HomeMy WebLinkAboutEVALUATION REPORTFile Cope
�1 Certificate of Authorization No. 29824
CRE�,y rive
REVIEWED FOR 1752Tamlpa,FL33647
�"'y C®DE COMPLIANCE (813)480-3421
TECHNICAL SERVICES, Wf'LUCIE COUNTY
EVALUATION REPORT
B(DIS r BUILDING CODE, bra EDITION
Manufacturer: TAMKO BUILDING PRODUISrjED
P.O. Box 1404 BY
Joplin, MO 64802 (417) 624-6644 St. Lurie bounty
http://www.tamko-com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Undedayments
Code Sections: 1507.1.1
Properties: Physical properties
issued October 19, 2017
PRODUCT DESCRIPTION
TAMKOO ASTM Slate
ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated
with asphalt and surfaced with granules.
Surfaced Roll Roofing
with asphalt and coated on both sides
TAM KOO ASTM Tile
ASTM D 6380, Class M, Type It undedayment constructed from an organic felt saturated
with asphalt and surfaced with granules.
Underlayment
with asphalt then coated on both sides
TAMKOO Master
ASTM D 6380, Class S, Type IV undedayment constructed from an organic felt saturated
asphalt and surfaced with a fine mineral. For
Smooth
with asphalt then coated on both sides with
use in non-HVHZ only.
TAMKOOMoisture Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard@ with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO@ No. 15 ASTM ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO No. 15 UL ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO@ No. 30 ASTM ASTM D 226, Type It underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO@ No. 30 UL ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO@ TW Metal and Seif-adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO@) TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKTAMKO BUILDING PRODCUTS, INC.
G TAMKO Undarlayments
0 TECHNICAL SERVICES, LLC
TAMKO® TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non -
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the -deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKO®TW Metal and Tile Underlayment and TAMKO®TW
Undedayment shall be 407.
b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35"F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKO@ ASTM Slate Surfaced Roll Roofing shall be 2:12.
Undedayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKOO TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
C
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
A!!o,.,er,le Roof Coverin -:
Metal Roof
Mineral
Wood ,
_
Asphalt
Panels and
Surfaced Roll
Shingles and
Slate
Clay and'.
Underlayment
Shin les
Shinales
-Roofing
Shakes
Shingles
Concrete Tile
TAMKOO ASTM Slate
Y'
N
N
N
N
Y
Surfaced Roll Roofing
TAMKOS ASTM Tile
N
N
N
N
N
Y
Underlayment
TAMKOO Master Smooth
YI
N
N
N
N
N
TAMKOO Moisture Guard®
Y
N
N
N
N
N
TAMKOS No. 15 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y'
N
N
Felt
TAMKOO No. 15 UL Asphalt
Y
Y
Y
Y'
Y
N
Saturated Organic Felt
TAMKOO No. 30 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y
Y
Y
Felt
TAMKOS No. 30 UL Asphalt
Y
Y
Y
N
Y
N
Organic Felt
ZSaturated
K Metal and Tile
Y
Y
N
N
N
Y
Underlayment
_UVKOWTWUnderlayment
Y
Y
N
N
N
N
TAMKOSTAM-FELT
Y
N
N
N
N
N
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
G R E E K TAMKO BUILDING PRODCUTS, INC.
TAMKO Undarlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application :nstructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies (TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies (TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies (TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies (TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies (TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC(TST9628) 13CA12269 ASTM D 226 2009
TBP14001.4
3 of
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product artributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, a Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
�• No 74021
�0 STATE OF :��
��i�tciS O R � �• N,�.
A't
CERTIFICATION OF INDEPENDENCE
2017.10.19
%2 12:15:58
04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.4 FL12328-RB Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.