Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORT• 4 rLoxcengineering & Testing Inc. 19530 Ramblev:ood Ddvc Hn.W=77a3a Product Evaluation Report CARPORTS ANYWHERE SCANNED BY St. Ll,rie County Hawtatr Rib Roof Ponel over open framing Florida Product Approval #Z7 OZ.1 Florida Building Code 2017 Per Rule G1G20.3 Method: I—D Category: Structural Components Subcategory: Roof Deck Compliance Method: G1G203.005(1)(d) NON HVH2 Product Manufacturer: CarportAnywhere 10858 S.E. County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. N 44923 Florida Evaluation ANE ID: 1920 Validator• Gary Hartman, P.E. 073227 Contents: Evaluation Report Pages 1-4 ,NIN 01N C E'E roc r,,, .C�V. //////777777 .F No. 40e SPATE OF ;r IN xrm, I�rr,O Ir Nrl l`r, FL# 27402.1 Ju4%z18, z-01a r::��jJ 4 Force Engineering Fc Testing Inc. 39i10 Itamhleaood Drive Humble,Tt 77M3' Compliance Statement: The product as described in this report has demonstrated.cpmpliance with the Florida Building Code 2017, Sections 1504.32,1504.7. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened structural roof panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Cade 2017 Section 1507.4.3. Optional paint finish. Corrosion Resistance: Panel Material shall comply With Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: 9" major rib at 9" O.C. Panel RDllformer: MRS Metal Rollfonning Systems Panel Fastener: #12-14 x Y" HWH SD43 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4, Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade Sol Steel framing. See Table A 8, B for steel gauge. Framing must be designed in accordance iv/ Florida Building Code 2017. Allowable Design Pressures: bhl"^a^oa t;� u Maximum Design Pressure -57.3 psf -749 psf -67.7 psf +46.9 psf +543 psf Panel Fastener Pattern: 2.1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 Panel Span: 51-W O.C. 4'-0' O.C. 4•-0' O.C. 51-0' O.C. 4'-0" O.C. Substrate: Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 14 Ga. I Steel Framing Min. la Ga.7 Steel Framing Min. IB Ga. Steel Fuming —50, - 5areryrenar=2.0. PI.# 27402.1 Ntr C B 1 E 1. 7, CE NSF: A4.. ��.'''777 No. 4499 STATE OF 'PO,n••'pt O AlDA sn. araa �i f4; •. 's i rr 'r�7 /FOR L V JV4%e.1.8, 2018 rr-orccEngincerM &Testing Inc. 19530 Rambiesvuod Di,. HumblgX[ 77333 Table "B' 29 Ga. Hampton Maaimum oesrp, Pressure: -573 pzf -3509 ps( +39.0 psf ♦143.1 p,f Fastener Pattern 6'd'-6'•3"-6'd•-6' 6'•3'4i"-3'-6"-3'-6` b'-3'-6'-3'-6"-3'-6' fi'-3'$-3'E'3'-6" FartenerSpad r. 4b'0.6. 2'-0"O.C: 4'4r O.C. r-W O.G aoar=zu. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Cade 2017, Section 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61GZO-3. performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592.05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference • FM 4471-92- Foot Traffic Resistance Test Reference Data: L ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization N TSF-5328) Report No. 657-006OT-18A-E, 667-0061T-18A-D 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering &Testing, Inc. (FBC Organization N TST-5328) Report No. 667-0060T-ISF, 667-0051T.18E 3. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Farce Engineering & Testing, Inc (FBC Organization P ANE ID: 1920) Test Standard Equivalency: The FM 4471-10, Foot Traffic Resistance test standard is equivalent to FM 4471-92. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under quality assurance program audited by an approved quality assurance entity. FLO 27402.1 spttu ltrrrr 35 � %ICE' e W //// ¢ O / Q•. t C E N S <,o' A4,: � F • F l _ 4 . No. 4)s •°' STATE OF ; r ORI s ixrrr ///// 7ORAL• ENS `�` rrrrntnttt� Juc9z 1-8, 201-8 Force Engineering & Testing Inc. 10530 R hicwood Dri.e Humhtgrr77130 Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used In the panel side laps. Installation: Install per manufacturer's recommended details. Insulation: Manufacturers approved product (Optional). Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must he in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. `t�0[11 I_ rr7j CENy No. 40_a�. b' STATE OF "0 _ Fy ORI'D snrdm ire, ,;pN intEN, rL# 27402.1 Jwnz 1-8, 2.018 6' 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 #12-.14 . 3/4' IO'AI S03 P// 610l3 60NOE0 NEOPRENE flA511ER 29 GA. HAMPTON RIB FASTENER PATTERN `912-1 : x 3/4" HVWI S03 1Y/ I-I.N!.1 RON6EO NEOPRENE tVASRER &iafa vlFlntldO — GOA �2o71p 9—UNia2018 rForce Engtncecing & Testing Inc. t0530[tnubl .W Di,e Humbl.aX77338 Product EvaluationReport CARPORTS ANYWHERE Hampton Rib Wall Panel over open framing Florida Product Approval # 27403.1 Florida Building Code 2017 Per Rule 61G20-3- Method: 2-0 Category: Structural Components Subcategory: Structural Wall Compliance Method: 61GZG-3.005(2)(b) NON HVHZ Product Manufacturer: Carport Anywhere 10858 S.E. County Road 221 Starke, Florida 32G91 Engineer Evaluator: Terrence E. Wolfe, P.E. # 449Z3 Florida Evaluation ANE ID: 192G Validator. Gary Hartman, P.E. 973227 Contents: Evaluation Report Pages 1-4 SGANNFJ a BY "111111111Ir, CE NSF lam. No. 40 / STATE OF 0x19A a� rm �O�hlpk 1Nj1 NG' FL# 27403.1 Ju. L& I8, 2.01.8 t r.o.c. ED neenng,&Testing Inc. 19530 Ramble and Dive Humble,TX77338 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1709.2. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36" Wide, through fastened structural wall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1405.2. Panel Dlmenslon(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height %"major rib at 9"O.C. Panel Rollformer. MRS Metal Rollforming Systems Panel Fastener: 912-14 x Y..' HWH 5083 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: T.M. -A- 29 Ga. Nametnn nih Wall P... I Maximum Design Pressure: -57.3 psf -72.9 psf -6 .7 psf +46.9 psf +54.7 psf Panel Fastener Pattem: 2-1-2-1 2.1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 Panel Span: 51-W D.C. 4'-0' O.C. 4'-W O.0 s'-0' O.C. 4'-0' D.C. substrate; Min. 14 Ga. Steel Framing Min, 14 Ga. Steel Framing Min. 14 Ga. I Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing Design Pressure includes a 5afetyFactar= 2.0. FU 27403.1 \\\\\I \ll l rl rrvfl N C E• E tyC r•�. Mo. 40e TEOF Jru z.18, 201E Porce Enginect ng & Testing Inc. 19530 Rambkc ood Drivc Humbie,TX 77338 Table "8" 29 Ga. Hampton Rib Wall Panel Maximum Design Pressure: -57.3 Psf -y909;;0 +39.0p0 +143.1 psf Fastenerpanern: 6'd'-w-3"-6'-3'3' 6'-3-6'-3'-6' 6'-3'- Fastener5padng. 4'-0"O.G 2'-0"O.C. 4'-0'O.C. 2'-0'ox— Design Pressure Induces a sorely Factor=L4 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering & Testing, Inc. (FBC Organization # TST-5329) Report No. 667-0060T-18A-E, 667-006IT-ISA-D 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering &Testing, Inc (FBC Organization H ANE ID: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturers recommended details. Insulation: Manufacturers approved product (Optional) Panel Fire Classification: Fire classification is not part of this acceptance. t,tt1111 S�N'C E E tyo +i+i Lt CEHSF<t�i C t4o STATE OF P. ORL 9 A. 4,� s•.�mse elf'. .1}'�� rsmv +"""ORAL ENGt�` +"/lnnlnt• FL# 27403.1 jvw &18, 2018 r rporccEngincrngTesting Inc. 19530 tlancDdsc Humblc.TX77330 Shear Diaphragm: Shear diaphragm values are outside the scope of this report Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16ofthe Florida Building Cade 2017 for wall cladding wind loads. These component wind loads for wall cladding are compared to the allawablepressure fisted above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. FL# 27403.1 Jol.n.e,18, 2018 D 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 e12-14 • 3/4" H SD3 VI/ 14NN BOWED NEOPRENE P,'6M 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3 6'-3"-6" IT T-TT� ` 812-14 • 3/4' WAI S03 f9/ 14BY BONDED NEOPRENE 1'tl6RER g�pyool Florida p.OA No. 44923� STAT20 ��O�z oyt a' 1 MN 1 8 2018