MIAMl•[ulDE� �� Lucie13 ���� MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208
AFFAIRS (PERA) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) wwu.miamidade.eovhmra
Johns Manville Corporation
717 17th Street
Denver, CO 80202
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA -
Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Johns Manville APP Modified Bitumen Roofing Systems Over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 11-0223.06 and consists of pages 1 through 14.
The submitted documentation was reviewed by Jorge L. Acebo.
1011INEYL KOEH
Ptofctat WaWmeerPE-32833
7206 eyes Cbrle
Port St. Lucie, FL 349U-=
F" t (772) o.: 12-0123.02
Expiration Date: 06/14/13
Approval Date: 05/10/12
Page 1 of 14
ROOFING SYSTEM APPROVAL
Category:
Roofing
Sub -Category:
Modified Bitumen
Materials:
APP
Deck Type:
Wood
Maximum Design Pressure
-52.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE I
Test Product
Product
Dimensions Specification Description
JM APP Base
39-3/8" x 48' ASTM D 6509 APP modified asphalt, fiberglass
reinforced, smooth surfaced base sheet.
APPeX 4S
39-V8" x 34' ASTM D 6222, APP modified asphalt, polyester
type I, grade S reinforced, smooth surfaced membrane.
"VW APPeX 4.5M
39-3/8" x 34' ASTM D 6222, APP modified asphalt, polyester
type I grade G reinforced, mineral surfaced membrane.
APPeX 4.5MFR
39-3/8" x 34' ASTM D 6222, APP modified asphalt, polyester
type I grade G reinforced, fire -retardant, mineral surfaced
membrane.
Tricor MFR
39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced, granule surfaced membrane.
Tricor S
39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced; smooth surfaced membrane.
PermaPly 28
36" x 106; ASTM D 4601 Type II asphalt impregnated and coated
72 lb. roll glass fiber base sheet
Ventsulation
36" x 36' ASTM D 4897 Heavy duty fiber glass base sheet
Type II impregnated and coated on both sides with
asphalt with or without fine mineral
stabilizer.
APPROVED INSULATIONS:
TABLE 2
Product Name
Product Description Manufacturer
(With Current NOA)
ENRGY 3, 25-PSI
Isocyanurate Insulation. Johns Manville
Fesco Foam, DuraFoam
Isocyanurate Insulation with perlite facer Johns Manville
Retro-Fit Board, DuraBoard
A high -density perlite roof insulation. Johns Manville
Fesco Board
Rigid perlite roof insulation board. Johns Manville
Structodek
High Density Wood Fiber insulation board. Blue Ridge Fiberboard
NOA No.: 12-0123.02
Expiration Date: 06/14/13
Approval Date: 05/10/12
Page 2 of 14
APPROVED FASTENERS:
TABLE 3
Fastener Product
Product
Manufacturer
Number Name
Description
Dimensions
(With Current NOA)
mil. Ultral ast Fasteners
Insulation fastener for wood
Johns Manville
and steel.
2. UltraFast ASAP
Pre -assembled Insulation
Johns Manville
fastener and plate
I UltraFast 3" Round Metal
Galvalume AZ55 steel plate
3" round &
Johns Manville
Plate or Square Recessed
3" square
Metal Plate
4. Olympic Fastener #12 &
insulation fastener
Olympic Mfg. Group
#14
5. ASAP Roofgrip
Pre -assembled Insulation
Olympic Mfg. Group
fastener and plate
6. OMG 3" Galvalume Steel
Galvalume AZ50 steel plate
3" round
Olympic Mfg. Group
Plate
7. Tru-Fast HD Fastener
Insulation fastener for steel
The Tru-Fast Corp.
(414)
and wood decks
8. Tru-Fast 3" Metal
Galvalume AZ55 steel plate
3" round
The Tru-Fast Corp.
Insulation Plate
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Description
Date
Factory Mutual Research Corp.
J.1. OXOA9.AM
4470
03/25/94
J.I.0W6A2.AM
4470
02/05/93
J.I.OX7A4.AM
4470
08/26/93
J.1.3001482
4470
08/11/98
J.J.3002823
4470
04/01/99
J.1.3003468
4470
02/02/00
J.1.3007148
4470
04/19/00
3009499
4470
04/04/01
3011248
4470
11/01/02
3012974
4450
06/03/02-
Underwriters Laboratories, Inc.
R-10400
UL 790
Published
Annually
Exterior Research & Design, LLC
#4361-2.04.97-1 TAS 114(J) — Wind
Uplift 04/15/97
10390A.12.97-1 TAS 114(J) —Wind
Uplift 1.2/15/97
10390A.10.97-1 TAS I I4(J) —Wind
Uplift 10/15/97
10391.01.03 TAS 114(J)
& TAS 117
(B) 01/29/03
NOA No.: 12-0123.02
Expiration Date: 06/14/13
Approval Date: 05/10/12
Page 3 of 14
Membrane Type: APP
Deck Type 11: Wood, Insulated
Deck Description: v i9/3_" or greater plywood or wood plank
System Type D: v1 All insulation is loose laid with preliminary attachment to roof deck. Membrane
and/or anchor sheet is subsequently mechanically fastened through insulation to
the roof deck.
All General and System limitations apply.
One or more layers of any of the following insulations
Base Insulation Layer
ENRGY 3, 25-PSI, Fesco Foam, DuraFoam
Minimum 1.5" thick
Fesco Board
Minimum'/" thick
Retro-Fit Board, DuraBoard
Minimum %" thick
Insulation Fasteners Fastener
(Table 3) Density/ftt
N/A N/A
N/A N/A
N/A N/A
Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor
sheet, at a minimum application rate of two fasteners per board for insulation boards having no
dimension greater than 4 ft, and four fasteners for any insulation board having no dimension
greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See
base/anchor sheet below for fasteners and density.
Base Sheet: (Option #1) One ply of JM APP Base, PermaPly 28, Glasbase Plus or JM
Ventsulation mechanically fastened through the insulation to the deck with JM
UltraFast, Olympic or Tm-Fast metal plates and fasteners at a 4" side lap 12" o.c.
and two rows staggered in the center of the sheet 18" o.c.
(Maximum Design Pressure: —45 psf, See General Limitation 49.)
/
�/ (Option #2) Minimum two plies of JM PermaPly 28 or JM Ventsulation
simultaneously fastened ihrou o t e deck with JM Ultrafast
fasteners and Metal Plates spaced 9" o.c. in a 4" lap and 12" o.c. in two staggered
rows in the center of the sheet. el
(Maximum Design Pressure: —52.5 psf, See General Limitation #7.)
Ply et: (Optional) One or more plies of JM APP Base or APPeX 4S heat welded to base
sheet.
Membrane: v One or more plies of APPeX 4S, APPeX 4.5M or APPeX 4.5 MFR heat welded
NOA No.: 12-0123.02
Expiration Date: 06/14/13
Miarn-oaDecoUNTY Approval Date: 05/10/12
NNW Page 11 of 14
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor
sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using
the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum
design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 Ibf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchoribase sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
� calculations in compliance with Roofing Application Standard RAS 117.
/7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not be
applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall
conform to Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not be
applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 9N-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 12-0123.02
Expiration Date: 06/14/13
Approval Date: 05/10/12
Page 14 of 14
MI®E
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTM15NT (81413
BOARD AND CODE ADMINISTRATION DIVISION ''!
NOTICE OF OF ACCEPTANCE (N(
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43659
buANNEL)
BY
St. Lucie Count,
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
4786) 315-2590 F (786) 315-2599
SCOPE:
This NOA is being issued under the applicable.rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIMON: Oakridge® Shingle
LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 10-1015.01 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11-0411.03
Expiration Date: 02/03/16
Approval Date: 06/16/11
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Category
Roofing
Sub-Cateeorv:
Asphalt Shingles
Materials
Laminate
DeckType:
Wood
SCOPE
This a- roves a roofin -s stemasin Owens Cornin-Oakrid e® asphalt shingles Owens-
Corning gY g g g P g Y ---
Corning as described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product
Dimensions
Test
Product Description
Specifications
Oakridgeg
13 ''/V x 393/a"
TAS 110
A heavy weight, fiberglass reinforced
Manufacturing
laminate asphalt shingle with continuous
Locations #1, 2, 3, 4
bead of sealant.
Oakridge®
13 ''/4" x 39'/8'
TAS 110
A heavy weight, fiberglass reinforced
Manufacturing
laminate asphalt shingle with dashed bead of
Location #1, 3,4
sealant.
MANUFACTURING LOCATION
1. Memphis, TN
2. Irving, TX
3. Savannah, GA
4. Jacksonville, FL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
PRI Construction Materials Technologies
OCF-153-02-01
TAS 100
09/22/10
PRI Construction Materials Technologies
OCF-152-02-01
TAS 100
09/21/10
PRI Construction Materials Technologies
OCF-158-02-01
TAS 100
11/10/10
PRI Construction Materials Technologies.
OCF-151-02-01
TAS 100
09/27/10
PRI Construction Materials Technologies
OCF-150-02-01
TAS 100
09/21/10
PRj Construction Materials Technologies
OCF-165-02-01
TAS 100
01/07/11
PRI Construction Materials Technologies
OCF-170-02-01
TAS 100
06/06/11
Underwriters Laboratories
09NK14530
ASTM D 3462
12/31/09
Underwriters Laboratories "
R2453
ASTM D 3462
10/11/10
Underwriters Laboratories
R2453
ASTM D 3462
11/03/10
Underwriters Laboratories
R2453
ASTM D 3462
10/11/10
Underwriters Laboratories
R2453
ASTM D 3462
10/11/10
Underwriters Laboratories
R2453
ASTM E 108
01/13/11
Underwriters Laboratories
R2453
ASTM E 108
10/11/10
Underwriters Laboratories
R2453
ASTM E 108
11/03/10
NOA No.:
11-0411.03
MMM4D"E COUNTY
Expiration Date: 02/03/16
Approval Date: 06/16/11
Page 2 of 4
Underwriters Laboratories
R2453
ASTM E 108
10/11/10
Underwriters Laboratories
R2453
ASTM E 108
10/11/10
Underwriters Laboratories
09NK14530
TAS 107 (ASTM D 3161)
12/31/09
Underwriters Laboratories
OINK44201
TAS 107 (ASTM D 3161)
09/09/02
Underwriters Laboratories
1ONK13947
TAS 107 (ASTM D 3161)
11/12/10
Underwriters Laboratories
R2453
TAS 107 (ASTM D 3161)
10/11/10
Underwriters Laboratories
03NK04954
TAS 107 (ASTM D 3161)
03/07/03
Underwriters Laboratories
IONK13947
TAS 107 (ASTM D 3161)
01/28/11
Underwriters Laboratories
11CA15662
TAS 107 (ASTMD'3161)
05/27/11
LINIITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 911-72 of the Florida Administrative Code.
INSTALLATION
l . Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
5. Nailing shall be in compliance with Detail V, attached. .
LABELING
1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product Control Approved".
MIAMI•DADE COUNTY
.I m
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1,2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 11-0411.03
Expiration Date: 02/03/16
Approval Date: 06/16/11
Page 3 of 4
DETAIL A
DETAIL B
OWENS CORNING OAKRIDGE
WITH CONTINUOUS OR DASHED SEALANT
END OF THIS ACCEPTANCE