Loading...
HomeMy WebLinkAboutPLANSe • (J RECEIVED JUL 18 2019 ��a �@IB @Wmtys r#IrmIfEld�' 43 ft. 11 in. 437 ft. 0 in. PROPERTY LINE \+ \ LU z o.\\ P\ A \ Q Z b �,... 'pO \ iy 0\ oo 10 0 O m q C7 c0 \ Gam\ o J O g\ Z W0 J +\ LLI \4 p8 W \ \ '� POOL EgUIPflAENT c 39 ft. 8 in. C LOCATION r 424ft.5in. PROPERTYLINE SCANNED SLuclec t.ounty REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC F f l FCOPV POOLDESIGN.NET op 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954)941-1124 info@swimm 1 ng pool plan, com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454, 2, 6,6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2017 Sth EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSINSPI 3, ANSIINSPI 5, ANSIIAPSP 7,ANSI/APSPIICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF, 3)THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318.11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITEISHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A T.S.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. g) PIPING'. ALL POOL PIPING SHALL BEAR THE N. S. F: PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P. V, C. MIN. POOL PIPING TO COMPLY WITH F.8.0 C. POOL EQUIPMENT TO APPLY TO F.8.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F, B.C. g) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 680, 25(C) ` ••� SF ••• +4•9 •at • ` :W2 STPI ., 'y��.••.FL o.P`��.�d:�. S. M. AKERS P.E. 68449 SITE PLAN — 1 TITLE LOT 3 VENETIAN ADMINISTRATION LLC DESCRIPTION 4422 N. HWY Al FT. PIERCE,FL.34949 Scale: 1 in = 30ft. Oin. DATE 7/10/2019 PAGE 1 OF 5 IIN POOLDESIGNNET ^m TOP OF POOL EQUIPMENT SLAB TO BE INSTALLED AT BASE FLOOD ELEVATION +1' loft. E PROVIDE MIN. 42" BARRIER BY OTHERS PER PERMIT #1901-0543 5' SUN FOUNTAIN TOP OF POOL EL.23, DEC-O-DRAIN DIMENSIONS TAKEN @ WATERLINE i -24" 11 ft. 4 in.—'Ik 6 Tr 4-e 0 • POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954)941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R41III,&I ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2W RESIDENTIAL SWIMMING BARRIER REQUIREMENTS PROVIDE MIN. 42" BARRIER BY OTHERS REVISIONS PER PERMIT #1901-0543 m '0 1) PLANS DESIGNED PER 2017 8th EDITION F.B.C. RESIDENTIAL e CHAPTERS 42 8 45 and ANSUNSPI 3, ANSUNSPI 5, ANSI/APBP 7,ANSI/APSPACC 15 °T 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PER 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. = dd SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK 12V LED LIGHT ---�� OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM r CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE 3R. iR, 1 k. 1 NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. �gP 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. 1 I I CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNrrE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A.T.S. M: 15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.0 I. STANDARDS AND SPECIFICATIONS. 5 ft. 3 in. i PIPING' ALL POOL PIPING SHALL BEAR THE N.S.F-PW SEAL 23 ft. 4 In. OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F. B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC II + WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iN F.S.C. (I 'K 8) EQUIPOTENDAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 680.28(C) SLOPE POOL DECK 1/8" PER AWAY FROM POOL RE*IEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCCi�....__ NOTES: IF WATER SOURCE IS A PRIVATE WELL PREFILTER WATER TO FILL POOL ALL METALLIC ITEMS WITHIN 5'.0" OF WATERS EDGE OF POOL TO BE BONDED WITH #8 SOLID INSULATED WIRE (W. listed) FROM POOL STEEL. ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS ,... G, F.I, OUTLET 10 •. ,� • N 5e�� • IIe�� � S844 = MIN. AND 20' MAX. FROM POOL e IF PROPERTY ENCLOSURE IS REQUIRED ADD SCREEN OR FENCE AROUND POOL OR �' = e Q i GATES TO BE SELF CLOSING AND SELF LATCHING �9: STATE OF PROVIDE DOOR AND WINDOW ALARMS AS REQUIRED STEEL OVERLAP@ 48 TIMES DIAMETER 100 �j •��•�� Q' O Ft`•••� ,,�� LOTS ESTABLISH THE LOCATION OF ALL UTILITIES AT SWIMMING POOL CONSTRUCTIONSITE S • AND HOLBY THE LOCAL REGULATORYDAGENCMINIMUYt ALLOW CMININ10' CLEARANCE 811NA„tip HORIZONTALI FROM OVERHEAD ELECTRIC LINES TO POOL WATER, DECK SHALL HAVE A SLIP RESISTANT FINISH WITH NO SHARP EDGES AND BE B•M. AKERS POSITIVELY SLOPED FOR DRAINAGE P.E. 68449 PROVIDE WEEP HOLES AND DEWATERING PUMPS AND ANY OTHER METHODS NECESSARY TO PREVENT THE POSSIBILITY OF THE POOL FLOATING DUE TO LAYOUT PLAN HYDROSTATIC UPLIFT PRESSURE WHEN THE POOL IS EMPTY, BACKFILLING OF THE POOL SHALL BE DONE CAREFULLY TO ASSURE THAT NO DAMAGE TO THE PIPING OCCURS AND BACKFILLING SHALL BE DONE WITH LOT 3 VENETIAN ADMINISTRATION LLC CLEAN SOIL FREE FROM ORGANICS AND DEBRIS AND SHALL BE COMPACTED SO DESCRIPTION THAT NO VOIDS EXIST PROVIDING A FIRM BEARING FOR THE DECK ALL PIPING TO BE PVC SCHEDULE 40 MINIMUM AND ALL PRESSURE PIPING AND 4422 N. HWY A1A MAIN DRAIN PIPING MUST SE PRESSURE TESTED PRIOR TO GUNITE(CONCRETE) FT. PIERCE FL.34949 Scale: 1/4"= l'-0" THIS IS NOT A DIVING POOL. SWIMMING POOL FILL HOSE TO BE EQUIPPED WITH VACUUM BREAKER DATE 7/10/2019 LOCATE POOL RETURNS DOWN 18" MIN. BELOW THE POOL BEAM PAGE I -- - PIPING NOTES ALL PIPING TO BE PVC SCHEDULE .r MINIMUM AND ALL PRESSURE PIPING AND MAIN DRAIN PIPING MUST BE PRESSURE TESTED PRIOR TO GUNITE (CONCRETE) PROVIDE 5 PIPE DIAMETERS CLEAR LENGTH BEFORE PUMPS ON SUCTION SIDE LABEL ALL VALVES AND PIPES PIPING TO BE INSTALLED 18" MIN BELOW GRADE AND TRENCHES TO BE CONDUIT FOR WATER LEVELOR TO BACKFILLED W/ CLEAN SAND SOLENOID WATER SUPPLY WELL WATER: IF POOL IS TO BE FILLED WITH WELL WATER PROVIDE PREFILTER WHEN FILLING POOL AUTOFILL SENSOR IS IN TROUGH AND WATER IS ADDED TO POOL POOL EQUIPMENT LOCATION TOP OF POOL EQUIPMENT SLAB TO BE INSTALLED AT BASEFLOOD ELEVATION+1' , (16.4 NA VD) POOLDESIGNNET I I PIPING IS SHOWN j SPACED FOR CLARITY CONNECT SPA AIR LINE TO EACH THERAPY JET i I j sa. I � AUTO LEVEL CONDUIT :r-- — 3/4" AUTOFILL LINE��- 1-1/2" FOUNTAIN LINE G FOUNTAIN LIGHT CONDUIT ----- — — 2" VACUUM LINE o ----- ;— POOLLIGHTCONDUIT-- — — — — — —---------- 3" POOL MAIN DRAIN LINE ( — no, onn_c cl loot w I Info 2" T To M MAIN DRAW t .24- -01 -5'-0" OVERFLOW LINE CRITICAL: PROVIDE PLUMB AND ACCURATE LEVEL WATER LINE FOR NEGATIVE EDGE 04 OAP h +D„ 4.G Y MAIN DRAIN 5' SUN SHELF W FOUNTAINSUBBLER NOTE: LIGHTS MUST BE ' AMBER COLOR r - 1n 12V LED LIG ), 1a. eP I I I I I I O I 1 I v 1 ------------------------- I............... '-----------------------i-------------------.I Je — _... ______— ____ ___________1 ❑ CONCRETE DECK BY OTHERS MIN. 18" CLEAR FOR FUTURE - - - SOLAR IC40 CELL LEGEND: -RETURN LINE • ELEVATION NOTE: WATERBOND FITTING TO BE BELOW WATERLINE AT ALL TIMES -2-WAY VALVE ATER BOND FITTING PB2008 - 3-WAY VALVE - CHECK VALVE BUTTERFLY VALVE 2.1/3" POOL RETURN -SKIMMER pL� ILL - VALVE ACTUATOR 1-12" BUBBLER FILTER PAD DETAIL NTS NOT TO SCALE REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC T 3 HP PENTAIR 1-1/2 H.P. AIR PENTAIR VS PUMP BLOWER 1-1/2 H.P.V.S. .ram EDGE PUMP ro L_ FILTER d 0 H- y N CHECK VALVE Provide min. 4 times pipe z diam. clear straight length 0 U) 0 N p O CHECK z w z VALVE o w o z 2-1/2" SPA z iv JETS QzQ M --N ri R POOLDESIGNAET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6/R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2017 6th EDITION F, B. C. RESIDENTIAL CHAPTERS 42 & 45 and ANSIINSPI 3, ANSI/NSPI 5, ANSI/APSP TANSI/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PER 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS, SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A,C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3, 000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A. T.S.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C, I. STANDARDS AND SPECIFICATIONS. g) PIPING: ALL POOL PIPING SHALL BEAR THE N. S, F: PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P. V, C. MIN. POOL PIPING TO COMPLY WITH F.B.0 POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F, S. C, 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 680, 26(C) t of J^, 3 I • R 1 WOO j ri •9G �• STATE OF -014. B. M. AKERS P.E. 68449 PIPING PLAN TITLE LOT 3 VENETIAN ADMINISTRATION LLC DESCRIPTION 4422 N. HWY Al FT. PIERCE, FL.34949 Scale: 1/4" = V-0" DATE 7/10/2019 PAGE 3 OF 5 I (NOT �1 (NOTE BELOW) L�J / ELECTRIC 3 #121N 12" PANEL CONDUIT CONTROLLER 3#8THHN & 1 #101N 1"CON , GFI PUMP BREAKERS 3#121N 12"�� CONDUIT 220V MOTOR 1.5HP AIR BLOWER 4,5A 12v TRANSFORMER DECK BY OTHERS #8 AWG INSULATED COPPER _ WIRE EPDXY COATED _____---- _____________ LIGHT CORD (IN CONDUIT) ( #B AWG INSULATED COPPER WIRE EPDXY COATED PUMP I POOL PUMP MOTOR COMPLIES WITH 3HP VS 403.9 FBC ALL ELECTRICAL PER PENTAIR 2014 N.E.C. 16A ILL EQUIPMENT TO BE INSTALLED PER ✓IANUFACTURER SPECIFICATIONS ALL METALLIC ITEMS WITHIN 54" OF WA TER'S EDGE OF POOL TO BE BONDED WITH *8 SOLID INSULATED WIRE (UL listed) FROM POOL STEEL. ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS...... G.F.I. OUTLET 10' MIN. AND 20' MAX PPl14A Pnnl :ONCRETE DECK IYOTHERS EXPANSION JOINT (SEALED #4s @ 9" O/C BOTH WAYS DOUBLE MAT WITH 6#5 AND #3 HOOPS @ 12"O/C 12" FLOOR WITH #5 @ 12" O/C BOTH WAYS DOUBLE MAT NEGATIVE EDGE SECTION I Scale: nts L-� LBEND PILING STEEL INTO POOL FLOOR TYP. POOL SECTION Scale: nts POOLDESIGN. NET PILINGS By OTHERS 10'-6" VGB APPROVED MAIN DRAIN GRATE SECURED IN PLACE SO TOOLS — ARE REQUIRED FOR REMOVAL MAXIMUM FLOOR SLOPE —_ Ift. IN 7ft 12" FLOOR WITH #5 @ 12" O/C BOTH WAYS DOUBLE MAT PILING POOL SEE PILING PLAN COAT BOND CONNECTION WI APPROVED POTTING COMPOUND 12V UNDERWATER UL APPROVED LIGHT 10" WALLS WITH #4s @ 12" O/C HORIZONTAL & VERTICAL PLASTER FINISH 12" FLOOR WITH #5 @ 12" O/C BOTH WAYS. iD DOUBLE MAT POOL STEEL OVERLAP 0 48 TIMES DIAMETER STRUCTURAL DETAIL 2"SENSOR SLEEVE 2"OVERFLOW TO ORM m N V CONDUIT TO LEVOLOR BREAK AWAY WALL & FOUNDATION BY OTHERS PER PERMIT #1801-0543 GRADE BEAMS WITH 6 #5 AND #3 HOOPS @ 12" O/C ANTI -ENTRAPMENT 1. TIME SWITCH MUST BE INSTALLED TO ALLOW POOL OWNERS TO RUN THE POOL FIL TRATION PUMP ONLY DURING PEAK HOURS z AOUASTAR 2. POOL FILTRATION PIPING MUST BE SIZED SO THAT MAIN DRAIN 32COFL101 THE VELOCITY DOES NOT EXCEED 8FPS IN THE -316 GPM @ 3S FPS RETURN LINE AND 6FP3 IN THE SUCTION LINE. z FLOOR INSTALLATION 3. FILTER AREA BASED ON 6 HOUR TURN OVER 4. FILTER PUMPS - A MIN. OF 4 PIPE DIAMETERS SHALL BE INSTALLED BEFORE PUMP. 5. INLET FITTINGS SHALL BE DIRECTIONAL. .. 32 ' S. PROVIDE A MIN. IS" OF HORIZONTAL OR VERTICAL POOL/ SPA PIPE BETWEEN FILTER AND HEATER OR DEDICATED SUCTION AND RETURN LINES SHALL BE INSTALLED TO MAIN DRAIN DETAIL ALLOW FOR FUTURE ADDITION OF SOLAR HEATING EQUIPMENT. 8" WALL WITH #4s @ 12" O/C BOTH WAYS 12'FLOOR WITH #5 @ 12" 01C BOTH WAYS DOUBLE MAT WITH 6 #5 AND #3 HOOPS @ 12" O/C PILINGS BY OTHERS SPA SECTION Scale: nts r 1/4" TAP CON BOLTS 3" LONG @ (4) LOCATIONS 114' TAP CON BOLTS 1/4" TAP CON BOLTS 4" THICK CONCRETE SLAB ANCHORAGE DETAIL .---------, PUMP i POOL I I I PER 2014 NEC (680.26C 'EQUIPOTENTIAL BONDING GRID") 98 AWG WIRE 18" TO 24" HORIZONTALLY BEYOND THE 088AWG BARE SOLID COPPER BONDING JUMPER SHALL BE INSTALLED IN AT LEAST FOUR (4) LOCATIONS AROUND PERIMETER OF THE POOL OR SPA AND ATTACHED TO DECK STEEL W/ APPROVED GROUND LUGS. EQUIPOTENTIAL BONDING GRID 11 # 400 314" CLEVIS HANGERROD .4 SUPPORTS REBAR PIPE SUPPORTS 4' O/C ------ — 2" PVC 3,18" THREADED STEEL ROD 0400 CLEVIS HANGERS SIZE VARIES W/PIPE SIZE RETURN LINE LOOP 11 " PVC PIPING 4'-0" O/C MAX, WALL SECTION PIPING NTS REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY ROCC WRI/APQP-7 INE TYPE IZE LOW GPM PS AIN DRAIN LINE 1 3" 1 130 5.9 ETURN LINE 2-1l2"1 130 8.5 11 HERAPY JETS 1 2-1/2" 1 130 8.5 POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954)941-1124 info@swimmingpoolplan.com OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.61R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES, 1) PLANS DESIGNED PER 2017 6th EDITION RE C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSP 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT, 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/ SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS GRADE 60 OR NEW BILLET STEEL CONFORMING TO A.T.S.M: 15. STEEL SHALL BE BENT LAPPED, AND PLACED IN ACCORDANCE WITH A CJ STANDARDS AND SPECIFICATIONS. 8) PIPING, ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN, POOL PIPING TO COMPLY WITH F.B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SI'OPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NU CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iNF.SC. 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 381 .• .•� ENs'••. �;� r • 0 684410 STATE OF S f It i` •• < 0 10 R 84A 111111111 S. M. AKERS P.E. 68449 DETAILS TITLE LOT 3 VENETIAN ADMINISTRATION LLC DESCRIPTION 4422 N. HWY A1A FT. PIERCE FL.34949 Scale: 1/4" = V-0" DATE 7/10/2019 PAGE 4 OF 5 PILE GROUT MIN, 5000 PSI @ 28 DA) (13) 16"ROUND AUGER -CAST 12"FLOOR WITH DOUBLE MAT CONC. PILINGS 35TON ass @ 12' O/C BOTH WAYS COMPRESSION CAPACITY INSTALLED TO 30' BGL OR REFUSAL 3k (BY OTHERS) I I I I I I 6 # 6(s) — I _I ___ _ 18" QIAM. AUGER _ CAST PILE PROVIDE SONG TUBE TO EXTEND PILE ABOVE GRADE TO POOL SLAB ELEVATION ALL PILES TYP, _#3-8" X 8" HOOPS @ 8" O/C LENGTH OF PILE 1-ml 1=1 PILING& PADS ECTIO N VIEW NTS POOLDESIGNNET L —_J L_ —J 16" DIAM. AUGER CAST PILE #5 BARS @ 12" C/C BOTH WAYS IN POOL FLOOR 74 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC POOL.DESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA33060 (954)941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101 S I ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2017 6th EDITION F:B.C. RESIDENTIAL CHAPTERS 42 8 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSPIICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT, 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO AT S. M: 15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 6) PIPING. ALL POOL PIPING SHALL BEAR THE N.S.F. -PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH PE C POOL EOUIPMENTTO APPLY TO F, B, C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F, B.C. 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 680.26(C) SyB 6844NSF 1,- _ -v. rt� -9t S1ATE OF -'All/: � B. P.E. 68449 PILING PAGE TITLE LOT 3 VENETIAN ADMINISTRATION LLC DESCRIPTION 4422 N. HWY Al FT. PIERCE FL34949 Scale: 3/8" = V-0" DATE 7/10/2019 PAGE 5 OF 5