Loading...
HomeMy WebLinkAboutPLANSNOTE: FINAL YARD GRADES TO BE FLUSH WITH EDGE OF POOL DECK (OR POOL WHERE NO DECK IS PROVIDED) AND TO SLOPE AWAY FROM POOL/DECK AT 1':12' MAX. FOR FIRST 6' FROM EDGE. POOL EQUIP. SEE SITE PLAN: BY OTHERS REINFORCED OR PRODUCT APPROVED CONCRETE SLAB(S) (FIELD VERIFY SIZE & LOCATION) AUTO -FILL DEVICE 1/2" FRESHWATER SUPPLY LINE - FROM EX. HOSE BIBB - BY OTHERS FIELD VERIFY H.B. LOC. & 2" OVERFLOW LINE TO ON -SITE DRAINAGE SYSTEM PROVIDE WINDOW AND DOOR ALARMS ON ALL OPENINGS THAT LEAD ONTO POOL AREA PER FBC SIXTH EDITION, 2017 EXIST. RESIDENCE POOL LAYOUT & PIPING PLAN SCALE: 1/4"=V-0" LE COPY REV IWED FOR CODE C MPLIANCE ST. LUCIkCOUNTY BO C I W� U U J U 7 � a U � ^o co co :2 cc° =.��W M �C � CC•Q :2;� �y •' Z w ek C.J w r 1. V O a M V7 V1 � W 00 O ooaa ^, V/ A O w � w A U � H C� 0 *, �. �y O U O O BY: BY: 9 : ED ER: 3 IF 2 CONTROL JOINTS REQUIRED: SAW CUT I" DEEP WITHIN 4 TO 6 HOURS OF DECK PLACEMENT AT 12'-0" MAX. SPACING. 4" THICK CONC. DECK W/ 6" X 6" CONCRETE - 10/10 WIRE MESH OR FIBER MESH CONC. OVERPOUR COPING SLOPE DECK(.) %" MAX. PER. FOOT 3" - I -1'r-.CLEAN FILL COMPACTED TO of - 95 % MAX. DRY DENSITY UNDER DECK ONLY gug II 2-#3 DIA. REBAR TOP OF BEAM r 5- "33 MAROR REINFORCING STEEL EQUAL #3 DIA. REBAR (v 12" O.C.E.W, WALLS &FLOOR 6„ RADdIUS _ I� 1- VARIES TYPICAL WALL SECTION _® 14" s� m� P '� IPE REDUCED TO 1" �` u AND RUN TO DECK e 3 / BOX 2"SCH 40PVC CORD LED LIGHT SLEEVE SP 16-2E WALL FITTING - OR EQUAL INSTALLED INSIDE PIPE LED LIGHT DETAIL 211 GRADE LOT TO SLOPE AWAY FROM POOL DECK Q„ 2500 PSI CONC. W/ 6" X 6" - 10/10 W.M. OR 2500 PSI FIBER MESH CONC. -+ 8" X 12" MONO 12" FOOTING W! 3 - #3 DIA. OR 2 - #4 DIA. OR 1 - #5 DIA. THICKENED EDGE DETAIL (WHEN APPLICABLE) NOTE: ALL CONTROL JOINTS WITH IN BONDING GRID AREA TO BE FILL W/ ULTRAVIOLET RESISTANT SILICON CAULK 18" MIN: 24" MAX. (ENTIRE PERIMETER) W.L. b i 4„ _ 6„ #8 SOLID COPPER BOND _ BELOW WRE W/ APPR. CLAMPS DINE ON EA SIDE HF SUB -GRADE POOL-4TOTAL) 4" THICK x Y W IDE 2500 P.S.L CONCRETE SLAB W/(1) #8 BARE COPPER WIRE (UNDERSLAB) BONDED TO POOL STEEL AS SHOWN EQUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTATION OF N.E.C. 2014 SEC. 680.26 WATER LINE VACUUM FITTING W/ SELF -CLOSING SAFTY COVER (HAYWARD MODEL #400) VACUUM LINE DETAIL I/ I #3 DIA. REBAR A 6" O.C.E.W. IN SUN SHELF AREA COMPACTED CLEAN FILL 10.5" SUN SHELF SECTION SCALE: 1/4" = V-0" 10.5'1, 10.51, -� 4n en BENCH SECTION 12", 12" M 6" aIM&you I101"L r CLEAN COMPACTED SOIL #3 DIA. REBAR @ 6" O.C.E.W. IN SUN SHELF/STEP AREA I4" MIN. SKIMMER COVER W/ './ WRAP(2)#3 DIA. AROUND ADJUSTABLE COLLAR --/// SKIMMER, TIED TO POOL STEEL WATER LINE LEAF BASKET .'+ TOPOOLPUMP 25 GPM MIN. FLOW y;. EQUALIZER LINE WHEN REQUIRED SKIMMER DETAIL IN 28' 19, 51 3+ 9.5' SLOPE 1' POOL SECTIOht TYPE 'O' POOL 5' POOL PANEL W/ 30 AMP (100%RATED) 2-POLE BREAKER (3) - #10 &(D #12 GROUND m. THHN CU IN 1/2" RPVC S.P.S.T. TOGGLE CONDUIT SWITCH (2) LED POOL LIGHTS (GFI NOT REQUIRED) POOL SYSTEM FLOW RATE: 120 GPM (MAXIMUM FLOW FROM PUMP CURVE) REC. PUMP =1.5 HP JANDY FLO PRO FHPM DUAL SPEED - LOW SPEED = 36 GPM MAX. HIGH SPEED = 120 GPM @ 25 TDH 3" SUCTION PIPE @ 120 GPM = 5.29 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.5" BRANCH PIPE @ 60 GPM = 4.10 FT./SEC. (6 FT./SEC. MAX. - SUCTION LINES) 2.5" PRESSURE PIPE @ 120 GPM = 8.20 FT./SEC. (10 FT./SEC. MAX. - PRESSURE LINES) CARTRIDGE FILTER = 120 GPM @ 1 GPM/ SQ. FT. = 120 SQ. FT. MIN. FILTER AREA MANUAL MOTOR STARTER SWITCH 1.5 HP REC. PUMP MOTOR w/ BUILT-IN OVERLOAD SWITCH W/ 3 - #10 THHN CU WITHIN 12" MIN. CONDUIT (CONNECT TOP 20 AMP -2 POLE GFCI BREAKER) IME CLOCK W. P. DISCONNECT --12 VOLT TRANSFORMER JUNCTION BOX 1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION. 2. 3412 THHN CU WITHIN 1/2" MIN.. CONDUIT FOR POOL LIGHT(S). 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. W/ #8 SOLID, BARE COPPER. 4. PROVIDE W.P.G.F.I. OUTLET 10' MIN..-20' MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(11} 6. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL - BY OTHERS. ELECTRICAL DIAGRAM AQUASTAR 32CDFL - 32" - CHANNEL DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE SINGLE UNBLOCKABLE OR EQUAL FINISH PLASTER HYDROSTATIC RELIEF VALVE PERFORATED PVC COLLECTIO TUBE, WHERE REQUIRED N.T.S. 1- 2„ ��HkeYD-R-OSTATIC RELIEF VALVE PORT OR CAP OFF 3 GENERAL NOTES: M 1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE GROUNDED PER CODE, 2. POOL TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM COMPRESSIVE STRENGTH OF 4000 P.S.I. AT 28 DAYS. 3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OF NEW BILLET STEEL, CONFORMING TO ASTM A-615, GRADE 60, STEEL SHALL BE BENT, MIN. 40 DIA. LAP SPLICE AND PLACED IN ACCORDANCE WITH ACI STANDARDS. PROVIDE 3" MIN. CONCRETE COVER OVER REINFORCING STEEL.. 4. GRATE IN MAIN DRAIN SHALL HAVE A FREE AREA OF 4 TIMES THE AREA OF THE SUCTION LINE. 5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER. 6. POOL TO BE FENCED PER LOCAL CODES. - 7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE. x( 4 8. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSI/ NSPI 5; ANSI/ NSPI 6; AND ANSI/APSP 7 2006 AND ANSI/APSP.ICC-15 2011. 9. SPAS AND HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A COVER DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN OPERATING SEASON ARE EXEMPT FROM THIS REQUIREMENT. 10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH THE FBC SIXTH EDITION (2017) - RESIDENTIAL -PRIVATE SWIMMING POOL AND LOCAL AMENDMENTS, IF ANY. 11. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC SIXTH EDITION (2017) - RESIDENTIAL CHAPTER 45 - PRIVATE SWIMMING POOL. 12. PRESUMPTIVE LOAD- BEARING VALUE OF SOIL -IN ACCORDANCE WITH FBC s� SIXTH EDITION (2017) SECTION 1806.2 THE SOIL BEARING VALUE SHALL BE A MINIMUM OF 2000 P.S.F. (FOLLOW GEOTECHNICAL ENGINEERING REPORT RECOMMENDATIONS OR INDUSTRY ACCEPTED STANDARDS - BY OTHERS) -13 SHOULD ANY MUCK 1 1 FLOOR 1� ARC, OR OTHER ORGANIC SOILS BE DISCOVERED ON -- -- EXCAVATION, THEY SHOULD BE REMOV ED IN THEIR ENTIRETY, ALL CONSTRUCTION SHALL STOP AND THE ENGINEER OF RECORD SHALL BE MAIN DRAW SUCTION LINE CONTACTED TO CONDUCT AN INSPECTION. 4 ABOVETIED -GEE ER SIZE PER TH 14. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS, N ABOVE -PIPE SIZE PER PLAN POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION. _ *. (CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR) MIN. Y2 YARD GRAVEL SUMP 15 POOL PLANS ARE DESIGNED TO MEE THE FBC FIFTH EDITION 2014 NOTE: 25.9 SQUARE INCH OPEN AREA, WRAPPED W/ DRAIN FEILD T ( ) 316 GPM = 3.9 FEET PER SECOND CLOTH (RECOMMENDED) RESIDENTIAL - PRIVATE SWIMMING POOLS. 16. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ANS►/APSP 7-2006 AND FBC SIXTH Channel Main Drain Detail ' EDITION (2017) - RESIDENTIAL CHAPTER 45. SCALE: 3/8" = r-o" PLUMBING NOTES: 1. ALL PIPING, EQUIPMENT AND MATERIALS USED IN THE PLUMBING SYSTEM OF SWIMMING POOLS THAT ARE BUILT IN PLACE SHALL CONFORM TO THE FBC SIXTH EDITION (2017), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING POOLS. 2. POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT PUMP FRAME OR FILTER EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES TANK MOUNT `' - AND 10 FT/SEC. PRESSURE LINES. 3. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE ANCHOR POOL PUMP AND �+ - "`"' FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE FILTER PER MFGR'S. N.O.A. SLABS SHALL BE SET IN A PIT HAVING AT LEAST A DIMENSION OF FIVE 4" THICK REINFORCED DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A CONCRETE SLAB SUITABLE COVER. ALL VALVES SHALL BE LOCATED WHERE THEY WILL BE 2" MIN -.- "A READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL. F.G. 4. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR PUMP VERTICAL CHECK PATTERN. 5. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BV-PASS FILTER OR ANTI -SIPHON DEVICE INSTALLED TO PROVIDE A POSITIVE. MEANS OF e RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION. 6. _ ALL POOL PIPING SHALL BE L5" SCH. 40 PVC EXCEPT AS SHOWN AND SHALL BEAR THE H.S.P. SEAL OF APPROVAL. POOL PUMP AND FILTER 7. THIS POOL/SPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES ANCHOR POINTS MAY VARY WHEN EMPTY, FOR WATER TABLE LIP TO Y-0" BELOW POOL/SPA DECK ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE POOL EQUIPMENT ANCHORING DETAIL ELEVATIONS, ALL POOL/SPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF SEE MFGR. SPECIFICATIONS FOR ANCHORING VALVE. INFORMATION - EQUIPMENT SHAPES MAY VARY 8. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL. 9. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER SUPPLY WHICH IN THE JUDGEMENT OF THE ADMINISTRATIVE AUTHORITY MAY BE USED TO FILL THE POOL IF EQUIPPED WITH BACKFLOW PROTECTION. ONO OVER -THE -RIM FILL SPOUT WILL BE ACCEPTED UNLESS LOCATED UNDER B A DIVING BOARD, OR PROPERLY GUARDED. C 10. ALL POOLISPA PIPING SHALL BE INSPECTED AND APPROVED BEFORE COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, CINDER A STATIC WATER TEST OR AIR PRESSURE TEST OF NOT LESS THAN 35 PSI FOR 15 Q MINUTES. h 11. JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FLORIDA E BUILDING CODE, PLUMBING. 12. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR D UNION CONNECTION ADJACENT TO THE HEATER. 13. PURPLE PRIMER REQUIRED ON ALL PVC PIPING PER FBC SIXTH EDITION (2017). 14. GAS PIPING SHALL COMPLY WITH FLORIDA BUILDING CODE FUEL GAS. (SEPARATE PLANS AND PERMIT REQUIRED) 15. SWIMMING POOL/SPA WATER HEATERS SHALL BEAR THE LABEL OF A 4 O3 2 1 RECOGNIZED TESTING AGENCY. 16. PROVIDE BACK FLOW PREVENTOR ON WATER SUPPLY. EQUIPMENT LAYOUT SCALE: N.T.S. LEGEND 1. 2" VACUUM LINE 2. 3" POOL MAIN DRAIN LINE 3. 2" SKIMMER LINE 4. 2.5" POOL RETURN LINE A. 1.5" TO WASTE OR DISCHARGE TO GROUND B. 1.5 HP REC. PUMP W/ APPROVED HAIR & LINT STRAINER C. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE D. INSTALL PERMA-CAST PB-2011 WATER BOND OR APPROVED EQUAL TIED TO PUMP GROUND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA EXPOSED TO WATER) PER MFGR'S SPECS (FIELD VERIFY LOCATION) E. VALVES (TYPICAL) REVIEWED F0P" CODE COMPLIAa POOL SPECIFICATIONS ST. LUCIE COD" BOCC SIZE: 2114" X 28'-0" DEPTH: Y-0" TO V-0" VOLUME: 12,300 GALLONS ELEVATION: DET. ON SITE TURN OVER RATE: 5.7 HR. (a, 36 GPM MAX. - LOW SPEED (TURN OVER RATE: 1.7 HR. (i� 120 GPM - HIGH SPEED) DESIGN FLOW RATE = 12,300 CAL./6 HRS./60 MIN. = 34 G.P.M. TILE: STANDARD POOL FINISH: MARCITE OR EQUAL PIPING: SCH. 40 INLETS: POOL (3) DECK:4" CONC. W/ 61IX6" 10/10 W.M. OR FIBER MESH ELECTRIC: BY OTHERS POOL LIGHT: (2) LED - NICHELESS LADDER: NO HANDRAIL: NO REC. PUMP: 1.5 HP JANDY FLO PRO FHPM1.5-2 A.P.S.P. PUMP CERT.: CURVE A - 29 GPM *� 1725 RPM FILTER: JANDY CS150 CARTRIDGE 150 SQ. FT. FILTER AREA HEATER:NO VACUUM LINE: YES POOL AREA: 411 S.F. PERIMETER 91 L.F. AUTO -FILL: YES OVERFLOW: YES CHLORINE GENERATOR: NO POOL CONTROLLER SYSTEM: NO PI W 00 q i. co Lu 10 O O Q m v' o i . �C:coZ 1,11111111110 �J M 00 I` ~ E-4 en M 00 kn l- W F i H U 00 Q o U en N 00 P60 p.4 r� V O ^ ►4 w W C Vl C r 0 •