Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION . Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: PATTERSON RESIDENCE Builder Name: ISCANNED Street: 191 SE EL SITO COURT Permit Office: ST. LUCIE COUNTY By City, State, Zip: PORT ST.LUCIE, FL, Permit Number: Omer: DAVID PATTERSON Jurisdiction: st'Ludecounly Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1072.0 sqft.) insulation -Ar-ea Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=13.0 1072.00 ft- b. N/A R= ft2 3. Number of units, if multiple family I c. NIA R= ft2 4. Number of Bedrooms 2 d. NIA R= ft2 S. Is this a worst case? No 10. Ceiling Types (1048.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1048.00 ft2 6. Conditioned floor area above grade (ft�) 1048 b. NIA R= ft2 Conditioned floor area below grade (W) 0 c. N/A ft2 11. Ducts R 112 7. Windows(57.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/C 6 125 a. U-Factor; SgI, U=0.65 67.00 11:2 SHGC: SHGC=0.25 b. U-Factor: NIA ft2 12. Cooling systems kBtuthr Efficiency SHGC: a. Central Unit 23.6 SEER:16.00 c. U-Factor. N/A SHGC: 13. Heating systems kBtu1hr Efficiency d. U-Factor: N/A a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. FloorTypes (1048.0 scift.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1048.00 ft- b. Conservation features EF: 0.950 b. N/A R= ft2 None c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.054 Total Proposed Modified Loads: 31.88 PASS Total Baseline Loads: 37.89 1 hereby certify that the plans and specifications covered by Review of the plans and S this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance -P with the Florida Energy Code. PREPAR-ED BY- Before construction is completed DATE: t-26-19 this building will be inspected for compliancewith Section 553.908 I hereby certify that this building, asi, Ueigned, is in compliance Florida Statutes. with the Florida Energy Code. Z) WE OWNERIAGENT: BUILDING OFFICIAL: 'DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Complhince requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 712612019 11:03 AM r=nergyGauge@) USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page I of 5 I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: PATTERSON RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1048 Lot # Owner Name: DAVID PATTERSON Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 315 Street: 191 SE EL SITO COUR Ffermit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zipl PORT ST.LUCIE, Family Type: Single-family FL, New/Exisfing: New (From Plans) Comment: CLIMATE Design Temp V Int Design Temp -Heating Design DailyTemp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—VERO—BEACH—MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1048 8384 SPACES Number Name Area— Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated l MASTERBEDROO 171 1368 No 1 1 1 Yes Yes Yes 2 BATH 40 320 No 0 1 Yes Yes Yes 3 AIC 9 72 No 0 1 No Yes Yes 4 BEDROOM 2 188 1504 No 1 1 1 Yes Yes Yes 5 HALL 32 256 No 0 1 No Yes Yes 6 M BATH 60 480 No 0 1 Yes Yes Yes 7 UTILITY 48 384 No 0 1 No Yes Yes 8 KITCHEN 156 1248 Yes 0 1 Yes Yes Yes 9 LIVING/DINING 344 2752 No 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTERBEDRO 28ft a 171 ft- 0 1 0 2Slab-On-Grade Edge Insulatio BATH 5ft 0 40 ftz 0 1 a 3 Slab -On -Grade Edge Insulatilo AJC Ift 0 9 ft- 0 1 0 4 Slab -On -Grade Edge Insulatio BEDROOM 2 33 ft 0 188 ft- 0 1 0 5 Slalp-On-Grade Edge Insulatio HALL ift 0 32 ft- 0 1 0 6 Slab -On -Grade Edge Insulatio M BATH 6ft 0 60 ft2 0 1 0 7 Slab -On -Grade Edge Insulatio UTILITY ift 0 48 f12 0 1 0 7/26/2019 11:03 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS FloorType Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulado KITCHEN 25 it 0 156 ft? 0 1 0 9SIab-On-Grade Edge Insulatio LIVING/DINING 37ft 0 344 ft2 0 1 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1135 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.6 ATTIC V# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1048 ft2 N N CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTERBEDRO 30 Blown 171 itz 0.1 Wood 2 Under Attic (Vented) BATH 30 Blown 40 ftz 0.1 Wood 3 Under Attic (Vented) A/C 30 Blown 9 ft� 0.1 Wood 4 Under Attic (Vented) BEDROOM 2 30 Blown 188 it. 0.1 Wood 5 Under Attic (Vented) HALL 30 Blom 32 Itz 0.1 Wood 6 Under Attic (Vented) M BATH 30 Blown 60 ftZ 0.1 Wood 7 Under Attic (Vented) UTILITY 30 Blom 48ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blom 156 ft2 0.1 Wood 9 Under Attic (Vented) LIVINGIDINING 30 Blom 344 it- 0.1 Wood WALLS y A C)Mt Adjacent Cavity Width T� WRII Type Space R-Vahm Ft In Height Ft In Ar�g Sheathing Framing Solar RAI,1,,� F:�,,t �n Ahq�, (1mri,% Below 1 SE=>E Exterior Concrete Block - Ext InAMSTERBED 13 16 0 8 0 128.0 f12 0 0 0.5 0 2 SW=>S Exterior Concrete Black - Ext InAMSTERBED 13 12 0 8 0 96.0 it- 0 0 0.5 0 3 SE=>E Exterior Concrete Block - Ext Insul BATH 13 5 0 8 0 40.0 it- 0 0 0.5 0 4 NE=>N Exterior Concrete Block - Ext InAEDROOM 2 13 14 0 8 0 112.0 112 0 0 0.5 0 5 SE=>E Exterior Concrete Block - Ext ImIREDROOM 2 13 15 0 8 0 120.0 ft2 0 0 0.5 a 6 NW=>W Exterior Concrete Block - Ext In.QEDROOM 2 13 4 0 8 0 32.0 ft2 0 0 0.5 0 7 SW=>S Exterior Concrete Block - Ext InsulM BATH 13 6 0 8 0 48.0 ft2 0 0 0.5 0 8 SW=>S Exterior Concrete Block - Ext InsuKITCHEN 13 13 0 a 0 104.0 it- 0 0 0.5 0 9 NW=>W Exterior Concrete Block - Ext InsuKITCHEN 13 12 0 8 0 96.0 ft2 0 0 0.5 0 10 NE=>N Exterior Concrete Block - Ext InsUVING/DINI 13 17 0 8 0 136.0 ft2 0 0 0.5 0 11 NW=>W Exterior Concrete Block - Ext InskAVING/DINI 13 20 0 8 0 160.0 112 0 0 0.5 0 7126/2019 11:03 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS 9 Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 NW=>W Insulated 2 NE=>N Insulated KITCHEN None .39 3 LIVING/DINI None .39 3 6 8 6 8 20 ft- 20 ft- WINDOWS Orientation shown is the entered orientation (=>) changed to As Built (rotated 315 degrees), Wall V # Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW=>S 2 Vinyl Low-E Single 2 NE=>N 4 Vinyl Low-E Single 3 SW=>S 8 Vinyl Low-E Single 4 NW=>W 11 Vinyl Low-E Single Yes 0.65 0.25 N 15.0 ft- 2 ft 0 in 1 ft 4 in Yes 0.65 0.25 N 15.0 ft- 2 ft 0 in 1 ft 4 in Yes 0.65 0.25 N 9.0 ft' 2 ft 0 in 1 ft 4 in Yes 0.65 0.25 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 j Wholehouse Proposed ACH(50) .000356 978.1 53.7 100.99 .1233 7 HEATING SYSTEM y # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 k8tuthr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts I Central Unit/ Split SEER: 16 23.6 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Carl # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft. DUCTS supply # Location R-Value Area Return Air CFM 25 CFM25 Location Area Leakage Type Handier TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 125 ft- Attic 45 W Default Leakage A/C (Default) (Default) I � 1 1 7126/2019 11:03 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: COW' HJ n H Feb Heatin'g Jan Feb N Mar Mar Alp, Apr I j Mayy Me 11 JJ,,,, Jul J1 Jul Aug �j Aug n SS:pp Oct N Oct Nov Nov Dec [I Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thormostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 a 9 10 11 12 Gooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM so 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 76 78 PM 78 78 78 78 78 78 78 78 78 78 78 -78. Ileating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.fL a ft- 0 ft 0.3 MASTERBEDROO Default(8 lbs/sq.fL ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 A/C Default(8 lbs/sq.ft. ft2 It 0.3 BEDROOM 2 Default(B lbs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 It 0.3 M BATH Default(8 IbSIsq.ft. ft2 ft 0.3 UTILITY Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 IbS/sq.ft. 112 ft 0.3 UVINGMINING 7/26/2019 11:03 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 84 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-fami y b) Return ducts R 6.0 c) AHU location A/C 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity___23.6 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1048 d) Room unilJPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 7.0 c) Area 7c. 57.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA a) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (insulation R-value) IOAl. a) Dedicated heat pump with tank EF 2. Masonry (insulation R-value) IOA2. 13.0 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) IOBI. 2. Masonry (insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic Ila. 30.0 b) Cross ventilation No b) Single assembly Ilb.- c) Whole house fan No c) Knee wallstskylight walls llc._ d) Multizone cooling credit d) Radiant barrier installed lld. No a) Multizone heating credit f]l Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed b d installed code compliant features. Builder Signature: Date: Address of New Homd: 191 SE EL SITO COURT Cfty/FLZip: PORTST.LUCIE,F 7/i612019 11:03:17 AM EnergyGauge@ USA 6.0.03 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of I Job: wrightsoft Project Summary Date: Entire House ST. QUICK CALCS, INC. 31,7 STILUCE LANE, FORTPIERCE,FL34946 Phom:772-466-6799 Emil: QUICKCALCS@AOL.COM I Proiect Information, For. PATTERSON RESIDENE 191 SE EL SITO CT., PORT STLUCIE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TO 15 OF Dailyrange M Relative humidity 50 % Moisture difference 61 grfib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10909 Btuh Structure 10164 Btih Ducts 2685 Btuh Ducts 3765 Btuh Central vent (0 cfim) 0 Btuh Central vent (0 cfim) 0 Btuh (qone) (none) Humidification 0 Btuh Blower 0 Bluh Piping 0 Btuh Equipmentload 13593 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipmenl sensible load 13233 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2310 Btuh Ducts 1064 Btuh Central vent (0 cfirn) 0 Btuh Heatin cool* M (none) Area (fF) 10 1 Equipment latent load 3374 Btuh Volume (fP) 9432 9432 Air changesthour OA5 0.23 Equipment Total Load (Sen+Lat) 16607 Btuh Equiv. AVF (cfm) 71 36 R6q. total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mf�. Trade Trade GOODMAN Model Cond GSX160241F AHRI ref coil ASPT30C14A AHRI ref 200825156 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heatrig input 3.8 kW Sensible cooling 16520 Btuh Heating output 12797 Btuh Latentcooling 7080 Btuh Temperature rise 50 OF Total cooling 23600 Bbuh Actual airflow 233 elm Actual airflow 787 cfm Airflowfactor 0.017 cfim/Btuh Airflowfacor 0.056 cfm/Bbjh Static pressure 0.50 in H20 Static pressure 0.50 in H20 Space thermostat Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed �rletlt��ft- 201 9-JU-26 11:0538 Ngtt�SLiLOLhi�rwl2Ol9l9.007RSUa8lO1 Page 1 -.�rts�WdghsDftHVAC%PATTERSONRESIDNCF—� Calc=MJ8 FnxtDoorfam& S wrightsoft Right-JO Worksheet Job'. Entire House Date: QUICK CALCS, INC. By: 317ST LUCIE LANE, FORTPIERCE.FL34946 Phone: 772-466-6799 EnnaU:QUICKCALCS@AOL.COM I 2 3 4 5 Roorn narne EVosec�dl Roorn height Roorn dimensions Roorn area Entire 11� 136.0 It 9.0 It 11348.0 IF WASTERBEDROOM 24.0 It 9.0 it heatbod IZO x 12.0 It 144.0 fe Ty Conshjcdw number U­value (BbihAF-9 Or HTM (BbuK412) Area (IF) or Wmeter (ft) Load (Btuh) Area (T) or pen . motor (ft) Load (Bbih) Heat cool Gross N/PIS Heat c4ol Gross M/P/S Heat cool 6 t=G 1341ZS66i_,__ 13A-1Z5ocs 1A-dw 11DO_____._ 13A-12-lom 1A�clorn 11DO _10-:36 _____Ob65 _1270 0.065 0065 1270 _0390 OJD65 1270 — 03M .OJD32 0_989 --ne -ne- se -11.82 ___35.56 1,82 - --- 0_78 _ _70,43 0.78 —0.78 53.01 - 10.34 0.78 70.43 10.34 =1.0 ___0 OP 333 ­279 15 — _21 333 18 21 =048 94-8 7- -270 333 - -4., 320 606 533 �229 535 640 229 _,_:::_Z939 -__�,,,j 634 260 ___190 795 217, 229 1268 217 —=-1677 -108 - 0 0 -..,,-0 0 0 0 _'�_=144 144 __108 108 —0 0 0 0 0 0 *197 197 __O 0 __O 0 0 0 665 84 84 a -0 0 0 0 w OF sw _w nw rry M 35.56 _10.92 1,112 35.56 10,92 — --0.90 _277-69 —243 7 ___21 294 0 21 _77:__10M _C7 _F _ ____O 61 AED ra... 951 -7 1 EnvelopelossIgain 8732 6648 118T 392 12 a) Infiltration b) Roornmardaton 21T71 0 596 0 384 0 105 0 13 Internal gains 0—pants@ 230 Applianoesbilher 4 920 2000 1 230 a Subtotal Otnes 6 to 13) 10909 10164 1571 727 14 15 Lesseidernalload Lesstransfer Redisbribulicn Subbial Dudloacs 0 0 0 109W 205 0 0 0 10164 37% 25% 379/6 0 0 9 Iwo 389 0 0 16 744 Z76 Total roorn load Air reqLdred (dhi) 13593 233 139M 787 1969 34 1019 58 Calculabonsapp Dyed byACCAto meet all requirements of Manual J 8th Ed A& R911-SUteOUTiversaI201919.0.07 RSU08101 2019-JU-26 11:a5:38 -.�MlWdgh�AftHVACPATrERSONRESIDNCEjw Calc=KM FrantDoorfamES Page I wrightsoft Right-M Worksheet Job: Entire House Data: QUICK CALCS, INC. Br 317 ST LUOE LANE, FORTPIERCE,FL34946 Phom:772-466-6799 E�i]:QUiCKCALCS@AOL.COM 3 5 5 T2 1 ir clr�ielgnl Rccrnarez� WIC 2 5.0 a 9.0 ft heatkod 5.0 x 5jo It 25.0 W PWOR. 0 It 9.0 ft heatbDol 3.0 x 7.0 ft 21.0 W Ty Construction number U-value (BbjhfiF-'g or HTM (BluhAF) Am OF) or perimeter (ft) Load (Bluh) Area (fl or perimeter (ft) Load (Btuh) H e.1 I Cool G. I N/P/S Heal Cool Gross WRIS Heat Cool 6 V� 13XIZ56cs�' IA-cicm 13A-125cZs 13A:IZ56cs- 1A-dw 11DO 13Arl2.S= 1A-dm 11DO 16B,30a-d-- 22ktpl 0.065 AM 0.065 ----0.065 127U UM 0.065 1.270 0390 ---0.032-- __O�l)89 -ne no se &v- w w m m m ' 1.82 .3556 122 ----Jk 35.56 __�0.92 1.82 35.56 10.92 -0 .90 27.619 0.78 70.43 0.78 --0.78 53.01 10.34 0.78 70.43 10.34 --160 -. . 0.00 0 45 ----0 0 0 0 0 0 ---.-25 25 --0 _0 45 0 -.0 a2 ---0 0 0 0 0 0 - ---.22 138 0 0 35 0 0 0 0 0 0 40 0 -0 0 0 -----0 0 0 0 0 0 21 0 _0 0 ---0 0 0 0 0 0 21 --0 0 0 0 '0 0 0 0 0 0 --19 0 0 10 0 --0 0 0 0 a 0 -----34 0 w ---0 .0 -0 0 0 0 - --2Z 5 T:::DG F - - - - -------- 6 c) AED exoxsion -1 0 Envelope lossIgaim 243 74 19 33 12 a) Iniltration b) Rocrnwriblabon 80 0 22 0 0 0 0 0 13 Internal gairs Occupants@ 230 ApplianoesbMer 0 0 01 01 0 0 SubbWoines(iboU) 323 96 19 33 14 151 LesseAernalload Lessfransfer Redistibudon Subtotal Ductloads 25-/.1 37/6 0 0 0 3M 79 0 0 0 96 36 25% 37% 0 0 14 33 8 0 0 24 58 21 Total roonn load Air required (chn) 402 7 132 7 41 1 79 '41 Calculations approved byACCA to meet all requirements of Manual J8th Ed. p! 2019-M-2611.05:38 A%K gft-SUte@Uriwrsal20l9l9.0.07RSLIOBIOI Page 2 -.�rts�WdgtgsoftHVALFATrERSONRESIDNCr.n4) Uc=Wil FrontDoortaces:S wrightsoft* Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. BY. 317 ST LUCIE LANE, FORr PIERCE, FL34946 Phone: 772-466-6799 E=il:QUCKCALCS@AOL.COM 1 2 3 4 'S Roomname EVOsecivall Room he!ght Room dimensions Rcom� BEDROOM2 31.0 It 9.0 11 heatibool 1.0 x 164.0 It 164.0 ft2 HALL 0 ft 9.0 It heatbool 4.0 x IIJO R 44.0 If Ty Conshudon number U-value (BILWLT) Or HTM (Buff) Ara, (jF) or penmeter (0) Lead (BWh) Area or perimeter (ft) Load (Btuh) Heat Cool G. NP)S Heal Cod G. NOS Heat Cool 6 13A;12-1;66-- -1A,1om _ , __ 13A-12-10M 1A-dom �11DO 13A-1Z5ocs 1A-dom - 11DO - -- .16EI:36ad— 0.065 _1270 0.065 ---6.065 IZM 0390 0.065 1270 ____O 390 0.13i2 0289 ife ffe7 se 122 3556 1.82 " --122 35M 10.92 IA2 351% 10.92 ---0.90 _27_69 0.78 _70.43 0.78 --6.78 53.01 10.34 0.78 70.43 10.34 1.60 __q.09 0 --G 126 IG8 15 .,0 45 0 a --0 1-0 126 93 7 --0 45 0 0 164 _31 --0 1 --- -0 229 -169 533 -0 82 0 0 -0 98 -------- 73 795 0 35 0 0 --- 262 ---0 0 _0 0 ----0 0 0 0 0 % -44 44 0- -0 0 0 a 0 0 a 0 -44 -----a - 0 __O 0 -------0 0 0 0 0 0 39 - a _0 0 ---0 a _'O 0 0 0 -:70 w --EW w w nw m rw __O �--40 ' C�=' F --7164 164 --- 147 .__-858 -----o 61 )AED.,d., 475 Envelope Icsstain 2019 1738 39 7a 12 — a) Inffibraton b) Roommerriladon 496 0 136 0 0 a a 0 13 Intannalgaim 0001pant5@ 230 ApplianceskIter 1 230 0 0 . 0 0 Subbtalomes6t313) 2515 2104 39 70 14 15, LeaseMannalload Lesstransfer Recisinbuton Subtotal Ductloads 1 259/61 37% 0 0 6 2522 621 0 0 11 2115 783 25% 37% 0 0 -V 0 0 0 0 -70 0 a Total noom load Pirrecldred(dim) 1 1 3142 54 2898 164 0 0 0 0 CalculAtions approved byACCA to meet all requirements of Manual J 8th Ed Aft-rk- =Rwft� 2019-jtA-26 11.0518 , Pligtt-SuftBOLIniversal 2019 19.0.07 RSUD8101 Page 3 -�rtsAWdgt�oftHVAQPATFERSONRESIONCE.rLo Calc=WB FmrtDwrfaoe�S wrightsoft, Right-M Worksheet Job: Entire House Date: QUICK CALCS,r INC. By; 31 7 ST. LUCIE LANE. FORTPIERCE, FL34946 Phow: T72-46M799 EmB:QUCKCALCS@AOL.COM I 2 3 4 5 Rwn rarne EVOwdwall Room Wght Roomclimensions Roomanea MRATH 6.0 It 9jo ft heaVoDot 6.0 x 10.0 It 60jo T UTII-rry 0 ft 9.0 ft heatbod 6.0 x 8jo It 48D 111' TY COnSITICIfOr number U-value @Uhft�*O Or HTM (Ehuh&) Am (IF) or perimeter (11) Load (Bbuh) Am (fF) a perimeter M Load (Bbih) I Heat I Cod G. NIRS Heat Cod Gross NIPIS Heat cool 6 11 VL— M-IZ56cs IA -dam -- - 13A-12-1� '13A;4ZS� 1A-clom 11DO---" 13&125ecs 1A�Iom 11DO 22L-gal 0.065 j 270 0.065 6.665 1270 0-190 0.065 1270 0390 0.032 0589 - ne- - ne se -�W sw aw rw w w 1.82 - 35.56 1.82 ---1.82 35.56 _10.92 1.82 35.56 10.92 --0,90 --RM 0.78 70.43 0.78 0.78 53.01 , 10,14 0.78 70.43 1034 —1 .60 _—PJCP -54 _0 0 ------ 0 0 0 0 0 0 60 §0 '54 __O. 0 - ------- 0 0 _ ____O 0 a 0 , 60 6 ---w _____O 0 —'--'-o 0 _, ,_ 0 0 0 7=54 166 -.42 _0 0 -0 0 0 0 0 ---=96 0 0 0 ----0 0 ____ " 0 0 0 -----48 48 _0 0 ---d 0 ____.--o a a 0 ---=48 0 0 0 --7-6 0 -- --0 0 0 0 ---=43 0 0 0 0 0 _0 0 a 0 -77. 0 _G w F 6 c) AED wunim -2 -1 Enclope 10mbah 318 137 43 76 12 a) MtMw b) Roomveftlation 96 0 26 a 0 0 a 0 13 Irk -mat gal= O=jparft@ 230 Appliancesther 0 a 0 0 0 a Subbota(lines6bo13) 414 163 43 76 14 1 151 Lessoclemalload L�tansfer Redishibujon Subblal Ductloads 25% 37% 0 0 0 414 1021 0 0 0 163 60 25% 370/ 0 0 9 62 13 0 0 16 92 34 Total ream lead Air requmd (ft) 516 91 2231 13 65 1 126 7 Calculakons—aw—oved byACCAto meetall requirements of Manual J 8th Ed -!n� - -2611:05:30 =rL "!E� Pight-Stite(IDUniversaI2019 19.0.07FZiUO8101 A�k -pl' a 2019.hJ Page 4 -.�rtshWdghmftWAC,PATrERSONRESIONCEMV CaIc=IvU8 FrortDoorfaces: S wrightsoft, Right-M Worksheet Job: Entire House Data: QUICK CALM, INC. B y: 317 ST LUCE LANE, FORT PIERCE. FL34946 Phone: 772-466-6799 E=il:QUICKCALCS@AOL.COM I 2 3 4 5 Room name Room height Room dimensions Room anaa AIC 0 It 9.0 ft heaVbDol 12.0 f? 3D x 4.0 It WIC 6.0 ft 9.0 R hwVcDd 30.0 IF 5.0 x 6.0 It TY Construction number J-value (BtuhAF-*q Or HTM (13tuhfin Area OF) or permeter (ft) Load (BIuh) Areei or permfeeIr (ft) Load (Btuh) Heat cool Gross NOS Heat cool Gross MRS Heat cool 6 1� y --G 13A;12-1,m A-clonn- 3A-1Z5oca -13A:125� IA-dom 1100 — 13A-125= 1A,1= 11DO .16B-36k. - - - - -- - 22A-tDl_ 6.065 -:1270 0.065 1270 0.390 O.D65 1.270 0.390 0.032 __0.9-89 ne ne. w -EW sw sw mv mv w- -1,82 35.56 1.82 U32 35.56 - 10.92 132 35.56 10.92 - --0.90 _27.69 -078 �o.�7 3 0.78 ---Cf.78 53D1 10.34 0.78 70.43 10.34 --UO 0.00 0 -0 0 -0 0 0 0 _--12 _-12 0 0 ----0 0 -.0 0 0 0 -:-=-1 2 0 0 -0 0 0 54 ­0 0 -0 0 0 0 =730 ___30 ­0 54 -----o 0 -0 0 0 0 -��-30 6 . ..... 0 98 ----0 0 0 0 0 0 ---27 166 0 ------42 --o 0 -.0 0 0 a ------48 a w IF —0-- 0 -0 0 0 __O — 11 --0 0 -0 0 0 0 �--19 0 —0 -------- -- -3 6 C) AEC �on 0 Emelopelosstaln 11 19 291 89 12 a) Infitatm b) Rcornventilatm 0 0 0 0 96 0 26 0 13 Internal gaim Occupants@ 230 ApplianwElother 0 0 0 0 0 0 Subtotal Qinw6to 13) 11 19 3117 115 14 1151 Lesse4amalload Lesstansfer Redistdbution Subtotal Ductloads 250% 37%1 0 0 -11 0 0 0 0 -19 0 0 25-1. 37% 1 0 0 4 392 96 0 0 8 123 46 Total room load Airrecldred(cim) 0 0 0 0 1 1 488 8 169 10 Calculatons approved byACCA to meet all requirements of Manual J 8th Ed. Pjgtt-SU�@Uri�M]201919.OJDTRSU08101 2019-A-261"528 -.�ft�W09USoftHVACiPATTERSONRESlOt4CE.rW Calc=MJO FrontDoorfaces:S Page 6 wrightsofte Duct System Summary Job: Date: Entire House By,. QUICK CALCS, INC. 317 ST LUCE LANE. FORTMERCE. FL34946 Phone: 772-466-6799 E�g:QUICKCALCS@AOL.COM in Project Information I For. PATTERSON RESIDENE 191 SE EL SITO CT., PORT STLUCIE, FL External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H20 0.28 in H20 0.22 in H20 0.110 /0.110 in H20 0.090 in/10aft 233 cfm 115 Cooling 0.50 in H20 0.28 in H20 0.22 in H20 0.110/0.110 in H20 0.080 in/100ft 787 clim I Supply Branch Detail Table -I Name Design (Btuh) Htg (Cfm) Clg � (clinn) Design FIR Diam (in) HxW Ci n) Duct Mat Actual Ln (ft) Ftg.Eqv Ln (ft) Trunk BEDROOM2 c 2898 54 164 0.080 7.0 ox 0 \AFx 10.2 70.0 KIFFCHEN c 4566 46 258 0.080 &0 OX0 \AFx 24.7 90.0 sti LIVINGA)INNG c 2359 37 133 0.080 i.0 Ox 0 \/IFx 15.5 90.0 sti LIVINGOININC-A c 2359 37 133 0.080 7.0 ox 0 MFx 20.9 90.0 sti M BATH G 223 9 13 0.080 4.0 OX0 \A Fx 10.6 70.0 MASTERBEDROOM c 1019 34 58 0.080 0 MFx 6.1 70.0 PWDR�A c 79 1 4 0.080 4.0 OX0 MFx 5.0 70.0 URLITY c 126 1 7 0.080 4.0 OX0 \A Fx 7.0 70.0 WIG 0 169 81 10 0.080 4.0 OxO \AFx 3.6 70.0 WIC2 c 132 1 7 7 0.080 4.0 0XI0 \AFx 1 6.7 1 70.0 1 1 Supply Trunk Detail Table I Name Trunk Type Flt9 (101m) -Fm) FDesign IT FR Veloc 00m) Diam (in) HxW (in) Duct Material Trunk sti PeakAVF 119 524 1 0.080 668 12.0 0 x 0 VinlFlx Return Branch Detail Table I Name Grille Size(in) Htg (Cfm) Cig (Glirn) TEL (ft) Design FIR Meloc 00m) Diam (in) HxW (in) Slud/Joist Opening (in) Duct Mal nk rbl OX0 233 787 0 0 01 0 Ox 0 1 \AFX BakWarm vabues ham been manuafly ovenfdden Wrightsaft' 2019,M-2611.-0539 Rgft-Suleg Uriversal 2019 19.0.07 RSU081 01 Page 1 A= o�M\WhgttwftWACPATrERSONRESIDNCE.n4) CO,=MJ8 Fr,11),,rfacev S SCANNal Sheetl BY kaolocounty WNER: DAVID M. PATTERSON DDRESS: 191 S.E. EL SITO COURT, PORT ST.LUCIE, FL 34983 ERMIT #: 1908-0124 COMMENTS DATED: 819/2019 MARK: ITE771� I SHEET RESPONSE Plan Reviewer: IPLANS EXAMINER REVIEWER: DEBBIE ISENHOUR PLAN REVIEW COMMENTS & RESPONSE: ITEM: REV# SHEET RESPONSE 1,2,3,&4 1 S2.0 UPDATED ITEMS TO REFLECT IMPACT COMPLIANCE 5 2 S2.0 REWORKED PRODUCT APPROVAL TO REFLECT CHANGES TO COMPLY WITH IMPACT. 6 3 S2.0 REWORKED WINDLOAD COMPLIANCE FORM TO LATEST ISSUE 7 4 E1,0 NOT REQUIRED (VERIFIED W/DEBBIE) 8 5 S2.0 PROVIDED FOR ATTIC ACCESS 9 6 S2.0 UPDATED ENGINEERING DATA'NEC'TO 2014 ISSUE .Plan Reviewer, PLAN REVIEW COMMENTS & RESPONSE: ITEM: REV# SHEET RESPONSE AUG 14 20jq �T. Lucie County, Permitting. REVIEWED FOR CODE COMPLIAN CE, ST. LUCIE COUN'2"" Rocc Page 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: PATTERSON RESIDENCE Builder Name: Street: 191 SE EL SITO COURT PermitOffice: ST.LUCIECOUNTY City, State, Zip: PORT ST.LUCIE, FL, Permit Number. Omer: DAVID PATTERSON Jurisdiction: 0 W Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirement a The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doom to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior wells shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per Inch minimum. Exterior thermal envelope insulation for finamed walls shall be installed in substantial contact and continuous alignment With the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above­gamge subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace— Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall wirina Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall REVIEWE FOR be sealed to the sub -floor or drywall. C.0[)E- GO MP WAN CE Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. ST. % LUCIE COUNTY L I Caulking or other adhesive sealants shall not be used to fill voids between fire sodnkler cover plates and walls or ce I nos I a. in addition, inspection of iog waiis snail De in accordance with the provisions of I(X-4130. 7126/2019 11:03 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1