Loading...
HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATE012, Y Envelope Leakage Test Report (Blower DoofCANNM BY Test) StludeCounty Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building rnrqn, Pnoraw rnncarvatinn r,+k i:rctinn Jurisdiction. Lucie County Permit # Job Information Builder: Black Street Enterprise Lot: A Ar d , e,cS-: 101 C-11 Sito ct Unit: City: Port St Lucie State: Florida Zip: 34983 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method PRESCRIPTIVE METHOD" The building or dwelling unit shall be tested and verified as having an airteakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. PERFORMANCE or ERI METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACH. ACH(50) spedfied on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): F I rl) X 60 8384 Method for calculatinp-building volume: .443 CFM(50) BuildingVolume ACH(50) YAD Retrieved from architectural plans 0 PASS 1-1 FAI L Code software calculated a When CH(50) is less than 3, Mechanical Ventilation installation Field measured and calculated must be verified by building department. all C' I rT,,t,ng Te.,tingshall be conducted in accordance with ANSI/RESNET/ICC380 and reported ata pressure orO.2 inchew.g. (50 Pascals). Testing uct y shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues or individuals licensed as set forth in Section (g); or (i) or an approved third party. A written report of the results of the test shall be signed bythe party conductingthe test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: I.Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but notsealed beyond intended infiltration control measures. 2 , 1 , n * te * r;nr An^ , re , if installed at the time of the test, shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. S.Heating and cooling systems, if installed at the time of the test, shall be turned off. 6.Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name* Kuebler Mechanical LLC. phone: 772-878-2281 1 hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to e mpliance method selected above. Signature of Tester:— Date of —rest: Printed Name of Tester: Daniel Lipp License/Certification #: CAC058105— - — Issuing Authority: Retrotec