HomeMy WebLinkAboutEVALUATION REPORTSCANNED
TRINITY ERA St. Lucie County
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
EXTERIOR RESEARCH & DESIGN, U.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT k13
OXFORD, CT 06478
(203)262-9245
Evaluation Report 037940.02.12-RB
FL10674-R13
Date of Issuance: 02/06/2012
Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance(with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Cade Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPEaION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through B.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. w 10/09/2017. This does not serve as an
electronically signed document
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products It evaluates.
2. Trinity l ERD is not owned, operated or control led by any company manufacturing or distributing pro ducts it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a flnancial Interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�I TRINITY I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the 61h Edition (2017) Florida Building Code/and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2011
3. REFERENCES:
Ent
Examination
Reference
Date
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
UL LLC (QUA9625)
Quality Control
Service Confirmation
Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles
4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 DevonshireT" are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration Designer Color
Collection, TruDefinition Oakridge , Oakridge and WeatherGuard HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip & Ridge Shingles:
4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgem Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, U.C. Evaluation Report 037940.02.12.RS
CerOjmte of Authorizatlon#9503 6r"EDITION(2017) FBC NON-HVHZ EVALUATION FL10674-R33
Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017
Page 2 of 8
�I I KINITY ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, Indicating the shingles are acceptable
for use in all wind zones up to Va,d = 150 mph (Vxl, = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vx.d = 150 mph (V„ it =194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
Berkshire shingles require minimum five (5) nails per shingle. _
➢ WeatherGuard HP shingles require minimum six (6) nails per shingle.
Devonshire"' shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing— Starter Strip Shingle and Starter Strip Plus:
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8
Certifimtc n)Autin,draxon 495ar 6'"EDITION (2017)rBC NON-HVHZ EVALUATION F1.30674-1113
Owens Coming Asphalt Roof Shingles Revision 8: 10/09/Z017
Page 3 of 8
6.2.6 Minimum Nailing —Classics&Supreme:
Nomul Mansard or Ana pare
n
Wind Amea High Wlnd dasvanas y
A. pan vbnfos nortnass Amea vl.nr m rearms
—
,r
W Expo..m
Espaaleidn
6.2.7 Minimum Nailing —Berkshires:
Stain s p
la144dttenada
L a vt- ow a Vr
,•
Standard Fastening Pattern
�l I KINITY I ERD
Normal Mansard ar Ara. pare
Wind Ama. High Wind desnnaa y
Amur pans viontos nommlsa Areas viontos Warn.
• rtz W '• '• z' Iel a' ,'
551WExposum
Exposkidn
La AA di Wi
!. toe G vlhdn
l`r B Yf BYf 8 Y1' e Yf I
r
r
r
r AVIian.11no xnenl
Crmanro detxAodt rdelro
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, I.I.C. Evaluation Report O3794D.02.12-R8
CeAl/Imte of Authoritarian 99503 6ieEDITION (2017)FBC NON-HVHZ EVALUATION FL30674-R13
Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017
Page 4 of 8
6.2.8 Minimum Nailing — Devonshire-:
7. I 81. I 8" I. B. I. 7"
Sd18'esposure Sealant latet, It
Ecposiddnda5d18pulg Ublaadiindelsdlador
Standard 6-Nall Fastening Pattern
sr
�I I KINITY ERD
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition
Duration Designer Color Collection:
4 Na11 Fastening Patient
Standard Fastening Pattern
Mansard or Steep Slope Fastening Pattern
Asninn Pane.
smraU ..0 wsNN
6-Nail Fastening Pattern
Exterior Research and Design, U.C. Evaluatlan Repart O37940.02.1Z-RB
Cerflcste ofAuthoritaean a9903 6r"EDITI0N(2017) FBC NON.HVHZ EVALUATION FL10674-R33
Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017
Page 5 of 8
v I KININ I ERD
6.2.1 Minimum Nailing—TruDefinition Oakrldge®, OakridgeO:
4 Nail Pattern
Esquema con 4 dms
t. t•
IF W —H N— r—sl
&Post 6n d' a Nags 5 sff Eaposu; 0
FryoddN, de 66/BOAB Cuvos E Wslddn de 6 V8pdg.
Standard Fastening Pattern
6 Nall Pattern
Esquema con 6 lows
r r
S —11 it-- tY
E 618'Fxpao-ure 0Nlar. 5Wr Exposure
Eepogimi,de66/Bpulg. Egoslddnde 6618lidg.
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard® HP:
6-Nail Fastening Pattern
$Ingle Sidra View
WPM LbnE
F.ftw7hwr wI Lb.
w.ar�r!}dLe
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-RB
Cerufloote ofAuthodfotion N9503 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL30674-R13
Owens Coming Asphalt Roof shingles Revision B: 10/09/2017
Page 6 of 8
'l I KINITY ERD
6_3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles
and Pro Edge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRldge7 Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturers published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing— Berkshire° Hip & Ridge and High Ridge:
Fig. I
cm+a"Md
aRCbn
6.3.4 Minimum Nailing—WeatherGuard® His Hip and Ridge:
Fig. A
F— nlnpbn
clw 19
Wtis
1 I
P I i 1
P 1
i
I 1
t' • T
L� �q
Fig. C Hip & Ridge Shingle Fastening
TdpVW
tblk Valk
T'
3 1'
1° d`
i.
tT ---�
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8
CerWmte of Authorization A9503 6aa EDITION (2017)FBC NON-HVHZ EVALUATION F1.30674-1113
Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction Sealant Strip
6' Exposure
Fasten 71h'
Can' Exposed
Fannies" with
Roof Cement
�l I KINITY J ERD
Standard
—it'--
Fastoning
Pattern
12Sealant
7y` 6' Expose o
6.3.6 Minimum Nailing — DuraRidgen' Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
tfnswod Dlnctim
aiRmif. domimnto duce'
Dimden d.hiana prx ieniamta
7. LABELING:
7.1 Labeling shall be In accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall Indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
B. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named CIA entity for information on which plants produce products covered by Florida Rule 911-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokanla@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C.
Certificate of Authorization a9503 Ern EDITION (2017) FBC NON-HVHZ EVALW
Owens Corning Asphalt Root Shingles
Evaluation Report 037940.02.12-RB
FL10674-1113
Revision 8: 10/09/2017
Page 8 of 8