HomeMy WebLinkAboutPOOL PLANSVSFHP165 PERFORMANCE CURVES 100 WATERLINE BASIN O 90 LL (a FILTRATION PUMP O F 70 Lu LIJ I.L. 00 M50 RPM Q SO w = 40 V_ 30 2750 RPM Q Iwo RPM } 20 1730 RPM J 10 Q ~ 0 t- 0 10 20 M 40 m 60 70 M 30 100 110 IM in 140 IN 160 In IN 1M 2N FLOW GPM 'IS" MIN. (NO SCALE) *ENTIRE PERIMETER BOND WIRE WIAPPR. CLAMPS (ONE ON EACH SIDE OFPOOL4TOTAL) PER N.E.C. 2014 SEC. 680.26 (WHERE ADOPTED) I so1L 8 GAUGE SOLID COPPER WIRE I TT]I 1 MINIMUM 18" FROM EDGE OF POOL AROUND ENTIRE POOL PERIMETER BURIED 4" TO 6" DEEP MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT AREA WHERE DECK RAISED •8" ABOVE POOL #8 GROUND WIRE T ��iiHA �4WHER BONDING DETAIL 72" MAX LWHERE APPLICABLE u 48" MAX PER NATIOW L ELEC7PoCAL CODE WATE EPTH 111(r MIN. a STEP DETAIL 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT a • IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUMTE 4000 PSI. STEP DETAIL (NO SCALE) N.T.S. POOL RETURN LINES 2" TO FIRST TEE POOL DETAIL APPROVED MAIN DRAIN FRAMES AND GRATES PER V.C.B. ASME/ANSI 112.19.8-2007 • .• APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL WITH THE 2017 SUPPLEMENTS AND THE • ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE MINIMUM (2) SUCTION LINES PER PUMP 3 FT. SEPARATION OR SEPARATE PLANES ° e 3 FT. MIN. • e e ° 2.6" SUCTION LINE TO PUMP MAX 117 G.P.M. 6�MAX TO FILTRATION PUMP 3" PLUMBING LINES FROM SUMP WI 3" TEE GRADE 1.V OVERFLOW 24- TO FRENCH DRAIN ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. IS ASSUMED FOR THIS DESGN. NOTE; CLEAN FILL COMPACTED TO 95% MAX. DRY DENSITY UNDER DECK ONLY OVERPOUR BEND INTO DECK N=REMOVE GRATES (ORCAP TILE, @48"O.C. MAX. WELL POINT P CH AUX M MAIN WHERE DRAIN 8 ATTACH AUX. PUMP pppOCABLE �' LINE WHEN EMPTYING POOL 6"X6" TILE 4" SLAB INTERIOR 2500 FIRE GRATE SHALL FINISH TYPICAL WALL BE SECURED IN 4 /2 TYP. SECTION 8t PLACE SO WALL WELL POINT THAT TOOLS (NO SCALE) ARE REQUIRED FOR REMOVAL STEEL-TEX FORM 6" TYP. R KRAFT WALL FLOOR #3 @ 12" O.C.B.W. THREAD E NOTE: FOR DEPTHS PLUG REATER THAN 6' ADD 1- #3 COVE BAR @ 6" O.C. TO PUMP -► GRAVEL BED NO ScALE FOOTER DETAIL (2) #3 REBAR OR (1) #5 REBAR 81. o0 8" REBAR MIN. 2%" CONCRETE COVERAGE NO SCALE SWIM_OU_TS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE APPROVED WITH FBC 2014WATEERRLINE I 20" max. 18"-1 2" RETURN TO 16T TEE W� a a D.' W °60 O_, 8 = N F U 0i apW z a=Q. U L7 =_W ap cy J ain in 0FX W O0 a r, N.T.S. 7 4= M 1.5" SCN 40� 18" SAFETY BARRIER PER FRC 4501.17-4501.17.1.15 & ASTM5034-95, ASTM D3787-89, ASTM 653-96 & R4501.17.1 THRU R4.501.17.3 POOL BARRIER PER FRC 450'1.17-41.1.17.3 AND ANSI/NSPI-5-1995 BABY BARRIER FENCE PER PLAN AND SCREEN ENCLOSURE (SEP. PERMIT) 2" LOOP 4� 2.5" SCH 40------ POOL DEEP 3" SCH 40 ' (2) 8" DIA. MAIN DRAINS TIED TOGETHER - 36" APART N (DRAINS TO BE COMPLIANT WI ASMEIANSI 145 GPM @ 2.8 FPS THRU EACH GRATE LED LIGHT I SKIMMER 3X4 PAD POOLBOND PB-2008 DECK WATER 2" SCH m Vac 1"SCH 40 Z' SCH 40 49 ft. DANDY DECK JET (TYP OF 3) 1.5" SCH 40-® OVERPOOR COPING I <' R- x u a 3 FT DEEP FLO-KRETE A 48" HIGH APPROVED BABY FENCE DECO -DRAIN EXACT PLACEMENT OF DECO DRAIN TO BE DETERMINED IN FIELD. BONDING WIRE TO GRID LOCATION OF WATER BOND LOCATE IN -FIELD MUST HOLD 35 PSI FOR AT LEAST 30 MIN. . SCHEMATIC (NO SCALE) FILTER (2) MAIN DRAIN MIN. Y APART PUMP HAIR & LINT CA rCHER (COMPONENT OF I DEIMO EXISTING PAVERIHAUL FLO-KRETE ELECTRICAL DIAGRAM AND NOTE: POOL PUMP MOTOR LOCATED ABOVE GFI OUTLET PER 2014 NEC GRADE. PROVIDE SEPARATE CIRCUIT FOR PUMP MOTOR(SAND HEATER(S) ETC (NO SCALE) NOTE: INSTALL 126V 15 RAIN nsxT ouT000R LECTRICAL PANEL AMP WEATHERPROOF (SIZED PER LOAD) DUPLEX RECEPTACLE AT TO MAIN SERVICE PANEL IN G.F.I LEAST 10' AWAY AND APPROVED NDUIT(S�D ouTLEr NOT MORE THAN 20' PER LOAD) .moon THE INSIDE WALL WIRING TO POOL L'ONT IN TIME-C KFROM OF THE POOL APPROVED CONDUIT PUMP MOTOR UL APPROVED DECK BOX FOR DIRECT CONINE NOTES: TO WET NICHE (1) POOL PANEL AND SWITCHES MUST BE AT LEAST 6 FROM THE INSIDE WALL OF THE POOL • (2) ALL ELECTRICAL WIRING AND EQUIPMENT POOL LI HT SWITCH* MUST INSTALLED IN ACCORDANCE WITH THE UNDERWATER EITHER INDOOR OR 2014 EDITION OF THE NATIONAL ELECTRICAL LIGHT OUTDOOR CODE APPROVED WIRING IN i" (3) PROVIDE PROPER WORKING CLEARANCE SCH 40 PVC W/ aSPACES BONDING CONDUCTOR SPACESFOR ELECTRICAL EQUIPMENT AS PER OF NFPA 70 Ill"""IWE HAVE REVIEWED THE POOLISPA PLAN AND APPROVE ALL ELEVATIONS, DEPTHS, AND DIMENSIONS TO BE CORRECT UNLESS OTHER WISE NOTED ON PLAN. • APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 61.h ED. POOL DECK TO HAVE SCREEN ENCLOSURE. SEPARATE PERMIT PIONEER SCREENS GENERAL NOTES 1. SWIMMING POOL CONSTRUCTION TO COMPLY Wl FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN -PLACE CONCRETE WI MINIMUM 3,000 P.S.I. CONCRETE 1@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2.600 P.S.F. HAS BEEN USED IN THE DESIGN. L REINFORCING BARS SHALL BE NEW BILLET, GRADE M. S. ALL POOL PIPING TO BE P.V.C. SCHEDULE 4I MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK -WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR S. WATER SUPPLY S DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM. 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 10. HAIR S LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN WI A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. IT. ELECTRICAL: INSTALL WIRING S DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES S HOUSING, METAL PARTS OF LADDERS, HANDRAILS, DMNG BOARDS S SUPPORTS TO BE BONDED TOGETHER S GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN M8 COPPER. 11 NO OVERHEAD OPEN WIRE OVER POOL WATER. 10. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M.I S.F. OF FILTER AREA. NO BACK -WASH REQUIRED. 3X4 15 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT PAD SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.SL. COMPANY. 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO rREcEl\/ED ENT UNDER 3 0 °01r9up PermltN�9 ANSI-15 REC. PUMP = 1.65HP JANDY VARIABLE FLOPRO VARIABLE SPEED LOW SPEED - 36 GPM MAX HIGH SPEED = 98 GPM @ 20 TDH 2.5" SUCTION PIPE @ 98 GPM = 7.48 FT/SEC. 18 FT./SEC. MAX. -SUCTION LINES) 3" BRANCH PIPE @ 49 GPM = 3.44 FT./SEC. (6 FT./SEC. MAX. - PRESSURE LINES) 2" PRESSURE PIPE @ 98 GPM = 7.48 FT./SEC. (10 FT.ISEC. MAX. - PRESSURE LINES) 200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM BACKWASH VALVE NO COPING SAVI NICHELESS 4" MIN. LED LIGHT NO NICHE 1" LIGHT CONDUIT UNDERWATER UNDERWATEF LIGHT SP 10-22 WALL FITTING LIGHT DETAIL INSIDE PIPE (NO SCALE) 1.5" SCH 40 PVC SLEEVE POOL FINISH (NO SCALE) CEFtTIFICATION OF COMPLIANCE i•, 1 r • r.r - WN•rnw. 640.231XY pempaw. Rama A„li•YartrXseAtlan Oetlrt O vs 8" a•.,K, nA31a as®IAIp: ss O.r1w Am: 1006PM wArw.w" "GPM W"NMmoNaure. DEC 10 2008 This paauel has ken INN M ANSVMME 112198W (aaawkum Aa-M) W§10al ul the Viginla Galram Porn 1" 1098) Pool am Spa salel9'Aa fATha kr. llnh•rarirmlahwaraaa. Ino, 2925E im,M I With",bWre 10s, Rua, (A 92821O19 This predNl is (em&tl a amp12 Nlh 4141140 the MrylnM Graham take, NG13M1) Nal am SP SaIM Mt. A M Mihelnl rewhsla Iss ahax ma M larM M ww ."vwry hsmmcasswp iowww.hl llih pusim h mmn6nu"a h9Yaerwry Plat Whr (A MIN ])RFan SPogir IhN.Ova.(A 93PY519Pa.M1 �.,,, uxrwaier'nry:lnv'Fv nn wx wa5v� reiwaryYv atrTn .�.mm OVERPWR BEND INTO DECK NOTE: REMOVE GRATES (OR CAP TILE, @ 48" O.C. MAX. WELLPOINTPLUGFRX.sam WHERE DRAINS ATTACH YING PUMP PUMP APPLICABLE DNE WHEN EMPTYING POOL 6"X6" TILE - ec. i 4" SLAB INTERIOR 2500 FIBE GRATE SHALL FINISH TYPICAL WALL BE SECURED IN 4 /2' TYP. SECTION & PLACE SO WALL WELL POINT THAT TOOLS ARE REQUIRED No SCALE) FOR REMOVAL STEEL-TEX FORM 6" TYR R KRAFT WALL FLOOR #3 @ 12" Q.C.B.W. THREADE NOTE: FOR DEPTHS PLUG REATER THAN 6' ADD 1- #3 COVE BAR @ 6" O.C. TO PUMP -► GRAVEL BED (NO SCALE) 'IF4 MAX. WIDTH 13 MAX. LENGTH 26' MIN. DEPTH 3' MAX. DEPTH S. SHAPE CUST ELEVATION T.B.D FILL FROM EXCAVATION: HAUL TILE: INCLUDED INTERIOR FINISH: GEM FINISH POOL PUMP: 1.65 VS FHPM wm+AMsvapsvnc�la w1+ JA DY "AQUA -PURE" T SYS EM DECK DRAIN INC GALLON CAPACITY -POOL 10,053 GAL. TURN -OVER RATE 6 hrs TERMITE TREAT INC BARRIER INC MAX. WATER VELOCITY - 6 ff./s FROM TRUNK LINES TO 8 RJs SUCTION LINES 10f13s MAX RETURN LINE SKIMMER MIN. FLOW 25 GPM SURFACE AREA OF POOL - 338 $Q. FT. 78' A. ALLEN ENGINEERING LLC, CA NO. 33042 2367 7TH STREET, LA VERNE CA, 91750 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AARON H. ALLEN PE, FL. REG NO.86620 FL. JOB NAME: DARLING ADDRESS: 3300 BENT PINE DRIVE FT. PIERCE, FL. PERMIT NO.: _ DATE DRAWN: JULY 9, 2019 CHECKED BY: AARON H. ALLEN DESIGNER APPROVAL: CUSTOMER APPROVAL: SCALE: 1/4" = V G SCANNED Rff St. Luce County CONCRETE POOLS, INC. 1 ROW OF WATERLINE 3 'R ' R STEEL @ 12" O/C E.W. FLOOR SLOPE FLOOR SLOPES SHIALL-K REASONABLY UNIFORM AND COMPLY VATH ARTICLES S.6 7 THRU 883 22' :4DRAI CYCO:LAC 26' TYPICAL SECTION THRU POOL (NO SCALE) e w WALLS SHALL NOT SLOPE GREATER THE" • CILE COPY REVIEWED FOR CODE COMPLIANCE T. LUCIE COUNTY BOCC