Loading...
HomeMy WebLinkAboutENGINEERING - TESTING•-tr RECEIVED ENGINEERING & TESTING, INC. JUL 2 6 Z019 Phone: (866) 781-6889 oFax: (866) 784-8550 ST. Lucie County, Permitting ��'ww.floridaengineeringandtesting.coms 250 S.W.13 Avenue Pompano Beach, FL 33069 DATE: 7/24/19 JOB ORDER #: 19-3585 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce, FL 34982 PROJECT: JBM Property Mgmt. Flat Wood Non -Insulated Roof Deck ADDRESS: 2211 N 441 Street Fort Pierce, FL SCANNED 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS 13Y St. Ludeft* Project Information: Height = 9' Exposure: C Length = 43' Category: Il Width = 18' Slope: < 7° Parapet Wall: N/A Residential Basic/Ultimate Wind Speed: Vic=163 mph Nominal Wind Speed: V.d=V dt*10.6 (asd = allowable strength design) KZ = 0.85, Kzt =1.0, Kd = 0.85 Design Calculations: FILE Velocity Pressure: q = 0.00256*KjQtKdV2 Velocity Pressure (uit): q=0.00256(0.85)(1.0)(0.85)(163)Z = 49.14 psf Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(163*�0.6)2 = 29.49 psf . Width of Pressure Coefficient: 0.f(18') = 1.8' 0.4(9') = 3.6' ) use: 3'0" Effective Wind Area: <lW For parapet height three feet (3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) Wee .-u �' Q `v Quality — $asurance \, GCPi = 0.18 Page 2, 7/24/19, Job Ord 7 Z'=>19-3585 All Area Roofing - JBM Property Mgmt. Flat Wood Non Insulated Roof Deck 2211 N 44th Street; Fort Pierce, FL: Design Pressures Based on Vasd: 1) Field 2) Perimeter 3) Corners Attachment Requirements: P1 = 29.49*[(-1.0) — (0.18)] = -34.8 psf P2 = 29.49*[(-1.8) — (0.18)] = -58.4 psf P3 = 29.49* [(-2.8) — (0.18)] = -87.9 psf =71"WIR I The system is acceptable as approved based on the requirements of Florida Product Approval # FL1654-R24, Appendix 1, page 29 of 69, System No. W-183 with a maximum design pressure of -90 psf. Base Ply: Self adhere one or more plies of Elastoflex SA V Base Ply sheet to the min. 15/32" plywood deck. Cap Ply: Torch apply the Polyflex G Cap Ply sheet to the base ply sheet. Notes: Corners and perimeter area dimension shall not be less than a = TO" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, FBC 2017, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. �,%... IV1iiii11""I Sincerely, Mark A. Mesiano, P Florida Engineering Florida Reg. No. 48, Certificate of Authoj N-AN P . '\,\CE/V —^ 0- 48202 O ¢: 9 STATE OF tt , Y