HomeMy WebLinkAboutGENERATOR PAPERWORK16/20/22 kW
INCLUDES:
• True Power'" Electrical Technology
• Two Line LCD Multilingual Digital
Evolution"' Controller (English/Spanish/
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
• Electronic Governor
• System Status & Maintenance Interval LED
Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
GENERAC®
GUARDIAN° SERIES
SCANNED Residential Standby Generators
BY Air -Cooled Gas Engine
St. LucieCounty
• Direct -To -Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
• Capability to be installed within 18" (457 mm)
of a building*
FEATURES
Standby Power Rating
Models G007036-0, G007037-0 (Aluminum - Bisque) -16 kW 60 Hz
Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz
Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz
Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz
O INNOVATIVE ENGINE DESIGN 8 RIGOROUS TESTING are at the head of Generaes
success in providing the most reliable generators possible. Generac's G-Force engine
lineup otters added peace of mind and reliabilily for when you need it the most. The
G-Force series engines are purpose built and designed to handle the rigors of
extended run times in high temperatures and extreme operating conditions.
O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
form produce less than b%Total Harmonic Distortion for utility quality power. This allows
confident operation of sensifive electronic equipment and microchip based appliances,
such as variable speed HVAC systems.
O TEST CRITERIA:
J PROTOTYPE TESTED J NEMA MOI-22 EVALUATION
J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY
D�D�
Note: CUL certification only applies to unbundled units and units packaged with
pre -wined switches. Units packaged with the Siren Switch are UL certified in the
-Only if located away from doors, windows and fresh air intakes,
and unless otherwise drected by local codes.
O SOLIMATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state-of-the-art power maximizing regulation system is standard on
all Generic models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±t%.
O SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer
network provides pads and service know-how for the entire unit from the
engine to the smallest electronic component.
O GENERAC TRANSFER SWITCHES: Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
Lu GENERAC Q PROMISE
GENERAC°
16/20/22 kW features and benefits
Engine
•
GeneracG-Force design
MaAmbes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwallsand plasma moly rings helps the engine
ran cooler, reducing oil consumption resulting in longer engine life.
•
"Spiny-lok° cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•
Electronic Ignition/spark advance
These features combine to assure smooth, quick starting every time.
•
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur-
ing up to a 2 year/200 hour Oil change interval.. _
•
Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
•
High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
•
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulates the output voltage to±I% prevents damaging voltage spikes.
•
UL2200listed
For your safety.
Transfer Switch (it sipplicable)
•
Fully autanatic
Transfers your vital electrical loads to the energized source of power.
•
NEMA3R
Can be installed inside or outside for maximum flexibility.
•
Remote mounting
Mounts now your existing distribution panel for simple, low-cost installation.
Evolution" Controls
•
Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, ata-glance status indication in any condition.
•
Two-line LCD mul0lingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
•
Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpoints 65%dropout, 80%pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a
qualified dealer.
•
Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
•
Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•
Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every
other week. Also otters a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel
costs to the owner.
•
Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
•
Main line circuit breaker
Protects generator from overload.
•
Electronic governor
Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150
mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat-
ically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, attractive Makes for an easy, eye appealing installation, as close as 1a away from a building.
Installation System
• 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
• Direct-to-dirl composite mounting pad Complex lattice design prevents settling or sinking of the generator system.
0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life
16/20/22 kW
GENERAC
specifications
Generator
Model 13007035-0, G007036-0, 13007038-0, G007039.0 G007042.0, C997043-0
G007037-0 (16 M 120 k401 (22 kM
Type of Engine GENERAC G-Force 1000 Series GENERAC G-force 1000 Series GENERAC G-Force 1000 Series
cc
ivATM
"SaM louelsae WmIrm Ilehadol Ce gemala. Swd lemisbkm can o0¢ Wn of tieg� mryeeNga depmdeg an VMWAbnpvarem Ratingdbruin¢-Sbrdy.Appli.hlefaaryplytrgennganyPM la Ne d,,e,
aleuuti6lypmadage.Nowdo'adaptllyhavg.blefa@krAbg. VdabDgSinamx&¢eatin6S5514,150.9046aie RN6211). •fAeiannlmmmga�saManmdaosLletl NadlbNle6 pyycllgWyzyrygl HSynegalnde
cadet,anBieNlnryaaWo,aitihde.eg'oepamraMarditiwtelc A�eaenpmwtleaearsffia185perartlbearn 1.0001ee11SH4brrclas)aEmesealerel:adalm mllGeomeoa6oiAlpe�Ifaeadi8'C11 H'F)ffimIe 16C(60°F).
GENERAC`
111111111110
16/20/22 kW switch options
Limited Circuits Switch Features
• 16 circuits.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load,100% equipment rated, both inductive and
resistive.
2 pole, 250 VAG contactors.
• 30 millisecond hanster time.
• Dual coil design.
• Ratedfor both copper and aluminum conductors.
• Main contacts are silver plated or silver alley to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with I" standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive install.
Dimensions
200 Amps 120/240, to
Open Transition Service Rated
Height
width
H1
H2
w1
W2
Depth
in
27.24
30.0
11.4
13.5
7.09
mrs
692.0
762A
289.0
1 343.0
180.0
Note: The 50 amp switch is flush mountable. H1 and W1 refer to mounting hole spacing.
H2 and W2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover.
Wire Ranges
Conductorlug
Neutral Lug
Ground Lug
1/0-#14
210-#14
2/0-#14
Service Rated Smart Switch Features
!0 Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used in
Conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load,100% equipment rated, both inductive and resis-
tive.
• Up to four more large (120/240 VAC) loads can be managed when used in con-
junction with 50 amp Power Management Modules (PMM").
• 2 pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alley to resist welding and sticking.
• IVEMAJUL 311 aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 120240, 10
Open Transition Service hated
Height
Width
Hi
H2
W7
W2
Depth
in
27.24
30.0
11.4
1 13.5
7.09
mm
692.0
762.4
289.0
1 343.0
180.0
Model
G007036-0(16MR)
-et ales'
Current Rating (Amps)
1D0
Voitagk RatiQrAQi + . 12 4D16'i
,.,
Utility Voltage Monitor (Fixed)'
-hck- p
Bo%
-Dropout
65%
etUfn oU �:. 04f"Al,R
t•
Exerciser hi -weekly for 121dinutes•t 1 -
Standard
Total of Pre -wired Circuits
16
No. 15 A 120V
5
No. 20 A 120 V
5
No. 20 A 240 V
1
No. 30 A 240 V
No. 40 A 240 V
1
No. 50 A 240 V
1
Tanderd8reakca"Oabddtes i xr .;
Circuit Breaker Protected
Available RMS Symmetrical
10,0 W
Fault Current @ 250 Volts
*Function of Evolution Controller
Exercise can be set to weekly or monthly
Model 0907031.0 (16 kW)/0007039-0 (20 kW)/
G097043-0 (22 kW)
Current Rating (Amps)
2D0
Verisde Brrc�(VAG t ;
M-0o, to.
Utility Voltage Monitor (Fred)'
Eck up
80%
-0ropoul
65%
mWU41rh1.�:^u k a.,r.2�=eY e`ea5",
`.9DpmK to sec. ,p..
Exerciser weekly for 12 minutes'
Standard
r/t 4isted' Tc• *tie s"'i`-. x'i" ,? ,�-. �
_
Standard
Enclosure Type
NEMAJUL 3R
WOW 9ieak&Kiected "'''on,4115m
22AOU:-
Lug Range
250 MGM - #6
`Function of Evolution Controller
16/20/22 kW
GENERAC
available accessories
Modal
Product;' "Oesaiiption
0;b'
"a` ar'Ma, ilol
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac
G006463-4
Mobile Link'"
cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or
text message when a change in the generator's status occurs. Available in the U.S. only.
G005819-0
26R Wet Cell Battery
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PowerPactO).
G007101-0
Baftery Pad Warmer
The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below WE
(Not necessary for use with AGM -style batteries).
G007102-0
Oil Warmer
Oil warmer slips directly over the all fitter. Recommended for use if the temperature regularly falls below
0°F.
0007103-0
Breather Warmer
The breather wanner is for use in extreme cold weather applications. For use with Evolution controllers
only in climates where heavy icing occurs.
G005621-0
Auxiliary Transfer Switch
The auxiliary transfer switch contact Idt allows the transfer switch to lock out a single large electrical load
Contact Kit
you may not need. Not compatible with 50 amp pre -wired switches.
Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
G007027-0-Bisque
(Standard on 22 k"
sleek, contoured appearance as well as offering protection from rodents and insects by covering the fitting
holes located in the base.
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from
G005703-0 - Bisque
Paint Kit
future conusion. The paint Idt includes the necessary paint to properly maintain or touch-up a generator
enclosure.
GOOG485-0
Scheduled Maintenance Kit
Generac's scheduled maintenance Idts provide all the hardware necessary to perform complete routine
maintenance an a Generac automatic standby generator.
G006873-0
Smart Management Module
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
(50 Amps)
Power management capabgities. it provides additional powermanagemen[flexibility notfound in any other
power management system.
OimOrsiore sham areappmrrtala aelerto ms!allaim Huai foreW ffaam i. 00 NOT USEVESE
dimensions & PCs
Model
UPC
G007035-0
696471070354
G007036-0
696471070361
G007037-0
696471070378
G007038-0
696471070385
G007039-0
696471070392
G007042-0
696471070422
G007043-0
696471070439
GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
IIIIIIIIIIIIIIM 02015Genemc Power Sys .Inc.AAslgMr md.Mspectlicatlmsaresuhlealttclungewxhaenonce.Pan No.la000000194aoa'ia116
Automatic
Transfer Switches
Description
GENERAC®
Service and non -Service rated
Automatic Smart Transfer Switches
100 - 400 Amps, Single Phase
C @ us
LISTED
TUL only applies to non -service rated switches
General; Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'" or NeXUSTM
Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and
non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated
equipment configuration.
Standard Features
Service rated (RXSW) General; Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 311 enclosure', with
electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for
years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All
switches are covered by a 5 year limited warranty.
' Non -service rated (RXSC) switches are housed in a steel enclosure.
DPM Technology
Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC
controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be
managed as well, providing the most installation efficient power management options available.
;ISO
900C
2008
GENERAC°
100-400 Amps, Single Phase Automatic Smart Transfer Switches
Functions
All timing and sensing functions originate in the generator controller
Utilityvoltage drop-out......................................................................................................................................................................................................................<65%
Timer to generator start..................................................................................................
10 second factory set, adjustable between 2-1500 seconds by a qualified dealer"
Enginewarm up delay .......... ................ ......................................................
............................................................................................................................... -5 seconds
Standbyvoltage sensor.........................................................
--............................... -...... -............................................................................................ 65%for 5 seconds
Utilityvoltage pickup .............................................................
.............................................................................................. .............................................................. >80%
Re -transfer time delay...........................................................
................................................................................................................................................... 15 seconds
Enginecoal -down timer............................................................................................................................................................................................................60
seconds
Exerciser ...... .................................... ................................................................
_.................................................. 5 or 12 minutes adjustable weekly/Rf-weekly/Monlhly—
The transfer switch can be operated manually without power applied.
"When used in conjunction with units utilizing Evolution' controls "Adjustable via the controller
Specifications
Model
W(SC10OA3
RXSW100A3
RXSW15OA3
RXSC20OA3
RXSW200A3
RXSW300A3
RXSC400A3
RXSW400A3
Amps
100
100
150
200
200
300
400
400
Voltage
128/240, 10
120/240, to
120/240, io
120/240,10
120/240,10
120/240, 1e
120/240,10
120/240,10
Load Transition Type
(Automatic)
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Enclosure Type
NEMAAIL 3R
NEMAAIL 311
NEMNUL 311
NEMA/UL 311
NEWJUL 311
NEMA/UL 313
NEMNUL 311
NENIANL 3R
UL Rating
UL/CUL
UL
UL
UIJCUL
UL
UL
UL/CUL
UL
Withstand Rating
(Amps)
10,000
10,000
22.000
10,000
22,000
22,m0
22,000
22.000
Lug Range
1/0-#14
250 MGM-#6
600 MGM -#4 or 1/0-250 MGM
Dimensions
Model
RXSC10DA3
RXSW100A3
RXSWIKA3
8XSC200A3
RXSW200A3
RXSW300A3
RXSC4DDA3
r0(SW400A3
Height
111
1724/437.9
17.241437.9
26.75/679A
1724/437.9
26.751679.4
42.91/1089.9
31.25/793.8
4294/1089.9
(inlmm)
H2
20/508
20/508
30/762
2015D8
30/762
40/1219.2
36/914.4
48/1219.2
Width
W1
12.51317.5
12.5/317.5
10.51266.7
12.51317.5
10.51266.7
16.69/423.9
19.181487.2
16.69/423.9
(in.(mm)
W2
14.6/370.8
14.6/370.8
13.5)342.9
14.6/370.8
13.5/3429
21.82J554.2
24/609.6
21.BP/654.2
Depth (inlmm)
7.09/150.1
7.09/180.1
6.3/160.1
7.09/180.1
6.3/160.1
10.06255.5
10.06255.5
10M6/255.5
Weight(lbsJkilas)
20/9.07
22.5/10.21
39/17.69
20/9.07
39/17.69
140/63.5
133/60.33
140163.5
GENERAC" Genera; Power Systems, Inc. - S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
'�- Q2017 Gena4c Powu Systems, Inc. M dgNs mserve4. Ae 4pee4ica6ons xe si&IeMlo tlimge vn0mul natice. ButleN110000013459-A 04/24/17