Loading...
HomeMy WebLinkAboutPOOL PAPERWORKIU VUI .IIPICK Life Saver Pool Fence Systems, Inc. Removable Pool' Safety Mesb Barrier Fencing Tecbnical Specifications Life Saver Pool Fence Systems, Inc, has manufactured removable ool safety fencing for over 13 years and has continuously pevolved their methods and materials, often -time leading industry wide changes. A Manufacturers Limited Lifetime ev_e;y�systgm, iWarranty guarantes code requiremeorntsa,longas.they.ownt.Lifesaver,Poo1 Fencemeets aud•excae&all— - throughout Florida. Below you will find technical specifications onibe components used in assembling the Life Saver Pool -Fence. - TextileneMesh SCANNED BY St i_UCIe C00'0ty Textilene mesh has been used as the highest quality material to the pool fence industry for over 15 years. Laboratory testing shows its strengths to surpass all code specifications and applicable ASTM standards. Product Description_ Fabric using .025" dia. and fill. T70.DFS vinyl -coated 1000 den. polyester core yams in the walp G..onsiruction, t:n ' Inch D377Z-96 • 13.0 Weight; ozlyd2 b3776-96 ±.5 Tensile Strength (grab), Ibf D5034-95 221.4. Tensile Strength (strip), lbf D5035-95 194.9 Tear Streri th 9 > (Trapezodial), If ( D1117-97 65.4 Ball Bdrst, Ibf . D3787-89 Bursting Strength, psi D3786-89 Elongation, % • D5035-95 244.3 Abrasion Resistance D3884-92 (CS101500 cycleslwith no added weight) Flammability Raring Weatherability., 1200 hours G53-96 Mildew Resistance G21-96 The above results are a representative of real data from single test samples. Presently no specification is incorporated. 21'3.3 153.8 54.0 335 433 21.6 No expgsuze of core yam. GS-191-53 & CA 117E No discoloration No growth Warp refers to the horizontal threading while fill refers to the vertical threading. As shown, all testing confirms Texhlme mesh meets and, on all strength tests, amply exceeds the set code requirements. REVIEWED FOR CODE COMPLIANCE STs LUCIE COUNTY BOCC .. r LIFE SAVER POOL FENCE SYSTEM SPECIFICATIONS General Description: Pool fence designed specifically to provide a barrier around 'residential swimming poo]s for toddlers and young children. Life Saver Poo] Fence Systems ® does not have any — - _ gaP�sM-�*gs indentations,protrosions, or_sttucbral-components-that could -allow a _• Y ::•r.-^ .-v.... young child to crawl -under, squawe� thmughl-orrclimb.ovm-ghe•bamer Our exegffsiVe Perma Locking System will not allow the barrier to be removed without the aid of tools. Life Saver Pool fence is manufactured and installed in compliance with the Florida Building Code R4101 _I 7:I.1 1hrQU9b R4101.17,1.14 and the Florida Statute Sl Sig. System: Tension based system utilizing a series of 15 foot sections of fencewith inserts for mounting in non-conductingpolypropylene sleeves core drilled 4 inches -deepinto concrefe ._eek :or:other-sitbsfantialsnrface; connected in series at the top tvitb our ex-ciusive2 l/2 inch Perma Locldng System. Construction: Mesh: P@yeStCr3mcsh fahricyfilh amildewyegstautpolyVinyl coating to provide for years ofuse in direct sunlight Continuous basket weave with a tensile strength rating of 270 lbs. Per inch making it impossible to rip undernonmal use. Color selection is black; white or green. Available in 48 or 60 inch heights_ Bordered on all four sides by, a reinforced vinyl material with a rating of 387 lbs. To prevent sagging and provide the necessary tension to insure the fence's integrity for its intended purpose both at the top and bottom. The mesh is pre -mounted on aluminum support poles and secured by aluminum cove molding strips. Poles: Poles are constructed of marine grade aluminum, black, white or green powder coated or silver finish Pole spacing is at 36 inches. Stainless steel screws (14) are utilized for securely attaching the aluminum cove molding to the poles and mesh. ' Surface of the poles are finished for handling and to prevent injuries from physical contact - The poles are capped to provide ameat finished appearance. - Revised 030603 L j Lif esaver Pool i Fence POINT OF ATTACHMENT B POLY SLEEVE POINT OF ATTACHMENT Soroen or Wntl Nut itshit"d Parmo L L.... -...... _ ...— _ U. _. _. MM%;nM )' Abt t Brock RAVER DECK 1013 3HEET 2 OF GATE OPENING - �PrQ�sYrles SCANNED St. Luce C®urdv OWNER'S MANUAL ENGLISH I FRANGAIS I ESPAPAOL Jandy Pr® Series Nicheless LE® Underwater Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the productwill be installed where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance: so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product- Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation andtor operation will void the warranty. dh Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. ATTENTION INSTALLER - This manual contains important Information about the installation, operation and safe use of this 'w product. This information should be given to the owner/operator of this equipment U2 s ��CS1VF0 JUG 2 410 Pehrritti %9 St (u eD P eot fy Page 2 Nicheless Underwater LED Lights I Owner's Manual Table of Contents Contents Section 1. Important Safety Instructions ....... 3 Section 2. Installing the Jandy® Pro Series Nicheless LED Light......................4 2.1 Preparing the Light Fixture for Installation .....................6 2.2 Installing the Light Facture............................................6 Section 3. Wiring Options for Controlling Jandy Pro Series Nicheless LED Lights......................................7 3.1 Wiring to an AquatiW IRS Control System ..................7 3.2 Wire Gauge and Length................................................8 3.3 Wiring to a Switch..........................................................9 3.4 Twelve (12) Volt Installation...........................................9 Section 4. Jandy Pro Series Nicheless Underwater LED Light Operating Instructions..................................10 4.1 Light Synchronization..................................................10 4.2 Operating the Light........ ........................ ........ ...:.......... 11 Section 5. Designer Lens Series Options .... 12 Section 6. Light Cartridge Replacement ...... 13 Section 7. Winterizing....................................14 Section 8. Troubleshooting ..... :................. ....16 Wheless Underwater LED Lights i Owner s ManualdMEMMW Page 3 Section 1. Important Safety Instructions IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR -INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: DANGER RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This underwater light must be installed by a licensed or certified electrician in accordance with the National Electrical Code® and applicable local codes and ordinances. In Canada, the Canadian Electrical Code and all applicable local codes and ordinances must be adhered to. Improper installation will create an electrical hazard, which could result in death or serious injury, to pool or spa users, installers, or others due to electrical shock, and may also cause damage to property. Read and follow the specific instructions below. WARMING Before installing this underwater light, read and follow all warning notices and instructions accompanying this light. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Visit www.zodiacpoolsystems.com for additional free copies of these instructions or call Zodiac Technical Support at 800.822.7933 (U.S.) or 888,647.4004 (Canada) CAUTION Except when the Jandy® Pro Series Nicheless Underwater LED Lights are installed in an area of the swimming pool that is not used for swimming and the lens is adequately guarded to keep any person from contacting it, the light shall be installed in or on a wall of the pool, with the top of the lens opening not less than 4 inches (102 mm) below the normal water level of the pool. ATTENTION INSTALLER This manual contains important information about the installation, operation and safe use of this product. This information should be given to the ownerloperator of this equipment. SAVE THESE INSTRUCTIONS Page 4 LED Lights I Owner's Manual —A-WARNING - - - - RISK OF ELECTRICAL SHOCK OR ELECTROCUTION, which could result in serious injury or death. The Jandy® Pro Series Nicheless LED.Lights are only available for 12-voltAC power. For supply connection, use only an isolating low voltage power supply with ungrounded output, evaluated and listed by a NRTL for swimming pool use. Section 2. Installing the Jandy Pro Series Nicheless LEIS Light A WARNING Risk of Electrical Shock or Electrocution. This underwater light must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code® (Canadian Electrical Code, in Canada) and all applicable local codes and ordinances. Improper installation will create. an electrical hazard, which could result in death or serious injury to pool or spa users, installers or others due to electrical shock, and may also cause damage to property. Always disconnect the power to the light at the circuit breaker before installing or servicing the light. Failure to do so could result in death or serious injury to serviceman, pool or spa users or others due to electrical shock. Use the chart below to determine the appropriate pipe length for your installation. WATTS MINIMUM LENGTH FOR 1.5" PIPE JLU4C9W 9w 3" . . JLUW9W 9W 3" JLU4C20W 20W 9" JLUW20W 20W 9" JLU4C30W 30W 14" JLUW30W 30W 14" All products listed above come in a variety of cord lengths. Typical cord lengths are 50, 10o, & 150 Peet. NOTE: The lights are servicable - do not remove the enclosure or cord from the conduit. No seperate ground or bonding wire is required for the JLU4C9W, JLUW9W, JLU4C20W, JLUW20W, JLUW30W or JLU4C30W low voltage lights which do not have any exposed metal. Nicheless Underwater LED Lights I Owner's Manual Page 5 2.1 Preparing the Light Fixture for Installation NOTE: The electrician must complete preparatory steps before light fixture is installed. See Figure 1. Verify that the pool meets the requirements of the current National Electri- cal Code' (Canadian Electrical Code, in Canada) and all local codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the underwater light is installed. Some of the requirements of the National Electrical Code, which the pool electrical systems must meet, are as follows: 1. The junction box or the low -voltage transformer must be located at least'eight (8) inches (measured from the inside of the bottom of the junction box or transformer) above the MAXIMUM water level, OR at least four (4) inches above the ground level or pool deck, whichever is greater. The junction box or transformer must also be installed at least forty-eight (48) inches (4 ft.) from the edge of the pool. See Figure 1. 2. A standard 1.5" plastic wall / return fitting (not included) must be installed so that the top edge of the underwater light's lens is at least 4 inches (10.2 cm) below the surface of the water in the pool. See Figure 1. NOTE: To be certain that the pool's electrical system meets all applicable requirements, the electrician should also consult the local building department. 12 VAC Class 2 Transformer or lJunction Box 1 48' min. _— — i Chad,MJfar door}W. raq.nemeNs h I 1 s° minimum to maximum water level i 4' min to top of lensr RigitlRlgid Electricalbeam L 1.5, pipe through bond and a minimum length Cord, L Sweep elbowsLL for each style IighL only, no 90- elbows. (See Light Info Charts, p.4) NOTE Vanlcol Instanarwns Such as W¢ and walkout WCeYans will use ALL of the sameolearanoo raquubnah% Figure 1. Jandy" Pro Series LED L ght Installation with Standard 1.5" Plastic Fitting Page 6 Nicheless Underwater LED Lights I Owner's Manual 2.2 Installing the Light Fixture NOTE: Perform these steps only after the electrical system requirements are met. 1.5" pipe must be installed through the bond beam with a minimum length of l4", followed by I" conduit with sweeps only without 90 degree elbows. It is highly recomended to use 1.5" pipe throughout the entire width of the bond beam. NOTE: Gaskets help ensure that conduit is out a potential _ leak path. For vinyl wall fittingsIsl;- use both rubbergaskets. For'-----1� gunde and fibergtass remove 6�_,_,,aa.�.i`'` r:='"iC":.:1't.�"5 the small gasket and use the large one only. small Gask"t Flat Gastal See chart an page 4 for On. 4" MIN. FROM WATER length requirements I LEVELTOTOP OF LENS' I"mmimucn ( rigid conduit I.5" Pipe NoMdegwelbam �\1.5"THREADED WALL FITTING Figure 2. Standard installation with 1.5" pool wall fitting 2. Snake the 2-Conductor electric cord through the conduit outlet of the wall fitting, into the conduit and up to the location of the 12VAC pool transformer. Cut off cord after allowing for service and length of run to the transformer. 18"-24" of excess cord is recomended for the service loop. Pull the fixture snug to the wall fitting. NOTE: When using a 1 1/2" MIP fitting on the back of a SP-1022 or SP-1408 Wall Fitting, the interior of the Spears and Dura MIP are too small for use with the JandyO Pro Series Nicheless LED Lights. I Using the included Lens Key, thread the light into the wall fitting until it is snug. Please provide the pool owner with minimum of I key upon job completion. rlw� Nicheless Underwater LED Lights I Owners Manual Page 7 f2VAC Fool Traaslom+.er, see fable 321or nova delwls Aft0r—" VrNAC PeoI Tea�9mmm eaLWr &M. Loop NOTE som.. Loop not applicable forluncdon Boa WfaflatloL1 _ -- IEVF:L TC TCPCFLF.NS Co I W IWACvvnWmx UKS Installation for Figure 3. Standard installation with 1.5" pool.wgll fitting Section 3. Wiring Options for Controlling Jandy" Pro Series Nicheless LED Lights NOTE: Always consider.the cable length when calculating the input voltage at the transformer. The maximum run of service between transformer and lights should not exceed 150ft. in length, inclusive of the use of J Box. or not. To the extent allowed by local installation codes in effect in the installation jurisdiction and capacity of the electrical equipment, multiple Jandy Pro Series lights may be controlled with a single switch and transformer so their colors may be synchronized. IMPORTANT NOTE: All fixtures must be tied into the same transformer, circuit or switch for synchronization to occur. The use of Solid Core over Stranded wire and terminating Bus Bars is strongly recomended. 3.1 Wiring to an AquaLink-0 Controiier The Jandy Pro Series Nicheless LED Lights can be controlled by an AquaLink controller. Connect the transformer powering the lights to one of the auxiliary relays in the AquaLink. Refer to Figure 4 to connect the Jandy Pro Series Nicheless LED Lights to the Power Center. Page 8 qqmlmk 49,2111161 Nicheless Underwater LED Ughts I Owner's Manual 3.2 Wire G.uage and Length CAUTION Jandy® Pro Series Nicheless Underwater LED Lights are low voltage fixtures. Improper wire guage and wire length can effect the performance of these products. Follow the guidelines below to determine the proper operation and optimum performance of the lights. Voltages are determined by the measured voltage level at the Bus Bar where the transformer and cords are connected. NOTE: Each color mode has a slightly different power draw JLU4C9W/JLUW9W/JLU4C20W/JLUW20W MinlMax Voltage per cord length Cord Length Min. Voltage Max. Voltage 50 Feet 9AVAC 12.4VAC 100 Feet 10.7VAC 13.2VAC 150 Feet 11.82VAC 13.8VAC . JLU4C30W & JLUW30W MinlMax Voltage per cord length Cord Length Min. Voltage Max. Voltage 50 Feet 10.34VAC 12.56VAC 100 Feet 10.9VAC 13.5VAC 150 Feet 11.43VAG 14.1 VAG A WARNING RISK OF ELECTRICAL SHOCK OR ELECTROCUTION, which could result in serious injury or death. A Ground Fault Circuit Interrupter (GFCI) must be provided for 120 Volt transformers. The conductors on the load side of the GFCI circuit shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional conductors are also protected by a GFCI. Refer to local codes for complete details. ® WARNING RISK OF ELECTRICAL SHOCK OR ELECTROCUTION, which could result in serious injury or death. The Jandy Pro Series Nicheless LED Lights are only available for 12-volt AC power. For supply connection, use only an isolating low voltage power supply with ungrounded output, evaluated and listed by a NRTL for swimming pool use. Nichetess Underwater LED Lights I Owner's Manual Pat�W 9 3.3 Wiring to a Switch The Jandy`—Pro Series Nicheless ZED -lights can lie wired to a switch to manually operate the lights. Refer to Figure 4 to connect the lights into the switch. Automation Aux Relay or SWitch Y e U Ip >L ra } I� Line 0 Black Black Neutral White While 120 volts to GFCI 12VAC Ground Ground Green Transformer Figure 4, wiring Jandy Pro Series hlicheless Underwater Lights 3.4 Twelve (12) Volt Installation A 12-14 Volt AC Transformer must be used to power all 12-Volt lights. NOTE For optimum performance Jandy Pro Series recommends not exceeding the load factor specified by the instructions included with the transformer. To ensure maximum safety; use only a Class 2 transformer that can supply 12-14 Volts AC to power all 12-Volt lights. The transformer must be Listed or certified by a Nationally Recognized Testing Laboratory (NRTL) for the intended use. A CAUTION To prevent risk of fire which could result in property damage, and to ensure optimum performance, do not exceed the load factor specified in the instructions provided by the transformer manufacturer. Page 10 INE SWIM. Ndidess underwer LED ughts ► amens manual CtI 2itansrotmat —— J 15medwR Amomuioohh5: Ot6pui`f&tBV0.0 ero-mna.� ac it8 !1 1 y. £ rSWpI'W 631' Ii i_ � eOVe�B Figure 5. Wiring LED Lights to a 12 Volt Transformer NOTE A dimmer switch or dimming relay maybe used when Jandy Pro Series Nicheless WHITE ONLY lights are installed. Jandy Pro Series color lights are NOT DIMMABLE and are NOT COMPATIBLE with dimmer switches or dimmer relays. . Section 4. Jandy® Pro Series Nicheless Underwater LED Light Operating Instructions 4.1 Light Synchronization NOTE This section only applies to the color (RGBW) lights. All fixtures must be tied into the same transformer, circuit or switch for synchronization to. occur. 1. Turn the light ON. if the light has been off for 7 seconds or longer, the light will turn on at the last color selected. 2. To synchronize multiple lights to the same color mode, you Will need to reset to the beginning of the color mode sequence. With the lights ON, turn them OFF for five (5) seconds, then turn ON again. All of the lights will reset to the Alpine White color tnode. if all of the lights are not in the Alpine White color mode, they have not been synchronized, repeat step 2. Nicheless Underwater LED tights I Owner's Manual page 11 4.2 Operating the Light 3. To change the color mode, turn the light OFF for one 1-3 seconds. Continue hsrning OFF and ON until the desired light color mode is reached. See Table I —for the color mode sequence. Example: If you followed step 3 and are now on Sky Blue and want the lights to be Violet, then the lights must be turned off and on 7 seven times to bring you to Violet. Sequence Order Color Modes 1 Alpine White 2 Sky Blue 3 Cobalt Blue 4 Caribbean Blue 5 Spring Green 6 Emerald Green 7 Emerald Rose 8 Magenta 9 Violet 10 Slow Color Splash 11 Fast Color Splash 12 America the Beautiful 13 Fat Tuesday 14 Disco Tech Table 1. Color Mode Sequence 4. The lights have memory. If the lights are off for 7 seconds or more, the next time the lights are turned on, they will return to the last color mode they were on prior to being turned off (Step 1 listed above). This function allows you to keep your lights returning to your favorite color mode every time the lights are turned back on. NOTE To synchronize colors on multiple Jandy® Pro Series Nicheless Underwater LED Light systems wired to separate switches, perform the above actions on all of their switches simultaneously. All Jandy Pro Series Nicheless Underwater LED Lights will synchronize automatically if activated by the same switch. No other accessories are required, Page 92 Niche ess Undenrtater LED tights I Chmses Mamial Section 5. Designer Lens Options The Resigner Lenses offer a unique set of options for the LED Series of lights. Each one has the ability to create unique lighting effects within the pool's interior. See the list below to leant more about the designer lens options. HALF DOME - This escutcheon adds over the existing lens to allow you to direct t/2 the light in a direction you want. Downwards -to light a pools interior without light shining upwards. Upwards to light a water feature or sideways to put light where it might be needed but no where else HALO LENS - This lens allows for gentle lighting in an area but knocks down the center beam. This allows for installation on walls, etc. where there might be an opposite wall, etc. where you want to eliminate generating a "hot" spot. Great general lighting but softly. SPOT LENS - Just the opposite of the Halo. Concentrates the light and reduces the output at wider beam angles in order to produce a spot -light effect. Great for illuminating that special feature. CATS EYE - This lens reduces the light to just a "slice" of light that is broad but thin. An incredible effect for illuminating but without spilling light all over. DIAMOND - WOW want to really create something special? The Diamond lens creates incredible points of light throughout the interior. The points will be different the farther away from the light they are. Put the LED colored light on DISCO TECH MODE AND WATCH THE FUN BEGIN! Nicheless (Inderwater LED Lights I Owner's NtanuaL�MIMMJJVPage 13 Section 6, Light Cartridge Replacement RISK OF ELECTRICAL SHOCK OR ELECTROCUTION, which could result in serious injury or death. The Jandy° Pro Series Nicheless LED Lights are only available for 12-volt AC power. For supply connection, use only an isolating low voltage power supply with ungrounded output, evaluated and listed by a NRTL for swimming pool use. Always disconnect the power to the light at the circuit breaker before installing or servicing the light_ Failure to do so could result in death or serious injury to serviceman, pool or spa users or others due to electrical shock. 1. Verify that the light has been disconnected from the power source and be sure that the light fixture is in a dry environment. Remove the eight .(8) screws from the tens with the tool provided. Pull the lens front the fixture body. Remove and discard the 0-ring between the Lens and Fixture Body. 2. Using the tool provided, insert and turn the threaded portion into the extraction hole in the face of the light cartridge. Pull the light cartridge from the housing body. 3. Insert the replacement cartridge into the housing body. Line up the TAB at the end of the circuit board with the receiving slot inside the housing body. It may be necessary to slowly turn the light cartridge until the TAB lines up with the slot. Page 14 4RESEEM Nicheless Underwater LED Lights I Owner's Manual 4. Clean the tens and the enclosure of any remaining old silicone before applying new silicone and replacing the tens. Replace the O-ring with the new one provided. Attach the lens onto the fixture body. Tightly secure the eight (8) screws indicated in the diagram below. Once all screws are tight, slowly submerse in water, checking for any air bubbles - quickly remove from water bubbles appear as it indicates the seal is not water tight retighten the screws and test for bubbles again. SILICONE BEAD ON LENS SCREW TIGHTENING DIAGRAM Apply a new silicone bead to the lens with tube provided after cleaning the lens and body of old silicone. 5. Reset the fixture into the wall fitting and turn the power ON. Section 7. Winterizing The water level should be lowered to approximately 12 inches below the pool lights. Make certain that the water is drained out of the wall housing. Consult a Local Swimming Pool Professional for proper winterization. Minimum safeguard requires dropping the water level 2"-4" below the light At NO TIME should there be water removed from the pool without checking ground water tables. Nicheless Underwater LED Lights I Owner's Manual Section 8. Troubleshooting Page 15 Use the troubleshooting information in the following table for suggestions. .. -P,'rG'b,1,e11AX Cqrrective AdIon lArights fail to illuminate Lights are not reciev Check 120VAC power supply ing power into transformer. Check for - — - - -12VAC output -at -transformer. - Check or reset GFCI. Make r sure 120 volts has not been used in the installation - damage is assured and is NON One or more lights are Poor connection or _WARRANTY. Separate each light and dim, blinking or not improper wire gauge independently wire 12V to the working single light only. Repeat this process on each light. If junc- tion box is being used, check for proper connection of light cord. Verify that the correct wire guage is being used between the transformer and junction box. Colored lights out of Improper voltage Verify that proper wire connec- synch supply or poor con- tions are being achieved for nection to the light the lights that aie out of synch. Reset all the lights to white by turning lights OFF for five (5) seconds, then turning ON Jandy® Pro Series Nicheless Underwater LED Lights are field servicable and the cord and light.body fixture should not be removed completely from the conduit or pool. There should be enough cord supplied in the service loop to remove light from wall fitting and lifted above water level for LED light cartridge replacement. If there is not enough cord in service loop or it cannot be accessed, pool water can be drained below light to access front of light.