FLORIDA ENERGY E'FFICIENCY,CODE FOR -BUILDING CONSTRUCTION
Florida Department of'Business°and Professional Regulation - Residential Performance Method
A
Project Name:` CRUZ RESIDENCE
Builder Name:
�(�AAIAI�p�,
SCANNED
street' 6402 HICKORY DRIVE_LOT 2
Permit Office: TST LUCIE COUNTY
City, Stale, Zip:. FORT PIERCE, FL,
Permit Number.
P
Owner.
Jurisdiction: ST LUCIE COUNTY
�� r�
Location: FL, Fort Pierce
Design Location:
County: St. Lucie (Florida Climate Zone
Ga.'1e
��
12 Vll
1., New construction oaedsting New (From Plans)
9. Wall Types (2538.7 sgfl.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul. Exterior
R-4.1 2342.70 fP
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 196.00 ft-
c. NIA
R- fP
4. Number of Bedrooms 4
d. NIA
R= ft'
5. Is this a worst case? No
10. Ceiling Types (2529.0 soft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2529.00 ft'
6. Conditioned floor area above grade (ft-) 2529
b. NIA
R- ft,
Condltionedfioor area below grade (ft-) 0
c. NIA
R- ft,
7. Windows(285.0,sgft.) Description Area
11. Ducts
a. Sup: Attie, Ret: Attic, AH: AHU CLST
R fP
6 200
a.. U-Factor. Sgl, U=0.65. 221.00 ft-
SHGC: SHGC=025 ..
to. U-Factor 'S91, U=0.70 64.00 ft-
12• Cooling systems
kBtulhr .Efficiency
SHGC: SHGC=0,30
a. Central Unit
46.5 SEER:16.00
c. U-Factor: NIA 0
SHGC:
13. Heating systems
kBtulhr Efficiency
it. U-Factor. NIA fl'
a.. ElectricStrip Heat
34.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 2.000' ft.
Area,Weighted:Awrage SHGC: 0,261
14. Hob water systems
8. FloorTypes (2529:0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation
on R=0!0 2529.ODft'
b. Conservation features
EF: 0.980
b. NIA R= ft'
None
c. NIA R= ft'
15. Credits
None
Glass/FloorArea: 0.113 Total Proposed Modified Loads: 82.19
��
PASS
Total Baseline
Loads: 85.11
I hereby certify that.the plans and specifipations covered by
-Review of the plans and
'ej%ESr.4
this calculation are in compliance, with the.Florida,Energy
specifications covered by this
vO� • e e 60�,
Code.
calculation indicates compliance
y� Jr _ :r`
with'the Florida:Energy Code.
iit, "I", .F r g to
PREPA D Y:
Before construction Is completed
Wit
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Ener de.
f Otg ➢ r.,
OWNER... NT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In,accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R4®9VIIEgAgE® FOR
p
CODE COMPLIAPJCE
ST= La CM COUNTY
.3A1201912:17 PM - EnergyGauge®USA Section R405.4.1 Compliant Software DOCC Paged of
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
0
0
0
>T
z
>
Z
>T
z
z
z
E
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
E
E
Y.
n
0
O
O
0
O
O
O
O
O
O
O
n
0
0
o
LLI
M,�
0
Z O Z Z
IL
6
0
0
0
0
0
0
z
a
z
0
z
0
z
<
z
z
z
Z;
"Z
z
z
z
z
z
z
z
z
z
z
z
z
E oi. 2,A u <
S-6
E
QP
.9
R
0: C)
co
ri)
<
CL
<
z
in
z z z 0
w D � c
a 00 -2
tu w w m
E5
r
co
0
z
0
0.
0
0
0
D b
cc
w
0
0'
0
N
D
z
Z
Z
0:
co
cmi z co
t:
Lu
w
w
>
0
0
Z 42 z C)
Z
Z
—
-
—
—
—
—
—
—
—
m 0 ft M z 0
0
LL
Im
O
w
W
d
m
+Tc
N
8D?�i
8
0'
0
—
y
.
''4Wdq�
I
''i?dN�'-
fqw�
:
'
'
."Du •
n
'm'Q
(A
V
Vo—f—
N
N
N
q
'(of,�O
.yWdqJ�
^
dooW5•
mONNq
..Q.4yfdq�/))
.
O
O
O
Q
O
Q
O
O
O
O
Q
O .�y
O
O
IO
O
OO
•..00iok
-
9x,
m
4mfSA
-
J
?
?
7'
?
?
?
J?.'
o
.�I'G)
' m
G)
G)
G)
G)
G)
G)
G)
G7
Oa8%l
.;
4Ny
,.
m.
.
m
m
m'
m'
m
m
m
ro
m
m
m
ro
,n
m.
0
m
a
a
n"
fin.
n'
n
n
a'
n
n
n
n
n
'mn'
n
n'
C
C
Ei'
C,
G.
C
C
E.
G.
C
.0
IC
C
'o
n:
m
m
a
o
0
0
o
o:
'o.
.,.
o
0
05,
o
o
o
�..
.,o
o
C
d
�
T
'
I
:$'
p
'C
n.
�_.
...�.
.6
O
-Di
D'
'.y
-Di
A
.<
L)
Z
P
��
��
%
A
O
N
A
W
3.r
�•
f~i1.•'�
Z
.'G)'
'm
Dp
p
,
m
m
ro
�
r-
v
T
m
�.
s
�
98
�
o g
�
3
m
N
I
71
�
Z
[v
o
m
�
m
O
o
io
3
o
� c
NO
O
% m
C
F
Q
0
0
0
0
0
0
0
0
0
0
0
0
o
O
o
0
0
0
0
0
0
0
d
9
N
m �
3^
o
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
aoi
m
m
8
8
8
8 '8
8
8
8
8
8
8
8
8
8
8
8
8
8
0
0
0
0
0
0
0
0
0
0
0
0
0
o
0
o
m
o
3
3
3
3
3
3
3
3 3
3
3
3
3
3
3
3
3
3
3
3
3
~
c
m
m
E
O
O
O
O
O
O
O
O
O
O
O
O
O
N
O
'N
O
O
U
m
C
O
m
IL
W
Ol
�3
m.
IL.
t
m
to
m
Y
m
v
v
a
v
e
o
0
0
0
0
0
0
o
v
o
v
v
e
�
L
m
c
c
c
c
d
.
mi m
m
m
m
m
m
m
m
m
m
m
m
E„
J
.Ul..
>
e
m
�<
m
m
�
.r-
�
N
.•O
of
�
m
�
�
N
m
.(7
m
N
N
m
•n
ea
n
m
i'
W
w
N
N
m
N
m
N
nip n
to
ai
N
N
N
�v�
..
.-
.-
.-
=
v
v
v
v
U
p'r
}
r
m
rn
w
O
O
OW
m
J
a:>>
O
OZ
O
O
wZ
?w
�
m0
rm
C7
K=�
3
m
m
m
m
Z
S}j
r
0
0
Q
❑W
,m
LL
a
mm(
¢❑❑
Q�
J
W
W
JLL
m
m
m
N
O>>
"7m
V
iS
m
O'
J
N
N
N
_
4.
'y'
•Y'
o
o
E
E
o
0
0
0
8
0
0
Zo
_
m
0
m
0
m
0
m
0
m
m
m
m
m
m
mm'm,3
m
3
m.m
2
-8
E
E E
E
E
E
E
E
E
E
E
,E.,,
�.
U
D
U
U
U
U
U
U
A
U
`
c
m"
`w
"m
w`
•aS,
N
`m
`m. a`I'
N
a`T
`m
w
�
`m
`m'
U•I
�
N
`m
N
N
'
'.
L.
'C
'c
-c
'C
'C
'c
'c
'c'
•C
•C
•C
'C
l°
0
'e
m
'C
a
a
a
a
a
a
s
a. a
a
a
a
a
a
a.
a
a
a
a
b,
a
a,
j¢
a
m
W
m
w
y w
m
W
tt m�
pp'
m
m
W
A my
q m
qq,
m
m.�
m•
m
m
J'.
W
Wr
W
W
W
W
C9
W
Um
r
0
N
'�
o
N
z
w
3
3
'3
w
m
3
m
3
z
z
'N
t0
V
N
m
P
(O O•
o
cN,
h
N
N
p
L
TI
NI
NI
YI
ml
ml
nl
ml,
OII
OI
'I.
'I
'I
'I
ml
ml
f
ml
I
I
I
I
I
I
I
I
I
I I I
I
I
I
I
0
a
m
a
L
T
m
y
m
:E4z
m
z
m
m
m
0
z
m
m
m
m�
z
z
rn
w
z
0
3
X
jmI11 jmII
A ��A
R
I1
T
jmII
:A
j}1
9
T
T
D
o
OR
m
o
O O
o
o
O
o'
O
'n �.n'
0
0
0
0
'n
O
'-
>00
r
r
r
r
p
p
p
W�
'V
c
F
w
.E
m
m
m
m
m
m.:in
dm
m
,.m,.
m
m
m
m
',
�'
m
o °� o"
o
R
o
o
41
0
f�
41
'V�
M
0
4f
m
fA
;//J
fll
41
fn
n
n
R
0 ! 0
'o
m
p.
p
m"
m
m
J,
q
a
m
F
F :�FII
F
F1
Fm
Fmm
F
A
m
m
m
0
N
0
m.
m
CE
m
;m
m
N
(O
N
N
N
f0
d
m
N
•SDI
jjFmm
m
j
j
2S
10
O
..�5
S
A
Sri
tS
3:
.3
S
A
3
II
S.
A
S
3'
y
0
T
m
C.
a�is
C
m
C
E1
Fu
GJ
u
H
m
m
a
y
m
0
0
y
y
r1Di+
O
m,
S S
O
n
0
y
W
m�
O
O
O'
O
O
O
O
O
O
O
.O
O
O
m
A
'A •. A
A
A
A
A
A
A
m
H
ml
tT
W
tT
m
N
m
tT
er
N
m
ut
m
N
m.
(T.
J
O•
ut
0
.W
fn
O
ut
(n
i.
�.
's
N,
D
O
Z
+
a
W
r'.
o
0
0
0
0
0
o
o
.00
0
0
o
:.
i.
(T
(a
(Nll
W
ANT
U
'.
tNll
(NT
�
q�
cn
ONi
[T
N
in i
J:
m
T •.
Z.
Z.
[A
L
S
N
yOj
j
j
OO
o
o.
o
O
O
o
0
Z
Z
Z
z
Z
Z
Z'
Z
Z
'Z
Z
Z
Z
Z
9
n
m
m
N
p
N
t0 0
f0
•D
Ip
t0
f0
fD
J
=
_
m
O
O.
O
O
O
O
O
O
O
O
•O
O_
0
0�
m.
C
O
A. A
A
A
A
A
A
A
�
�p
.'1u'
1
"4
.'^.0
.Tu
'1u•
.Yu'
:2'
S
x.
.'yu
?
u
.Tu
m
�
?
�
d
O,
m
J>>>>
5
J
S
5•
>>
J
S
O
O
D O
O
O
O
O
O
O
O
J
K
J
m
Sc
O
O
W
m
T
='
Z
Z
Z
Z
Z
Z
Z
Z
2
s
O
J
O
J
O
J
O
J
O
J
0
J
O
J
'o
J
O
J
O
J
O
J
O
J
N
a
d
(O
1p
Q
mOC.
m
y
y
O
O O
O
01
O
m
O
m
O
W
O
W
O
T
p
y
Z
m
o
D
z
0
Z
0
Z
0
Z
0
Z
0
Z
0
Z
0
Z
p
z
0
Z
0
o
Z
0
Z
0
Z
o
m
�.
m
W
m
0
0 0
0
0
o
0
0
0
-FORM{11405 2017 MPL'IT-SUMMARY CHFCKUIST4REPORT. •'
INFILTRATiION %+
#` -Scope -" Method -
SLA- CFM^50`-, , ELA. EgLA ACH` _ACH,50
1 'Whotehouse,�, +R�oposedACH(50)-'.000475
3151.6. 173.02 325.38 .3754- 7
HEATINd'SY6TEM '
• - '# { System Type
Subtype' :Efficiency Capacity' Block
Ducts.
_ 1 - EleotAc'Strip HeatV
None COP:1 34. kBlu/hr 1'
sys#1
COOLING SYSTEM''
' - - -i.. ' System Type _
` -
Subtype `' Ek6lency '`.Capacity � AlrFlow __ - SHR Block'
-
- Ducts
._ 1 `'. Central UnIN
Split, SEER: 16 •48:5: kBluPor -1395 cfm,' 0:8, 1
sys#1
HOT WATER -SYSTEM
System Type_ Sub -type• --,
:'Location'..,,..- :EF- '- ;. 'Cap ;Use'- Setont -Conserva8on
'Elootng None
'Garage ,098 -' 10gel 62.3Igal'- 72Qdeg " - .'None.
`SOLAR'HOT.WATER'SYSTEM.
`'.FSEC.. -
,Cert# Company Name.
- : -, '- - - ' Collector • "Storage
System: Model# Collector Modell! Area Volume
'
FEF
,None' None -. - _
_ ,. ft-
., .. ,,. :.r, '..
..
' 'DUCTS '
--'Su pply-
# - Location R-Value,-Area
eturn— - ;' :Ali `CFM 25 •-.CFM25 _
,L=fon. Area. Leakage Type .Handler- -T,OT ,. OUT - ON RLF
-...
HVAC#
.Heat Cool
-
. -... 1 .. .,
,Attic 6:200:fF
Attic 0 fla,. .. ..
- , 20 , . � Default Leakage , AHU CLST (Defaulq c(Default) q.
. ,
1 1..
TEMPERATURES°
-
' Programable(T]hermostat:f N` • - ,,. -
'Heating` , H Jan- ;[X] Feb. : tX1 Mar
Venting I ]Jan' ,[tt III Feb , [�] Mar
�Alir C[[[eill1l Fens..4X]] EX]] [[X]]' ' r -
1�X7�
.Apr L I:May, l 1 Jun'. �x� Jul , l 1 Aug,` l 1 Sep S:p- Oct [X]`Nov
(r
` DDec
ec ` •
page of 7
N
no
mm
wn
mm
om
Om
mm
mm'
mn
mn
WW
mm
❑
C
2
N
P
9
W
0'
O
O
W
W
N
M
K
Q.
J
a
O.
m
p
Cc
O
mn
mn
mm'
wm
m
U
U
W
�-
Ut
>Oz-Q
U
Q
J
J'
jQ
Q
Q
W
J
m
m
m
¢
❑
LL
no
om
mm
mm
m
mn
mn
mw
mm
�
„
mm
mm
mm
mm
°�
nn
rr
mm
mm
a
m
LL�
m
m
m
th
m
M
m
m
m
N
N
m
m
m
co
o
ro
N
m
N
mm
n
nn
mm
o
x
ro
mm
mm
mm
mm
'
�_
nr
rn
mm
mm
,
on
_N
m
nn
mm
on
mo
mm
mm
y.
M1m
nm
no
mm'
on
mo
mm
mm
N
rm
M1m
mm
mm
on
on
tmm
mm
N
M1m
rm
mm
mm
U
�
C
m
'
m'
on
m0
mm.
mm
`a
M1m
'nm
mm
mm
-
o
0
'fig
w
2
CE
_
C
C
r
C
m
m
v
7/
:b
b
`
b
�$U
^N;
tiN
�N'..
N
N.
N
b
m
1T1
17/
N
N
�Y
s
:9
N
a
a
a
f�/
a
b
n
a
y�
a
a
'g
N
a
I\I/
s
n.
a
p
s
m
m
m
m
m
o
s
o
m
m�
m
m
m'. p,
❑
'W
❑
W
N
m
,m^
m
m
m
4
4
m'
m
m
4
4
4t
m
A
2
0
4
r
zz
22
m
`L
y
m
m
m
m
m
d
m
m
m
O
m
a`-i
❑
m
❑
m
❑
m
'❑
m
❑
❑
m
❑.
❑
m
❑
m, m.
G
G
❑
❑
O
❑
O.
❑
❑
❑
❑
❑
O
O
c.
c
c
E
41
E
m
z
Y
A
s
n
w
a
2017 - AIR BARRIER AND INSULATION INSPECTION. COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CRUZ RESIDENCE Builder Name:
Street: 5402 HICKORY DRIVE —LOT 2 Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: Jurisdiction: ST LUCIE COUNTY
W
x
.Design Location: FL, Fort Pierce
�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed In the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuousair barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Cellinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps In the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and slll plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavitywilh a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be Insulated.
Floors
The air barrier shall be installed, at any exposed edge of insulation.
.Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous Insulation Installed on the
underside of floor framing and extends from the botto
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crew] spaces. shall, be covered with a
Where provided instead of floor Insulation, insulation
Class I vapor retarder with overlapping joints taped..
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned s ace shall be sealed.
Batts In narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by Insulation that on Installation
readily conforms to the available cavity spaces.
Garage separation
Air sealingshall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light Mures Installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall
thermal envelope shall be air fight and IC rated.
Plumbing and wiring
Batt Insulation shall'be cut neatly to fit around wiring a
Plumbing In exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wirin .
Shower/tub.
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on'exterior wall
tubs shall separate them from the showers and tubs.
Insulated.
Electricallphone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be Installed.
HVAC register hoots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, Inspection of log walls shall be in accordance with the previsions of ICC-400.
3/11/2019 12:18 PM EnergyGauge® USA FBC 61h Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
'ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The IdWer the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location-& insulation
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R '6.0
- --- - - - _ c)AHU.location„ Attic-tAttic
3. No.+of units'=,(if multiple -family) 3. 1
4. Number of bedrooms 4. _. 4.
5. Is this a,worsi case? (yes/no) 5. _ No
6. Conditioned floor area,(sq. ft:) 6:. 2529
7. Windows, type and area
a) U-factor(weighted average) 7a. 0.661
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.261
c) Area 7c. 285.0
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) Bb. NA
9. Floor type, Insulation level:
a) `Slab -on -grade (R-value)
b) Wood, raised (R-value).
c) Concrete, raised (R-value)
10. Wall type;and insulation:
A. Exterior.
1. Wood frame (Insulation:R-value)
2. Masonry (Insulation R,value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation. level
a) Under attic
b) Single assembly
c) Knee walls/skylightwalls
d) Radiant barrier installed
9a. 0.0.
9b.
9c. _
10A1.
10A2. 4.1
10B1. 11.0.
10B2.-
11a. 30.0
1'1 b.
11 c.
11d. No
13'tooling system:
Capacity 46.5
a) Split
system
SEER 16.0
b)Single
:package
'SEER
c), Ground/water source SEER/COP
d)_Room unittPTAC
EER.
e) Other
14. Heating system: Capacity 34.0
a) Split system heat pump HSPF
b)-Single package heat pump HSPF
c) Electric resistance COP 1.0
d)'Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
c), Gas fired, LPG EF
d) Solar system with tank EF
a) Dedicated heat pump with tank EF_
f)-Heabrecovery unit . HeatRec%.
g) Other'
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizoneheating credit
0 Programmable thermostat No
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify,that this home has; complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which .will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature !% Imo) q
Address of New Home: 5402.HICKORY DRIVE LOT 2 City/FL Zip: FORT PIERCE. FL
3/111201912:18:08 PM EnergyCaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
D
9 . Project Summary Job:
wri htsoft P� � Date: Mar 71, 2019
Entire House ay:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772A6"796 Emag; ONCKCALCS@AOL.COM
Prodect Information
For. CRUZ RESIDENCE
5402 HICKORY DRIVE —LOT 2, FORT PIERCE, FL
Notes:
Design Information
Weather. Fort Pierce, FL, US
Winter Design Conditions
Outside db
Inside db
Design TO
Summer Design Conditions
42 OF Outside db
70 OF Inside db
28 OF Design TO
Daily range
Relative humidity
Moisture difference
Heating Summary
Structure 29260 Btuh
Ducts 8825 Btuh
Central vent (0 cfm) 0 Btuh
(none)
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 38085 Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
In
He ti
Co lln
Area ffl
2529
2529
Volume (ft')
27014
27014
Air chariges/hour
0.32
0.16
Equiv. AVF (cfm)
144
72
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
9.6 kW
32615 Btuh
19 OF
1550 cfm
0.041 cfm/Btuh
1.00 in H2O
90 OF
75 OF
15 OF
M
50 %
61 gr/lb
Sensible Cooling Equipment Load Sizing
Structure
23192
Btuh
Ducts
12580
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Ratelswing multiplier
Equipmenf sensible load
0.95
33984
Stuh
Latent Cooling Equipment Load Sizing
Structure
3009
Btuh
Ducts
3485
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
6495
Btuh
Equipment Total Load (Sen+Lat)
40479
Btuh
Req. total capacity at 0.70 SHR
4.0
ton
Cooling Equipment Summary
Make Rheem
Trade RHEEM
Cond RA1648AJlNA
Coil RH1T4821MTANJA
AHRI ref 8080956
Efficiency 13.0 EER,
16 SEER
Sensible cooling
32550
Btuh
Latent cooling
13950
Btuh
Total cooling
46500
Btuh
Actual airflow
1550
cfm
Air flow factor
0.043
cfm/Btuh
Static pressure
1.00
in H2O
Load sensible heat ratio
0.85
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
_-Fk wri9irtsoft- 2019-Mar-1112:16:12
' Right -Suite® Uniwmal201818.0.31 RSWB701 Page 1
.4CCA E:1Documtets\Wrightsoft HJAC\CRIR RESIDENCE.rup Cato = MJ8 Front Door faces: W
wrightsoft' Right-M Worksheet Job:
Entire House Date: Mar 11, 2019
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: Ol11CKCALCS@AOL.COM
1
2
3
4
5
Roam name
E�qosed wall
Room height
Room dimensions
Room area
Entire House
223.0 it
10.7 It
2529.0 ft-
M BATH
34.0 ft
9.3 It heal/cod
14.0 x 120 it
168.0 ft'
Ty
Construction
number
U-value
(Btuh1ftMF)
Or
HTM
(Btwft2)
Area (ftj
a perimeter ((t)
Load
(Stuh)
Area (ft�
or perimeter (ft)
Load
(Bluh)
Heal
Cod
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
11
-'
Uj1 C
1095
120
__ 360
959
_._.-190
1204
257
1459
--709
180
899
- .687
1337
257
784
356
207
4046
0
-130
0
,0
0
_,_ry:16
74
0
0
- "0
0
0
.. ; 0
112
0
0
16
0
168
168
! 114
0
0
0
-._.._0
74
0
0
0
'0
6
-. _ _:0
96
0
0
1
0
168
34
457
0
0
0
---291 _291
298
0
0
� - 0
0
0
_ ....,. _ 0
383
0
0
291
0
151
_ 1293
250
0
_ 0
0
. ,: 190
163
0
_ 0
0
0
0
_--o
_ 209
0
0
356
0
269
0
13A4acs
2 glazing cir Igwe
_2 glazng crr ION-e
2 glazing, dr love
2 glazing, cIr.Iw-a_
13A-0ocs
2 glazing, dr Ia
2gluing or taus
139-00cs -'� R
2 lazi dr lo4
2glazing,
lazing clr lm-
11130_,,.__._-.._..,_
13A4ocs
2 glazing, cir love
2 glazing, cir lox-e
2 glazing, dr lox-e
11D0-
16B-30ad.,,-" -
77Adph___
U.143
0.650
- "0.650
0.650
____0,650
0.143
0.650
0.650
n
n
n!'=
n
-_n_
a
a
a
4 00
18.20
9820
18.20
-1820
4.00
18.20
1820
-4
219
14.99
14:99
14.99
_ 11.B7
2-19
32-08
3242
812
8
-24
64
_.;.--.18
603
8
45
500
0
-- 0
0
0
550
1
_ 3
2663
146
-- 437
1165
-291
2203
146
819
�C
H�-(C
._
1N
`G
4143
0.650
am
-0.540
0.143
0.650
0.650
0.650
0.390
"0.032
1.358
s
5
s
_s_
w
w
w
w
-„w
_ .-_
-
00
1820
1820
_::-.15.12
4.00
18.20
18.20
18.20
_ 10.92
_ 0.90
38.02
219
14.99
14.99
___14.31
2-19
3208
3265
22.28
10.34
1.60
_ 0.00
444
12
60
_ __ .48
679
8
24
16
_ - 20
-.2529
_ ._ 2529
324
12
60
_-. _48
611
1
1
1
_ 20
2529
223
� 1297
..218
1092
_. .726
2446
146
437
291
_ 218
2266
_ _ 8479
-
W
C'_._.. ..
F
�
6
c)AED excursion
0
143
Envelope Imslgain
24826
15105
3164
1680
12
8) Infiltration
b) Roan ventilation
4433
0
1188
0
599
0
161
0
13
Internal gains: Occupants 230
Appliances/other
0
0
6900
0
0
0
Subtotal (lines 6 to 13)
29260
23192
3763
1740
14
15
Less odemal load
Less transfer
Redistribution
Subtotal
Dud loads
30%
54%
0
0
0
29260
8825
0
0
0
23192
12580
30%
54%
0
0
0
3763
1135
0
0
0
1740
944
Total room load
Air required(cfm)
38085
1550
35773
1S.
4898
199
2664
116
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
rt� wr19F+>=soFt- 2019-Mar-11 12:16:12
�A Right -Suite® Universal 2018 18.0.31 RSU08101 Page 1
E:1DocunoetslWdghtsoft HVAMCRLR RESIDENCE.nup Cate =We Front Door faces: W
r# wrightsoft• Right-JO Worksheet Job:
Entire House Date: Mar 11, 2019
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724668799 Fm 772466-6796 Emil: OUICKCALCSQ,AOL.COM
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
M TOILET
4.0 R
9.3 ft heavcod
7.0 x 4.0 If
28.0 fi'
HIS
0 It
9.3 R heal/cool
4.0 x 9.0 ft
36.0 It.
Ty
Construction
number
U-value
(BtLHftz°F)
Or
HTM
(Btuwft5
Area (ftj
or perimeter (ft)
Load
(Btuh)
Area (fly
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heal
Cool
e
11
_
_
l5J
L�--.---GG
r
....__
W
_4.1
F
0143
0650
0650
.0.650
0.650
0.143
0,650
0650
0.143
0.650
0.650
.,,---0.540
0.143
0.650
0.650
0.650
0.390
,,,��,0.032
1.358
n
n
n
n
- n..
a
a
a
s
s
s-
_5-
w
w
w
w
,w
;,
--400
1820
'1820
" 18.26
.,_ 18.20
4.00
18.20
1820
4 00
1820
1820
_,1512
4oD
18.20
18.20
18.20
10.92
-0.90
3802
279
14.99
14.99
14.99
_11.87
2.19
3208
32.42
219
14.99
- 14.99
_-_.14.31
219
3208
3265
22.28
_10.34
,_,.-1,60
0.00
0:^
0
0
0
0
0
0
0
0
- 0
0
-_.-..____0
37
8
0
0
0
0
0
- D
0
0
0
0
0
0
0
0
„__ __0
29
1
0
0
0
_,28
4
--_. 0
0
--'-0
0
0
0
0
_ 0
0
'0
0
__ _._.0
117
146
0
0
0
__.___25
152
_0
0
- -0
0
0
0
0
0
'0
0
0
64
257
0
0
_ 0
45,__.,_,.38,_-.,-_30.__,_..__.32
0
.__ .-'0
0
_ 0
0
,0
0
0
0
0,
'0
0
._.. __.0
0
0
0
0
0
36
_0
0..
_ 0__
0
_ 0
0
0
0
0
0
0
;._.. -.,-0
0
0
0
0
0
0
0
0
0_
- 0
0
0
0
0
0
0
0,
.__ <_.0
0
0
0
0
0
0
0
0
_ 0
,0
0
0
0
_0
0
0
0
-_ 0
0
0
0
0
_. _ 0
0
13A-0ocs
2glazing, dr lose
2 glazing Ur lcw-e
2 gluing, dr lower
2glazlrg_c!r.loN-e___
13A-4ocs
2glazing, cir lore
2glazing dr toys
ac 13A-0s
2 glazing, clr lcxe
2 glazing, clr Im"
,11G0-_,._,-____.-.,_
laklocs
2 glazing, dr ION-e
2 glazing, dr low-e
2 glazing, clr lc 9 e
11D0�
6BJ0ad,_
22A-tph
-__._28,
28
....
6
c)AED excursion
109
-2
Envelcpe loss/gain
1440
474
32
56
12
a) Infiltration
b) Room \entilation
71
0
19
0
0
0
0
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
0
0
0
0
Subtotal (lines 6 to 13)
510
493
32
56
14
15
Less edema) load
Less transfer
Redistribution
Subtotal
Duct loads
30%
54%
0
0
0
510
154
0
0
0
493
268
30%
54%
0
0
0
32
10
0
0
0
56
30
Total room load
Air required (dm)
664
27
761
33
42
2
86
4
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wY f9t�ttso� ' 2019-Mar-11 12:16:12
� --' Right -Suite® Uniwrsal 201818.0.31 RSU08101 Page t
E:\Documets\Wrightso8 HVAC\CRUL RESIDENCE.rup Onto = MJ9 Front Door faces: W
wrightsoft- Right-J(R) Worksheet Job:
Data: Mar 11, 2019
Entire House By:
QUICK CALCS, INC.
317 STLUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46&6799 Fax 772-466-6796 Emit: OUICKCALCS@AOL.COM
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
HERS
9.0 ft
9.3 ft heat/cool
7.0 x 9.0 ft
63.0 W
MASTER SUITE
36.0 ft
12.0 ft heet/cool
1.0 x 327.0 ft
327.0 ft-
Ty
Construction
number
U-vetue
(BtutVftL-F)
Or
HTM
(Btulvft'
Area (ft5
or perimeter (ft)
Load
(Btuh)
Area (ft0
or perimeter (ft)
Load
(Btuh)
Heat
Cad
Gross
N/P/S
Heat
Cod
Gross
WP/S
Heat
Cool
6
' '
_
13A-0acs �-
2glazing clr lotic
2 glaze clr loav-e
gluing,
2 glaz rg.,clr,bwe-�,
2gluirg, clr Iowa
2gluins
2 gluing, Gr lav-e
0:143
0.650
0.650
_O.650
0.650
1,610
n
n
n
_n_
a
a
e.
4 00
_ 1820
18 20
-18.20
8.20
18,20
20
-2.19
14.99
14.99
11.87
219
3208
3242
0
0
- 0
_,..._0
0
0
0
` 0
0
' 0
--0
0
0
0
, - 0
0
0
0
0
0
,0
0
- 0
_„-0
0
0
0
0
0__
0
36
0
_r' 0
0
0
.0
_ 36
0
'� 0
0
0
0
144
0
' 0
0
' 0
_ . _ -0
79
0
..
1p!
I�-1Gi
_VVpp11,
3P,-0ocs
2 glazing,clr laws
2 glazing, clr love
11GO
13A4ocs
2 glazing, dr Iowa
2 glazing, Grlowe
2 glazing, clr lave
i1D0
22A-Iph_-_
0:143
0.650
�-6-M
0.650
0.540
0.
0.650650
0.850
0.650
___ ,0.390
......_0.032
1.358
s
s
s
...s_
w
w
w
w
_ W,...
y..:
-
418
4 W
18.21)
18 20
-15..12
4.00
18.20
18.20
18.20
10.92
_..;0.90
38.02
219
14.99
14.99
-L14.31
2.19
3208
3265
22.28
,-10.34
'._.. v1.60
0100
0
0
0
_0
84
0
0
0
_ _..__-O._.0
S_ _-63
83
0
0
0
-0
84
0
0
0
__ __ .63
9342_
0
0
0
33
0
0
0
0
_ _e__0
_ - _ 56
0
0
0
18
0
0
0
0
0
- _ .101
- 0
192
0
30
204
0
0
0
_0
. -::_ 327
327
162'-"-
0
. 3o
204
0
0
0
-... -._. 0
.-__,'_327.
36
649
0
546
81
0
0
0
0
0
_ 293
1369
954
0
4 D
44
0
0
0
0
0
.. .. 523
0
,F A
6
c)AED incursion
-9
-75
Envelope loss/gain
734
275
3817
1777
12
a) Infiftration
b) Room ventilation
159
0
43
0
819
0
219
0
13
Internal galas: Occupants @ 230
Appliancesrdher
0
0
0
0
0
700
Subtotal nines 6 to 13)
892
318
4636
2697
14
15
Less eademal load
Less transfer
Redsbibdion
Subtotal
Dud loads
306
54%
0
0
0
892
269
0
0
0
318
172
30%
54%
0
0
647
6284
1594
6
0
424
3121
1693
Total room load
Air required (dm)
1162
47
490
21
6877
280
4814
209
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
-fk- 2019-Mar-11 12:16:12
A Right -Suite® Universal 2018 18.0.31 RSU08101 Page 3
EM)ocunnets\Wrightsoft HVAC\CRUZ RESIDENCE.mp Calc=We Front Door faces: W
wrightsoft Right-J® Worksheet Job:
Entire House Date: Mar 11,2019
By:
QUICK CALCS, INC.
317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Emall: OUICKCALCS@40L.COM
1
2
3
4
5
Roan name
Eposed wall
Room height
Room dimensions
Roomarea
DINING
15.0 ft
12.0 It heat/cool
1.0 x 196.0 ft
196.0 ft'
LIVING ROOM
13.0 It
12.0 It heat/cool
1.0 x 281.0 ft
281.0 ft'
Ty
Cowlmctim
number
U-value
(BtuWRi'F)
Or
HTM
(Btuvw)
Area (ft')
or perimeter (ft)
Load
(Btuh)
Arse (ft')
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cod
Gross
WP/S
Heat
Cool
8
11_
0143
- -�0650
O 650
0.650
0.143
0.650
_ _0.650
0143
0.650
,0 650
-._0.540_s_.__1512.
0.650
0.650
0.650
0.650
_ 0.390
1.358
n
n
n
n
a
a
_ e
s
s
a
w
w
w
w
_ w_
.--
_
400
-_ 1820
'18 20
18.26
--.18.20
4.00
18.20
_ 18.20
4.00
18.20
18.20
4.00
18.20
18.20
16.20
10.92
-.,0.90
_ 38.02
2.19
-1499
14.99
14.99
11.87_
219
32.08
_ 32,42
2,19
14.99
14.99
.14.31
2.19
32.65
32.65
22.28
_ 10.34
_-- 1.60
o00
156
0
-- 0-
64
._ b
0
0
0
- 0
0
0
0
0
0
0
0
_ 0
__ ., 281
_ 281
-92
0
0
0
,.
0
0
_ 0
0
0
0
,. 0
0
0
0
0
_ ._ 0
._-._.-281
13
^` 368
0
_, 0
1165
- 0
0
0
0
0
0
0
. 0
0
0
0
0
0
_._ , 252
494
-201
0
_ _ 0
959
_0
0
0
0
0
0
0
0
0
0
0
0
_ 0
_, . _450
___ _0
1344ocs
2glazirg clrlov-e
2 glazi g, clr lave
2 glazing, clr lairs
291azig, di,lov-e., _,___0.650.-n_
13A4ccs
2 glazing, Ur lc H e
2 glazing, clr love
13A-0acs
2 gluing, dr lox-e
2 gluing,.dr love
13A-0as
gluing,
2 nazi Urlav-e
2 gluing, Ur lore or lowe
g
11D0 - __ _
r16B-30aC'__� Y. ___...w..._-0.032
22A-lph__
0
0-
0
0
,, 0-._.
0
0
0
144
0
30
._ -_.0
36
0
0
0
__._-.-0
_ _ _:196
196
0
0
` 0
0
0,
0
0
0
_ 114
0
30
_ _.0
36
0
0
0
�_..- 0
.__ _ ,_i96
15
0
0
-'„ 0
0
_. .0
0
0
_ 0
456
0
546
... 0
140
0
0
0
____-.__0
_ .__- 176
5/0
-0
0
-- -0
0
.,_ '0
0
0
0
249
0
' 450
_ 0
79
0
0
0
-... __ a
�_ - 314
_ _ _0
_
IN
IL--CG
..11G0..-_
..�-
F,
-_.
..__.
6
c)PED excursion
-32
-78
Fmelope Iws/gain
1893
1059
2279
1532
12
a) Infiltration
b) Rcorr .erdilation
341
0
91
0
296
0
79
0
13
Internal gains: Occupants @ 230
Appliances(other
0
0
0
0
1
0
1200
Subtotal (lines 6 to 13)
2234
1151
2675
2811
14
15
Less edemal lead
Less transfer
Redisldlxdion
Subtotal
Duct loads
30%
54%
0
0
660
2894
873
0
0
447
1597
866
30%
54%
0
0
485
3060
923
0
0
318
3129
1698
Total room Iwtl
Air required(cfm)
3767
153
2454
1071
3984
162
4827
209
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
_ -+}r wrl9ht=+ofe- 2019-Mar-it 12:16:12
Right -Suite® Universal 2018 16.0.31 RSU08101 Page 4
AE:IDocumnels\Wnghlsod WAC%CRLIZ RESIDENCE.wp Colo =MJ8 Front Door faces: W
FkF wrightsoft' Right-.1® Worksheet Job:
Entire House Date: Mar 11, 2019
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77246"799 pas 7724668796 Email: DUICKCALCS@AOL.COM
1
2
3
4
5
Room name
E posed wall
Ram height
Ram dimensions
Room area
WCHEN
0 ft
12.0 ft heallcool
120 x 19.0 It
228.0 It'
FAMILYROOM
25.0 If
120 ft hest/ccol
14.0 x 11.0 A
154.0 ft2
Ty
Censbudion
number
U-value
(BtutVII-F)
Or
HTM
(Btulyft�
Area (ft')
or perimeter (ft)
Load
(Btuh)
Area (ft�
or perimeter (0)
Load
(Btuh)
Heat
Cod
Gross
N/P/S
Heat
Coot
Gross
WP/S
Heat
Cal
6
11
U11
----G
13AA6c --
2 glazing plr lower
2 glazing clr lotia
'2 glazing clr im-e
2glazing, G[Iov-e
134-0ocs
2 glazing, cU Ia
_2 giazirg, clr low-e
13A-4ccs _
2 glazi g, dr lc y
,2 glazirg, dr lowe
11G0
-13A
- -0 143
_- 0 650
.0 6W
0.650
..._. 0650
0.143
0.650
0_650
n
n
n
n
--n.
a
a
a
4.00
, '18.20
18.20
18.0
-18.20_
4.00
18.20
-. 18.20
_400
219
14.99
-14.99
14.99
11.87
219
32.08
_�.3242
.-219
14.99
14.99
._14.31
219
32-08
3265
22.28
10.34
,._.�1.60
0.00
0
0
- .0--
0
__ 0
0
0
0
--.._.0
0
0
_
0
0
0
0
0
�„-,_228
228
0
0
0
0
. _ 0...
0
0
0
.0
0
0
-0
0
0
0
0
0
�228
0,__
0
0
0
-- 0-
0
0
0
0
--__. 0
0
0
_.....�... 0
0
0
0
0
0
0
0
-- 0
0
_ _ 0
0
0
0
�.-.-0
0
0
_ -___0
0
0
0
0
0
168
0
- - 24
0
-0:_
0
0
0
0.
0
0
_ _�_; 0
132
0
24
0
0
__ ��154
154
144
0
__ ' , 0
0
0
0
0
0
-_-6
0
0
___._-0
108
0
1
0
0
�._. M
25
577
0
; _ 4.37
0
. 0
0
0
0
o
0
0
_- -'-.0
432
0
437
0
_ 0
,._-_ 13-8
_e 951
, 315
0
_ _ 35.0
0
.0
0
0
- _ _ 0
_ 0
0
0
... ., _ 0
236
0
784
0
0
.__--_:248
0
(L--GG
�fl
IL--GG
W
.C_'
F
0143
..0 650
0.650
�.D.540
- s
s
s
_s_
18.20
18.20
-1512
4.00
18.20
18.20
18.20
10.92
_,...'0.-90
38.02
flocs
2 glazing, clr lave
2 glazing, dr Iow-e
2 glazing, dr low-e
11Do
16B30ad�
22A-tph �
0.143
0.650
0.650
0.650
0,390
.�-_oM2.=.
^,�1.358
w
w
w
w
w
-
_e204
0
__-365
_0
6
c)AED mursion
-86
240
Envelope Ices/gain
204
279
2971
2181
12
a) Infiltration
b) Ram ventilation
0
0
0
0
569
0
152
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
2800
0
0
0
Subtotal pines 6 to 13)
2D4
3079
3140
2334
14
15
Less eldemal load
Less transfer
Redistribution
Subtotal
Duct lads
30%
54%
0
0
19
224
67
0
0
34
3113
1688
30%
54%
0
0
0
3540
1068
0
0
0
2334
1266
Total room load
Air required(cfm)
291
12
4801
208
4608
188
3599
156
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wro9htsoPe- 2019-Mar-11 12:16:12
A Right-Sulle® Universal 2018 1f1.0.31 RSW8101 Page 5
EADaurmelslWdghlsaft HUAC1CRUL RESI DENCE.mp Cale -MJ8 Front Door faces: W
r{i wrightsoft• Right-J@ Worksheet Job:
Entire House Date: Mar 11, zols
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: OUICKCALCS@AOL.COM
1
2
3
4
5
Room name
Eltoosed wall
Room height
Room dimensions
Room area
AHU CLST
0 ft
9.3 It heai/cod
4.0 x 4.0 It
16.0 ft'
UTILTY
0 fl
9.3 ft heat/cool
1.0 x 720 It
720 It'
Ty
Constnwtim
number
U-value
(BtutVft;°F)
Or
HTM
(Btuwft5
Area (ft=
or perimeter (it)
Load
(Btuh)
Area (ft=
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
•
ljY
134-0ocs - -
2 glazing, clr low-e
29lazng.-Gr by-e
2 glazing, Gr loq-e
2 glazing,-clnlo e-
13A4=
2glazing, Ur Iw
2glazirg, clrlave
0,143
0.650
_; 0650
0850
-0.650
n
n
n
n
_n-
-400
18 20
-1820
1820
__18.20
279
14.99
-14.99
14.990
.__1L87
_- .. 0
0
_._ 0..
0
. _ .__0
0
0
0
___
.0
0
_ _0.
- 0
_.___. �_0
0
0
0
_ --a
- 0`-`--0
0
-=.= 0-
0
0
0
0'
0
._ U
0
. -; 0
0
-0
'_0
0
,. -0
T 0
--C
_0
0
- _0.
-.. 0
_._.-.-0:...-0
0
0
10
0.-.-..
0.143
0.650
0650
-6-1-4-3143
a
a
a
4.00
18.20
1820
219
3208
3242
-218
0
0
0
0
0
0
0
0
_ 0
0
0
0
0
0
_ 0
0
0
0
----0
-
F
13A-0acs
2 glazing clr lave
2 gluing..Gr ldx-e
JlG0__...--..._-_._._. '
2 gluons
2 glazing, clr Io
2 glazing, clrlav-e
2 glazing, clr lowe
11D0_-�
...._
27Paph __
0.650
0650
-0.540
0.650
0.650
0.650
0.650
_-,�0.390
.�.....0.032
1.358
s-
s
a�
_s_
w
w
w
w
w
._ _
_.._
=
4 0
t 118.20
1820
'15.12
8.20
18.20
18.20
18.20
--._ 10.92
„.-_ 0:90
_ _38.02
14.99
14.99
:,-14.31
219
3ZO8
326585
22-28
10.34
___
,.,.�1.60
- _ _0.00
0:^
- 0
0
__ .._- o
0
0
0
0
_ 0
_ :'� 16
. _ . 16
-0
0.
0
, - ____.I0
0
0
0
0
._..,_ -,_._ 0
� ., � 16
0
0
0
0
--____0
0
0
0
0
.._ 0
-.- -,.14
0
0
0
10
.. -0
0
0
0
0
_ _ _ 0
. 28
0
0
0
- 0
_ _. 0
0
0
0
0
0
-_ .-72
72
0
0.
..' _ __0
0
0
0
0
0
- 72
0
0
- 0
---- --- 0
0
0
0
0
0
65
0
0
0'
0
_ -0
0
0
0
0
0
- 115
0
6
c)AED emursim
_1
.22
Envelope loss/gain
14
25
65
93
12
a) Infiltration
b) Room ventilation
0
0
0
0
0
0
0
0
13
Internal gains: Occupants @ 230
App(ianceslother
0
0
0
0
0
700
Subtotal pines 6 to 13)
14
25
65
793
14
15
Less a denial load
Less transfer
RedstfiWtim
Subtotal
Dud loads
30%
54%
0
0
-14
0
0
0
0
-25
0
0
30%
54%
0
0
13
77
23
0
0
22
815
442
Total room load
Air required(dm)
0
0
0
0
104
4
1254
5
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
- Ar w,rl9litsoft- 2019-Mer-1112:16:12
Ask-- - Right -Suite® universal 201818.0.31 RSU08101 Page
E:1DocwmetslWrightsoft HVAC\CRUZ RESIDENCE.rup Cole = MJ8 Front Door faces: W
wrightsoft' Right-J® Worksheet Job:
Entire House Date: Mar 11,2019
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
HALL 2
0 it
9.3 it beat/coot
4.0 x 11.0 fl
44.0 It'
BEDROOM 2
12.0 it
9.3 it healfcod
1.0 x 164.0 it
164.0 ft'
Ty
Construction
number
U-value
(Btuh/ft-F)
Or
HTM
(BtulJft")
Area III
or perimeter (ft)
Lead
(Btuh)
Area III
or perimeter (it)
two
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
11
-"
13A-0ocs`ry
glazing drloae
2 g ng'elrbwFe
2 glazing clr l
2 glazing„ drlo.4:e_
134-0ocs
2 glazing, Gr lax-e
2 glazing, dr lox-e
T3A4ecs
2 glazing, clr love
2 glazing, dr lc+ a
11130
2 glazing, dr lcw a
2 gluing,
2 glazing, dr laves
2 glazing, dr Icw-e
11D0_
16BJ�d„._..___._._.
-0143
0650
.--D650
D 650
"D.650
0.143
0.650
0650
0143
0.650
0.650
-0.540
0.650
0.650
0.650
0.650
0.390_w
._.___0.032
n.
n
n
n
_n_
a
a
a
s
s
s
_s_
w
w
w
w
-�._-0.90
-____38.02,
--400
1820
1820
18 20
Y 18.20
4.00
18.20
1820
4 00
1820'
18.21)
1512
8.20
18.20
18.20
18.20
_10.92
"219
14.99
7, 14.99
14.99
.._.11,87
219
32.08
32-42
219
14:99
14.99
-14.31
219
3265
3265
22.25
10.34
_-1.60
010D
0r.
0
'0
0.
0
0
0
0
0
0
0
--0--0
0
0
0
0
0
___44
_ 44
0
0
- 0oxes18.20
0
0
0
0
0
0
0�
0
0
0
0
0
0
_.._-44
- 0
_0
0
0
0
0
0
0
0
. 0
0
0
--0
0
-, e0
0
.,_.. _.D
0
0
0
- 0
0
0
0
0
-_0.
0
_..,..._0
112
0
15
" 0
0
0
0
0
Ol__.
0
0
97
0
1
-- - 0
0
0'
_.- 0
0
0
0
.0
387
0
273
-- 0
0.
0
0
0
__.. __0.
0
. 0
211
0
486
-- 0
0
0
0
0
0
0
0
0
262
0
1N
IL-�Gi
�tl
�-G
1=-G
���-----DDD
...____0
0
0
0
0
0
...... .39
_ 0
._.r.-_0
0
0
0
0
0
,-_- _ 70
0
---0
0
0
0
0
0
,.164
164
--_0.
0
0
0
0
0
_ 164_
12
_,.,..,0
0
0
0
0
0
147
456
6
c)AED excursion
-2
-33
Envelops loss/gain
39
68
1263
927
12
a) Infiltration
b) Room\entilenn
0
0
0
D
212
0
57
0
13
Internal gains: Occupants @ 230
Appliancestother
0
0
0
0
0
500
Subtotal (tines 6 to 13)
139
68
1475
1484
14
15
Less edema[ load
Less transfer
Redistribution
Subtotal
Duct loads
30°h
54%
0
0
-39
0
0
0
0
-68
0
0
30%
54%
0
0
115
1590
480
0
0
50
1533
832
Total room load
Air required (ofm)
0
0
0
0
2069
84
2365
112
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
- wr19�+4'soP[- 2019-Mar-ll 12:16:12
�A Right -Suite® Unhersal 2018 18.0.31 RSU08101 Page 7
r:\Dwumets\WNghtsoftWAC\CRLIZRESIDENCE.mp Calc=MJB From Doorfaces: W
wrightsof , Right-J® Worksheet Job:
Entire House Date: Mar 11, 2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772<86-6799 Fax 772AB"796 Email: OUICKCALCS@AOL.COM
1
2
3
4
5
Room name
E17used wall
Room height
Room dimensions
Room area
CLST 2
20 It
9.3 It healfcool
9.0 x 20 It
18.0 it-
BATH 2
6.0 It
9.3 it heat(cool
13.0 x 6.0 It
78.0 ft.
Ty
nonstmdon
U-value
(BtuNft'-°F)
Of
HTM
(Btwft�
Area (ft�
or perimeter (ft)
Load
(Btuh)
Area (ft5
or perimeter (fit)
Load
(Muh)
Heat
Cool
Gnus
NIP/S
I Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A-0ocs
2 glazing, dr low-e
29laz1ng,clrl0w-e
2 glazing, dr low-e
2 glazing„clr.bw�
13A-0ocs
2 glazing, dr Iow-e
2glazing,drImw
13AAms
2glazing clr low-e
2 glazing clr bw-e
11(30 -
13A-4ocs
2 glazing, clr lave
2 glazing, dr laws
2 glazing, dr 1a
11D0
-16B30'ad
22A-tph
0143
0.650
----0650
- 0.650
__.0 650
0.143
0.650
Y_0650
0 143
0650
0.650
-0.540
0.143
0.650
0.650
0.650
0,390
=0.032
1.358
n
n
n
n
n
a
a
a
`- 4.00
„ 18.20
�-1820
18.20
.:. 18.20
4.00
18.20
18.20
. -- 4 00
1820
18.20
=.15.12
4.00
18.20
18.20
16.20
10.92
38;02
"2.19
14.99
14.99
14:99
, . 11,87
219
32.08
_ 32.42
- 219
14.99
• 14.99
.__14.31
219
3208
32-65
22.28
10.34
- _-1',80
0.00
d
0
.0
0
- 0
19
0
0
_:0
-0
,0
_e-...___0
0
0
0
0
0
0
0
'. .r 0-
, 0
- D
19
0
_ 0_
_ - _.a
0
0
_,__a
0
0
0
0
0
0
0
-- 0
0
0
74
0
_ 0
_ 0
0
0
___„-,_0
0
0
0
0
0
_--.1„__,..2 6
76
0
0
__ __0
0
0
41
0
0
_. _..,,. 0
0
-0
0
0
0
0
0
0
_9
0
0
0
__ _M
0
0
56
8
0
. _ _ . -0
0
- '0
a0
0
0
0
0
0
=78
0
0
- _0:
0
0
48
1
0
_ _ ..0
0
0
-__,.e_..0
0
0
0
0
0
�._._.:78
6
0-
0
_. 0
0
0
191
146
0
_-. -. _ 0
0
0
__ _-.._.0
0
0
0
0
_ 0
�;70
228
0
0
_ 0
0
'0
105
257
0
0
0
0
_ _0
0
0
0
0
_ 0
�„ _ ,125
_ _ 0
_
_G
�pJ
T
s
s
s
_s„
w
w
w
w
w
-w-_..._0.90
��
�C
�D
1W _
_
,C_,,,-_
F
�_.18
18
=-18
2
78
6
c)AED Minim
-2
_12
Envelope loss/gain
167
67
635
474
12
a) 41fillration
b) Roomlentilation
35
0
9
0
106
0
28
0
13
Internal gains: Occupants @ 230
Applianceslother
0
0
0
0
0
0
Subtotal (tines 6 to 13)
202
77
741
502
14
15
Less e>aemal load
Less Uansfar
Red.t.bution
Subtotal
Dud loads
p
0
_202
0
0
0
0
_77
0
0
30%
54%
0
0
204
945
285
0
0
94
596
323
Totat mom load
Air required (cfm)
0
0
0
0
1230
50
920
40
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
2019-Mar-1112:16:12
.
Right -Suite® Universal 2018 18.0.31 RSL108101 Page 8
EADocurmelslWdghtsofl WAMCRLJL RESIDENCE.mp Calc-MJ8 Front Door faces: W
r{f wrightsofC Right -A) Worksheet Job:
Entire House Date: Mar 11, 2019
QUICK CALCS, INC. By:
317 STLUCIE LAPS, FORT PIERCE, FL 34946 Phone: 772466-8799 Fax 772-466-8796 Email: OUICKCALCSSAOL.COM
1
2
3
4
5
Room narne
E2posed wall
Room height
Room dimensions
Roomama
CLST 3
20 it
9.3 ft heat/cool
13.0 x 20 it
26.0 ft2
BEDROOM 3
12.0 ft
9.3 R heat/cool
1.0 x 1720 it
1720 ft2
Ty
Conshoction
number
U-value
(BtutJftL F)
Or
HTM
(Btulvft2)
Area (ft2)
or perimeter (f)
Load
(Btuh)
Area
or perimeter (it)
Lead
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
11
70
0
_ _0
0
._ -0
112
0
15
0
0
0
0
0
0
0
0
0
.-_-1i2:
_ 172.
0
T 0
�._0
� 0
... ..0
211
0
486
0
0
0
0
0
0
0
0
0
_. Zi5
_ _0
194ors
2 glazirlg,Ur Itwe
2 glaiing-cir ldve'
2 glmingiclr loti-e
2glazing.Gr.lox-e_
13A-4=
2 glazing, Gr low a
2 glazing, Gr lov-e
13440cs
2 gluing, clr lose
2glazng, Grlorv-e
11G0_-
2 glazing, Ur ltw-e
2 gluing,
2 glazing, or Iox-e
2 gluing, or low-e
11DO
22A-tph _
.0143
0650
--0 650
0 650
_0650.
0.143
0.650
_ 0.650
0 143
0.650
0650
-0.540
0.650
0,650
0.650
0.650
0390
1.358
n
n
n
n
n.
a
a
a
s
s '
s
_a-
w
w
w
w
vv
-
_. _
400
1820
-18 20
18.20
_ _18.20
4.00
18.20
18.20
4.00
. 18.20
1820
_.:-1512
8.20
18.20
18.20
18.20
_- 1092
_.. oso
._ 58.(12
f19
14.99
14.99
14.99
_11.87.-_
219
3208
_ 3242
219
14.99
14:99
14.31
219
3265
3265
2228
10.34
`� 1 0
. 0.00
0-
0
0
0"
.---0-.
19
0
0
0-
0
'0
_ _0
0
0
0
0
0
. '_,zs
_. _. _26
0
0
- - 0
0
_,0
19
0
0
0
0
_ '0
_ 0
0
0
0
0
0
. zs
_ _ _.._2
U
0
-, 0
0
._ .0
74
0
0
0
, 0
0
.. -0
0
0
0
0
0
_ _ 76
--:-0
0
0
'. - 0
o
41
0
0
0..
'' 0
o
0
0
0
0
0
0
. ._0
----0
0
_ 0
0-
..0
97
0
1
0
0
0
,. ;_0
0
0
0
0
0
_ =_172
_ . _ _ 12
-0
0
, 0
0
_ 0
387
0
273
0
0
0
_.0
0
0
0
0
`. _ 54
_456
_
V)J�
I�iG
_
1pll--li
�Ca
I-D
D
F
61
c)AED excursion
-2
-33
Envelope loss/gain
W4
80
1270
940
12
a) Infiltration
b) Room ventilation
35
0
9
0
212
0
57
0
13
Internal gains: Occupants @ 230
Appllances/other
0
0
0
0
0
Soo
Subtotal (fines 6 to 13)
209
89
1482
1496
14
15
Less external load
Less transfer
Redistribution
Subtotal
DW loads
30%
54%
0
0
-209
0
0
0
0
-89
0
0
30'/0
1 54%
0
0
125
1606
484
0
0
79
1576
855
Total room lead
Air required (crm)
0
0
0
0
2091
85
2430
105
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-Fk- wrlgFrrr�o"TPb- 2019-Mar-11 12:16:12
Right -Suite® Uniwrse1201818.0.31 RSW8101 Page
E:1DocumnelslWrightsafi WAC1CRUL RESIDENCE.mp Cale =MA Front Door faces: W
wrightsof , Right-JO Worksheet Job:
Entire House Date: Mar 11,2019
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM
1
2
3
4
5
Room name
Exposed well
Room height
Room dimensions
Room area
HALL
0 ft
9.3 h heat/cool
4.0 x 8.0 It
32.0 f'
BEDROOM 4
13.0 It
9.3 ft heat/cool
17.0 x 120 it
204.0 it'
Ty
Construction
number
U-blue
let
Or
HTM
(Stuh/115
Area (ft')
or perimeter (ft)
Load
etuh)
Area (ft')
or perimeter (B)
Load
(Btuh)
Heat
I Cod
Gross
N/P/S
Heat
Cool
Gross
N!P/S
Heat
Cool
6
it
_. -.
-
14J
13A-0ocs
n9 __
2glazlrg dr loN-e
2glazi cli,lox:�.u`Y0143
2 glazing, dr ION-e
g ng„
13A-0ms
2 glazing, dr Ia
2 glazing, dr taus
'�`
0 650
-- -0650
0.650
0.650
0.143
0.650
0 650
n
n
n
n
_n_
a
a
a
4.DD20
18 20
-='1820
18.20
�.18.20
4.00
18.20
18.20
V
14.99
4. 9
-14.99
14.99
__..11.87
219
32-08
32.42
-0'--
0
0'-�=
0
--0
0
0
0
0
0
0
0
_-__0
0
0
0
0
0
-_ 0
0
----0
0
0
0
•0
0
-;0
0
-.._._.,_0
0
0
0
0--
0
.-o-
0
__0
112
0
15
0
0
'.0
0
_ .._ __o
97
0
1
0
0
0
0
.. ,.. __0
387
0
273
_} 0
0
_ __0
0
. , _ 0
211
0
486
-l'
13A�4ccs -
2 glazing, cir Iowe
2 glazing, Gi kw
11G0
0 143
0.650,
0.650
s
s
.9
"5_
a og
18.20
18 20
-15.12
4.00
18.20
18.20
18.20
10.92
_ 0.90
38.02
_Z11s
14.99
14.99
_�14.31
219
32.08
3265
2228
___ 10.34
_ _ 1.60.
_ 0.00
o
0
0
0
0
0
--0
0
0
o
0
0
- 0
0
lo
. b
9
0
0
0
- -0
'_ _204-
204
_0
0
0
__--_0
9
0
0
0
__.. 0-
-. 204.
13
""'"` _0
0
0
,..._._.._0
37
0
0
0
0
__183
494
. _ 0
0
0
. x-__ __0
20
0
0
0
0
326
0
.
W
13A4acs
2 glazing, or Ion•
2 glazing, dr lc we
2 glazing, or lcx a
11D0--- .-__.�...
16B30ad____.__.:_ ,.a_._,0.032.;
-0.540.
0.143
0.650
0.650
0.650
_._0.390�W_
1.358.
w
w
w
w
-
-,.
4,__.0
0
0
0
0
_0-___.__0
.. .. 32
32
-0.-.0
0
0
0
0
:. ._ 32
0
0
0
0
0
_ _O_
.. _ _:29
.. _,0
--0
0
0
0
0
.- 0
_. ___ -51
0
C_�._,_.
171
6
c)AED ex:ureon
_1
_35
Envelope loss/gain
29
50
1374
1009
12
a) Infiltration
b) Room wrdilation
0
0
0
0
229
0
61
0
13
trriemal gains: Occupants @ 230
Appliances/other
0
0
0
0
0
500
Subtotal (three 6 to 13)
29
50
1603
1571
14
15
Less edental load
Less tmnl5fer
Redistribution
subtotal
Dud loads
30%
54%
0
0
.29
0
0
0
0
-50
0
0
3D/.
54%
0
0
5
1608
485
0
0
8
1579
856
Total room load
Air required(cfm)
0
0
0
0
1
2093
85
2435
106
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
2019-Mar-11 12:16:12
t�CA Right-Sulte4U Universal 2018 18.0.31 RBU08101 Page 10
E:1DmumtetslWdghtsoft HUAC%CRLRRESIDENCE.mp CWc=MJ8 Front Doorfxces: W
wrightsofC Right-J® Worksheet Job:
Entire House Date: Mar 11,z019
By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34940 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM
1
Room name
WIC 4
BATH 3
2
Exposedwall
15.0 ft
16.0 ft
3
Room height
9.3 ft heallcool
9.3 R heat1cod
4
5
Room dimensions
Room area
1.0 x 51.0 it
51.0 It'
9.0 x 7.0 ft
63.0 ft'
Ty
Construction
U-value
Or
HTM
Area qt')
Load
Area (ft�
Load
number
(Btuh/fti°F)
(Btuhlft')
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WPIS
Heat
Cod
Gross
N/P7S
Heat
Cool
6
lYY1��!!!-'
13A-0ocs "'
2 glazing, dr lox-e
0143
0.650
n
n
, `4 00
18.20
210
- 14:99
74
0
" 74
0
298
0
163
0
: 84
8
76
0
303
146
166
120
2glazing,-Grlav-e
--0650
n
-1820
14.99----
0-
0-
0
_-0
_ _0
_ 0
.0
0
_
11
2 glazing,`dlr 1b
2glazing,clr.Iwe„_.__._.--_0650,.n.
0.650
n
18.20
... 1820
14.99
_11.67__
0
0,
0
0-
'0
.. _ 0
, 0
_ -0
0
_ 0
0
.0._.
0
0.
0
�. 0
lfJ
LEI!-G.
1344ocs
2 glazing, dr to ns
2 gluing, clr love
13A-0acs
2 glazing, dr low-e
0.143
0.650
0650
0 143
0.650
a
a
e
S_
s
4.00
18.20
20 _ 18
4 00
1820
2.19
32.08
3242
219
14.99
65
0
0
_ _ p
0
65
0
0
_._.. __0
0
261
0
0
---0
0
0
142
0
0
...-.._0
00
0
0
0
. 0
0
0
0
_ O
0
0
0
0
____ 0
0
0
0
0
...0
0
I-�
2glazing, clr lox-e
11G0
0650
-0.540_
s
.._s
1820
_15-12
14.99
�14.31
0
'- 0
0
_- _0
-
0
-__._0
0
___._0
` w.0
_ _,.,.0
0
__-____0
0
-_ -0
0
_ ._ -0
W
0
13A-4=
0.143
w
4.00
2-19
0
0
0
65
45
181
99
2 glazing, dr lode
2 glazing, dr Io
0.650
0.650
w
w
18.20
18.20
3208
32-65
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2 glazing, clr lcx e
17D0._
.22A-t d'
0.650
0.390
,,.,_1.358
w
�w_
_,�
18.20
,. 10.92
-0.90
2228
10.34
= 1.80
0
0
0
0
,,.,.,_51
0
0
48
0
�-0
_�82
0
_..,. 20
__._._ 83
0
�..,,. ,-20
�,_.__69
0
218
.___. __56
0
207
. _. _101
,-
,0,.�_
T-51
F
22A-tph
_7.358
_,�
38.02
0.00
51
15
570
-�_ 0
_ 63
16
_608
, 0
6
c)AED eaursion
-12
-21
Emelope lWalgain
1175
374
1513
671
12
a) Infiltration
264
71
282
76
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
1
0
0
0
Appliancesiother
0
0
Subtotal (lines 6 to 13)
1439
445
1795
746
Less e+dernal load
0
0
0
0
Less transfer
0
0
0
0
Redistntxltion
0
0
0
0
14
Subtotal
1439
445
1795
746
15
Dud loads
30%
54%
434
242
30%
59%
541
405
Total room load
1873
687
2395
1151
Air required(cfm)
76
30
95
50
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrr9r+tsoft- 2019-Mar-11 12:16:12
. A "^ Right -Suite® U1lversal 201818.0.31 RSW8101 Page 11
E:\DwuonalslWdghtsoft HVAC%CRLrZ RESIDENCE.mp Cale = WS Front Door faces: W
+ wrightsofr Right-J® Worksheet Job:
Entire House Date: Mar11,2019
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: gUICKCALCS@AOL.COM
1
Roan name
FOYER
2
Eiposed wall
9.0 ft
3
Room height
12.0 ft heat/ccol
4
Room dirtrensions
9.0 x 120 ft
5
Room area
108.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ftj
Load
Area
Load
number
(BtulVft? °F)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
0143
n
400
2.19
0�
0
- 0
- 0
-
--
-
2glazing. elf lcva
'0650
n
1820
14.99
0'`
0
0
,0
-
IS
2glazing Urlwi-e
0650
n
_7820
14:99
0
0
0
10-
2 glazing clr 10
0 850
n
-. 1d20
14:99
0
_
— 0
-- 0
- "0
11
-2 glazing, clClo _.
_„0650
n
_',1820
.. ^11.B7
0
.- -..0
0
''0
lRJ
13AAws
0.143
a
4.00
2.19
0
0
0
0
2 glazing, clr lc v e
0.650
a
18.20
32.08
0
0
0
0
L�----GG
2 glazing, Ur Iow-e
0.650
a
18.20
32.42
0
0
0
0
13A-0ocs
'^0143
s
1- 400
219
1081
48
-- 192
` 105
2 glazing, elf lc N s
-0 650
s
18.20
14.99
12
12
218
180
2glazing elf lone
,, ,065o
s
,'182o
14.99
0
r 0
0
11G0-,„,,,,_,,._..,w.,�
.....�.0.540
s_
__;1512
,_._74.31
._.-,.,.......48
-.-....-_48
_._._�_726
_ —687
13A-4ccs
0.143
w
4.00
219
0
0
0
0
2 glazing, Ur lcw a
0.650
w
18.20
3208
0
0
0
0
2 glazing, Ur Iow-e
0.650
w
18,20
32.65
0
0
0
0
2 glazing, elf low-e
0.650
w
18.20
2228
0
0
0
0
11D0
0.390
_w
10.92
10.34
0
„_0
®.«.....�0
0-...—____
':i6B-30ad�,.„,.,.
=0032
_�'
= 0.90
:„„1;60
„_,-,�'108
'108.:,,..�..„.:87
'„„,.;...,s...173.�u,:-,__
_..._�.._
a ..................
.r..__...____.........._
.„_....M.:
,_,_,,.;,:._
F
22A-tph
1.358
_
38.02
0.0g
108
9
342
0
6
c)AED erousim
-33
Eneelope loss/gain
1575
1112
12
a) Infiltration
205
55
b) Roomtehtilation
0
0
13
Internal gains: Occupams @ 230
0
0
Applianceslother
0
Subtotal Vines 6 to 13)
1780
1167
Less external load
0
0
Less transfer
0
0
Redistribution
.1780
-1167
14
Subtotal
0
0
15
Duct loads
30%
54%
0
0
Total room load
0
0
Air required (cfm)
0
0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
A& r -FW wrlgr„tsoT- 2019-Mar-1112:16:12
Right -Suite® Unh,ersal 201818.0.31 RSU08101 Page 12
E90ocurrnets\Wrighlsoft HUACICRLrZ RESIDENCE.rup Code =MJ8 Front Door faces: W
wrightsoft° Duct System Summary
Entire House
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fac 772466-6796 Emit: OUICKCALCS@AOL.COM
Project Information
For. CRUZ RESIDENCE
5402 HICKORY DRIVE -LOT 2, FORT PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
1.00
in H2O
0
in H2O
1.00
in H2O
0.500 / 0.500
in H2O
1.000
in/100ft
1550
cfm
179
Job:
Date: Mar 11, 2019
By:
Cooling
1.00 in H2O
0 in H2O
1.00 in H2O
0.500 / 0.500 in H2O
1.000 in/100ft
1550 cfm
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
pn)
Duct
Mail
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH2
h 1230
50
40
1.000
5.0
Ox0
VIFx
23.4
115.0
st1
BATH3
h 2336
95
50
1.000
6.0
Ox0
VIFx
38.1
135.0
st4
BEDROOM
c 2365
84
102
1.000
7.0
Ox0
VIFx
10.1
115.0
st2
BEDROOM
c 2430
85
105
1.000
7.0
Ox0
VIFx
20.5
115.0
st1
BEDROOM
C 2435
85
106
1.000
7.0
Ox0
VIFx
35.1
135.0
st4
DINING
h 3767
153
107
1.000
7.0
Ox0
VIFx
5.2
115.0
st2
FAMILY ROOM
h 4608
188
156
1.000
8.0
Ox0
VIFx
37.3
135.0
st4
HERS
h 1162
47
21
1.000
5.0
Ox0
VIFx
34.3
115.0
st3
Hs
c 86
2
4
1.000
4.0
Ox0
VIFx
40.4
135.0
st5
KITCHEN
C 2401
6
104
1.000
7.0
Ox0
VIFx
22.6
115.0
st1
KITCHEN -A
c ' 2401
6
104
1.000
7.0
0x0
VIFx
22.6
115.0
st1
LIVING ROOM
c 2413
81
105
1.000
7.0
OxO
VIFx
32.2
115.0
st3
LIVING ROOM -A
c 2413
81
105
1.000
7.0
OxO
VIFx
41.2
135.0
st5
M BATH
h 4898
199
116
1.000
7.0
Ox 0
VIFx
43.1
135.0
sty
•TOILET
c 761
27
33
1.000
5.0
Ox0
VIFx
43.3
135.0
st5
MASTER SUITE
h 3439
140
104
1.000
7.0
Ox 0
VIFx
37.7
115.0
st3
MASTER SUITE -A
h 3439
140
104
1.000
7.0
OxO
VIFx
33.3
115.0
st3
UTLITr
c 1258
4
54
1.000
6.0
0x0
VIFx
7.1
115.0
st2
WIC
h 1873
76
30
1.000
5.0
0x0
VIFx
44.3
135.0
st4
ti +V vlrrig�Ftttsof[� 2019-Mar-11 12:16:14
ZU�e Right -Suite® Universal 2018 18.0.31 RS1108101 Page 1
KEADocurnnetslWrighlsoft HVACWRUL RESIDENCE.rup Calo=MJ8 Front Door faces: W
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st5
Peak AVF
309
258
1.000
700
9.0
0 x 0
VinIFIX
st3
st3
Peak AVF
717
592
1.000
913
12.0
0 x 0
VinIFIX
st4
Peak AVF
444
341
1.000
814
10.0
0 x 0
VinlFlx
st1
st1
Peak AVF
591
694
1.000
884
12.0
0 x 0
VinlFlx
st2
Peak AVF
242
264
1.000
597
9.0
0 x 0
VinlFlx
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1550
1550
0
1 0
0
0
ox 0
1
VIFx
wrightsaft- -- 2019-Mar-111276:14
.+ ••^^•• ^�•-+-+ Right -Suite® Universal 2018 18.0.31 RSU08101 page 2
AC'CA E1DocurmetstWrightsoft FWAC%CRUZ RESIDENCE.rup Calc=MJ8 Front Door faces: W
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.