HomeMy WebLinkAboutPLANSGeneral Notes A. CONCRETE & FOUNDATION DESIGN- 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS, 3. FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERIAESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRAD 60 (60 KSI MIN.) DEFORMED BARS, 43 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE I.- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING+/- 1 % - ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: I.CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2.ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4YROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-TS FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN' OR "PART 1-B - SPECIFICATIONS FOR U ALUMIIM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN' OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE 6rh EDITION ( CHAPTER 16 STRUCTURAL -DESIGN & CHAPTER 20 IN ALUMUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN 010 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING 412 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH" . DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. 1 "X2"X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #IOX 1/2" EMBEDMEaNT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: I. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BTA OL•i_ __.S TO BE ASTM A 325, PLATED WITH SNDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HRTL RA WL, TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT E GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER v. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINDAUM CENTER -TO -EDGE SHALL BE I/2" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 CURRENT ASCE7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART I -A, & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 6rh EDITION (CHAPTERS 16, 20 & 23). . ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP-TYPICAL 2. SIM -SIMILAR 3. UON - UNLESS OTHERWISE NOTED 4. CONT-CONTINUOUS 5. VIF -- VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: I. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE -FAR HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4714 WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING ING BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE 6rh EDITION R 4501.17IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 5. SCREENING MATERIAL SHALL BE 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. 6. PLEASE NOTE: 2x2 (typ) DIAGONAL BRACING SHALL BE 2"X2"X0.055" MATERIAL, UNLESS OTHERWISE NOTED ON S-2. DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED V1d: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: SCREEN ROOF: N/A SCREEN WALLS: 43 PSF SOLID ROOF,(MWFRS): 36 PSF JUL 2 6-'q4;9 ST, Lucie County, ISO MPH 116 MPH I C 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR I8X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVELOAD: 3001b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 8. EXISTING SLAB AND OR FOOTING MEETS THE REQUIREMENTS TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: N/A 10. SOLIDROOF TYPE: 3"X48"X04024" ELITE EPS COMPOSITE PANEL ROOF 2Ib FOAM DENSITY, FLORIDA PRODUCTAPPROVAL FL 756111-4 ALUMINUM STRUCTURAL MEMBERS HOLLOW SECTIONS 2 x 2----------------------------------------2„ x 2" x 0.044„ 2 x 3:--------------------------------------2" x 3"x 0.050" 2 x 4:--------------------------------------2„ x 4" x 0.050" 2 x 5---------------------------------------2" x 5" x 0.050" 3 x 3:-----------------------------------3„ x 3" x 0.125" OPEN BACK SECTIONS I x 2:---------------------------------------- 1" x 2" x 0.040„ 1 x 3:-------------------------------------1" x 3" x 0.045" SNAP SECTIONS ' 2 x 2 SMS: -------------- ------------------ 2" x 2" x 0.045" 2 x 3 SMS:--------------------------------2„ x 3"x 0.072„ 2 x 4 SMS------------------------------- 2" x 4" x 0.045" 3 x 3 SMS:--------------------------------- 3" x 3" x 0.090" SELF MATING fSMB 2 x 4 SMB:--------------------- 2" x 4" x 0.044" x 0.100" 2 x S SMB:--------------------- 2" x 5" x 0.050" x 0.11B" 2 x 6 SMB:--------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:--------------------- 2" x 7" x 0.057" x 0.120" 2 x B SMBr--------------------- 2" x B" x 0.072" x 0.224" 2 x 9 SMB----------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB-------------------- 2" x 10" x 0.092" x 0.374" TUBE SECTIONS 2 x 2-------------------------------------2" x 2" x 0.090" SCARY r-M St- LucieCounty IR�7-os��l REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC 3I� is �''��SLsroFIA�-�� `�• ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineerir Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)7BB-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-ww W,fbcp)ans. com C.OA. #29054 DATE: 6/20/2019 DRAWN BY: TLK REVISION: DATE: RO 1 I RO2 1 1 IRO3 I Job# 190619283 PROJECT ADDRESS: COHEN 631 WOODCREST DRIVE FT PIERCE, FL 34945 ::ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES S-1 J t 1-0'Ir 0 I i� 0 I REVIEWED FOR CODE COMPLIANCE �T. LUCIE COUNTY BOCC 1' A. / / r ♦\ ,:,,MAX ��� 6 3 ( w OVF FLIDR��bP "/7'/"�Sl O N JXV% 'N\�♦ ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-w .tbcplans.com C.OA. #29054 DATE: 6/20/2019 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 CT ADDRESS: COHEN 631 WOODCREST DRIVE FT PIERCE, FL 34945 "ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 FLOOR PLAN S-2 ALUMINUM AISER PAN 3"SOLID (4) 410 SMS W/ 3/4" ROOFPANEL WASHERS PER 12" PANEL #10X 4" SMS ------------------------- -_--_----___-_---_--_-- Detail C2 - - - - - 1-1/4- NEOPRENE NASHER 8" O.C. PER 3"SOLID ROOF PANEL - -_ -_2"X2"X3"X 0.62" _ - - -__- W/(2)#12X -_ - -_ 4AIKONTINUOUS __ANGLE -_ EDGEBEAM 3/4"EA. LEG - -SLICE I II #1OX4"SMSTHRU EDGEBEAMINTO 2"X"X0.050"EDGE BEAM POST SCREW BOSS 1"ONTINUOUS(SEE S-2 FOR ADDED TO EDGE SIZE) EDGE BEAM SPLICE BEAM W/(2) #10 X' WSMS&TOEDGe II (41#lOX 4"-MIN.—_--_—_---_—__—_----_--_ BEAM W/ X C IF I I I I SMS 12- 12'C/CIF INTO SCREW BOSS .. .. ---_—_--_-- .. .. - .. .. - _—_----_--_ TRIBUTARY II I --------- ----__—__ BETWEEN POST EXCEEDS 6'.6" OR ISOMPH"C" II II 11 2"X_2XO.050"UPRIGHT (SEE S-2 FOR SIZE) 2"X2"X3"X 0.62" (4) 41OX4" SMS THRU I ANGLE W/ (2) 4*12X SIDE VIEW EDGE BEAM INTO 3/4" EA. LEG POST SCREW BOSS EDGE BEAM SPLICE �\ / J \ ROOF PANEL TO EDGE BEAM CONNECTION DETAIS S_3 SCALE:NTS 2"x_END BEAM (SEE SHEET 3-2 FOR SIZE) 2" x" END BEAM ATTACHED T_O 1"XZ" OPEN BACK W/ (4) #10 x 2" THRU SCREW BOSS (4) 410 X 3/4" EMS FASTENING SECONDARY ANGLE TO COLUMN MA EACH SIDE) (B) - CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE(TYP EACH SIDE) (SEE 0 C TABLE) O O ANCHOR'' Column Size 1/4"& 3/8" 0 Concrete Screw Anchor B Min. Spa 2x3-1/4" 0 0 2x4-1/4" 1 3" 2x5-1/4" 1 3" 2x6-3/8" 1 4" 2x7-3/8" 1 5" 2x83/8" 2 3 2x9-3/8' 2x10-318. 2 2 4' 4.5" HINGE EXISTING MASONRY WALL GROUTED SOLID 2" x 2" l @ CONNECTION 1/4"0 X 2-3/4" EMBEDMENT MASONRY SCREW 3" FROM END & @ 24" O.C. "X2" OPEN BACK NOTE: WHEN ATTACHING TO WOOD STRUCTURES, WOOD LAG SCREW ANCHOR DESIGNS SHALL BE OF IDENTICAL SIZE AND EMBEDMENT AS THAT OF MASONRY ANCHOR SCREWS. S2 END SEAM TO HOST STRUCTURE DETAIL S-3 SCALE:NTS HINGE HINGE SECONDARY ANGLE MIN 0.125" THICK (NOT REQUIRED FOR 2X3 MEMBER) PRIMARY 2" X 2" X 0.125" ANGLE (2) #SOX 3/4" SMS FASTENING COLUMN TO PRIMARY ANGLE (TYP EACH SIDE) 1" X Z" BASE MEMBER (TYP EACH SIDE) (1) - CONCRETE SCREW (SEE 'd TABLE) ANCHOR INTO PRIMARY ANGLE AND .@.1/4" 0 CONCRETE 3" (MIN) SCREW ANCHOR @ 24" O.C. BETWEEN COLUMNS NOTES: (TYP EACH SIDE) 1.NUMBER OF ANCHORS"B"IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE IX2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ON S-1, D.FASTENERS, OTHER BRAND& TYPE SHALL BE APPROVED BY ENGINEER 4.2X3 W/IX2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. 2" x 3" OR LARGER UPRIGHT TO CONCRETE W/WO PAVER DETAILS S_3 SCALE:NTS DOOR x 2" EXTRUSION NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) 910 x 5/6" SMS MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2) HINGES MINIMUM. 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS. FASTEN A 1" x 2" x 0.044" TO UPRIGHT W/912 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM END OF THE UPRIGHT. (TYPICAL SCREEN DOOR CONNECTION DETAIL S-3 SCALE: NTS OPTION #1 OPTION #2 2"XZ" OR2"X3"J I 0.062" ALUMINUM INTERNAL OR MEMBER EXTERNAL RECEIVING CHANNEL LBEAM W/(4)#10X3/4"INTO INTO OR UPRIGHT. (2) 414X 3/4 EA.LEGINTO GIRT ORPURLIN - (0.062" ANGLE CLIPS W/ (2) #140/4" SMS EA LEG) UPRIGHT OR BEAM -SNAP OR SELF MATING OR HOLLOW L H PURLIN OR GIRT TO BEAM OR POST DETAIL S 3 SCALE: PITS BREAK FORM HEADER OR RECEIVING CHANNEL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P. FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineeril Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-www.fb cplans.com C.OA-#29054 DATE: 6/20/2019 #10 SMS AT EACH RISER DRAWN BY: TLK OR PAN OR #10 SMS @ 8' O.C. FOR COMPOSITE PANEL REVISION: DATE: ° OLID ROOF RO 1 RO 2 RO 3 RO 4 d Job# 19_0619_283 #IO SMS POSITS FOR COMPOSITE PANEL PROJECT ADDRESS: (2) #10 SCREWS PER 12" WIDTH CONNECTING C13HEN 631 WOODCREST DRIVE PAN TO HEADER(BOTTOM FT PIERCE, FL 34945 OR BACK OF PAN) (2) 1/4' MASONRY ANCHORS PER 12" WIDTH CONNECTING CONTRACTOR: HEADER OR CHANNEL TO HOST. K & S INDUSTRIES, INC. 51 ROOF PANEL TO FASCIA CONNECTION DETAILS S 3 SCALE:NTS 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 REVIEWED FOR DETAILS CODE COMPUANCE S - 3 BOCC