HomeMy WebLinkAboutPLANSGeneral Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINII�IUM, 3 1/2'NOMfNAL THICKNESS. 3. -FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON'GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (6D KS1 MIN.) DEFORMED BARS, 03 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING* OPC (PORTLAND CEMENT TYPE 1� ASTM C 150). AGGREGATES-- 66-STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +/- 1% - ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10, PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MTN1]VIUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2.ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS Y-0- IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-TS FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0,024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART I -A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART I-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN"OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE 61h EDITION (CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN 910 SMS 6"FROM THE ENDS AND 12" ON CENTER, IF USING 912 SPACING MAY BE 24" ON CENTEK 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. I"X2"XO.045"NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #IOX 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: I. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-9, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE 13OLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAM1,ER. 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER, FASTENERS SHALL BE A MINIMUM OF SAE GRADE 95 OR BETTER ZINC PLATED. I. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8. UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A 153. 10. ALL CONNECTORS SHALL COMPLY WITH ASTIM A653 CLASS G-185. i� FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART I -A, & I-B ASTM C94 ASTMC150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTMA185 FLORIDA BUILDING CODE 6th EDIY70N (CHAPTERS 16,20 & 23)� F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. I. TYP -TYPICAL 2' SIM - SIMILAR 3. UON -- UNLESS OTHERWISE NOTED 4. CONT - CONTINUOUS 5. VIF - VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROONF ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER- 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HONE, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 12. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREIJENTS OF THEFLORIDA BUILDING CODE 6(h EDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR- 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 5. SCREENING MATERIAL SHALL BE 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. 6� PLEASE NOTE: 2x2 (typ) DIAGONAL BRACING SHALL BE 2"X2'70.055" MATERIAL, UNLESS OTHERWISE NOTED ON S-2. DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISKCATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: SCREEN ROOF: 12 PSF SCREEN WALLS: 43 PSF SOLID ROOF (SCREEN WALL): N/A CGIvIPONENTS AND CLADDING LOAD: NIA 150 wu 116 APH 1 C S. THIS STRUCTURE COMPLIES WITH FBCE. 1103.2 AND THEREFORE HAS NO ADVERSE AFFECT ON THE EXISTING STRUCTURE. 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X]4XO.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 7. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 8. LIVE LOAD: 300 1b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 200 1b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 8. PROPOSED 8�XV W/ (1) A 5 REBAR W/ 25- OVERLAP ON 3" CHAIRS W/ 4" MONOLITHIC SLAB W/ FIBER -MESH FILLED W/ 3000 PSI SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: IVL4,NSA-RD I HIPPED GABLE 10. SOLIDROOFTYPE: N/A ALUMINUM STRUCTURAL MEMBERS HOLLOW SECTIONS 2 x 2: --------------------------------------- 2" x 2" x 0.044" 2 x3: --------------------------------------- 2" x 3" x 0.050" 2 x 4: --------------------------------------- 2" X 4" x 0.050" 2 x 5: --------------------------------------- 2" x S" x 0.050" 3 x 3: --------------------------------------- 3" x 3" x 0.125" OPEN BACK SECTIONS 1 x 2: ---------------------------------------- 1" x 2" x 0.040" 1 x 3: ------------------------------ --------- I" x 3" x 0.045" SNAP SECTIONS 2x2SMS: ------ --------------------------- 2" x 2" x 0.045" 2 x 3 SMS: --------------------------------- 2" x 3" x 0.072" 2 x 4 SMS: ------------ - ---------------- - - 2" x 4" x 0.045" 3 x 3 SMS: - - ------------------------------ 3" x 3" x 0.090" SELF MATING (SMB 2x4SMB: ---------------------- 2" x 4" x 0.044" x 0.100" 2xSSMB: ---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB: ---------------------- 2" x 6" x 0.050" x 0.120" 2x7SMB: ---------------------- 2" x 7" x 0.057" x 0.120" 2x8SMB: ---------------------- 2" x 8" x 0.072" x 0.224" 2x9SMB: ---------------------- 2" x 9" x 0,072" x 0.224" 2 x 10 SMB: --- --------------- 2" x 10" x 0.092" x 0.374" TUBE SECTIONS 2 x 2: --------------------------- - -- ------- 2" x 2" x 0.090" AUG 0 5 �qjq ST. Lucle r A C nxf LE COr T j*jqog�_Oos� REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCCw. E A U q.� IL C-) iZ5 411 0, LLJ 0 0 ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 �rik Stuart P.E. FLORIDA LICENSE: 77605 FBC PIans & Engineeriii Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fbcp1ans.com C.O.A.429054 DATE: 7/11/2019 I DRAWN BY: TLK I MIN M-T 17PPORN job# 190702068 PROJECT ADDRESS: BOYCE 9136 SHORT CHIP CIRCLE PORT ST. LUCIE, FL 34986 -IONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES S-1 E A U LL (0j 4, C� Z LU David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.F 1x2 FLORIDA LICENSE: 38654 Myron Max Neal P.E. -0 FLORIDA LICENSE: 86663 :-,�,Joel Falardeau P.E. 04 X x5SMB 'FLORIDA LICENSE: 70667 Erik Stuart P.E. c,44 FLORIDA LICENSE: 77605 X -0 FBC Plans & Engineering 2x5SMB 4 Services, Inc. 272 Abbott Station Dr. Unit 101 C1 ephyrEills, FL 33542 > p h# (813)788-5314 C14 Fax# 1-(866)824-7894 1x2 X E-mail-erb@fbcplans.com Website-�.Jfficplans.corn C.OA-#29054 )SED 8"X8" W/ 5 REBAR LINEAL DATE: 7/11/2019 DRAWN BY: TLK qG W/ 4" REVISION: DATE: LITHIC SLAB RO 1 R02 R03 R04 REVIEWED F R CODE COMPLIANCE ST. LUCIE COUNTY BOCC PROJECT ADDRESS: 3HORT CHIP CIRCLE ST. LUCIE, FL 34986 --ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 FLOOR PLAN S-2 ALUMINUM GUSSET 2" x —PURLINS (SEE A-1 FOR SIZE)ATTACHED TO BEAM w/MIN (4) #10 x 1 X" S SIMS IMS A Z-BRACKETO.250'* 5" OR 7'X 6" WIDTH X 0.250" EXTRUDED GUTTER BRACKET @ oll EA. BEAM W1 (4) #12 X 3/4' SIMS INTO GUTTER LIP 1" x Z" x 0.045" OPEN BACK W/ (4)#14X 1-1/2" 1 INTO GUTTER & (1)#14X- 1-1/2" @ 24" D.C. S'3 V"P'js '44X'ij'i'a BEAM "B" "N" "Sill 'PS2" "SY "S4" 2X4 12 4 3/V _iT "TT 7 2X5 12 4 3/V 1T 67 2X6 16 5 1" _1�7 75- 2X7 20 6 Ill 22" 6.75" 2X8 24 7 1" 1 " 2Y 2Y7 7. 2X9 24 7 1" 1 " 23" 83Y 2XIO 28 8 ill 1_�' NOTES: 1. "N" NUMBER OF SCREWS IN ANY DIRECTION. 2. TOTAL NUMBER OF SCREWSPER JOINT EQUALS 4 TIMES "B". 3. PLATE WIDTH SHALL BE D ETERMINED FROM ANGLE OF B RAM AND M IN. SPACE REQUIRED. 4. GUSSET PLATES MAY BE INTERNAL OR EXTERNAL. S. INTERNAL SCREWS FOR PURLIN CONNECTION MAY BE INCLUDED IN TOTAL NUMBER OF SCREWS. 6. GABLE SPLICE WILL HAVE THE SAME PATTERN. BEAM SPLICE GUSSET DETAIL TYPICAL SCALENTS 0 BEAM 1 0 mffii.i 2" x 2" x Y," X ALUMINUM ANGLE w/ (4) #14 x 3/4". SMS INTO BEAM ON EA SIDE EA. LEG 2"X2"X0.062" RECEIVING CHANNEL W1 (2) #10X 3/4" EA SIDE TO COVER EXPOSED BEAM NoTI3:2X4 SMB BEAM20NLY REQUIRES 4" WIDTH GUTTER BRACKET W/ (2) 3/8" LAGS I (4) 3/B" LAG SCREWS @ 1-1/2' SPACING @ EA. GUTTER BRACKET V—& @ 12" D.C. MAX- MIN EMBEDMENT I SHALL BE 2" THE HOST STRUCTURE SHALL HAVE AT LEAST A 2"X4' R GUTTER FASCIA AND ROOF TRUSS IS" OR 7"� SYSTEM. CONTRACTOR SHALL VERIFY THIS AND IF #12 x3/4"SMS SMALLER- CONTRACTOR 0 GUTTER EA SIDE SHALL BRING STRUCTURE UP TO A 2"X4" FASCIA AND ENSURE LESS THAN OVERHANG. rA *� GUTTER BRACKET & BEAM ATTACHMENT DETAIL ��3 N.T.S. UPRIGHT WEB LAPPED OVER PURLIN W/ (2) 912X3/4" SMS EACH SIDE- THRU UPRIGHT & PURLIN 2"X2"MEMBER ATTACHED TO UPRIGHT W/ (3) #1 OX1-1/2" SMS- INTO SCREW BOSS 1"12"X0.045" OPEN BACK ATTACHED TO PURLIN W1 (2) #10X1-1/Z" SMS INTO SCREW BOSS 1"X2"XO.045" OPEN BACK ATTACHED TO 2"X2"X0.04S" EAVE RAIL MEMBER #ioxi-1/2-- SMS @ 24" O.0 rc_'� SLOPED OR FLAT PURLIN UPRIGHT LAP DETAIL 1\t3� SCALE: NTS BEAM SCREWS 2" X 4" SMB 6 2" X 5 "SMB 6 2" X 6 "SMB 8 2" X 7" SMB 8 21, X 81, SMB 10 2" X 9" SMB 10 21, X 101, SMB 12 HINGE LOCATION— - BEAM—\,] (2) #10X3" SIMS CROSS FOR SLOPED BEAM SCREWING BRACETO BEAM OR 2" x 2" EXTRUSION— - MAINTAIN ALL SCREW SPACING RAVE MEMBER (.125- BACKING 2" x 2" EXTRUSION FROM EDGE OF BEAM 1ELF�MATING BEAM PLATE USED) SHALLBE NOTCHED HINGE LOCATION— DOOR 2" x 2' EAVE RAIL SECTION -7-f F45/1, FOR UPRIGHT (UNLESS OTHERWISE SHOW ON S._2 ROOF -ATTAC BED To BEAM _/ 'R BRACE (3) IOX 2" SMS INTO SCREW EAVE PAIL----,,,,, BOSS 0 0 I" X 2" OPEN BACK PAVE RAILATTACHED TO 0 UPRIGHT W/(2) (1) 3/8-0 THRU HINGE LOCATION I 410 x 136" SMS INTO SCREW BOLT W/ NYLON LOCKING 2"X"2"X.125" FLAT BOSS NUT OR THREAD LOCKING BAR (typ) 2" NOTCH OF INSIDE BEAM N MATERIALAPPLIED 910 X 1 X" SIMS 24l'C/C TO SLIDE OVER UPRIGHT NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 x 5/8" SMS MINIMUM. Lz�= 2. DOOR SHALL BE ATTACHED TO ENCLOSURE W/(2) HINGES MINIMUM. 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x 5/8" SMS. FASTEN A I" x 2" x 0.044"TO UPRIGHT W/#12 x 1" SMS @ 12" D.C. AND WITHIN 3" FROM ROOF BRACING CONNECTION DETAIL END OF THE UPRIGHT. SCALE: N.TS. "�TYPICAL SCREEN DOOR CONNECTION DETAIL SCALE;NTS #14X (MIN) UPRIGHT UPRIGHT TO BEAMCONNECTION -ALL WIND ZONES SCALE: NTS E A U A, CO LL C� Z 01 0 _T ;Z 1-vi-IB ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. IFLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Mans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-S314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fbcp1ans.com C.O.A.429054 DATE: 7/11/2019 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 ADDRESS: 36 SHORT CHIP CIRCLE )RT ST. LUCIE, FL 34986 .-ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-3 V. - OPTIONAL UPRIGHT 9 l- A U, SECONDARY ANGLE MIN S" OR 7"-X 0.250" 0.125" THICK (NOT EXTRUDED GUTTER (4) 910 X 3/4" SMS 2!j REQUIRED FOR 2X3 FZ-BRACKET 0.250" BRACKET FASTENING SECONDARY MEMBER) * Q % . ANGLE TO COLUMN (TY LL Q (D EACH SIDE) 0 Z PRIMARY 2" X 2" 1(/ Uj 2- GUTTER BRACKET REQUIRED _j 0 0, /Z OPTION #1 SMS X 0.125" ANGLE )ARY TY DE) 0 R AT PURLIN ATTACHMENT W POINTS W/(2) #1ZX3/4"SMS (1) 3/8" LAG SCREWS @ EA. GUTTER (B)-CONCRETESCREW (2) #10 X 3/4" SMS FASTENING INTO GUTTER LIP ----I BRACKET & (1) @ 12" D.C. MAX- MIN ANCHOR INTO SECONDARY I SEE COLUMN TO PRIMARY ANGLE 0 ILE) (TYP EACH SIDE) EMBEDMENTSHALL BE 2" (4)010 x 1 X" SMS TNT OPTION #2 ANGLE(TYP EACH SIDE) (SEE "c) I" x 2" x 0.045" OPEN SCREW BOSSES-7 TABLE) 0 0 C, NS, BACK W/ (2)#14X 0 1" X 2" BASE MEMBER — — — — — (TYP EACH SIDE) P 1-1/2" @ ANGLE & ANCHORSPA '1) 4 (1)#12X2- IL — — — — — E T .4 PRO I TETER SEA D.C. OR - — — — — — (1)- CONCRETE SCREW (SEE (T.YP)(SEETABL 1 '4 TABLE) ANCHOR INTO PRIMARY ENGINEER OF RECORD: 1/'"N (MIN) OF 10 2"X2-10.045L 0.062'ALUMINUM INTERNALOR ANGLE AND @ 1/4" 0 CONCRETE MEMBER EXTERNAL RECEIVING CIVINNEL W1 (4) #10 X 3/4- INTO INTO 3" (MIN) SCREWANCHOR@) David W. Smith P.E. BEAM OR UPRIGHT. (2) #14X 3/4" Z4" D.C. BETWEEN COLUMNS FLORIDA LICENSE: 53608 PURLIN EA. LEG INTO GIRT OR PURLIN - 0 0 (0.062" ANGLE CLIPS W/ (2) 00 tf14x3/4.'SMSEALEG) UPRIGHT OR BEAM -SNAP TFA OR SELF MATING OR THE HOST THE HOST STRUCTURE SHALL HOLLOW 2" x 2" x X ALUMINUM L '�4X HAVEATL X HAVEATLEASTA2 4;S rH PURLIN OR GIRT TO BEAM OR POST DETAIL ANGLE W/ (4) 912 1 z 34 S C FASCIA AND ROOF I�R IAANT U \,§ SCALE:NTS SMS INTO PURLIN ON FAI SYSTEM. CONTRACTOR SHALL SYSTEM CC �4 SIDE I VERIFY THIS AND IF & (4) 12X1-1/2" INTO SMALLER- CONTRACTOR GUTTER SHALL BRING STRUCTURE UP TO A 2'14" FASCIA AND Column Size 1/4"& 3/8" 0 Concrete Screw Anchor B Min. Spa _E�3_-1/4 —0 �O 2X4-1/4" 1 3' 2x5-1/4" 1 3 2Z6--3/8' —1 �4 �5 �3 �4 _T�5 NOTES: (TYP EACH SIDE) Thomas L. Hanson P.E 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. FLORIDA LICENSE: 38654 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING Myron Max Neal P.E. SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT FLORIDA LICENSE: 86663 LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING � el Falardeau P.E. WHEN A PAVER DECK IS PRESENT. j to 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ORIDA LICENSE: 70667 ON S-1, D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED Erik Stuart P.E. BY ENGINEER. 4.2X3W/1X2 CORNER POST SHALL REQUIRE SAME BASE FLORIDA LICENSE: 77605 CONNECTIONS AS 2X4 SHOWN IN TABLE. ENSURE LESS THAN A 2-4- FBC PIans & Engineering OVERHANG. 2" x 3" OR LARGER UPRIGHT TO CONCRETE W/WO PAVER DETAILS Services, Inc. GUTTER BRACKET & PURLIN ATTACHMENT DETAIL 6272 Abbott Station Dr. Unit 101 N.TS. \\�4 SCALE:NTS Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 I" PER FT. MAX FOR 2'-0" z E-mail-erb@fbcplans.com MIN BEFORE STEEPER NOTE: WHEN USING OPTION #2 Website-www.Ifficiplans.corn SLOPE CONNECTION CABLE MUST BE L —MIN. C.O.A.429054 GRADE OPTION 41 - A-36 STEEL WITHIN 6" OF CORNER OR _\ I., .. CLIP MAY BY PLACED ON PRIMARY MEMBER. 1/8" ALUMINUM :5 N _-4 TOP ORSIDE OF DECK W/ V X 2- X 1/8" ANGLE PLATE @ 45* DOUBLE COMPBESS'o S 50 ANGLE W/ V DATE: 7/11/2019 4111UL— SLEEVE (2) 3/8"X 3- SLEEVE BREAK @ 90- W/ Topo' ANUOR (4,1112 X 3/4- SMS T FLAT SLOPE NO FTG 4"NOMINALSLAB (TYP To EYE BOLT DRAWN BY: TLK TYPEI Z 1114CIRITE �PAND SIDE) 5/16 :5 W/ LOCK NUT & 2:1Z C, MINIMUM ASHER EA SIDE REVISION: DATE: Zn ""'A WED FLA OPTION #1 1/8" DIA. STAINLESS (9) 414 X 3/4 S RO 1n = V I E 4' STEELCABLE @r D.C. GRADE 't Dom ;i zIr_ WELDED STAINLESS 3/8 3/8" 0 x 3" MASONRY 2500 PSI CONCRETE W1 WELDED WIRE OR STEEL EYE BOLT ION #3 ST. LU �JE ANCHOR (MIN 3-3/4" OPTION#1 -y (1)05 REHAR CONTINUOUS W - / 25" EMBEDMENT) (4"ILAB ONLY) FIBERMESH 1� (8) tf14 X 3/4 SMS OPT RO 4 OVERIAP AT ALLJOINTS ON 3 -lr%d (1) #5 CONT ON 3" Loll CHAIM & CENTERED 0.125" STAINLESS -Side View I-O(MIN)WA ER job# 19-0702-OGB-' CHAIRS 01 TAN BENEATH NUT MN 1/8 ' A PLATT N ..... ANGL ES (2) 3/8 X BREA TOPOF ANM OR 5/1 CONCRETE 6' W/ LC ASH SM (9) 414 KX3/4 'Y 2,TTO 'S, T3T/. WEYDE 'l 0 C OPTION S r IN ")"'RE". CON WEIt" AT ALL D IT & CENTER, LESS STEELCABLE 2500 PSI CONCREMW/' PROJECT ADDRESS: TYPE 11 MONOLITHIC SLAB TOPOF WELDED WIRE OR ET LINEAL RIBBON MODERATE SLOPE FTG CONCRETE FIBERMESH B13YCE FOOTING SLOPE: 2":12" - 3":12' 9136 SHORT CHIP CIRCLE OPTION #2 OPTION #3 4"NOMINALSLAB 3/8" 0 ADJUSTABLE EYE PORT ST. LUCIE, FL 34986 ,4 NOTES FOR ALL FOUNDATION TYPES: MINIMUM 0 4 Top View BOLT FOR CABLE TENSION 1. THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL BEARING PRESSURE OF 1,500 OPTION #2 l/W 0 STAINLESS CONTRACTOR: PSF. THE BEARING CAPACITY OF THE SOIL VERIFIED BY A LICENSED CONTRACTOR PRIOR TO STEEL CABLE ANY POURING OF CONCRETE 1-1/2" X S-1/2- ALUMINUM OPTION #2 K & S INDUSTRIES, INC. 2. THE SLAB/FOUNDATION MUST BE CLEARED OF ALL DEBRIS, AND COMPACTED PRIOR TO V/ ( I 8� OX C, I IT TI G) POURING OF ANY CONCRETE. STRAP W1 (2) 3/8 "0 X 3- CUSE WITH FOOTING) 1379 SW BILTIVIORE ST. 3. CONCRETE MEET THE SPECIFICATIONS IN THE S-1 NOTES PAGE. MASONRYANCHOR PERIMETER FRAMING-J (MIN 3-3/�-�BEDMENT) L-1-i 2"X2"X 1/8"' EXTRUDED ANGLE PORT ST LUCIE, FL 34983 CONTINUOUS LINEAL FOM OR FOOTING W1 SLAB J1 )CABLE TO FOUNDATION CONNECTION DETAIL ON 45- ANGLE SCALE:NTS Side View OPTION #1 rjf� CABLE CONNECTION AT CORNER DETAILS ��4 SCALE:NTS S I 'it I ILI" ED)