HomeMy WebLinkAboutEVALUATION REPORTr, CREEK �I Certificate of Authorization bur 29824 FLI11F••1'1 FILE COI dpa, F h Drive mpa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, hie EDITION (2017) Manufacturer: TAMKO BUILDING PRQDUCTS, INC. Issued October 19, 2017 P.O. Box1404 TcPN "4 iq0(-D3a � CONCEALED FASTENERS OR ATTACHME�7T3oplin, M064802 T, UCIE COUNTY BUILDING DI ARE THE RESPOhISIBILTfYOFTHE (417)624-6644 REVIEWED FOR COMPLIANCC _CON`fRACTOR OR RECORD htto:/Miww.tamko.com PrUMA10n o., Y/,G//O�%� / Quality Assurance: SCOPE UL LLC (QUA9625) SITE OR NO Category: Roofing REQUIRED BY FIELD INSPECTORS THAT �G�tltlld6 Subcategory: Undedayments MAY BE NECESSARY IN ORDER TO SCANNED NE Code Sections: 1607.1.1 COMPLY WITH ALL APPLICABLE CODES. �� Properties: Physical properties St. Lucie Comb/ PRODUCT DESCRIPTION TAMKOV ASTM Slate Surfaced Roll Roofing TAMKO® ASTM Tile Underlayment TAMKOO Master Smooth TAMKO® Moisture Guard® TAMKO@ No. IS ASTM Asphalt Saturated Organic Felt TAMKOV No.15 UL Asphalt Saturated Organic Felt TAMKO&Wo 30 ASTM, . ,- e, Asphaltiatura(gd,�S: Orgahie Feld; TAMKOO No. 30 UL Asphalt Saturated Organic Felt ASTM D 6380, Class M, Type It underlayment constructed from organic felt saturated with asphalt and coated on both sides with asphalt and surfaced with granules. ASTM D 6380, Class M, Type II underlayment constructed from an organic felt saturated with asphalt then coated on both sides with asphalt and surfaced with granules. ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ only. Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is saturated with asphalt. ,ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is saturated with asphalt. ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is saturated with asphalt. ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is saturated with asphalt. TAMKO® TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKO®TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. TBP14001.4 FL12328-R8 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK 7AMKOBUILDING PRODCUTS,INC. TAMKO Undedayments TECHNICAL SERVICES, LLC TAMKO® TAM -FELT Altemate to ASTM D 226, Type I and Type II undedayment constructed from a non - perforated organic felt that is saturated with asphalt APPLICATION METHOD Installation shall be in accordance with the published manufacturers installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. Al fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 118" gap at abutting joints. The minimum application temperature shall be 50OF except as follows: a) The minimum application temperature of TAMKOV TW Metal and Tile Underlayment and TAMKO® TW Underlayment shall be 40°F. b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35°F. The minimum roof slope shall be in accordance With FBC requirements except as follows: a) The minimum slope of TAMKO® ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturers recommendations, but in no case shall exposure exceed 30 days. Exception: TAMKO® TW Metal and Tile Underlayment may be exposed for a maximum 90 days. Self -adhering underiayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. All roof coverings shall be mechanically fastened through the undedayment to the roof deck. Allowable Roof Coverinas: Metal Roof Mineral Wood Panels and Surfaced Roil ,.. Shingles and Slate - Clay and Underlayment Underla ent Shln les Shingles Roofirm Shakes Shingles Concrete Tile TAMKO® ASTM Slate Y1 N N N N Y Surfaced Roll Roofing TAMKO® ASTM Tile N N N N N Y Underlayment TAMKOV Master Smooth Y1 N N N N N TAMKO® Moisture Guard® Y N N N N N TAMKO@ No.15 ASTM Asphalt Saturated Organic Y Y Y Y2 N N Felt TAMKO0 No.15 UL Asphalt Y Y Y Y' Y N Saturated Organio,Felt,. SAMKO�No: 30�ASTM��:xj :'Aspfialt Saturated_Organic Y Y Y Y Y Y Felt.:- TAMKOS No. 30 UL Asphalt Y Y Y N Y N Saturated Organic Felt TAMKO®TWMetal and Tile Y Y N N N Y Underlayment TAMKOBTWUnderlayment Y Y N N N N TAMKOOTAM-FELT Y N N N N N Notes: 1) Open valley applications per 1507.2.9.2 2) Wood shingles only FL12328-R8 2of4 Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at -the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The undedayment may be used as described in other current FBC product approval documents. B) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underayment. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (fST6049) TAP-214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP-215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP-217-02-01REV ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP-222-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies (TST6049) TAP311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies (TST6049) TAP387-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP388-02-01 ASTM D 1970 2015a ULLLC (rST9628) 13CA12269 ASTM D 226 2009 TBP14001.4 12328-RB This evaluation report is provided for State of Honda product approval under Rule bluzua. i ne manufacturer snap nouryummcn Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICEsr LLC COMPLIANCE STATEMENT TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. - No-74021 13 STATE OF 74U ONA. rc C�%% CERTIFICATION OF INDEPENDENCE 2017.10.19 12:15:58 -0`tt00r Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor w1I it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest. P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product END OF REPORT TBP14001.4 FL12328-RB Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i �k Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 26 Ga. GulfRibTm Roof Panel over 15132" Plywood Florida Product Approval #11651.22 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 —D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 SCANNED BY St. Lucl C®unh, Qp GENE IV (iy • '�,\S�:.2 No. 7551.9 = STATE OF • L Z Si'c4ORIDP �1�.� 'S�ONAL EN� '' n "`10/061201' Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: GulfRibTm, 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/a" Major Rib at 9" O.C. Panel Fastener: #9-15x1.5" HWH with sealing washing or approved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15&" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Design Uplift Pressures: Table "A" Maximum To[al UplrfttD ignaPiessure , 669 25 psf ,a 59 25tpsf Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" . ;aste�ner Pattern SIY &L66VXWM24" O C7ZO C Design Pressure includes a Safety Factor = 2.0. ow Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL# 11651.22 R3 • OCTOBER S. 2017 -ENGINEER -LOAD TABLE: 26-G-a GulfRibTM Panel over 15/32" Plywood - - --- - - Bulldings having,a Roof M angHez ght s 20"�O Roo"P Slope 2 /ty2 12 %12 G bl o Hip R of�Wln" e ed5�120- 180mph ;,Ezposure,C RlsktCafegorysll Endo_sediBuilding base taQ Flonda Building Code 20�1)7 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN. 114- Penetration) MIN. 15/32• ( ) ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING i ZONE 1 { a#9 15x1 5." Plywood 24', TYPE 1 24";, TYPE 1 24", LiY,PE i 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 ZONE 2 #9-15x1.5" Plywood 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 2 ZONE Fi)9 15x I.5" PIyM/ood 24", TYPE 1 24", TYPE 1 24", TYPE 1 13", TYPE 2 12", TYPE 2 12", TYPE 2 12", TYPE'2 3.1 1.) PANEL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL. 2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF 0 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) PLYWOOD DECKING: MIN. tin" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ZONE2 nbr nwur ZONE3 \------------------ \\ \ RIDGE _-------- \ ZONE 1 \\ \\\ \ \ ___—\ EAVE GABLE ROOF Note: Dimension (a) is defined as 10% of the minimum width of the building or 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be =:�a less than either 4% of the minimum width of the building or 3 feet. =:Ia — — — — — - — -'fa -________________ a I ZONE 1 I I FL# 11651.22 R3 •OCTOBER 5. 2017 Cont. Tape Seal ter use on Sk 9315 x 1-1/T w/Sealer Washer @ 24. O.C. Max TYPE 2 FASTENER PATTERN 5 15 x 1-1 IT w/Sealer Washer @ 12' O.C. Max less Nan