HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance 81%A WM
GOIN
Project Name: Wade Jurney Homes -1402 BY
Project address: 022LWP005 - 5305 Hummingbird Way Ft. Pierce, FL34951 St OP .on*
Permit#: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (singleor multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure •'.' - . .
* Note: Form not required forinterior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE:. Florida 2017 '_ Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
'1 Risk Category:, .P•X- .II Ilt �IV Exposure Category: B X C _D
4. Design Wind Velocity160' mph ASD ' X LRFD Ehd Zone Width: 3.6 ft.
5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: N/A' ff
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'NIRH, clearly label on all plan openings):
+1g,3,-30.6 +19.3,-53.3 +tg,3, 78.9 +33.5,-36.3 +33.5;-44�.8 +31.7/-38.6
Zone 1: Zone 2: Zone 3:' Zone 4: .Zone 5: _ .Garage: r
7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live'." Balcony: N/A� .PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50 PSF
8. Were Shear Walls Considered For Structure? Y Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Y YesNot Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? . Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County: I al,\q# l VV i6ht/; fuctural elements depicted on these plans provide adequate resistance to the design
forces sc�`�6 G. t/d�
\�'Q�.• N F !�� James G. Friling
No 24 * Print Name Cert # & Co. Cert Auth.
PE #77824 COA #27228
,.e.....y�i/ i�.„,mac',
!-UK��E,e-
Revised 12/07/
S7(211pp111 AR 19 2019
Mulhern + Kulp Structural
Company Name & Address I =
�: