HomeMy WebLinkAboutENERGY EFFICIENCY CODEn 06 01" 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CALLAHAN RESIDEW
E MLA_c1vl;�
3uilder Name: MATHEW CALLAHAN
SCANNED
Street: 504 E. MIDWAY RD.
AUG 0 8 2019
�ermit Office: ST. LUCIE COUNTY
BY
G.ity, State, Zip: PORT ST. LUCIE, FL,
Dermit Number:
Owner: MATHEW CALLAHAN
Jurisdiction:
St.Luc7ieC0fl11tV
Design Location: FL, Fort Pierce
ST. Lucie County, Permitting 'ounty: St. Lucie (Florida Climate Zone 2 )
1. N ew construction or existing New (From Plans)
9. Wall Types (2277.0 sqft.)
Insulation Area
'
'2�-Single family or multiple family Single-family
a. Frame - Wood, Exterior
R=19.0 1533.00 ft2
b. Frame -Wood, Adjacent
R=1 1.0 576.00 ft2
3. Number of units, if multiple family I
c. Frame - Wood, Adjacent
R=1 9.0 168.00 ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2119.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2119.00 ft2
6. Conditioned floor area above grade (W) 2119
b. N/A
R= ft2
Conditioned floor area below grade (M) 0
C, N/A
R= ft2
11. Ducts
R fJ2
7. Windows(200.0 sqft.) Description Area
a. Sup: Affic, Ret: Attic, AH: LAUNDRY
6 226
a. U-Factor* SgI, U=0.31 I 19.00 fJ2
SHGC: SHGC=0.17
b. U-Factor: SgI, U=0.31 81.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.19
a. Central Unit
36.2 SEER:17.00
c. U-Factor: NIA ft.
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: NIA ftz
a. Electric Strip Heat
27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 5.400 ft.
Area Weighted Average SHGC: 0.178
14. Hot water systems
a. Propane Tankless
Cap: I gallons
8. FloorTypes (2119.0 sqft.) Insulation Area
EF: 0.600
a. Slab -On -Grade Edge Insulation R=0.0 2119.00 ft2
b. Conservation features
b. N/A R= fJ2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.094 Total Proposed Modified Loads: 58.51
PASS
Total Baseline
Loads: 61.83
1 hereby certify that the plans and specifications covered by
Review of the plans and
VUE S7,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREP D "Y:
Before construction is completed
D :4m
this building will be inspected for
compliance with Section 553.908
0
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
Q0 WV,
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
-.Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
8/812019 2:25 PM EnergyGaugeV USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page I of 6
I
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
CALLAHAN RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2119
Lot #
Owner Name:
MATHEW CALLAHAN
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
MATHEW CALLAHAN
Rotate Angle: 0
Street:
504 E. MIDWAY RD.
Permit Office:
ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
jurisdiction:
Whole House Fan: No
City, State,
Zip:
PORT ST. LUCIE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
'Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5%
2.5%
Winter
Summer Degree Days Moisture
Range
FL,
Fort Pierce FL—VERO_BEACH MUNI 39
90
70
75
299
62
Low
13LOCKS
Number
Name
Area
Volume
I
Entire House
2119
20703
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
I
BEDROOM 3
210
1890 No
1
1
1
Yes
Yes
Yes
2
SATH3
50
450 No
0
1
Yes
Yes
Yes
3
BATH 2
55
495 No
0
1
Yes
Yes
Yes
4
BEDROOM 2
225
2026 No
1
1
1
Yes
Yes
Yes
6
HALL
40
360 No
0
1
No
Yes
Yes
6
GREKIROOM
430
3870 No
4
1
Yes
Yes
Yes
7
DINING
168
1512 No
0
1
Yes
Yes
Yes
8
KITCHEN
182
1638 No
2
1
Yes
Yes
Yes
9
LAUNDRY
150
1350 No
0
1
Yes
Yes
Yes
10
1/2 BATH
25
225 No
0
1
No
Yes
Yes
11
WIC.
128
1536 No
0
1
No
Yes
Yes
12
TOILET
36
432 No
0
1
No
Yes
Yes
13
MASTER BEDROO
236
2832 No
0
1
1
Yes
Yes
Yes
14
WIC
36
432 No
0
1
Yes
Yes
Yes
15
MASTER BATH
108
1296 No
0
1
Yes
Yes
Yes
16
POWDER
40
360 No
0
1
Yes
Yes
Yes
FLOORS
V #
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
I Slab -On -Grade Edge Insulatio
BEDROOM 3 29 ft 0
210 ft2
0 1
0
2 S;ab-On-Grade Edge Insulatio
BATH3
6ft 0
55 f12
0 1
0
8/8/2019 2:25 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
\V7�#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
3 Slab -On -Grade Edge Insulatio
BATH 2
5 ft
0
50 ft2
0
1 0
4SIab-On-Grade Edge Insulatio
BEDROOM 2
36 ft
0
225 ft2
----
0
1 0
5 Slab -On -Grade Edge Insulatio
HALL
1 ft
0
40 ft2
----
0
1 0
6Slab-On-Grade Edge Insulatio
GREATROOM
19 ft
0
430 ft2
----
0
1 0
7Slab-On-Grade Edge Insulatio
DINING
12 ft
0
168 ft2
----
0
1 0
8 Slab -On -Grade Edge Insulatio
KITCHEN
13 ft
0
182 ft2
----
0
1 0
9Slab-On-Grade Edge Insulatio
LAUNDRY
loft
0
150 ft2
----
0
1 0
10SIab-On-Grade Edge Insulatio
112 BATH
1 ft
0
25 ft2
0
1 0
1 ISIab-On-Grade Edge Insulatio
WIC.
1 ft
0
128 ft2
0
1 0
12SIab-On-Grade Edge Insulatio
TOILET
1 ft
0
36 ft2
0
1 0
13SIab-On-Grade Edge Insulatio
MASTER BEDRO
16 ft
0
236 ft2
----
0
1 0
14SIab-On-Grade Edge Insulatio
WIC
6ft
0
36 ft2
----
0
1 0
15SIab-On-Grade Edge Insulatio
MASTER BATH
6ft
0
108 ft2
----
0
1 0
16S[ab-On-Grade Edge Insulatio
POWDER
5 ft
0
40 ft2
0
1 0
ROOF
V
Roof
Gable
Roof
Rad
Solar SA Emilt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2233 ft2
0 ft2
Light
N
0.6 No 0.9
No
20
18.4
ATTIC
V#
Type
Ventilation
Vent Ratio (I
in)
Area
REIS IRCC
I Full attic
Unvented
0
2119 ft2
N N
8/812019 2:25 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FIaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
-7v-#
CEILING
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
BEDROOM 3
0
Blown
210 f12
0.1
Wood
2
Under Attic (Unvented)
BATH 3
0
Blown
50 f12
0.1
Wood
3
Under Attic (Unvented)
BATH 2
0
Blown
56 f12
0.1
Wood
4
Under Attic (Unvented)
BEDROOM 2
0
Blown
225 ft2
0.1
Wood
5
UnderAttic (Unvented)
HALL
0
Blown
40 f12
0.1
Wood
6
UnderAttic (Unvented)
GREAT ROOM
0
Blown
430 f12
0.1
Wood
7
UnderAttic (Unvented)
DINING
0
Blown
168 ft2
0.1
Wood
8
Under Attic (Unvented)
KITCHEN
0
Blown
182 ft2
0.1
Wood
9
Under Attic (Unvented)
LAUNDRY
0
Blown
160 It,
0.1
Wood
10
Under Attic (Unvented)
1/2 BATH
0
Blown
25 It'
0.1
Wood
-
11
Under Attic (Unvented)
WIC.
0
Blown
128 ft2
0.1
Wood
12
Under Attic (Unvented)
TOILET
0
Blown
36 ft'
0.1
Wood
13
Under Attic (Unvented)
MASTER BEDRO
0
Blown
236 ft'
0.1
Wood
14
Under Attic (Unvented)
WIC
0
Blown
36 f:2
0.1
Wood
15
Under Attic (Unvented)
MASTER BATH
0
Blown
108 ft2
0.1
Wood
-
16
Under Attic (Unvented)
POWDER
0
Blown
40 1`1:2
0.1
Wood
WALLS
V ft
Ornt
Adjacent
Tn AA/nil Type
Cavity
Space P-VAI"A
Width
Et in
Height
Et In
Arpn
Sheathing Framing
R-\fnlprp Frprfinn
Solar
Ahqnr
Below
rrPrIp%
- 1
S
Exterior Frame - Wood
BEDROOM 3
19
14
0 9
0
126.0 ft2
0
0.25
0.5
0
-2
W
Exterior Frame - Wood
BEDROOM 3
19
15
0 9
0
135.0 ft2
0
0.25
0.5
0
- 3
S
Exterior Frame - Wood
BATH 3
19
5
0 9
0
45.0 ft-
0
0.25
0.5
0
_ 4
S
Exterior Frame - Wood
BATH 2
19
5
0 9
0
45.0 ft2
0
0.25
0.5
0
-5
N
Exterior Frame - Wood
BEDROOM 2
19
5
0 9
0
45.0 ft2
0
0.25
0.5
0
-6
E
Exterior Frame - Wood
BEDROOM 2
19
15
0 9
0
135.0 ft2
0
0.25
0.5
0
-7
S
Exterior Frame - Wood
BEDROOM 2
19
15
0 9
0
135.0 ft2
0
0.25
0.5
0
-8
E
Exterior Frame - Wood
GREAT ROO
19
19
0 9
0
171.0 f:2
0
0.25
0.5
0
- 9
W
Exterior Frame - Wood
DINING
19
12
0 9
0
108.0 f:2
0
0.26
0.5
0
10
W
Exterior Frame - Wood
KITCHEN
19
13
0 9
0
117.0 f:2
0
0.25
0.5
0
11
E
Exterior Frame - Wood
LAUNDRY
19
10
0 9
0
90.0 f:2
0
0.25
0.5
0
12
W
Exterior Frame - Wood
MASTER BE
19
16
0 12
0
192.0ft2
0
0.25
0.5
0
13
W
Exterior Frame - Wood
WIC
19
6
0 12
0
72.0 ft2
0
0.25
0.5
0
14
W
Exterior Frame - Wood
MASTER BA
19
6
0 12
0
72.0 112
0
0.25
0.5
0
15
W
Exterior Frame - Wood
POWDER
19
5
0 9
0
45.0 ft2
0
0.25
0.5
0
16
N
Garage Frame - Wood
WIC.
19
14
12
168.0 ftz
0
0.25
0.600000
0
17
N
Garage Frame - Wood
POWDER
11
48
12
576.0 it2
0
0.25
0.600000
0
8/812019 2:25 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V/ #
Wall
Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1
2
3
4
5
6
7
8
9
10
11
W 2 Vinyl
S 3 Vinyl
S 4 Vinyl
E 6 Vinyl
E 8 Vinyl
E 8 Vinyl
W 9 Vinyl
W 10 Vinyl
E 11 Vinyl
W 12 Vinyl
W 14 Vinyl
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.31 0.17 N 15.0 ft2 2 ft 0 in
0.31 0.17 N 6.0 ft2 2 ft 0 in
0.31 0.17 N 6.0 ft2 2 ft 0 in
0.31 0.17 N 15�O W 2 ft 0 in
0.31 0.19 N 40.0 ft2 5 ft 0 in
0.31 0.17 N 20.0 ft' 5 ft 0 in
0.31 0.19 N 41.0 ft2 12 ft 0 in
0.31 0.17 N 9.0 ft2 12 ft 0 in
0.31 0.17 N 9.0 ft2 2 ft 0 in
0.31 0.17 N 30.0 ft2 2 ft 0 in
0.31 0.17 N 9.0 ft2 2 ft 0 in
1 ft 4 in
1 ft 4 in
1 ft4in
1 ft4 in
1 ft 4 in
1 ft4 in
1 ft4 in
1 It 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
1200 ft-
1200 fl:2
64 ft 8 ft
1
INFILTRATION
Scope
Method
SLA
CFM 50 ELA EqLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000435
2415.4 132.6 249.37 .1631
7
HEATING SYSTEM
y #
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
CORI 27 kBtu/hr
1
sys#1
COOLING SYSTEM
y #
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
I
Central Unit/
Split
SEER: 17 36.2 kBtu/hr
cfm
0.7 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1
Propane
Tankless
Garage
0.6 1 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
7-=FSEC
Carl # Company Name
System Model # Collector Model #
Collector
Area
Storage
Volume FEF
None None
ft2
8/812019 2:25 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
Supply
Return --
Air
CFM 25
CFM26
HVAC #
V Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic 6
225 W
Attic
65 ft2
Prop. Leak Free
LAUNDRY
— chm
63.6 cfm 0.03
0.50
1 1
TEMPERATURES
Progrannable Thermostat: Y
Ceiling Fans:
Co ling Jan Feb
0 rg Ja
Heat; n Feb
Mar
M ar
A pr
Apr
M:y
IM y
n
r� Jun
X Jul
Jul
I
Aut 9
Aug
S
rl S:p
Oct
�j Oct
N ov
Nov
Dec
Dec
Venting Jan Feb
X Mar
Apr
May
Jun
Jul
Aug
Sep
Oct X
X1
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
so 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (VVD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
(WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbslsq.ft.
0 ft2
0 ft
0.3
BEDROOM 3
Default(8 lbs/scift.
ft2
ft
0.3
BATH 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 lbs/sq.ft.
ft.
ft
0.3
GREAT ROOM
Default(8 [bs/sq.ft.
ft�
ft
0.3
DINING
Default(8 lbs/sq.ft-
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
1/2 BATH
Default(8 lbs/sq.ft.
ft,
ft
0.3
WIC.
Default(8 lbs/sq.ft.
ft,
ft
0.3
TOILET
Default(8 lbs/sq.ft.
112
ft
0.3
MASTER BEDROO
Defau[t(8 lbs/sq.ft.
ft2
ft
0.3
Wic
Default(8 Ibs1sq.ft.
ft2
ft
0.3
MASTER BATH
ftz
ft
0.3
POWDER
8/8/2019 2:25 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CALLAHAN RESIDENCE BuilderName: MATHEWCALLAHAN
Street: 504 E. MIDWAY RD. Permit Office: ST. LUCIE COUNTY
City, State, Zip: PORT ST. LUCIE, FL, Permit Number:
Owner MATHEW CALLAHAN Jurisdiction:
w
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
6eiling/aftic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doom
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
F, r sealing shall be provided between the garage and conditioned spac
I ? S.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
I
Recessed light fixtures installed in the building
shall be sealed to the drywali.
thermal envelope shall be air tight and IG rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exteriorwalls, or insulation that on
installation readily conforms to available space shall
QXtAnd hphind nining Pnd wirina
Showeritub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxes or air -sealed boxes shall be installed.
HVAC register
oots that penetrate building thermal envelope shall
sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
i,�..�fir..,inkl Q2V2L2jajUAI1d I &jing
I
a. In addition, inspection of log walls shall in prov of ICC-400.
8/8/2019 2:25 PM EnergyGauge(D USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX- = 95
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1 . New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R -
6.0
2. Single-family or multiple -family
2. Single-fami
y
b) Return ducts R
6.0
c) AHU location LAUNDRY
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity---L6.2
a) Split system SEER
17.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
2119
d) Room unit/PTAC EER
a) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.310
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.178
14. Heating system: Capacity__-27.0
c) Area
7c.
200.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF_
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
a) Gas furnace, LPG AFUE
1) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.-
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9C.-
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
0.60
A. Exterior:
d) Solar system with tank EF
1. Wood frame (insulation R-value)
1 OA1.
19.0
e) Dedicated heat pump with tank EF
2. Masonry (insulation R-value)
1OA2.
0 Heat recovery unit HeatRecO/o
B. Adjacent:
g) Other
1. Wood frame (insulation R-value)
1OB1.
varies
2. Masonry (Insulation R-value)
1OB2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
Ila.
0.0
b) Cross ventilation
No
b) Single assembly
Ilb.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
Ild.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 504 E. MIDWAY RD. City/FLZip: PORTST.LUCIE.FL
818/2019 2:25:47 PM EnergyGaugelD USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
wrightsofte Prqject Summary Job:
Data:
Entire House By.
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE. FL34946 Phore: 772-466-6799 Ewll:QUICKr-ALGS@AOL.COM
Promect Information
For. CALLAHAN RESIDENCE
504 E. MIDWAY RD., PORT ST. LUCIE, FL
Notes:
Design Informatio
Weather Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
42
OF
Outside db
90
OF
Insidedb
70
OF
Inside db
75
OF
Design TO
28
OF
Design TO
15
OF
Dail
R20'enCmidity
M
50
%
Moisture difference
61
grAb
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure
16662
Btuh
Structure
16619
Btuh
Ducts
4057
Btuh
Ducts
3121
Btuh
Central vent (0 cfirn)
0
Btuh
Central vent (0 clim)
0
Btuh
(none)
(none)
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
20719
Btuh
Use manufacturer's data
n
Rate/sMin it 1'
musitler
0.95
Infiltration
Equipmenj sen e load
18753
Btuh
Method
Simplified
Latent Cooling Equipment
Load Sizing
Construction quality
Amerage
Fireplaces
0
Structure
3911
Btuh
Ducts
2430
Btuh
Central vent (0 chm)
0
Btuh
Area
Heartin
Cooli
(pone)
(fe)
2121
21N
Equipment latent load
6341
Btuh
Molume (ft)
20748
20748
Archarixest'hour
EquivA
0.32
0.16
Equipment Total Load (Sen+Lat)
25094
Bun
(cftn)
Ill
55
Req. total capacity at 0.70 SHR
2.2
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Trane
Trade
Trade TRANE
Model
Cond 4TTR7036Al
AHRI ref
Coil TEM6AOC36H31++TDR
AHRI ref 7947764
Efficipncy
I00AFUE
Efficiency 13.0 EER, 17 SEER
Heating input
3.6
kW
Sensiblecooling
25340
Btuh
Heating output
12144
Bbuh
Latentcooling
10860
Btuh
Temperature rise
50
OF
Total cooling
36200
Btuh
Actual air flow
221
chm
Actual airflow
1207
cfm
Air flow factor
0.011
cfim/Btuh
Airflowfactor
0.061
&n/Btuh
Starticloressure
0.50
in H20
Static pressure
0.50
in H20
Space thermostat
Load sensible heat ratio
0.76
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrllght��ft- 2019-Aug-08 1424:30
Righ-SL&OUriversal 2019 19.0.07 RSU081 01 Page I
o0=artSWri9I1Soft WACCALLAHAN RESIDENCEnp Cale = MJ8 Frort Door faces: S
wrightsoft, Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.,
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Emil; QUICKCALGS@AOL.COM
I
2
3
4
5
Rwm nanne
5posedwall
Rwm height
Rwm crimensims
Rwm aIea
EnImHoum
161.0 It
9.8 ft
2124.0 IF
SEDROOM3
29.0 It
9.0 ft heattoDd
15.0 x 14.0 It
210.0 W
Ty
Cw&ucUm
numbff
U-value
(BbAlle-T)
Or
HTM
(BtaW
Area (fl-)
� penmeler (ft)
Load
(Btuh)
Axea (f?)
or pennieter (11)
Load
(Btuh)
I Heat
C�d
Gnxs
NSS
Heat
cool
Gn�
N/P)S
Heat
CMI
6
-
1 1
W--
VN
12E-0sw
12E-Ow
IOB-v
4A5-2ob
4AS-20V
- 4A5-2ov
12E-Osi�
-4A5-2ob--
12E-09N
4A5-20b
4A5-20v
4A5-20V
4A5-20\d
22A:tq_____
7(j-6§3
0.068
0.600
0.560
0.470
0.470
O.D68
0.560
0.068
0.560
0.470
0.470
0.470
-A-41
408---
_0-gs91
--'n-
e
e
e
e
- a
si
-s-,-15.68
w
w
w
w
w
'
:. -fab
1.90
16.80
15.68
13.16
13.16
----1.90
1.90
1SB8
1316
13.16
13.16
--
-!.is
1.18
31.45
41.95
34.04
35.16
118
16.16
1.18
41.95
34.04
35.16
35.61
-
-4-5
396
41
15
9
20
741
is
18
so
41
311
2
1
1
1
----3S9
12
637
1
2
2
2
--,86
693
685
235
118
263
_188
1213
235
237
395
537
368
1283
629
306
703
--40:1
-_ISL4
754
629
613
1055
1453
--Z:-6
0
0
0
0
0
--'-f26---126---246--1Q
-_O
135
15
0
0
0
0
0
0
0
120
1
0
0
0
0
0
0
0
0
-0
228
235
0
0
0
0
0
0
0
0
-0
T-G
w
-F -
142
629
0
0
0
=Vff.
0
---1.59
-27.6-9.
--
- 1.3 I-
0.00
-:=Tf24
2124
-2124
----1-61
4458
2906
-0
_0
---210
210
_210
--.-2,9
=--�W
803
61
c) AED �rslon
519
155
Enxelopelossigaiin
13257
11867
1840
1363
12
a) Inilinaton
J) Rwm ventilation
3405
0
912
0
580
0
155
0
13
Intaml gains O=pants@ 230
Appliancesfoth�
8
1840
20DO
1
230
0
Subbta(llnes6b13)
16662
16619,
2419
1748
114
15
Lesse)dennal load
LeestransfLr
Recienbuton
Subbal
Ductloads
24%
19%
0
0
0
16662
4057
19%
0
0
9
2428
691
C'
0
7
1755
330
20719
221
3020
32
2085
127
Calculabonsa proved byACCAto meet all requirements of Manual J 8th Ed
�rlvft�t- 2019-ALIg-08 14:24:30
Pjgft-StiteOUriwrwl2Ol9l9.O.O7RSU08101 Page I
D�rts\W69ftwftHVAC\CALLARANRESIDENCEAp Calc=MJB Pmril3corfaces: S
wrightsoft' Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Emil: QUICKCALCS@AOL.COM
1
2
3
4
5
Room name
bposadval
Room height
Roam dimensions
Room area
RATH 3
5.0 R
9.0 11 heaVc0ol
11.0 x 5.0 ft
55.0 ft2
BATH 2
5.0 It
9.0 11 heaYcool
11.0 x 5.0 ft
55.0 fe
TY
Construdon
number
LI-value
Or
Area (fe)
or perimeter (ft)
Load
(Btuh)
Area (ff)
or perimeter (11)
Load
(Btuh)
G�
NIPJS
Heat
cool
Gross
NIP/S
Heat
cool
6
11
G
12E-6Eiv---
12E-0mv
10B-v
4AS-20b
4A!5-2�
4A5-2av
12E-CSAF
4A5-20b-.-
12E-Ow
4A5-2ob
4A5-20v
4A5-2ov
4A5-20W
i-6X19;6F
-0.068-n-
0.068
0.600
0.560
0.470
0.470
----0.068-s--
0.560
0.068
0.560
0.470
0.470
0.470
-6.408
0.989
a
a
a
a
e
-a-
w
w
w
w
w
1.�b.---1.18
1.90
16.80
15.68
13.16
13.16
---15.68
1.90
15.68
13.16
13.16
13.16
1.59
27.69
1.18
31A5
41.95
34D4
35.16
---l.-18
- 16.16
1.18
41.95
34.04
35.16
35.61
--1.37
0.00
--0
0
0
0
0
0
_7215
---6
0
0
0
0
0
55
--_0
0
0
0
0
0
39
---6
0
0
0
0
0
0
0
0
0
0
0
'74
----94
0
0
0
0
0
0
0
0
0
0
46
97
0
0
0
0
0
__o
0
0
0
0
0
-----45'---39
----6
0
0
0
0
0
____o
0
0
0
0
0
a
a
0
0
0
-74
---94
0
0
0
0
0
7�0
0
0
0
0
0
46
--.--.97.
0
0
0
0
0
---75-
0
---6
0
0
0
0
0
C
F
5
-8 7,
138
-75
0
�-55
55
!---65
5
:!---87.
138
-----------
- ---
-- - ----
61
C) AED e=nsiorl
-23
-23
1
Envelope losstgain
3941
195
394
195
121
a) Irviltration
b) Rcom%enfilation
100
a
27
0
100
0
27
0
131
Internal gal. O=pants@ 230
Applianceslother
0
0
0
0
0
0
Sublatal (11nes 6 to 13)
494
222
494
222
14
15
Lessedernal load
Lesstransfer
Redishibutim
Subinial
DuctIcads
249/61
19%,
0
0
11
505,
123
0
0
9
231
431
24%
19%
0
0
11
505
123
0
0
9
231
43
ToW � load
Airrequired(dirn)
1
6281
7
2741
17
62,8
Z'74
7
Calculabons approved byACCAto meetall requirements of Manual J 8th Ed.
-fi- 2019-Aug-08 14:24:30
A& Pjgft-SUteGUriveM1201919.0.07RSL)08101 Page 2
o�erts�W6grtsoftWACCALLAHANRESIDENCE.rLp Cale-M,18 FrortDoorlaws:S
wrightsoft' Right-M Worksheet Job:
Entire House Date;
QUICK CALCS, INC. By:
317ST. LUCIE LANE, FORTPIERCE, FL34946 Phom:772-466-6799 Emil: QUICKCALCS@AOL.COM
1
2
3
4
5
Roon name
E)posed wall
Roon height
Roam dimensions
Rwmarea
BEDROOM2
35.0 It
9.0 It heaftol
15.0 x 15.0 ft
225.0 f?
HALL
0 It
9.0 ft heaVccol
4.0 x 10.0 It
40D ft2
TY
Consinucion
number
U-value
(BtuhW�F)
Or
HTIVI
(fthffl
Aiea OLI)
or perimeter (110
Load
(Btuh)
A� (fF)
a pefimeLr (it)
Load
(fth)
Heat
Cool
Gross
N/P/S
Heat
Cod
Gross
NRIS
Heat
Cool
6
-
1 1
VV
V
_G
12E-Ow
12E-Osw
IGB_v
4A5-2ob
4A5-2w
4A5-2ov
12E�Osw
4A5-2ob------
4A5-20b
4A5-2ov
4A5-20V
4A5-2o,4
2�-tpla
0.068
0.063
OMI)
0.560
0.470
0.470
- ---O.'C68
-0,560-S-15.68-16.16
0.068
0.560
0.470
OA70
0.470
e
e
e
e
e
-s-
w
w
w
w
w
-1 .90
1.90
16.80
15.68
13.16
13.16
1F90
1.90
15,68
13.16
13.16
13.16
_118
1.18
31A5
41.95
34.04
35.16
-- -1-113
1.18
41.95
34.04
35.16
35.61
_-45
135
0
15
0
0
----135
_O
0
0
0
0
0
120
0
1
0
0
--85
228
0
235
0
0
--257
----0
0
0
0
0
0
142
0
629
0
0
0
0
0
0
0
0
0
0
0
0
0
---.-0
0
0
0
0
0
---0
0
0
0
0
0
-lZ6
----o
0
0
0
0
0
225
35
--1-60
- --0
0
0
0
0
0
--0
--0---0
---o
0
0
0
0
0
=46
0
---,0
Q
0
0
0
0
0
�55
0
-10
0
0
0
0
0
==4-0
40
-0
0
0
0
0
0
0
N12E-Ow
F
0-40-8
0.989
27.69
---13-7.
0.00
----22-5-
225
=357.
969
=W-8
0
6
0) AED exrursion
-115
-5
Enve!ope loWgain
2132
1177
63
50
12
a) Inviltralion
b) Roornvenflaton
700
0
187
0
0
0
0
0
13
Internal gains: O=pants(g 230
Applianoes(other
1
230
0
01
01
0
Subtolal (Iines6 to 13)
2832
1594
63
50
14
115,
Lessextennalload
Leastransfer
Redislybution
Subbial
Ducticads
24%
19%
0
0
9
2841
692
0
0
7
1601
301
24%
190/0
0
0
-63
0
0
0
0
-50
0
0
TOW room load
Airrequired(cim)
3533
38
1902
116
0
0
0
0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-rl- 2019Aug-08 1424.30
Rgtt-SLiteSUri�rml20l9l9.0.07RSU08101 Page 3
ACCK o�erts�W(Igrd�fkHVAC\CALLAHANRESIDENCE.rtp Calc=MJ8 FrortDoorfacev. S
wrightsofV Right-M Worksheet Job:
Entire House DatD:
QUICK CALCS, INC. By:
317 ST. LUCIE LANE, FORT PIERCE. FL 34946 Phone: 772-46"799 Emil: QUICKrALCS@AOL.COM
I
2
3
4
5
Room name
Dpi:iaadwall
Room height
Room dimensions
Room area
GREAT ROOM
19.0 It
9.0 It heat/aicil
1.0 x 430.0 it
430.0 T
DINING
1?0 ft
9.0 a heaVmol
120 x 14.0 It
168.0 ff
Ty
Construction
number
U-value
(Bbjh&�F)
Or
HTM
(Btuhd5
Area (M
o- perimeter (11)
LWd
(Bkjh)
Anea
or perimeter (fl)
Load
(Btuh)
Grms
N/PIS
Heat
cool
Gr=
N/Pro
Heat
cool
6
11
-W-
-12E-OSW-
12E-Ow
1OB-v
4A5-20b
4A5-20v
4A5-2m
12E-Osv� --- - ----
4A5-2ol)--
12r-Ow
4.A5-20b
4A5-2w
4A5-2civ
4A5-2md
16X19;6Fd
22A-sil
O.G66
0D38
0*600
OsI30
0.470
0.470
-0.068
----0.560
0.068
0.560
0.470
0.470
0.470
77-07468
0.989
-n
a
a
a
a
a
--a'
-a-
w
w
w
w
w
-� =
1.90
1.90
16.80
15.613
13.16
13.16
- 190
_j�.68
1.90
15.68
13.16
13.16
13.16
____2Z.69
1.18
1.18
31.45
41.95
34.04
35.16
- 116
16.16
1.18
41.95
34.04
35.16
35.61
-' --Y3-7
0.00
0
171
41
0
0
20
0
0
0
0
0
0
0
110
2
0
0
1
----o
---,o
0
0
0
0
0
::---43b
19
0
210
685
0
0
263
0
_____o
0
0
0
0
0
-----6s2
526
--o
130
1283
0
0
703
--- --o
-- --0
0
0
0
0
0
==598
0
0
0
0
0
0
0
- -'-o
--0
108
0
0
0
41
168
- ___0
0
0
0
0
0
--0
0
0
0
0
0
0
0
0
0
0
--o
--0
67
0
0
0
2
--0
- 0
128
0
0
0
537
---6
__-0
so
0
0
0
1453
.C-
F
�=4315
430
=fM-
12
--2b6
332
=f3id
0
61
c)AEDe=rsIcn
-194
514
Enwlcpe los§gain
2366
2511
1264
2276
12
a) Irraftration
b) R�venllaton
380
0
102
0
240
0
64
0
13
Internal gains 0=parr[S@ 230
Aolanoesfother
4
920
0
01
"1
0
Subbtal (Iines6 to 13)
2746
3532
1503
2341
14
15
Les;eAernal load
Lesitrarser
Recristributm
Sublimal
D=Ii:ads
24%
19%
0
0
23
2769
674
0
0
18
3550
667
24%
19%
0
0
0
1503
3%
0
0
0
2341
440
Total room lwd
Pirrequired(clim)
34,43
4217
258
1870
20
2780
170
Calculafions approved byACCA to meet all requirements of Manual J 8th Ed.
-rk- 2019-AL"B 14:24:30
A& Rigirt-StReOUri�i-sil 201919.0.07 RSU08101 Page4
c�rts\WHgNsoftHVAC\CALLAHANRESIDENCEnp Caic=MJB FrortDoorfams S
wrightsoft* Right-M) Worksheet Job:
Entire House Data:
QUICK CALCS, INC. By:
317 ST LUCE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 EMII:QUICKCALCS@AOL.COM
1
2
3
4
5
Room name
EVosedVval
Room height
Rcom dinnersons
Room area
)UrCHEN
13.0 It
9.0 It heaVood
13.0 x 14.0 It
182 0 ft�
LAUNDRY
10.0 ft
9.0 It heatficcol
10.0 x 15.0 ft
150.0 fe
TY
COneftdW
number
U-ValUe
(Btuhhe-9
Or
HTIVI
(Elbih/M
Area (M
a penmeter (ft)
Load
(Bluh)
Anaa (W)
or perimeter (11)
Load
(Bbih)
Heat
Cool
Gnoss
N/P/S
Heat
Cool
Gnoss
N/P/S
Heat
Cool
6
w
t--G
12E-Ow
2E
1 -OW
1013-v
4A5-20b
4A5-2ov
4A5-2ov
12E-Osd--
4A5-20b.-
12E-Ow
4A5-20b
4A5-20V
4A5-2w
4A5-2M
1GX1Gk0md
22A-tol
0.068
0.068
0.600
0.560
0.470
0.470
0,068
0.560
O.Ow
0.560
OA70
0.470
0.470
-OA-08
0.989
n
a
a
a
a
a
-a--
-.a.-
w
w
w
w
w
_Tgo
1.90
16.80
15.68
13.16
13.16
-- -1-.9-0
-. _15.68
1.90
15.68
13.16
13.16
13.16
-150
Z�zq
----1.1-8
1.18
31.45
41.95
34.04
35.16
_16.16
1.18
41.95
34.04
35.16
35.61
0.00
0
a
0
a
0
0
----0
____ _O
117
0
9
0
0
:��-Jsj
182
0
0
0
0
0
0
.----o
108
0
1
0
0
jtd
13
0
81
0
0
1
0
-0
154
0
0
118
0
96
0
0
306
0
-0
G
0
0
0
0
-- 0
_0
206
0
118
0
0
-::�289
360
-.0
0
0
0
0
0
-0
_O
128
0
306
0
0
_:7--7249
0
---G
90
0
0
9
0
0
0
0
0
0
=1 Co
150
0
0
0
0
0
:�150
10
0
0
0
0
0
277
--,--o
0
0
0
0
0
0
0
C
6
c) AED excursion
-146
-48
Em,elope loss/gain
973
537
787
559
12
a) Infftration
b) Rcomverrfilatlon
260
0
70
0
200
0
54
0
13
Inlarral gains Occupants@ 230
Appliancestother
2
460
2000
0
0
0
Subtotal (11nes6 to 13)
1233
3067
997
613
14
15
L�elwnal load
I-miransfer
Redishibuton
Subtotal
6u - �mds
Ductl ds
249/6
19%
0
0
0
1233
300
0
0
0
3067
576
J24-%/
19%
0
0
0
997
240
0
0
0
613
115
otal roorn load
T't'l to
T nbb�
Xr require d (cdfm)
1533
16
3643
223
1228
13
728
AR
Calculabons approved byACCAto meet all requirements of Manual J 8th Ed.
-F�F nriu��rL- 2019-Aig-08 1424:30
A%k Rigtt-SuteVUriverwl 2019 19.0.07 RSLJO8101 Page 5
...O�rWWrighWftKVAC�CALLAHANRESIDENCE.nip Calc=MJB FrontDoorfacesS
wrightsoft' Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST LUCIE LANE. POR`r PIERCE, FL34946 Prone: 772�66-6799 Emil: QUICKCALrS@AOL.COM
I
2
3
4
5
Room name
E)posBd well
Room height
Roorn dimensions
Room area
1/2 BATH
0 It
9.0 It heatbool
5.0 x 5.0 it
25.0 f12
wC.
0 ft
12.0 It heaVocol
1.0 x 128.0 ft
128.0 T
TY
Construdion
number
U-%due
(Btuhft�F)
or
HTM
(Btuhl"
Are, ("
or pen meter (il)
Lead
(Buh)
Area (fl?)
or perimeter (fo
Load
(Btuh)
Heat
I Cool
Gross
NIPIS
Heat
Cool
Gross
NIPIS
Heat
cool
6
W -
12E-Ow
12E-Ow
ics-V
4A5-2ob
4A5-2ov
4A5-2ov
12E-Ow
4A5-2ob
12E-Ow
4A5-2ob
4M-2ov
4M-2ov
4M�20\d
16M-Oind-
122A _tj
,0.068
0.068
0.6130
0.560
0.470
0,470
0.560
0.068
O�560
OA70
OA70
OA70
-OA08
----0.989-
_n
e
e
e
e
a
-6
--S-
w
w
w
w
w
1.90
1.90
16.80
15.68
13.16
13.16
1.90
15.68
1.90
ISM
13.16
13.16
13.16
9-
27.69
.18
1.18
31.45
41.95
34.04
35.16
---1-f8
- _16.16
1.18
41.95
34.04
35.16
35.61
_=j-.37
0.00
- ---d
0
0
0
0
0
b
----.--o
0
0
0
0
0
--- -
--25
- 25
0
0
0
0
0
-D
_O
0
0
0
0
0
---
----25
--o-
-- -
0
0
0
0
0
0
-0
0
0
0
0
0
0
40
- - 0
----
____.o
0
0
0
0
0
0
0
0
0
0
0
---347___
----0
--
__O
0
0
0
0
0
---- o
_0
0
0
0
0
0
'128
128
-_O
0
0
0
0
0
---o
---,o
0
0
0
0
0
---0
0
0
0
0
0
-----,-0
0
0
0
0
0
-'0
0
T-G
C
F
-o
--o
0
0
0
0
0
0
0
0
0
0
=7 s
---- 0
--DY8
0
zo
-0
61
C)AEDemurson
-3
-17
Envelope los9gain
40
31
203
158
12
a) Infilvalion
b) Room ventilaton
0
0
0
0
0
0
0
0
13
Internal gains O=pants@ 230
Appliancesfuther
0
0
0
01
0
0
Sublotal Olnies 6 to 13)
40
31
203
158
14
15
Lesse)derralload
Leastransfer
Redistribution
subtotal
Ductloads
24%
19%1
0
0
0
40
10
0
0
0
31
6
249/6
19%
Total room two
Arrequired(dim)
I
1
49
1
37
2
Calculations approved bVACCAb meet all requirements of Manual J 8th Ed.
-Fk- 2019-Aug-08 142430
RiOt-SuilegUniversal 201919.0.07 RSU08101 Page 6
C�rts�Wri9ftWftWACCALLARANRESIDENCEiLp Calc=MJB FrortDoorfacev. S
wrightsoft' Right-J@Worksheet Job;
Entire House Date:
QUICK CALCS, INC. By:
317 ST LUCIE LANE, FORT PIERCE, FL34946 Phore: 772-466-6799 Emil: QUICKCALCS@AOL.COM
1
2
3
4
5
Room name
EVoschwall
Room height
Room dimerisons
Room area
TOILET
0 ft
12.0 ft hmVcool
6.0 x 6.0 ft
36.0 tt2
MASTER BEDROOM
16.0 It
izo It heaVood
1.0 x 236.0 It
236.0 f?
TY
Constructim
number
U-wlue
(BtuhAF-9
Or
HTM
(BbihAn
Area (M
or perimeter (ft)
Load
(Btuh)
Area (M
or perimeter (ft)
Lead
(Btuh)
Head
Cool
G.
N/PIS
Heat
Cc.]
G.
NIP/S
Halt
Cool
6
VV 12E-Ow
12E
10B-v
4A5-20b
4A5-2ov
4A5-2ov
12E-Ow
T—G 4A5-,20b
12E-0sw
4A5-20b
4A5-Zov
4A5-20V
4A5-20\d
C.
IF 22A-tIol
O�068
0.068
OBOO
0.560
0A70
OA70
-0068
0.560
0.068
0.560
0.470
0.470
0.470
0.408
0.989
-n
e
e
e
e
a
-S-
--a-
w
w
w
w
w
1,90
1,90
16.80
15.68
13.16
13.16
1-90
15.63
1.90
15,68
13.16
1316
13,16
Z7.69
-
1.18
1.18
31.45
41.95
34.04
35.16
-1-.18:
16.16
1.18
41.95
34.04
3516
SE.61
_IX
0.00
'0
0
0
0
0
0
-0
---- -- 0
0
0
0
0
0
36
36
0
0
0
0
0
0
-0
---0
0
0
0
0
0
---36
0
0
0
0
0
0
0
-----0
-0
0
0
0
0
0
57
0
_'__0
0
0
0
0
0
---0
---0
0
0
0
0
0
0
0
--0
192
0
0
30
.236
236
------ 0
0
0
0
0
0
---0
— _0
162
0
0
2
-- ----
—0
0
0
0
0
0
----0
---0
308
0
0
395
0
---o
0
0
0
0
0
--- -6
__0
0
0
0
0
0
------- �;9
0
192
0
0
1055
323
0
--2W
16
374-
443
61
c) AED eiicursion
�5
354
Envelope lossfgain
57
45
1521
1923
12
a) Irriltration
b) Room ventilation
0
0
0
0
428
0
114
0
13
Ill gaim Ooo�pane;@ 230
Appliances/other
0
0
01
0
0
0.
Subtotal (linesi to 13)
57
45
1947
2037
14
15
Less;eAarnalload
Lessbansfar
Rediscibucon
Subtotal
DuCtIcads
24%
1 19%1
0
0
0
57
14
0
0
0
45
8
24%
19%
0
0
0
1947
474
0
0
0
2037
383
TOW room lead
Airrequired(o5m)
1
71
1
53
3
2421
26
2420
148
Calculations approved bVACCA to meet all requirements of Manual J 8th Ed.
--- -4&- 2019-ALU-08 14:24 30
AC-Ck Rglit-StAteGUniversat 2019 19.0.07 RSU081 01 Page7
..�c�rts�W(igitsoftHVACCALLAFiANRESIDENCE.rtp Calc=MJ8 FrontDoorfaces S
wrightsoft* Right-JO Worksheet Job:
Entire House Dabe:
QUICK CALCS, INC. By-.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 PWW: 772466-6799 Emil: QUICKCALCS@AOL.COM
1
2
3
4
5
Room name
EVoa�d ��Il
Room height
Room dimendons
Room wea
wic
6.0 it
12.0 ft heaVODDI
6.0 x 6.0 ft
36.0 ff
WSTER RATH
6.0 ft
12.0 it hWV=l
1.0 x 108.0 it
108D IF
Ty
Constructon
number
U-Wue
(Stuhlit--F)
Or
HTIM
atuhAt2)
Area (f?)
or Perimeter (ft)
Load
(BIUh)
Area (M
or perimeter (M
Load
(1311uh)
Heat
Cool
G.
N/P/S
Heat
Cool
Gross
N)P)S
Heat
cool
6
1
W 12E-OW
N 2E
I -0w
1013-V
4A5-20b
4A5-2ov
4A5-2�
12E-0sw
4A5-20b,,-
12E-0�
4A5-20b
4A5-20v
4A5-20V
4A5-20W
.c I 16M`uorina --- 7�-
F 122A-Ml
0.0as
0.068
DBOD
0.560
0.470
0.470
0.668
_0,560
0.068
0Z50
0.470
0A70
0A70
.0.989
9
a
e
a
a
-i-
a-
w
w
w
w
w
1.90
16.80
15.68
13.16
13.16
'- -1.-90
_11*18
1.90
15.68
13.16
13.16
13.16
-f.69
Z7.69
1.18
31.45
41.95
34.04
35.16
- 1."18
_,6,115
1.18
41.95
34.04
35.16
35.61
2i7
0
0
0
0
0
_0
_0
72
0
0
0
0
--,--36
36
0
0
0
0
0
0
0
0
0
0
-----0
o
137
0
0
0
0
l66
0
0
0
0
0
---0
_o
0
0
0
0
0
72
0
9
0
0
108
0
0
0
0
0
--b
__0
63
0
1
0
0
=68
- _-6
___0
0
0
0
0
0
'__0
120
0
Ila
0
0
_1_66
0
0
0
0
0
72
0
0
0
6�
85
0
0
0
0
-0
_-0
75
0
306
0
0
_-O
61
C) AED emmw
-17
106
Envelopelossigain
360
118
576
&94
12
a) ImItration
b) Rwmwrrblabon
160
0
43
0
160
0
43
0
13
Internal gaim O=panb@ 230
Appliances(other
0
01
0
0
0
0
Subtotal (Iines6 to 13)
520
ISO
736
6T7
14
15
Lessodernalload
Lessbansfer
Redishibuton
Sublotal
Ductloads
24%
19%
0
0
0
520
IZ7
0
0
0
160
30
24%
19%
0
0
0
736
1791
0
0
0
677
lZ7
r[
Total noom IlMd
(ohn)
647
7
191
1
12
9151
to
8 04
4 a
Calrulations approved byACCAtc) meet ail requirements of Manual J 8th Ed
41- 2019-AL"8 1424:30
Aft, RgIj-sLtta@Urnersa1 2019 19.0.07 RSU081 01 Page 8
�.�0=erds\W69ftwftHVACrALLARANRESIDENCE.rw Calc=MJ8 FrontDoorfaces: S
wrightsoft* Right-M) Worksheet Job:
Date:
Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE. FORT PIERCE, FL34946 Phone: 772-466-6799 Emil: QUICKCALCS@,AOL.COM
1
2
3
4
5
Room name
E;Aposad wall
Room height
Room dimensions
Room area
POWDER
5.0 It
9D ft heaVood
5.0 x &0 it
40.0 ft2
Ty
Constructcn
number
U-value
(BtuhV-'F)
Or
HTM
(Ettuhrfl
Area (fF)
or perimeter (ft)
Load
(Btuh)
Area
or permeter
Load
H..t
Cool
Gross
N/PIS
Heat
Coo]
Gross,
N/R/S
Halt
Cool
6
1.
1
YV 12E-0sw
N 12E-Ow
10B-v
4A5-2ob
4A5-2ov
4A5-2av
12E-0sw
-T--G 4A5-2.b-
4A5-2ob
4A5-20V
'N 12E-0sw
4A5-20v
A45-2%d
c i6xie-anna-
F 22A-tol
0.068
0.068
0,600
0.560
0.470
0.470
0.ods
0,161
0.068
0.560
0.470
0.470
0.470
-024-0-8
0989
e
e
e
e
a
-s
-a-
w
w
w
w
vi
im
1.90
16.80
15.68
13.16
13A 6
--- 1.90
11,68
1.90
15.68
13.16
1316
13.16
�5§
Z7.69
--f. 18
1.18
31.45
41.95
34.04
35.16
--1.18
16,11;
1.18
41.95
34.04
35.16
35.61
f ---137
0.00
0
0
0
0
0
0
0
---0
45
0
0
0
0
"��-'---40
40
-0
0
0
0
0
_0
0
45
0
0
0
0
46
5
0
0
0
0
0
-0
0
0
86
0
0
0
0
-----63'
138
0
0
0
0
—0
--0
53
0
0
0
0
'------5-5
0
6
c) AEC .1sloh
-13
Enve1cpe loss/gain
2881
95
1
12
a) Inlitralion
b) Roommerflitation
100
0
Z7
0
13
Internet gaina O=pam@ 230
Applianceslother
0
0
0
Subbtal(lines;6to13)
388
122
14
15
Lesaeoemal load
Lesstransrer
Redistibubon
Subtotal
Ducticads
24%
19%
0
0
0
388
941
0
0
0
122
23
Total room load
Airrequired(crim)
482
r
145
9
Calrulatons approved byACCA to meet all requirements of Manual J 8th Ed.
-FW 2019-Aug-08 14:24:30
A& RigIt-SuteVUriversal 2019 19.0.07 RSU08101 Page 9
o�rds\W�giftoftHVAC\CALLAFiANRESIDENCE.rLp Caic=MJ8 FrordDoorftces: S
wrightsoft. Duct System Summary Job:
Date:
Entire House By.
QUICK CALCS, INC.
317 ST LUCIE LANE. FORT PIERCE. FL34946 Kom: 772-466-6799 Emil: QUICKCALGS@AOL.COM
Project Information
For. CALLAHAN RESIDENCE
504 E. MIDWAYRD., PORT ST. LuaE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest fhdcn rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H20
0.28
in H20
0.22
in H20
0.11010.110
in H20
0.500
in/1 00ft
221
dim
160
1, Supply Branch Detail Table
Cooling
0.50
in H20
0.28
in H20
0.22
in H20
0.110/0.110
in H20
0.500
in/100ft
1207
clim
Name
Design
(13tuh)
Htg
(clm)
Cig
(Cfm)
Design
FIR
Diam
(in)
HxW
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Eqv
Ln (ft)
Trunk
1/2 BATH
c 37
1
2
0.500
4.0
OX0
MFx
2.8
70.0
BATH 2
C 274
7
17
0.500
4.0
OX0
MFx
42.5
110.0
st3
BATH 3
c 274
7
17
0.500
4.6
OxO
MFx
38.6
110.0
s13
BEDROOM 2
c 1902
38
116
0.500
6.0.-
OxO
VlFx
50.4
110.0
St3
BEDROOM 3
c 2085
32
127
0.500
7.0
OX0
MFx
39.4
110.0
St3
DINING
c 2780
20
170
0.500
7.0
OX0
MFx
24.6
90.0
st2
GREATROOM
c 2108
18
129
0.500
7.0
OX0
MFx
31.2
90.0
s12
GREATROOM-A
c 2108
18
129
0.500
7.0
OX0
MFx
20.6
90.0
st2
KITCHEN
c 3643
16
223
0.500
&0
OX0
VlFx
25.4
90.0
st2
LAUNDRY
c 728
13
45
0.500
5.0
OX0
MFx
6.4
70.0
MASTERBATH
c 804
10
49
0.500
5.0
OX0
VIFx
24.5
90.0
sti
MASTER BEDROOM
c 2420
26
148
0.500
7.0
OX0
MFx
22.3
90.0
SO
POWDER
c 145
5
9
0.500
4.0
OX0
MFx
28.7
90.0
sti
TOILET
c 53
1
3
0.500
40
OxO
MFx
19.5
90.0
sti
WIC
c 191
7
12
0.500
4�O
OX0
MFx
22.9
90.0
sti
Wic.
188
3
12
0.500
4.0
OX0
MFx
25.5
90.0
sti
Supply Trunk Detail Table I
Trunk
Htg
Clg
Design
Meloc
Diam
HxW
Duct
Name
Type
(cf1m)
(CIM)
FIR
(fpm)
(in)
(in)
Material
Trunk
st3
PeakAVF
83
277
0.500
508
10.0
0 x 0
VinIFIx
st2
st2
PeakAVF
156
928
0.500
868
14.0
0 x 0
VinIFIx
sti
PeakAVF
51
232
0.500
426
10.0
0 x 0
VinIFIx
Soldfrafic values have beenmanuallyoveffidden
wilightsoft 201 S�AL"S 14:24:31
Pjgft-SLite@Urimrw[201919.0.07RSLI08101 Page I
ACCA ..�o�M�W69ttwftFCVAC\CALLARANRESIDENCEnp Calc=MJ8 FrortDoorlaces: S
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm) �
Cig
0171)
TEL
(ft)
Design
FR
� Meloc
(fpm)
� Diam
(in)
HxW
(in)
Stud/Joist
Opening (in)
Duct
Mat
I Trunk
rbl
OX0
221
1207
0
01
01
01
ox 0 1
\AFxT
wrightsoft- 2019-Aug-08 14:2431