Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ROSS New House Project Builder Name: 7606 FORT WALTON AVE. Permit Office: SCANNED City, State, Zip: FORT PIERCE, FL, 34951- Permit Number. g Owner. MRS. PARICIA ROSS Y�a�p,,� Jurisdiction: 661100 �$' Design Location: FL, Fart Pierce �Uriiel.� Cnl/�fViV 1. New construction or existing New (From Plans) 9. Wall Types (980.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 980.00 ft' b. WA R= fP 3. Number of units, if multiple family 1 c. N/A R= iP 4. Number of Bedrooms 2 d. WA R= ft' 5. Is this a worst case? No 10. Ceiling Types (1200.0 sqft.) Insulation Area a. Roof Deck (Vented) R=0.0 1200.00 112 6. Conditioned floor area above grade (Tt') 1200 b. WA R= ft Conditioned floor area below grade (W) 0 c. N/A R= ft' 11. Ducts R ft' .7. Windows(54.7 sqR) Description Area a. Sup: Attic, Rat Main, AH: Main 6 232.2 a. U-Factor. Dbl, U=0.65 46.67 ft' SHGC: SHGC=0.27 b. U-Factor. Dbl, U=0.55 8.00 ft12. Cooling systems kBtumr Efficiency SHGC: SHGC=0.27 a. Central Unit 24.2 SEER:13.00 c. U-Factor. WA ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. WA ft' a. Electric Heat Pump 18.2 HSPF.7.80 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1200.0 sgft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1200.00 ft' b. Conservation features b. WA R= fN None c. WA R= ft' 15. Credits CF, Pallet Total Proposed Modified Loads: 18.99 Glass/Floor Area: 0.046 PASS Total Standard Reference Loads: 28.49 1 hereby certify that the plans and specifications covered by Review of the plans and qUE S7,9? this calculation are in compliance with the Florida Energy specifications covered by this y� ' 'e c SOS Code. calculation indicates compliance y �„ '' -E=i with the Florida Energy Code. ro � mnr:• "� -t:-- u O PREPARED BY: Before construction is completed .;.. DATE: o - t this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. ✓,i yt with the Florida Energy Code. COD WE OWNER/AGENT: V�SRo'kCka �Z ass BUILDING OFFICIAL: DATE: (P-a I- 15 1 t3 DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Heat sys #1 may be undersized. Size of 18.2 was increased to 18.2 for simulation. Please review the Manual J8 report- Cool sys #1 may be undersized. Size of 24.2 was Increased to 24.2 for simulation. Please review the Manual J8 report 3/15201311:22 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT rive: Building Type: Owner. # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: ROSS New House Project User MRS. PARICIA ROSS 1 661100 Single-family New (From Plans) Bedrooms: 2 Conditioned Area: 1200 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 7606 FORT WALTON St. Lucie FORT PIERCE, FL, 34951- CLIMATE _ / V - Design Location TMY She IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE CO INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1200 9600 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heatec 1 Main 1200 9600 Yes 1 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 142.5 It 0 1200 ft' _ 0.2 0 0.8 ROOF V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emilt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Composition shingles 1265 ft' 0 ft Medium 0.92 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 0 1200 ft' N Y CEILING # Ceiling Type Space R-Value Area Framing Fmc Truss Type 1 Under Attic (Vented) Main 30 120011' 0.11 Wood 3/15/201311:22 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 S —2 W —3 N 4 E Exterior Concrete Block - Int Insul Main Exterior Concrete Block- Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main 4.1 24 0 8 0 192 ft' 4.1 27 3 8 0 218 ft' 4.1 44 0 8 0 352 ft' 4.1 27 3 8 0 218 f12 0 0.01 0 0.01 0 0.01 0 0.01 0 0 0 0 DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 2 S Insulated Main N Insulated Main None 0.4 3 0 None 0.4 3 0 6 8 6 8 20 ft' 20 ft' WINDOWS Orientation shown is the entered. Proposed orientation. / V # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 1 _ 2 _ 3 4 S 1 Metal Double (Tinted) Yes S 1 Metal Double (Tnted) Yes E 4 Metal Double (Tinted) Yes S 1 Metal Double (Tinted) Yes 0.65 0.27 13.33333 1 ft 0 in 6 R 6 in 0.65 0.27 20 ft' 1 It 0 in 6 ft 6 in 0.55 0.27 8 ft' 1 It 0 in 4 It 6 in 0.65 0.27 13.33333 1 ft 0 in 6 It 6 in Drapesiblinds Drapes/blinds Drapes/blinds Drapes/brrnds None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehcuse Best Guess 0.000500 1573.8 86.400 162.48 0.3650 9.8363 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 7.8 18.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit None SEER: 13 24.2 kBtu/hr 726 cfm 0.77 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.92 40 gal 70 gal 120 deg None 3/15/2013 11:22 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 ' SOLAR HOT WATER SYSTEM I V FSEC Cart # Company Name None None Collector Storage System Model # Collector Model # Area Volume FEF ft' DUCTS Supply — Return — Air Percent HVAC # V # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 Attic 6 232.2 it Main 58.05 it Default Leakage Main (Default) (Default) % 1 1 TEMPERATURES Programable Thermostat Y Ceiling Fans: Cooling Heating Jan [[ ]� Feb [[ ]] Mar [X] Jan [X] Feb [X] Mar ] Apr E ] Apr [ ] Ma n Jun n Jul [ ] May ] Jun ] Jul n Aug)() [ ]Au[ Se ]Sep [[[ Oct Oct WNW Nov [X] Nov [ � [X] Dec Dec Venting [I ]1 Jan [Ol Feb L[�x1) Mar (x) Apr [ 1 Ma 1 Jun ) Jul E E I 1 Aug I 1 Se Oct (xl Nov I I Dec Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 6 Hours 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 -78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 - 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/152013 11:22 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 7606 FORT WALTON AVE. PERMIT #: FORT PIERCE, FL, 34951- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402A, To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: / gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental / electric heat must prevent supplemental heat when compressor can meet the load. Duds 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and / sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker j (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4116/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two j or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 3115I2013 11:22 AM EnergyGaugeO USA - FlaRes2010 Section 405A.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 67 The lower the EnergyPerformance Index, the more efficient the home. 7606 FORT WALTON AVE., FORT PIERCE, FL, 34951- 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int lnsul,-Exterior R=4.-1 980:0082 b. WA R= ft2 3. Number of units, if multiple family 1 a N/A R= ft2 4. Number of Bedrooms 2 d. WA R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Roof Deck (Vented) R=0.0 1200.00 ft2 6. Conditioned floor area (112) 1200 b. WA R= ft2 7. Windows" Description Area c. WA R= ft2 a. U-Factor. Dbl, U=0.65 46.67 ft2 11. Ducts a. Sup: Attic, Ret Main, AH: Main R IF 6 232.2 SHGC: SHGC=0.27 b. U-Factor. Dbl, U=0.55 8.00 ft2 SHGC: SHGC=0.27 c. U-Factor. WA - SHGC: d. U-Factor: WA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. WA c. N/A ft2 ft2 1.000 ft. 0.270 Insulation Area R=0.0 1200.00 ft2 R= ft2 R= ft2 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on ,installed Code cort:, features. Builder Signature: Date: 3/�`i / 3 Address of New Home: �2� <j S w S �� �` y Q ✓! City/FL Zip: Q 5 t 3 y p,s 3 kBtu/hr Efficiency 24.2 SEEf213.00 kBtu/hr Efficiency 18.2 HSPF:7.80 Cap: 40 gallons EF: 0.92 CF, Pallet *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Air System Sizing Summary for New Unit Project Name: Ross_7606 Fort Walton Ave 03/13/2013 Air System Information Air System Name .._..._------..___..... __...... _.......... Now Unit Equipment Class ------------------------- SPILT AHU Air System Type .................................... ....___.._......... SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM _—_._._ Sum of space alrflnw, rates Space CFM _... —_....... Individual peak space loads Central Cooling Coil Sizing Data Total mil load Total mil load _.—...—------ —_.._...—.__ 23.4 Sensible mil load __..._....__......._-----17.9 Coil CFM at Jul 1700--- _._--- _,........_.._._.._..._......___... 919 Max block CFM _—..—.._____.__ 919 Sum of peak zone CFM...........___—.__._..___....._-_ 919 Sensible heat ratio ._—_ 0.765 ft2/ron—_--_----_—_.__-- 615.3 BTU/(hr-W)—------ ---------- ----- --------------- 19.5 Water flow Q 10.0'F rise —....__—..._—._ NIA Number of zones .._-_.—._.._._...____...__..__.___-------- 1 Floor Area __._.__.__.._.—__.....___.__. 1200.0 ft2 Location...___._..._.____.....__... West Palm Beach, Florida Calculation Months Sizing Data -------.--_ to Dec Tons Load occurs at _.__..--..—_._— .— Jul 1700 MSH OA DB/WB..._.._.--._._..—___.._—.-89.7177.7 'F MBH Entering DB / WB..__..--__...—_---------- _.._------ 75.6165.0 'F CFM Leaving DB / WS............... ...... — -------- ----- _—_.57.5156.6 'F CFM Coil ADP __.___ _—... 55.5 'F CFM Bypass Factor _._......_—----- __------------------------------ _--- 0.100 Resulting RH _._._......_. 56 % Design supply temp .— ------ —....__._____._._..._.. 58.0 'F Zone T-stat Check --__—_.__...__ 1 of 1 OK Max zone temperature deviation ___...__.._...__._ 0.0 'F Central Heating Coil Sizing Data Max mil load .................... ............. _....... _..12.9 MBH Coil CFM at Des Htg----- _.—...._....._—_---- —_.—_.919 CFM Max mil CFM. 919 CFM Water flow @ 20.0'F drop ._....----- -- NIA Supply Fan Sizing Data Actual max CFM ___._—___..—_—.— 919 CFM Standard CFM ___.._..--___—__ 918 CFM Actual max CFM/fN--- —--------- _-------- _----------------- --0.77 CFM/02 Outdoor Ventilation Air Data Design airflow CFM ..._.—..__..__._._._.—.._.__D CFM CFM/ft Load occurs at.... BTU/(hr-ft')-- Ent DB / Lvg DS Fan motor BHP Fan motor kW _ _.. Des Htg __ 10.8 70.1 / 83.1 'F 0.13 BHP 0.10 kW 0.60 in wg 0.00 CFM/person Hourly Analysis Program v.4.4 Page 1 of 1 Florida Code Summary Report MRS. PARICIA ROSS Title: ROSS New House Project TMY City: FL_ST_LUCIE_Co I 7606 FORT WALTON AVE. FLAsBuilt Elec Util: EnergyGauge Default FORT PIERCE, FL, 34951- Gas Util: EnergyGauge Default I� Registration #: Run Date: Energy Uses Reference Home Proposed Home a -Ratio Heating 0.96 MBtu 0.68 MBtu 0.70 Cooling 8.11 MBtu 4.51 MBtu 0.56 Hot Water 7.15 MBtu 7.15 MBtu 1.00 Total 16.22 MBtu 12.34 MBtu 0.76 Building Loads Reference Home Proposed Home a -Ratio Heating 1.62 MBtu 1.14 MBtu* 0.70 Cooling 20.34 MBtu 11.31 MBtu* 0.56 Hot Water 6.53 MBtu 6.54 MBtu* 1.00 Total 28.49 MBtu 18.99 MBtu 0.67 * normalized modified loads Glass/Floor Area: 0.046 Total Proposed Modified Loads: 18.99 PASS Total Reference Loads: 28.49 3/15/2013 11:22 AM EnergyGauge® USA - RaRes2010 / Page 1 of 1