, ryp YP BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 776 j30.61 45 OVERALL WIDTH I1. REARVIEW TYI KFIGHT WTA GIHEMT ENCLOSURE WEIGXT GEN6ETGNLY MIGHT SNIPPING 6KIG 6XN%NO WEGH! WA MATS RVA KO 61 KG 11881 K<1M1S61 MMIWN FSINGLEPMSE21.6. SE I7AKVSEt A2ALAIWH21 AL 42616/01 JORSI CVWA1WH21 DIMENSIONS: MM IINCHI RIGHT SIDE VIEW 0 45 LEFT SIDE VIEW DIMENSIONS: MM UNCHI REAR VIEW LS) 71 C/ m z m m D n s — Protector? QS Series UENERAC® Automatic Transfer Switches Service and non -Service rated Automatic -Smart Transfer Switches 100 - 400 Amps, Single Phase YL C @us C @us LISTED s ; �-- *CUL only applies to non -service rated switches Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution"" or Nexus'" Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 313 enclosure', with - electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. * Non -service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. ISO /zoos GENERAC` 100-400 Amps, Single Phase Automatic Smart Transfer Switches Functions All timing and sensing functions originate in the generator controller Utilityvoltage drop-out............................................................................................................................................................................................._......................<6S% Timer to generator start..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer' Enginewarm up delay.................................................................................................................................................................................................................5 seconds Standbyvoltage sensor..................................................................................................................................................................................................65% for 5 seconds Utilityvoltage pickup.........................................................................................................................................................................................................................>80% Re -transfer time delay............................................................................................................................................................................................................... 15 seconds Enginecool -down timer............................................................................................................................................................................................................60 seconds Exerciser..............................................................................................................................................................5 or 12 minutes adjustable weekly/Ri-weekly/Monthly'• The transfer switch can be operated manually without power applied. 'When used in conjunction with units utilizing Evolution- controls "Adjustable via the controller Specifications Model RXSC100A3 RXSW100A3 RXSW15OA3 RXSC20OA3 RXSW200A3 RXSW30OA3 RXSG400A3 RXSW40OA3 Amps 100 100 150 200 200 300 400 400 Voltage 120/240, 10 120/240, to 120/240, 10 120/240, to 120/240, 10 120/240, to 120/240, to 120/240, to Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 3R NEMA/UL 313 NEM1A/UL 311 NEMtA/UL 3R NEMA7UL 3R NEM1A/UL 311 NEMA/UL 3R NEMA/11L 311 UL Rating UUCUL UL UL UUCUL UL UL UUCUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug Range 1/0 - #14 250 MGM - #6 600 MC - #4 or 1/0 - 250 MGM Dimensions R Model RXSC100A3 8XSWIGGA3 RXSWl50A3 RXSC200A3 RXSW20oA3 RXSW300A3 RXSC400A3 RXSW40OA3 Height Hit17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.76/679.4 42.91/1089.9 31.25/793.8 42.91/1089.9 (inJmm) H2 20/508 20/508 30/762 201508 30/762 48/1219.2 36/914.4 4811219.2 Width Wl 12.5/317.5 12.5/317.5 10.5266.7 12.5/317.5 10.51266.7 16.69/423.9 19.181487.2 16.69/423.9 (inJmm) W2 146/370.8 14.61370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.821554.2 24/609.6 21.82/654.2 DepN (inJmm) 7.09/180.1 7.09/180.1 6.3/160.1 7.09/180.1 6.31160.1 10.06255.5 10.06255.5 10.06255.6 Weignt (Ibslkilas) 20/9.07 22.5/10.21 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 GE N ERAC Generac Power Systems, Inc. - S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ®2017 Generic Power Systems, Inc. A0 rights reserved. All specifications are sublect to change without Police. Bulletin 10000013459-A 04/24/17