HomeMy WebLinkAboutPRODUCT APPROVALFloridaBuildingtE of 2
SCANNED
I
Business`&Professional Regulatio`
y�
P$G@l 2�.c rDIrR HDYIraIYVrOlVgI 00PRDIYIfIDM]��CDYIaROIrR
byii"r
a
^;I •I' Product Approval
14U tct� USER: Public User
d
uiA.u..
Protluc[ ponmval Man,, > e,DtluU er peellatlen SearcM1 > peoliraaon List > pDDllratlan DotDll
FL #
Application Type
Code Version
Application ILE
Com tr ii/�7
CO
Archlved
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida Ucense
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL10674-1113
Revision
2017
V V
�L� 16 l�� � • �
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg.keeler@owenscoming.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscomlg.com
Roofing
Asphalt Shingles
RECEIVED
JUL 2 6 2019
ST,.Lucle County, Permitting
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert J.M. Nleminen
PE-59166
UL LLC
05/16/2020
John W. Knezevich, PE
Wj Validation Checklist - Hardcopy Received
FL10674 R13 COT 2017 01 COI Nleminen ndf
Referenced Standard and Year (of Standard) Standard
ASTM D3161
ASTM D3462
ASTM D7158
Equivalence of Product Standards
Certified By
Sections from the Code
year
2016
2010
2011
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=vGEVXQwtDgtBNbEY5 V %2boQT... 2/1/2018
Florida Building Code Online
Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
10674.1
Owens Coming Asphalt Roofing
3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge
Shingles and Starters
shingles
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL10674 R13 11 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R73.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert J. M. Nleminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section S.
Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.ndf
Created by Independent Third Party: Yes
oarx Neal
contact Ub:: 2601 Blair Shop Need. Tallahassee F. 32399 Phone: 850187-1824
Tee State of nodda S an ANMO employer. Camrloht 20D7-2013 9bte of Findda.:: Pdvacv SMement :: AccessibaIW StalemnnL: Neemd Statement
Under nodda bw, email addresses are public records. If you do not want your e-mall address relealed in msDo. to a public -records request. do not send
electronic mall to thk antfty. Instead, contact the office by phone or by traditional mall. IrWu have any pumUom, please contact 050.487./395. *Pursuant to
section 455.275(1), nodda Statures, eaedlre Octabe,1, 2012, leemems ocomed under chapter 455, F.S. must provide the Department with an email address It
they have one. The emetic provided maybe used far official communication with the Ikemce. HowNed email addrmsac are public record. If you do not wish to
supply a pereaml address, please provide the Department with an email address which can be made avallable th the public To determine if you are a licensee under
chapter 455, F.S., please click hot;.
Product Approval Accepts:
F an M �- M
Credit Card
Safe
httns://floridabuilding.ore/nr/nr ann dfl.asux?Daram=wGEVXOwtDotBNbEY5V%2boOT... 2/7/2018
Florida Building Code Onlintj Page 1 of 2
Professional Regulafionth � � � " V �Uk� Its ��
� ���� �rAi T .mil S r `YJ.i'�'.T`+'�Y�.Sv1V r oBVM I:o a �I.OWroeM o9oq olvia�o:lr� coNIRCPoePe
dFlorida
,")
� Produce Approval
?vr a .v x USER:Pvbit User
PmAnct Mvmm: firm a P,M rtt Or A0011VOOD SramM1 a pnmtraxnn: lSt> pppaPetlan 0etna
FL #
F1-1654-1123
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
❑
Product Manufacturer
POLYGLASS USA
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext 242
malpert@polyglass.com
�L �- II LoE)U, I
`q —&s-9
JUL 2 6 2019
ST.Ilude
Authorized Signature Maury Alpert FILE
maury Alp olyglass.co
Technical Representative � Maury Alpert
Address/Phone/Small 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912)429-8610
MAlpert@polyglass.cam
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida Ucense
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Roofing
Modified Bitumen Roof System
Evaluation Report from a Florida Registered Architect or a Ucensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
09/13/2021
John W. Knezevich, PE
Vi Validation Checklist - Hardcopy Received
FL1654 R23 COI 2018 01 COI NIEMINEN odF
Standard
Year
ASTM D6162
2008
ASTM D6163
2008
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2009
FM 4470
2012
FM 4474
2011
UL 1897
2012
htto://www.floridabuilding.org/Dr/nr ann dd.asnx?oaram=wGEVXOwtDavaau2wB/o2bnF... 3/25/2019
Florida Building Code Onlinc- -
Page 2 of 2
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/08/2018
Date Validated 10/13/2018
Date Pending FBC Approval 10/21/2018
Date Approved 12/11/2018
Summary of Products
I
FIL 7f
Model, Number or Name
Description
1654.1
PDlyglass SBS and APP
Modified Bitumen Roof
SBS and APP modified bitumen roof systems
Systems
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-622.5
Other: 1.) The design pressure In this application
relates to one particular assembly over concrete
deck. Refer to the ER Appendix for other systems
and deck types. 2.) Refer to ER, Section 5 for
other Limits of Use.
FL1654 R23 II 2018 10 FINAL Al ER POLYGLASS MODBIT FL1654-
R23.gdf
Verified By: Robert Nleminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL1654 R23 AE 2018 10 FINAL FR POLYCI ASS MODBIT FL1654
1123.0d
Created by Independent Third Party: Yes
T.—.ckj fhasl
Cantatt Vs:: 2601 mab some Road. Tallahassee 32399 phone: asose7-11124
The State of RRHda Is an AVEEO employer. Ceenshilm 2007-201 State of Florida ;; pMeev S"na mt e; Amessibalty statement;; Refund Simment
Under Florida law, email addresses are pubic rownds. V you do not want your e-man address released in response th a public-femtds request, do has send elachanlc
.an to this entry. Named, contact the We. by phone or by hadltlonal mall, uyad Imve my questions, please Contact 950,487.1395, `Pursuant to Seteon 455.275
(1), Florida Statutes, efloWn October 3, 2012, Jammes hoomed man, Chapter 455, F.S. must movlde the Dep arnmt with an email address If they have one. Toe
emalls provided may be used for areal communtme on with the Ikons¢¢. However email addmses am public remsJ. If you do not wish to supply a personal address,
Please provide the Department with an email address which an be made available tq the public To determine If,ym am a 0censee under chapter 455, F.S., please
dlck
ProductApproval Aomptas
ME 99 ® PER M
Credit Card
Safe
http://www.floridabuildiniz.org/Dr/ter ante dtl.asnx?naram=wGEVXOwtDavaau2w%2bnF... 3/25/2019
ONEMOjetc.
APPENDIX
TABLE
1: ATTACHMENT REQUIREMENTS FOR WIND
DECK
UpuffREsisrANCE
APPLICATION
TYPE
DESCRIPTION
PAGE
1A
Wood
New or Reroof (Tea r-Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
1B
Wood
New or Reroof (Tea r-Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
IC
Wood
New, Reroof (Tear -Oft) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
SD
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
12
1E
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-14
SF
Wood
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
15-17
1G
Wood
New or Reroof (Tear -Off)
E
Non -I nsulated, Mech. Attached Base Sheet(nalls), Bonded Roof Cover
18-21
IH
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
21-25
11
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
26
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
27-29
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
30-34
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
35-37
3A
Structural concrete
New or Reroof (Tear -Oft)
A-1
Bonded Insulation, Bonded Roof Cover
38-46
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
46
4A
Lightweight concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47-49
4B
Lightweight concrete
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
50
4C
Lightweight concrete
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
51-53
SA
Cementitlous wood fiber
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
54
5B
Cementitlous wood fiber
New, Reroof (Tea r-Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
55
5C
Cementitlous wood fiber
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
56
SO
Cementitlous wood fiber
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
56
SE
Cementtious wood fiber
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
56
6A
Existing gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
57-59
68
Extstinggypsum
Reroof (Tear -Off) or Recover -
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
59
6C
Existing gypsum
Reroof (Tear-OfQ or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
60
6D
Existing gypsum
Reroof (Tear-OfQ or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
60
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
61-65'
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
65
The following notes apoly to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
D Wood: Minimum 0.75-Inch penetration.
➢Steel: Minimum 0.75-Inch penetration and engage the top Flute of the steel deck.
D Structural concrete: Minimum 1-inch embedment into pilot hole In accordance with fastener manufacturer's published installation instructions.
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL3654-RI3
Certificate of Authorization 832455 6'" EDITION (2017) FBC NON-HVH2 EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 65
NNEMO I etc.
3. Unless otherwise noted, insulation maybe anyone layer or combination of polyisocyanumte,polystyrene, wood fiberboard, periite,gypsum-based roof board or mineral -wool roof board that meets the CIA req uirements
of F.A.C. Rule 61G20-3 and Is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the mof cover.
4. Minimum 200 psi, minimum 2-Inch thick lightweight Insulating concrete maybe substituted for rigid Insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet
fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural
members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval
documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published Instructions.
➢ Hot asphalt (HA):
Full coverage at 25-30lbs/square.
D Dow INSTA STIK Cluik Set Insulation Adhesive(D-15):
Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
D Millennium One Step Foamable Adhesive(M-OSFA):
Continuous 0.25 to 0.5-Inch wide ribbons, 12-Inch o.c.
➢ Millennium PG-1 Pump Grade Adhesive (M-PG3):
Continuous 0.25 to 0.5-Inch wide ribbons, 12-Inch o.c
D OMG OlyBond S00(OB500):
Contlnuous0.75to1-inch wide ribbons, 12-inch o.c.(PaceCartor5pot5hot).Note. 01yBond6reen maybe used where O1yBond500 is referenced.
D OlyBond Classic (08 Classic):
Full coverage at 1 gal/square.
D ICP Adhesive& Sealants Polyset CR-20:
Continuous 25-3.54nch wide ribbons, 12-Inch o.c.
➢ Note. When multiple layers(s) of Insulation and/or coverboard are Installed In ribbon-appfied adhesive, board joints shall be staggered.
D Note: The maximum edge distance from the adhesive
ribbon to the edge of the insulation board sholf be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are Bat -stock or taper board of the minimum thickness noted. Tapered polyisocyanumte at the following thickness limitations maybe substituted with the following Maximum
Design Pressure (MOP) limitations. In no case shall these values be used to Increase' the MDP listings in the tables; rather If MDP listing below meets or exceeds that listed for a particular system in the tables, then the
thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA):
MDP -157.5 psf (Min. 0.5-Inch thick)
➢ Millennium PG-1 Pump Grade Adhesive (M-PGI):
MDP -157.5 psr (Min. 05-Inch thick)
D OMG OlyBond 500(OB500):
MDP -45.0 psi (Min. 05-Inch thick Multi -Max FA-3)
➢ OMG OlyBond 500(OB500):
MDP -287.5 psf (Min. 0.5-Inch thick ISO 95+GL)
D OMG OlyBond 500 (O6500):
MDP -315.0 psf (Min. OS -Inch thick ENRGY 3)
D OMG OlyBond 500 (OB500):
MDP -487.5 psf (Min. OS -Inch thick ACFoam II)
D ICP Adhesives& Sealants Polyset CR-20:
MDP -117.5 psf (Min. 1.04nch thick)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. Far mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined In accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention
Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully banded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined In accordance with FBC Chapter 16, and no rational analysis is permitted.
21. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof Installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the Insulation is optional;however, the existing roof system shall be suitable for a recover application.
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL3654-R23
Certificate of Authorization 032455 67" EDJTION (2017) FBC NON.HVHZ EVALUATION Revision 22: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 2 of 65
ONEMO I etc.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat
thickness is 2-Inches. For LWC over structural concrete, reference Is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWC references, listings were established through testing over lightweight concrete cast
using only foaming agent (ASTM C8961, water and Portland. cement (ASTM C150), with no proprietary additives, In accordance with procedures adopted by Miami -Dade BCCO (FBC CER3592). Unless otherwise noted,
use of these listings In new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15. Unless
nntnd —fp, r,. the
hnndpd hacp my ar ran chpat nnnliratinnc
,
PoLYGLAss F COVERS
REFERENCE
LAYER
MATERIAL
APPLICATION
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601,Type ll
Hot Asphalt at 20-40
(Base and Ply sheets,
Ply
One or more plies Polyglass Ply IV, PoIyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Ibs/square
Asphalt -Applied)
Note:
Asphalt-applledsheets or insulation shall not be applied topoly-lim surfacedmembmmes.
Base Ply
One ply Elastobase(sand/sand), Elastoflex V, Elastoflex S6, ElastoflexS6 Type 11, PoIyglass HT Base 650
PG350 at 1.5-2.0
SBS-CAI
Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 Type 11, Elastoflex 56 G, Elastaflex 56 G FR, Elastoshield TS-G, Elastoshield
Cap Ply
TS-G FR, Polyrresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
gal/square
Base Ply
One ply Elastobase sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6Type ll
polyplus 35 at 1.5-2.0
SBS-CA2
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex 56 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield
Cap Ply
TS-G FR, Polyfiresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
gal/square
One or more plies Elastobase(sand/sand or poly/sand), Elastobase P(sand/sand or poly/sand), ElastaflexV, Elastoflex 55, Elastoflex
SBS-AA
Base Ply or Ply
S6 Type II, Pol glass HT Base 650
HotAsphaltat 20.40
(585, Asphalt -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR,ElastoflexS6, Elastoflex S5 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshleld TS-G,
IbsJsquare
uare
Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko 65B5 FR (sand -backed)
" Note:
Asphalt-appliedsheets or Insulation shallnot beapplied to poly -film surfaced membranes.
or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastaflex V, Elastoflex 56, Elastoflex S6 Type II, PoIyglass HT Base
SBS-TA
Base Ply or Ply
6One 50
(SBS, Torch -Applied)
Elastoflex V, Elastoflex VG, Elastoflex VG FR, ElastoflexS6, Elastoflex 56 Type 11, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS-
Torch -Applied
Cap Ply
G, Elastoshield TS-G FR resko G 58S (poly -film backed), Pol resko G SBS FR (poly -film backed
Base PI
One or more plie Elastoflex SA V Base, lastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elas—tofli P FR, PoI reflect
Self-Adhering
(SBS, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substratesf"SBS-SA are limited to the SBS-SA Base Ply options hereln,
Elastobose(poJy/sand) orElastobose (poly/poly).
APP-CAl
Cap Ply
POW"G FR
PG350 at 1.5-2.0
gal/square
APP-TA
Base Ply or Ply
One or more PoIyglass APP Base, Polyflex, Po bond
Torch -Applied
(APP. Torch -Applied)
Cap Ply
Polyfle polyflex G Polyflex G FR, Pal bond, Polybond G, Polyfiresko G, Polyfiresko G FR
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfiresko G SA, PoI kool
APP SA
(APP, Self -Adhering)
Note:
Unless otherwise noted, Permissible membrane substmtesforAPP-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Etas tobase (poly/sand) or Elastobase (poly/poly).
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-RZ3
Certificate of Authorization 932455 6M EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 PoIyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 3 of 65
NNEMO I etc.
26. Vapor barrier options for use over structural concrete deck followed by adhered Insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MOP listings below vs. those In Table 3A
applies:
OPTION
#
PRIMER
VAPOR BARRIER OPTIONS; STRUCTURALCONCRETE�DECH; ADHERED
VAPORBARRIER
I NSUI.ATION PER TAeLE 3A
INSUlA71ON ADHESIVE
MOP (PSF)
TYPE
ATTACH
VB-1.
PG100
Elastoflex SA V Plus
Self -Adhering
Inta-Stik or CR-20, 12-inch D.C.
-60.0
VB-2.
PG300
Polyglass APP Base
Torch -applied
Inta-SLIk or CR-20,12-inch D.C.
-75.0
VB-3.
PG300
Elastoflex SAP
Self -Adhering
Insta-SLIk, 12-inch D.C.
-75.0
VB-4.
PG300
Elastoflex SAP
Self -Adhering
Millennium One Step Foamable Adhesive,12-Inch D.C.
-157.5
VB-5.
PG300
Elastoflex SAP
Self -Adhering
CR-20, 12-Inch D.C.
-270.0
VB-6.
PG300
Elastoflex SA V Base, Elastoflex SA V FR Base,
Elastoflex SA V Plus, Elastoflex SA V Plus FR
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-Inch D.C.
2900
17. The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for
application limitations and a Roofing Materials Directory for fire ratings associated with coating usage.
OPTIONSSURFACING
Option
Surfacing
Florida Product Approval
SURF-1.
PG300 Fibered Roof Coating
FL10291
SURF-2.
P6600 Non-Fibered Aluminum Roof Coating
FL10291
SURF-3.
PG650 Fibered Aluminum Roof Coating
FL10291
SURF-4.
PG700 High Quality Elastomeric Roof Coating
FL10291
SURFS.
PG700OS(Quick Set) High Quality Elastomeric Roof Coating
FL10291
5URF-6.
PGBOO Asphalt Emulsion Roof Coating
FL10291
SURF-7.
Polplus 60 Premium Non-Fibered Aluminum Roof Coating
FL10291
SURFS.
Polyplus 65 Premium Fibered Aluminum Roof Coating
FLSG291
SURF9.
Polybdte 70 Premium Grade Elastomeric Roof Coating
FL10291
SURF-10.
Pol brite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating
FL10291
SURF-11.
Polybrite 71 HS
FL20291
SURF-12.
Pol brite 90 High Solids Silicone RoofCoating
FL30291
SURF13.
Pol brlte 95 Silicone Roof Coating
FL10291
SURF-14.
KM AcrVf15
FL27409
SURF-15.
KM Acryl 15 QS
FL27409
SURF-16.
KM Acryl 25
FL27409
SURF-17.
KM Acryl 25 CIS
FL27409
SURF-18.
KM Acryl 40 HS
FL27409
SURF-19.
KM Acryl 85
FL27409
SURF20.
KM PS#250
FL27409
SURF-21.
KM PS#220
FL27409
28. 'MDP" =Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
NEMO ETC, LLC Evaluation Report 1)9290.02.08-R21 for FL3654-RZ3
Certlfiate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 65
NNEMOletc.
x.s s CONSTRUCTION •.. (TEAR -OFF)
SYSTEM TYPE F: s BONDED ROOF
System
tied (Note 1)
Pdmer
Roof Cover (Note 1S)
MOP (psf)
Joint Treatment
Base Ply
Ply
Cap Ply
No.
W170
Min. 15/32-
None
None
SBS-SA
(Optional)SBS-SA, SBS-
5BS-SA, APP-SA,-
A0.0
inch plywood
TA, APP-TA
TA, APP-TA
W-171
Min. 15/32-
(Optional) PG100
None
Polyflex SA Base
(Optional)APP-TA
APP-TA
-90.0
Inch plywood
W-172
Min. 15/32-
PG1OO
None
585-SA
(Optional)SBS-SA, SBS-
SBS-SA, APP-SA, 505-
-97.5
Inch plywood
TA, APP-TA
TA, APP-TA
Min. 15/32-
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, railed into
Elastoflex SA Base or
(Optional)SBS-SA, SBS-
SBS-SA, APP-SA, SBS•
W-373
inch plywood
(Optional)PG100
place to create continuous bond.
Elastoflex SA V FR Base
TA, APP-TA
TA, APP-TA
-97.5
W-174
Min. 15/32-
POLYBRITE 745
None
SB5-SA
(Optional)SBS-SA, SBS-
SBS-SA,APP-SA,SBS-
-105.0
Inch plywood
TA, APP-TA
TA, APP-TA
Min. IS/32-
Plywood joints are covered with 4-Inch wide strips of Elastoflex SAV Plus, rolled Into
Elastoflex SA Plus or
(Optional)SBS-SA, SBS-
SBS-SA,APP-SA,5BS-
W-175
inch plywood
(Optional)PGI00
place to create continuous bond.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA
-135.0
W-176
Min
(Optional)PGI00
d joints are coveredwith4-Inchwide strips of ElastoflexSA V Plus, rolled into
Plywood
Polyflex SA Base
(Optional)APP-TA
APP-TA
-135.0
plywood
create continuous
NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-R23
Certificate of Authorization d32455 6- EDITION (2017) FBC NON-HVH2 EVALUATION Revision 21: 10/08/2018
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems;(954) 233-1330 Appendix 1, Page 26 of 65