HomeMy WebLinkAboutCERTIFICATE - DESIGN LOAD COMPLIANCE( EGG!" FP
rR nC
• pet StttL 9 e Cou E�an Buiilldi g t & Code Regulations Division & Development Services ment
2300 Virginia Avenue, Fort Pierce, FL 34982—(772) 462-1553
SCANNr
Certification for Design Load Compliance BY
Project Name: GERNER St. Lucie County
253 MARINA DRIVE
Permit
Type: Construction. Type:
• This certification must be completed, signed, and sealed by the design professional of record. qf/7 -p0"-'
• Submit (2) copies for residential, (3) copies for commercial with all permit applications
jONglySpg�ie (glJgvgjpg:
o New Residences (single or multi -family) REV IMi 6,1 PU
o Residential Addition CODE COMPLIANCE
o Any accessory structure requiring a building permit ST. LUCIE COUNTY
o Any non-residential structure. ^^t^+
* Note: Form not required for Interior renovations provided that no exterior structural el8QCQffected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as'(check one): _Enclosed _Partially Enclosed X Open
3. Risk Category:_) X II _III_IV Exposure Category:—B—C X D
4. Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 1 ft
S. Mean Roof Height 5'+/-DECK HEIGHTft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly labelonall plan openings):
Zone 1: Zone 2: Zone 3: Zone 4:+60.61-64.1 Zone 5+70.11-74.5 Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: 40 PSF Deck: PSF Stairs-.______PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9.
Is A Continuous Load Path Provided?
XYes
NotApplicable Explain Why Not:
10.
Design Soil Bearing Pressure:
PSF
Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
Drcesokl( cl. °=
DANIEL PAUL RETHERFORD 72451