Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance 81%A WM GOIN Project Name: Wade Jurney Homes -1402 BY Project address: 022LWP005 - 5305 Hummingbird Way Ft. Pierce, FL34951 St OP .on* Permit#: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (singleor multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure •'.' - . . * Note: Form not required forinterior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE:. Florida 2017 '_ Code Sixth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open '1 Risk Category:, .P•X- .II Ilt �IV Exposure Category: B X C _D 4. Design Wind Velocity160' mph ASD ' X LRFD Ehd Zone Width: 3.6 ft. 5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: N/A' ff 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'NIRH, clearly label on all plan openings): +1g,3,-30.6 +19.3,-53.3 +tg,3, 78.9 +33.5,-36.3 +33.5;-44�.8 +31.7/-38.6 Zone 1: Zone 2: Zone 3:' Zone 4: .Zone 5: _ .Garage: r 7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live'." Balcony: N/A� .PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? Y Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Y YesNot Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? . Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County: I al,\q# l VV i6ht/; fuctural elements depicted on these plans provide adequate resistance to the design forces sc�`�6 G. t/d� \�'Q�.• N F !�� James G. Friling No 24 * Print Name Cert # & Co. Cert Auth. PE #77824 COA #27228 ,.e.....y�i/ i�.„,mac', !-UK��E,e- Revised 12/07/ S7(211pp111 AR 19 2019 Mulhern + Kulp Structural Company Name & Address I = �: