Loading...
HomeMy WebLinkAboutPLANSGeneral Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +/- 1%- ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER - OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE.OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR 2.ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 1 WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE 6rh EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN 010 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER. 6. VINYI, AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH"": DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. 1 "X2"XO.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #IOX 12" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: L ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON. HILTI, RAWL, TAPCON,REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER, FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. S. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS 0-185. U. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 12" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & I-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 (CHAPTERS 16.20 & 23) F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE. MORE COMMON ABBREVIATIONS. L TYP-TYPICAL 2. SIM- SIMILAR 3. UON-UNLESS OTHERWISE NOTED 4, CONT-CONTINUOUS 5. VIF - VERIFY IN FIELD G. RESPONSIBILITY: L ALL SITE WORK SHALL BE PERFORMED BY LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE 61h EDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 5. SCREENING MATERIAL SHALL BE 18X14XO.O13 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. 6. PLEASE NOTE: 2x2 (typ) DIAGONAL BRACING SHALL BE 2"X2"XO.055" MATERIAL, UNLESS OTHERWISE NOTED ON S-2. DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: SCREEN ROOF: N/A SCREEN WALLS: 31 PSF SOLID ROOF (MWFRS): 25 PSF JUL 2 6 ='019 ST, kUele Cvuncy, PeFmImIng ISO MPH 116 MPH 1 B 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18XAX0013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 3001b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 8. EXISTING SLAB AND OR FOOTING MEETS T14E REQUIREMENTS TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE : NIA 10. SOLIDROOF TYPE: 3"X48"X0.024" ELITE EPS COMPOSITE PANEL ROOF Ilb FOAM DENSITY, FI,ORIDA PRODUCT APPROVAL, FL 7561.R-4. ALUMINUM STRUCTURAL MEMBERS i HOLLOW SECTIONS 2 x 2:----------------------------------2„ x 2" x 0.044„ 2 x 3:---------=-----------------------------2" x 3" x 0.050„ 2 x 4:-------------------------------------2" x 4" x 0.050„ 2 x 5----------- ------------------------2" x 5" x 0.050„ 3 x 3--------------------------------------3„ x 3" x 0.125" OPEN BACK SECTIONS 1 x 2:--------------------------------------- 1" x 2" x 0.040„ 1 x 3:-------------------------------------1" x 3" x 0.045„ SNAP SECTIONS 2 x 2 SMS:-------------------------------2" x 2" x 0.045" 2 x 3 SMS----------------------------------2" x 3" x 0.072" 2 x 4 SMS--------------------------------- 2" x 4" x 0.045" 3 x 3 SMS--------------------------------- 3" x 3" x 0.090" SELF MATING fSMB 2 x 4 SMB:-------------------- 2" x 4" x 0.044" x 0.100" 2 x 5 SMB----------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB----------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB----------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB----------------------- 2" x 8" x 0.072" x 0.224" 2 x 9 SMBr--------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB: --- ------------ --- 2" x 10"x 0.092" x 0.374" TUBE SECTIONS 2 x 2:---------------------------------------2„ x 2" x 0.09011 � Igo?-o13 REVIEWED FOR CODE COMPLIANCE ST, LUCIE COUNTY BOCC ✓Y• 1 d +. CHI p ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(B66)824-7894 E-mail-erb@fbcplans.com Website-www.fb cplans.com C.O.A. #29054 DATE: 7/3/2019 DRAWN BY: TLK REVISION: I DATE: RO 1 1 IKI , Job# 19_0628_444 PROJECT ADDRESS: 4 RAMIE LANE IRT ST. LUCIE, FL 34752 CONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES S-1 .. �Illlllr�. y.. REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY �: 3 r1o.888 7j�f 111I1111�\ ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineeril Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fbcplans.com C.O.A. #29054 DATE: 7/3/2019 DRAWN BY: TLK REVISION: DATE: R01 RO 2 RO 3 RO 4 CT ADDRESS: 4 RAMIE LANE )RT ST. LUCIE, FL 34752 ]ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 FLOOR PLAN S-2 .�\1111111 i, ALUMINUM RISER PAN 010 SMS W/ 1"0 NEO-WASHERS (4) #to SMS W/ 3/4" @ B" O.C. (USE SCREW LENGTH WASHERS PER 12" PANEL EQUAL TO COMPOSITE PANEL THICKNESS PLUS(1)INCH) \ SEE DETAIL C2 ALUMINUM RISER F (2) -1/4" 0 MACHINE BOLTS WITH 3/4" POST AND EDGE BEAM CONTINUOUS EDGE Detail C2 OPTIONAL 1" X 2" FASTENED TO COLUMN WITH (2) 910 X 2" SMS INTO SCREW BOSSES AND FASTENED TO EDGE BEAM WITH (1) #10 X 1.1/2" SMS WITHIN 6" OF COLUMN AND @ 24" O.C. MAX NOTE: EDGE BEAM (SEE SHEET S-2 FOR SIZE) SHALL BE ORIENTED IN DIRECTION SHOWN. / J \ ROOF PANEL TO EDGE BEAM CONNECTION DETAIL S_3 SCALE:NTS 2" x— END BEAM (SEE SHEET 3-2 FOR SIZE) 2" x _" END BEAM ATTACHED TO I'W" OPEN BACK W/ (4) #10 x 2" THRU SCREW BOSS #10 X 3/4" SMS ANGLE TO COLUMN (TIT EACH SIDE) (B) - CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE(TYP EACH SIDE) (SEE ANCHORSPA (MIN) (TYP)(SEE T, Column Size 1/4"& 3/8" 0 Concrete Screw Anchor B Min. Spa 2x3-1/4" 2x4-1/4" 1 2x5-1/4" 1 3 2x6-3 8' 2x7-3/8" 1 2x8�/8' 2 2x9-3/8" 2 2x10-3/8" 2 4.5' HINGE EXISTING MASONRY WALL GROUTED SOLID 2" x 2" 1 @ CONNECTION 1/4"0 X 2-3/4" EMBEDMENT MASONRY SCREW 3" FROM END & @ 24" O.C. "X2" OPEN BACK NOTE: WHEN ATTACHING TO WOOD STRUCTURES, WOOD LAG SCREW ANCHOR DESIGNS SHALL BE OF IDENTICAL SIZE AND EMBEDMENT AS THAT OF MASONRY ANCHOR SCREWS. S2 END BEAM TO HOST STRUCTURE DETAIL S_'3 SCALE:NTS HINGE HINGE SECONDARY ANGLE MIN 0.125" THICK (NOT REQUIRED FOR 2X3 PRIMARY 2" X 2" X0.125"ANGLE (2) #10 X 3/4" SMS FASTENING COLUMN TO PRIMARY ANGLE O (TYP EACH SIDE) O I1" X 2" BASE MEMBER O (TYP EACH SIDE) CONCRETE SCREW (SEE TAB LE) ANCHOR INTO PRIMARY ANGLE AND @ 1/4" 0 CONCRETE 3" (MIN) SCREW ANCHOR@ 24" O.C. BETWEEN COLUMNS (TYP EACH SIDE) NOTES: 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE IX2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ON S-11 D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED BY ENGINEER. 4. 2X3W/IX2 CORNER POSTSHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. \2"x3" OR LARGER UPRIGHT TO CONCRETE W/WO PAVER DETAILS S_3 SCALE:NTS DOOR x 2" EXTRUSION NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 x 5/8" SMS MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE W/(2) HINGES MINIMUM. 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)910 x 5/8" SMS. FASTEN A 1" x 2" x 0.044" TO UPRIGHT W/#12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. rF TYPICAL SCREEN DOOR CONNECTION DETAIL S_3 SCALE: NTS OPTION #1 OPTION #2 2"X2" OR 2"X3"_I 0.062" ALUMINUM INTERNAL OR MEMBER EXTERNAL #10 X 3CEIVING 4"INTO INTO BEAM B AM)OR UPRIGHT. (2) 414X 3/4' EA. LEG INTO GIRT OR PURLIN- (0.062" ANGLE CLIPS W/ (2) #14x3/4" SMS EA LEG) UPRIGHT OR BEAM -SNAP OR SELF MATING OR HOLLOW I/ H \1 PURLIN OR GIRT TO BEAM OR POST DETAIL S'3 SCALE:NTS HOSTSTRUCTURE BREAK FORM HEADER OR ECEIVING CHANNEL 410 SMS AT EACH RISER OR PAN OR#10 SMS@ B" O.C. FOR COMPOSITE PANEL --SOLID ROOF / \#10SMS@B"O.C. ' FOR COMPOSITE PANEL (2) #10 SCREWS PER 12" WIDTH CONNECTING PAN TO HEADER (BOTTOM OR BACK OF PAN) 910 X 2" SCREWS PER 12" WIDTH CONNECTING SDER OR CHANNEL TO FASCIA. S1 ROOF PANEL TO FASCIA CONNECTION DETAILS S_3 SCALE:NTS REVIEWED FOR CODE COMPLIANT ST. LUCIE COUN1 Ate,.......; 3 No.B �o ; ?40 1111100. A%l l 11, 0a \\` PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-www.fbcplans.com C.O.A. #29054 IDATE: 7/3/2019 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 R0 3 RO 4 CT ADDRESS: 4 RAMIE LANE )RT ST. LUCIE, FL 34752 ]ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-3 1/4" 0 x 2"-1/2 MASONRY ANCHOR IF WOOD SUBSTITUTE IDENTICAL / WOOD SCREW OR LAG 6" FROM TOP & BOTTOM & @ 24" O.C. I �1"X2"OPEN BACK ' 2"X2"X0.062 ANGLE W/(4) 012X3/4"SMS INTO I 172"OPEN BACK & (1) I� 1/4"0 x 2 1/2" EMBEDDED MASONRY ANCHOR & @ 6" / FROM END -IF WOOD SUBSTITUTE IDENTICAL SIZED LAG 172"OPEN BACK - H1 OPEN BACK TO HOST STRUCTURE DETAIL S-4 SCALE:NTS OPTIONAL: 1"X2"OPEN BACK ATTACHED TO HOST (H)-#14X 3/4"SMS W/ (1) 1/4" 0 CONCRETE ATTACHING ANGLE TO BEAM SCREW OR LAG WITHIN 6" EACH SIDE (1" MIN. SPACING) OF BEAM & @ 24" O.C. MAX , S BETWEEN BEAMS i E0 . m 2X(H) SMB '-' 0 (B) -1/4" 0 CONCRETE SCREW G W/ 1-1/2" EMBEDMENT INTO G 0 MASONRY (1-1/2" MIN. SPACING OR (B)-1/4" 0 X 2" LAG SCREWS SLOPED OR FLAT INTO WOOD (1" MIN SPACING) ROOF BEAM (SEE (TYP 2 LOCATIONS) SHEET S-2 FOR SIZE) BEAM "B" NOTES: 2"X2"X 0.125"ANGLE 1. THE MINIMUM EDGE EA. SIDE OF BEAM 2x4 1 DISTANCE IS 3" FOR MASONRY EXISTING HOST STRUCTURE 2x5 2 STRUCTURES. (CONCRETE, GROUT FILLED 2. IF A RECEIVING CHANNEL IS CMU OR WOOD) 2X6 2 USED, USE TWICE THE NUMBER 2x7 3 "B" ANCHORS INTO THE HOST STRUCTURE. ALL MINIMUM 2X8 3 SPACING SHALL BE APPLICABLE. 2X9 3 S3AA BEAM TOHOSTTOCONli6(�NNRta��lalE,D FOR 2X1D 4 S- y SCALE: NTS CODE, COMPLIANI ST. LUCIE COUM \\\\ MAX n ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE:86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineerir Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-www.fb cplans.com C.O.A. #29054 DATE: 7/3/2019 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 P fffltrf4ADDRESS: CLARK 214 RAMIE LANE PORT ST. LUCIE, FL 34752 K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-4