Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCANNED TRINITY ERA St. Lucie County EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 EXTERIOR RESEARCH & DESIGN, U.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT k13 OXFORD, CT 06478 (203)262-9245 Evaluation Report 037940.02.12-RB FL10674-R13 Date of Issuance: 02/06/2012 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance(with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Cade Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPEaION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through B. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. w 10/09/2017. This does not serve as an electronically signed document CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products It evaluates. 2. Trinity l ERD is not owned, operated or control led by any company manufacturing or distributing pro ducts it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a flnancial Interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �I TRINITY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code/and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Ent Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 DevonshireT" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration Designer Color Collection, TruDefinition Oakridge , Oakridge and WeatherGuard HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip & Ridge Shingles: 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgem Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, U.C. Evaluation Report 037940.02.12.RS CerOjmte of Authorizatlon#9503 6r"EDITION(2017) FBC NON-HVHZ EVALUATION FL10674-R33 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 2 of 8 �I I KINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, Indicating the shingles are acceptable for use in all wind zones up to Va,d = 150 mph (Vxl, = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vx.d = 150 mph (V„ it =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshire shingles require minimum five (5) nails per shingle. _ ➢ WeatherGuard HP shingles require minimum six (6) nails per shingle. Devonshire"' shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing— Starter Strip Shingle and Starter Strip Plus: Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 Certifimtc n)Autin,draxon 495ar 6'"EDITION (2017)rBC NON-HVHZ EVALUATION F1.30674-1113 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/Z017 Page 3 of 8 6.2.6 Minimum Nailing —Classics&Supreme: Nomul Mansard or Ana pare n Wind Amea High Wlnd dasvanas y A. pan vbnfos nortnass Amea vl.nr m rearms — ,r W Expo..m Espaaleidn 6.2.7 Minimum Nailing —Berkshires: Stain s p la144dttenada L a vt- ow a Vr ,• Standard Fastening Pattern �l I KINITY I ERD Normal Mansard ar Ara. pare Wind Ama. High Wind desnnaa y Amur pans viontos nommlsa Areas viontos Warn. • rtz W '• '• z' Iel a' ,' 551WExposum Exposkidn La AA di Wi !. toe G vlhdn l`r B Yf BYf 8 Y1' e Yf I r r r r AVIian.11no xnenl Crmanro detxAodt rdelro Mansard or Steep Slope Fastening Pattern Exterior Research and Design, I.I.C. Evaluation Report O3794D.02.12-R8 CeAl/Imte of Authoritarian 99503 6ieEDITION (2017)FBC NON-HVHZ EVALUATION FL30674-R13 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 4 of 8 6.2.8 Minimum Nailing — Devonshire-: 7. I 81. I 8" I. B. I. 7" Sd18'esposure Sealant latet, It Ecposiddnda5d18pulg Ublaadiindelsdlador Standard 6-Nall Fastening Pattern sr �I I KINITY ERD Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition Duration Designer Color Collection: 4 Na11 Fastening Patient Standard Fastening Pattern Mansard or Steep Slope Fastening Pattern Asninn Pane. smraU ..0 wsNN 6-Nail Fastening Pattern Exterior Research and Design, U.C. Evaluatlan Repart O37940.02.1Z-RB Cerflcste ofAuthoritaean a9903 6r"EDITI0N(2017) FBC NON.HVHZ EVALUATION FL10674-R33 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 5 of 8 v I KININ I ERD 6.2.1 Minimum Nailing—TruDefinition Oakrldge®, OakridgeO: 4 Nail Pattern Esquema con 4 dms t. t• IF W —H N— r—sl &Post 6n d' a Nags 5 sff Eaposu; 0 FryoddN, de 66/BOAB Cuvos E Wslddn de 6 V8pdg. Standard Fastening Pattern 6 Nall Pattern Esquema con 6 lows r r S —11 it-- tY E 618'Fxpao-ure 0Nlar. 5Wr Exposure Eepogimi,de66/Bpulg. Egoslddnde 6618lidg. Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard® HP: 6-Nail Fastening Pattern $Ingle Sidra View WPM LbnE F.ftw7hwr wI Lb. w.ar�r!}dLe Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-RB Cerufloote ofAuthodfotion N9503 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL30674-R13 Owens Coming Asphalt Roof shingles Revision B: 10/09/2017 Page 6 of 8 'l I KINITY ERD 6_3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles and Pro Edge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRldge7 Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturers published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing— Berkshire° Hip & Ridge and High Ridge: Fig. I cm+a"Md aRCbn 6.3.4 Minimum Nailing—WeatherGuard® His Hip and Ridge: Fig. A F— nlnpbn clw 19 Wtis 1 I P I i 1 P 1 i I 1 t' • T L� �q Fig. C Hip & Ridge Shingle Fastening TdpVW tblk Valk T' 3 1' 1° d` i. tT ---� Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 CerWmte of Authorization A9503 6aa EDITION (2017)FBC NON-HVHZ EVALUATION F1.30674-1113 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 7 of 8 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip 6' Exposure Fasten 71h' Can' Exposed Fannies" with Roof Cement �l I KINITY J ERD Standard —it'-- Fastoning Pattern 12Sealant 7y` 6' Expose o 6.3.6 Minimum Nailing — DuraRidgen' Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. tfnswod Dlnctim aiRmif. domimnto duce' Dimden d.hiana prx ieniamta 7. LABELING: 7.1 Labeling shall be In accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall Indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. B. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named CIA entity for information on which plants produce products covered by Florida Rule 911-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokanla@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Certificate of Authorization a9503 Ern EDITION (2017) FBC NON-HVHZ EVALW Owens Corning Asphalt Root Shingles Evaluation Report 037940.02.12-RB FL10674-1113 Revision 8: 10/09/2017 Page 8 of 8