HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVITSCANNED RECEIVED
NVR -Business Use Only
BY
Planning &Development Services Departmen
tlu eCouo SEP 11 2019
Building & Regulations Division _
Product Review Affidavit ST. Lucie County, Permitting
Building Permit # 1907-0456 Owners Name: NVR Inc DBA Ryan Homes Applicant: NVR Inc DBA Ryan Homes
Product
Opening
Design
Pressures
Product
Rated
Design
Pressure
Manufacturer
Model#
Product
Approval
Number
Glass Type
Method of Attachment
Windows 3,4, 6 & 7
+28.2/-35.2
+50.2/-50.2
PGT Industries
SH-200
17-0630.02
non -Impact
# 10 Wood Screw with sufficient length to achieve 2-1/4"embedment. Required anchors: Head (3), Jamb (3)
Windows 8 & 9
+32.6/-42.6
+50.2/-50.2
PGT Industries
SH-200
17-0630.02
non -Impact
# 10 Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head (3), Jamb (3)
Mullions
N/A
+/-75
PGT Industries
PGT
17-0630.01
N/A
Use Y." Tapcon with sufficient length to achieve a l Y.'min. embedment with 2 A" minimum edge distance
Sliding Glass Doors
+30.4/-34.3
+35.3/-89.6
PGT Industries
SGD-2500
19-0219.11
non -impact
3/16" Tapcon with sufficient length to achieve 1-1/4"embedment. Required anchors: Head/Silt (6), Jamb(5)
Swing Type Doors
+32.0/-34.8
+67.0/-67.0
Therma Tru
31ON810"
FL 5891.5
N/A
ITW Tapcon Y", Min Embedment 1-1/4", Min Clearance to edge 2, Min Clearance to adjacent anchor 4"; OR ELCO
Tapcon 1/4", Min Embedment 1-1/4, Min Clearance to edge 1", Min Clearance to adjacent anchor 4". Anchor
Spacing Max 18.5" O.0
Garage Doors
+28.2/-34.33
+36/42
Clopay
16x7 model 73WG
FL 16546.4
N/A
Jamb a block on vertical Jam min embedded Iapcon. Max spacingo andl uusteelwasher
required.
Hurricane Protection
N/A
+40/-40
Eastern Metal
24ga Steel Panels
FL 11964.2
N/A
1/4"Tapcon Anchors, SG Tapcon or 1/4"X3/4". All points Solid -set Anchors.
Roofing Material
N/A
N/A
Tanaka
N/A
FL 18355.1
N/A
Soffits (Panel Walls)
N/A
N/A
I Ply Gem
Mastic Soffits
FL 23352.1
N/A
Structural Component
N/A
N/A
IHuberEng.
ZIP System
FL 17147.1
N/A
I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions.
Name: James Joseph Cantwell Signature:
Design Prof: Architect Cert.-No. ARD012079 Date:
seal
A
Building Permit #
Planning & Development Services Department
Building & Regulations Division p�
Product Review Affidavit GAWKEDY
��oott6���d p
Applicant: NVR Inc DBA Ryan Home�LL. LuelevolffitY
Owners Name: NVR Inc DBA Ryan Homes
NVR- Business Use Only
Product
Opening
Design
Pressures
Product
Rated
Design
Pressure
Manufacturer
Model#
Product
Approval
Number
Glass Type
Method of Attachment
Windows
+32.37/-42.62
+50.2/-50.2
PGTlndustries
SH-200
17-0630.02
non -impact
# 30 Wood Screw with sufficient length to achieve 1-1/4"embedment. Required anchors: Head(3), Jamb(3)
Mullions
N/A 1
+/-75
PGTlndustries
PGT
17-0630.01
N/A
Use Y." Tapcon with sufficient length to achieve a l Y."min. embedment with 2 Y," minimum edge distance
Fixed Glass
+29.65/-38.87
+/-58.9
PGTlndustries
PW-220
17-0614.05
non -Impact
# 10 Wood Screw with sufficient length to achieve 1-1/4"embedment. Required anchors: Head(3), Jamb(3)
Sliding Glass Doors
+28.74/-02.62
+35.3/-89.6
PGTInd ustries
SGD-2500
19-0219.11
non -Impact
3/16"Tapcon with sufficient length to achieve 1-1/4' embedment. Required anchors: Head/Sill(6), Jamb(5)
Swing Type Doors
+30.64/-30.64
+67.0/-67.0
Therma Tru
3'0"00"
FL 5891.5
N/A
ITW Tapcon Y.", Min Embedment 1-1/4, Min Clearance to edge 2", Min Clearance to adjacent anchor4' OR ELCO
Tapcon 1/4", Min Embedment 1-1/4, Min Clearance to edge 1", Min Clearance to adjacent anchor 4. Anchor
Spacing Max 18.5" O.c
Garage Doors
+25.91/-31.39
+36/-42
Clopay
16x7 model 73W6
FL 16546.4
N/A
Jamb to block on vertical jamb 1/4" X 11/4" min embedded Tapcon. Max spacing of 71/2" and 1" OD steel washer
required.
Hurricane Protection
N/A
+40/-00
Eastern Metal
24ga Steel Panels
FL 11964.2
N/A
1/4"Tapcon Anchors, SG Tapcon or 1/4"X3/4". All points Solidaet Anchors.
Roofing Material
N/A
N/A
Tamko
N/A
FL 18355.1
N/A
Sofgts(Panel Walls)
N/A
N/A
Ply Gem
Mastic Soffits
FL23352.1
N/A
Structural Component
N/A
N/A
Huber Eng.
ZIP System
FL 17147.1
N/A
I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions.
Name: James Joseph Cantwell DO
Design. Prof: Architect Cert. No. AR0012079 Date:_8132019 en\ �
q 0 M
p�
r m
01 0 O
�® �®
C 0
m