HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Resident ethod I Project Name: FYC-Taraba RV SCANNED L Builder Name: Syneregy Home LLC AUG 0 Street: Riverbend Terrace Permit Office: [ST. City, State, Zip: Port St Lucie, FL, 34953 BY Permit Number: Lucie County, Permitting Owner: Synergy Homes, LLC St. Lucie Countlif Jurisdiction: Design Location: FL, Fort Pierce County: St Lucie (Florida Climate Zone 2 1 . New construction or existing New (From Plans) 9. Wall Types (2834.1 scift.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=6.5 2563.60 112 b. Frame - Wood, Adjacent R=13.0 270.57 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2968.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=21.0 2823.00 ft2 6. Conditioned floor area above grade (112) 2823.29003906 b. Knee Wall (Unvented) R=19.0 145.00 ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R 112 7. Windows(361.9 scift.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 564.65 a. U-Factor: Dbl, U=0.32 361.86 ft2 SHGC: SHGC=0.19 b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 31.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 8.195 it Area Weighted Average SHGC: 0.190 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2623.0 sqft.) Insulation Area EF: 0.930 a. Slab -On -Grade Edge Insulation R=0.0 2823.00 ft2 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.128 Total Proposed Modified Loads, 90.86 PASS Total Baseline Loads: 91.96 1 hereby certify that the plans and specifications covered by Review of the plans and 'tjiE S7�4A this calculation are in compliance with the Florida Energy specifications covered by this -- 0 Code. calculation indicates compliance z with the Florida Energy Code. RREPARED BY: Xi� Before construction is completed DATE: 7/1112019 this building will be inspected for compliance with Section 553.908 A X 1w hereby certify that this building, as designed, is in compliance Florida Statutes. AV with the Florida Energy Code. 0 WE OWNER/AGEINI: A BUILDING OFFICIAL: DATE: ai! MW DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FILE COPY AUG 2 8 2019 7/11/2019 3:07 PIVI EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 'FORM A405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Ju(isdiction: Family Type: New/Existing: Comment: FYC-Taraba RV Bedrooms: 4 User Conditioned Area: 2823 Synergy Homes, LLC Total Stories: 1 1 Worst Case: No Syneregy Homes, LLC Rotate Angle: 0 Cross Ventilation: Whole House Fan: Single-family New (From Plans) Riverbend Terrace, PSL Revised 7/9/2019 Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: Riverbend Terrace County: St. Lucie City, State, Zip: Port St Lucie, FL, 34953 CLIMATE V Design Location Design Temp TMY Site 97.5% 2.5% Int Design Temp Heating Design DailyTemp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—VERO—BEACH—MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2823.290 26341.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Whole House 2823.29 26341.3 Yes 5 4 1 Yes Yes Yes FLOORS y# Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Whole House 282 ft 0 2823 ft2 ---- 0.35 0 0.65 ROOF V # Roof Gable Roof Type Materials Area Area Color Red Solar SA Emitt Emift Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3058 ft2 0 ft2 Medium N 0.7 No 0.9 No 21 22.6 ATTIC V# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2823 ft2 N N CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type — 1 — 2 Under Attic (Unvented) Knee Wall (Unvented) Whole House 0 Blown Whole House 19 Blown 2823 ft2 0.11 Wood 145 f12 0.11 Wood 7/1112019 3:07 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below y it nrnt Tn WAT, 1-ype Space A-Vall A Ft In in Aran R-Vnhip. Frnct'nn Ah-gor rrnrIPR1 1 NE Exterior Concrete Block - Int InsiNhole House 6.5 15.67 -a 0 9.33 0 146.2 ft2 0 0 0.8 0 -2 SE Exterior Concrete Block - Int lnsUVhole House 6.5 20 0 9.33 0 186.6 ft2 0 0 0.8 0 -3 SE Exterior Concrete Block - Int InsiNhole House 6.5 14 0 9.33 0 130.6 ft2 0 0 0.8 0 4 SW Exterior Concrete Block - Int InsUlfhole House 6.5 12 0 9.33 0 112.0 ft2 0 0 0.8 0 5 BE Exterior Concrete Block - Int InslMhole House 645 17 0 9.33 0 158.6 ft2 0 0 0.8 0 6 NW Exterior Concrete Block - Int InsiNhole House 6.5 9.5 0 9.33 0 88.6 ft2 0 0 0.8 0 7 SE Exterior Concrete Block - Int InsiNhole House 6.5 3 0 9.33 0 28.0 ft2 0 0 0.8 0 8 SW Exterior Concrete Block - Int lnsVVhole House 6.5 7.5 0 9.33 0 70.0 ft2 0 0 0.8 0 -9 NW Exterior Concrete Block - Int lnsVVhole House 6.5 13 0 9.33 0 121.3 ft2 0 0 0.8 0 10 SW Exterior Concrete Block - Int lnsVVhole House 6.5 7.75 0 12.33 0 95.6 ft2 0 0 0.8 0 11 NE Exterior Concrete Block - Int lnsVVhole House 6.5 15 0 11 0 165.0 ft2 0 0 0.8 0 12 NE Exterior Concrete Block - Int InsVVhole House 6.5 13.67 0 9.33 0 127.5 ft2 0 0 0.8 0 13 SE Exterior Concrete Block - Int InsVVhole House 6.5 11 0 9.33 0 102.6 ft2 0 0 0.8 0 14 NW Exterior Concrete Block - Int InsiNhole House 6.5 11 0 9.33 0 102.6 ft2 0 0 048 0 15 NE Exterior Concrete Block - Int InslMhole House 6.5 7 0 9.33 0 65.3 ft2 0 0 0.8 0 16 SW Exterior Concrete Block - Int InslHhole House 6.5 3 0 9.33 0 28.0 ft2 0 0 0.8 0 17 SW Garage Frame - Wood Whole House 13 29 0 9.33 0 270.6 ft2 0 0.23 0.8 0 18 NW Exterior Concrete Block - Int Insiffhole House 6.5 8.5 0 9.33 0 79.3 112 0 0 0.8 0 19 SW Exterior Concrete Block - Int InsiNhole House 6.5 15 0 9.33 0 139.9 ft2 0 0 0.8 0 20 NW Exterior Concrete Block - Int InsiNhole House 6.5 9 0 9.33 0 8440 112 0 0 0.8 0 21 NW Exterior Concrete Block - Int lnsVVhole House 6.5 18 0 9.33 0 16749 ft2 0 0 0.8 0 22 NW Exterior Concrete Block - Int lnsVVhole House 6.5 12 0 9.33 0 112.0 ft2 0 0 0.8 0 23 NW Exterior Concrete Block - Int lnsVVhole House 6.5 6 0 9.33 0 56.0 ft2 0 0 0.8 0 24 NE Exterior Concrete Block - Int InsUfhole House 6.5 7 0 9.33 0 65.3 ft2 0 0 0.8 0 25 NE Exterior Concrete Block - Int InsiNhole House 6.5 9 0 9.33 0 84.0 ft2 0 0 048 0 26 SE Exterior Concrete Block - Int InsiNhole House 6.5 5 0 9.33 0 46.7 112 0 0 0.8 0 DOORS V Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated Whole House None .29 3 6.7 20 ft2 2 SW Insulated Whole House None .29 3 6.7 20 ft2 3 SW Insulated Whole House None .29 2.7 8 21.4 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRO U-Factor SHGC Imp Area Depth Separatiop Int Shade Screening - 1 NE 1 Vinyl Low-E Double Yes 0.32 0.19 N 24.0 ft2 1 ft0in 1 ft0in None None - 2 SE 2 Vinyl Low-E Double Yes 0.32 0.19 N 12.0 ft2 1 ft0ln 1 ft0in None None - 3 SW 4 Vinyl Low-E Double Yes 0.32 0.19 N 22.5 ft2 2 it 0 in 1 ft 0 in Drapes/blinds Exterior 5 - 4 SE 7 Vinyl Low-E Double Yes 0.32 0.19 N 4.0 ft2 1 ItOln 1 ft0in None None - 5 SW 8 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ft2 6 it 0 in 1 It 0 in None Exterior 5 - 6 SW 10 Vinyl Low-E Double Yes 0.32 0.19 N 18.0 ft2 12ft0in 1 It 0 in None None 7/11/2019 3:07 PM - EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 'FnRM A405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 7 8 9 10 - 11 - 12 13 14 15 - 16 NE 11 Vinyl NE 11 Vinyl NE 12 Vinyl SE 13 Vinyl SW 16 Vinyl NW 18 Vinyl NW 20 Vinyl NW 21 Vinyl NW 22 Vinyl NE 25 Vinyl Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes 0.32 0.19 N 96.0 ft2 12 ft 0 in 0.32 0.19 N 36.0 f12 12 ft 0 in 0.32 0.19 N 30.0 ft2 12 It 0 in 0.32 0.19 N 30.0 ft2 12 It 0 in 0.32 0.19 N 15.0 ft2 1 It 0 in 0.32 0.19 N 4.0 ft2 1 It 0 in 0.32 0.19 N 4.0 ft2 2 If 0 in 0.32 0.19 N 15.0 ft2 1 It 0 in 0.32 0.19 N 15.0 ft2 I It 0 in 0.32 0.19 N 21.4 ft2 10 It 0 in 4 It 0 in 2 ft 0 in I It 0 in I It 0 in 1 ft0in 1 ft 0 in 2 It 0 in 1 It 0 in 1 ft 0 in 1 It 0 in Drapes/blinds None Drapesiblinds Drapes/blinds None None None Drapestblinds Drapestblinds Drapes/blinds None None Exterior 5 Exterior 5 Exterior 5 None Exterior 5 Exterior 5 Exterior 5 None GARAGE y# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1102 W 1102 112 105 It 9.33 it 0 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000296 2195.1 120.51 226.63 .1092 5 HEATING SYSTEM y # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat[ None COPA 31 kBtu1hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 16 35 kBtu/hr 1050 cfm 0.77 1 sys#1 HOT WATER SYSTEM y# System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 50 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Cert # Company Name System Model # Collector Model # Collector Area Storage Volume FEF None None ft2 7/11/2019 3:07 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R40S-217117 INPUT SUMMARY CHECKLIST REPORT DUCTS ---- Supply ---- ---- Return ---- Air OFM25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 564.65 Attic 141.16 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Prograrnable Thermostat: Y Ceiling Fans: Coo' in Ian Feb Me r AAPprr me un Jul Jun A.ug 8ctt Nov De 0 Heat ng an J Feb Mar - J1 I Mayy 11 jxj Ju jxj A 9 ri ss:PP J� No v Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct X X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 —a--- 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 66 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust GFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 85 0 0 0 1 - Electric Strip Heat % 1 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbsfsq.ft 0 ft2 0 ft 0.3 Whole House 7/11/2019 3:07 PM EnergyGaugeg USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R-6 0 2. Single-family or multiple -family 2. Sincile-fami y b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 4. Number of bedrooms 4. 4 13. Cooling system: Capacity ---- 35-0 a) Split system SEER- 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Groundiwater source SEER/COP_ 6. Conditioned floor area (sq. ft.) 6. 2823 d) Room unitIPTAC EER a) Other 16.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.320 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.190 c) Area 7c. 361.9 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floortype, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (insulation R-value) B. Adjacent: 1. Wood frame (insulation R-value) 2. Masonry (insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 14. Heating system: Capacity 31.0 a) Split system heat pump HSPF__ b) Single package heat pump HSPF�_ c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE a) Gas furnace, LPG AFUE 0 Other 9a. 0.0 9b.- 15. Water heating system 9c. a) Electric resistance EF�_0.93 b) Gas fired, natural gas EF- c) Gas fired, LPG EF d) Solar system with tank EF_ 10A1._ a) Dedicated heat pump with tank EF 1 OA2. 6.5 0 Heat recovery unit Heafflei;0/6_ g) Other 1 OB1. 13.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 0.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. 19.0 d) Multizone cooling credit 11d. No a) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature7:z Date: 8'19 L'i OF Address of New Home: Riverbend Terrace City/FL Zip: Port St Lucie. FL 34953 7/11/2019 3:06:27 PM EnergyGaugeD USA 6.0.03 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Permit #: ioll*�Ijr!brma-ft'n- Builder: Syneregy Homes, LLC Community: Lot: NA Address: Riverbend Terrace City: Port St Lucie State: FL Zip: 34953 suits Adr,"Lee'lik'a !qlT-. Rpqql��, Passinq"rd 'Mustrneet,`ef�Per:thq,fO: nce, �r�s�riptivel or-'E?1t thod �PRES�6-Fi[076�E'MEi-H6D.f64�buileihg ordw6lflnj�unit shqllbe�tqs�ed and verp�das h6ihg an iii�-leaka96 rate of notreixceedinq 7alr 'a' 'p�r�e�s-s�ur�e�6fb.2:ir�06'w.g��. c6ngps,perhour6i a an !pr='RO16RMANCEorthi�gETHdb.Th�-b�il'ai�g�6rdw&flin�,66!t�k'�1:69te'sted4�n�" d' ex�' ding qyenp�,.,;ks hay!ng'�n�ali leakage i�te of not oe�' 26.'sele6tiv Adk(��J, viO�,-as'a6wo onFormROO'5- oV. Parfi3rmanc61`orF446G-2017 (ERI), section lab�fleda�i - nfiltrati6n, gub-section ACH56. -;kO ACH(�O) spqchledon Form R405-'2017-Energy Catc (Per�ormance),orR406.2017(ERI): x 60 - 26341 Method for calculating building volu a: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans F]PASS 0 Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation 0 Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNETACC 380 and reported ata pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7). Florida Statues.or individuals licensed as set forth in Section 489.105(3)(% (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode officiaL Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shaJI be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 16. Supply and return registers, if installed at the time of the test, shall be fully open. OstingiCompany,, Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test. Printed Name of Tester: License/Certification #: Issuing Authority: 7/11/2019 3:06:41 PM EnergyGauge@ USA 6.0.03 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page I of I ��5 0 Z Ils SCANNED BY St Lucie County FYC-Taraba RV HVAC Load Calculations for Synergy Homes, ILLC 4568 Royal Palm Beach Blvd West Palm Beach, FL 33411 Prepared By: Ken Fonorow Florida H.E.R.O., Inc. 15220 NW 6th Ave Newberry, FI 32669 (352) 472-5661 Thursday, July 11, 2019 -AUG 2 8 2� Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Sottware Development, Inc. Florida H.E.R.O. FYC-Taraba RV Newberrv. FL 32669 Eage 2 Proiect Report General Probect Information Project Title: FYC-Taraba RV Designed By: Ken Fonorow Project Date: 5/3/2019 Project Comment: Riverbend Terrace, PSL Revised 7/9/2019 Client Name: Synergy Homes, LLC ClientAddress: 4568 Royal Palm Beach Blvd Client City: West Palm Beach, FL 33411 Client Phone: 561315-3317 Client E-Mail Address: deanne@synergyhomesfi.com Company Name: Flodda H.E.R.O., Inc. Company Representative: Ken Fonorow Company Address: 15220 NW 5th Ave Company City: Newberry, FI 32669 Company Phone: (352) 472-5661 Company E-Mail Address: ken@fioridahero.com Company Website: www.floddahero.com I Desian Data Reference City: Fort Pierce, Florida Building Orientation: Front door faces Southwest Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Rulh Rei.Hurn RPI Hurn Dry Bul Difference Dry Winter: Bulb Wet 42 39.4 n/a n/a 72 n/a Summer: 90 78 59% 50% 75 61 Check Figures Total Building Supply CFM: 1,200 CFM Per Square ft.: 0.425 Square ft. of Room Area: 2,823 Square ft. Per Ton: 994 Volume (W): 32,431 Building Loads Total Heating Required Including Ventilation Air: 30,043 Btuh 30.043 MBH Total Sensible Gain: 26,848 Btuh 79 % Total Latent Gain: 7,243 Btuh 21 % Total Cooling Required Including Ventilation Air: 34,091 Btuh 2.84 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I C:\Users\OwnerXDesktop\All Rh Files\All rh9 findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM Rhvao - Residential & Light Commercial HVAC Loads Elite Sottware Development, Inc. Florida H.E.R.O. FYC-Taraba RV Newberm EL 32669 Page 3 Miscellaneous Report System 1 Whole House Outdoor Outdoor Outdoor Indoor Indoor Gr n: InDut Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum ON ulb Differen c Winter: 42 39.4 80% n/a 72 n1a Summer: 90 78 59% 50% 75 61.09 Duct Sizing Inputs Main Trun Runnut Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.15000 0.15000 Pressure Drop: 0.1000 in.wg./l 00 ft. 0.1000 in.wg./l 00 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. F r Data Winter Infiltration Specified: 0.220 AC/hr Surnme 0.110 AC/hr 119 CFM 59 CFM Infiltration Actual: 0.282 AC/hr 0.000 AC1hr Above Grade Volume: X 32,431 Cu.ft. X 32 431 Cu.ft. 9,132 Cu.ft./hr X 0-0167 0 Cu.ft./hr X D 0167 Total Building Infiltration: 152 CFM 0 CFM Total Building Ventilation: 0 CFM 95 CFM --System I — Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09,Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1. 10 X 0.999 X 30.00 Winter Temp. Difference) Winter Infiltration Specified: 0.220 AC/hr (119 CFM), Construction: Semi -Tight Summer Infiltration Specified: 0. 110 AC/hr (59 CFM), Construction: Semi -Tight C:\Users\Owner\Desktop\Ail Rh Files\All rh9 findings�FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Florida H.E.R.O. FYC-Taraba RV Newberry. FL 32669 Eage 4 DUCt Size Preview Room or Source I Minimu Maxim Rough Des! SP Du Du H t Duct Name Velool Velooll Factol U1901 Loss Velocit Lengt Fh Svstern 1 Supqly�Runouts Zone 1 Built-in 0.15 358.4 141, 2-f 1-Master Bedroom 2-Master VVIC 1 Built-in 750 0.11 '__ - . -_ - t- I 750 0.15 OA 174.6 117 1 50 -------- - 1 - - 1-4 3-Master WC 2 Built-in 45d 750 0.15 _16.i 4__ 20M 2 __1:4 4-Master Bath -450' 750 0.15 0.1� 336.7,____ 141OW63 66' 1-6 5-Master Bath WG - I Built-in 45 - 0 750 -0.15,--- 0.1 208.3--- 1-20m, - 181� 1-4 6-Den 450 750 0.15 0.1 337.5 SOWFal 661 1__6 _;_Built-in 7-Foyer I Built-in 45d *0 0.15' 348.1 48 O-Great Room Bullt-1 n 450--_ -0.1 75d 0.15 0.1�_ 629.2 __21,0_ _1-4 336' 2-7 9-Dininq - Built-in 450 750 0.15 0.1 435.1 __1341ffM31__ 1391W8 - 851 1-6 10-Kitchen 'Built-in 450 75Q 0.15 0.1 525.6 20 Q3, jjjVl 1 103 -7 1_6 11 -Pantry Built-in 450 F 750 0.15 ____O.i 801 I I 24 M' : 7] _7 1-4 12-Bedroom 2 Built -In 45d 0.15 0.1 339.6' 57 67 1__G Built-in 450 7, 019 Of 566.� 87 ZZ n4' 4�� 11 -13-Utilitv - 14-Bath 2 15-Bedroom 3 Built-in t P- tfit In 1 450 1 45Q 7 015 Oil 75 0.15 0.1 171.9 - 352.5 35 73MNM�_ 15 69 _�66" -4 16-Bedroom 4 Built-in 45d 75 0.1� 0.1 334.3 53 43 1 ill 1-4 17-Bedroom 4 VVIC - Built-in 45d 75Q 0.15 0.1 129.5 - _4 - __ 18-Bath 3 1 Built-in I--- 450 75 0.4' 0.1 1j 591.8 55 6 i 521 1-4 Other Ducts In yelem 1 S j Suppiv Main Trunk Built-in 1 650 900 0.15 0.1 675 11200197206 1,200 16XIE Summary Svstem 1 Heatina Flow: 1200 Coolino Flow: 1200 CA1Jsers\OvvnerNDesktop\All Rh Files\All A9 findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM Rhvac - Re Idential & Light Commercial HVAC Loads Elite Software Development, Inc. Florida H.E.R.O. FYC-Taraba RV Newberry. FL 3209 Total Buildini:7 Summaty Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 1 OC-f: Glazing -French door, double pane low-e glass (e 24 324 0 1,116 1,116 0.40), insulated fiberglass frame, ground reflectance = 0.32, U-value 0.45, SHGC 0.43 VYN 34 23: Glazing-Dbl Pn Vyn Fr U.34 SHGC.23, 16 163 0 305 305 ground reflectance = 0.23, U-value 0.34, SHGC 0.23 VYN 34 23: Glazing-Dbl Pn Vyn Fr U.34 SHGC.23, 82.5 842 0 1,304 1,304 ground reflectance = 0.23, outdoor insect screen with 50% coverage, medium color blinds at 45'with 25% coverage, U-value 0.34, SHGC 0.23 VYN 34 23: Glazing-DbI Pn Vyn Fr U .34 SHGC .23, 4 41 0 71 71 ground reflectance = 0.23, U-value 0.34, SHGC 0.23 VYN 34 23: Glazing-DbI Pn Vyn Fr U.34 SHGC .23, 16 153 0 134 134 ground reflectance = 0.32, outdoor insect screen with 50% coverage, U-value 0.34, SHGC 0.23 VYN 34 23: Glazing-DbI Pn Vyn Fr U.34 SHGC.23, 54 551 0 1,296 1,296 ground reflectance = 0.32, U-value 0.34, SHGC 0.23 1OC-f.' Glazing -French door, double pane low-e glass (e 96 1,296 0 3,892 3,892 0.40), insulated fiberglass frame, ground reflectance = 0.32, medium color blinds at 45* with 25% coverage, U-value 0.45, SHGC 0.43 VYN 34 23: Glazing-DbI Pn Vyn Fr U.34 SHGC.23, 30 306 0 210 210 ground reflectance = 0.32, outdoor insect screen with 50% coverage, medium color blinds at 45* with 25% coverage, U-value 0.34, SHGC 0.23 VYN 34 23: Glazing-Dbl Pn Vyn Fr U .34 SHGC .23, 15 153 0 283 283 ground reflectance = 0.23, outdoor insect screen with 50% coverage, U-value 0.34, SHGC 0.23 VYN 34 23: Glazing-Dbl Pn Vyn Fr U.34 SHGC.23, 4 41 0 84 84 ground reflectance = 0.23, outdoor insect screen with 50% coverage, U-value 0.34, SHGC 0.23 I OC-f.' Glazing -French door, double pane low-e glass (e 21.4 288 0 866 866 0.40), insulated fiberglass frame, ground reflectance = 0.32, medium color blinds at 450 with 50% coverage, U-value 0.46, SHGC 0.43 11 P: Door -Metal - Polyurethane Core, U-value 0.29 61.4 534 0 463 463 13A-6ocs: Wall -Block, board insulation only, R-6 board 2140.3 7,125 0 3,158 3,158 insulation, open core, siding finish, U-value 0. 111 12C-Osw: Wall -Frame, R-1 3 insulation in 2 x 4 stud 110 300 0 215 215 cavity, no board insulation, siding finish, wood studs, U-value 0.091 ISAl-21o: Roof/Ceiling-Roof Joists Between Roof Deck 3069.4 4,327 0 3,750 3,750 and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, Dark or Bold -Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel, R-21 open cell 1/2 lb. spray foam, 5.5 inches in 2 x 6 joist cavity, 1 inch on joist, U-value 0.047 16B-19: Roof/Ceiling-Under Attic with Insulation on Attic 145 213 0 355 355 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-19 insulation, U-value 0.049 22A-pl: Floor -Slab on grade, No edge insulation, no 282 8,366 0 0 0 insulation below floor, any floor cover, passive, light y so -value 0.989 —dr Jil U Subtotals for structure: 25,023 0 17,502 17,502 People: 6 1,200 1,380 2,580 C:%Users\Owner\Desktop\A]I.Rh Files\All.rhg findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM Rhvac; - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Florida H.E.R.O. FYC-Taraba RV blewbg[ry, FL 32669 Eage 6 Total Buildiag Summary Loads (contd) t Area Sen Lat Sen Total I Quan Loss Gain Gain Gain Equipment: 2,100 6,400 8,500 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 152, Summer CFM: 0 5,020 0 0 0 Ventilation: Winter CFM: 0, Summer CFM: 95 0 3,943 1,566 5,509 -Exhaust., W*interCFM."95,.Summ.e-rC-FM.:O--. Total Building Load Totals: 30,043 7,243 26,848 34,091 Check Figures Total Building Supply CFM: 1,200 CFM Per Square ft.: 0.426 Square ft. of Room Area: 2,823 Square ft. Per Ton: 994 Volume (W): 32,431 -7:71 Building Loads Total Heating Required Including Ventilation Air: 30,043 Btuh 30.043 MBH Total Sensible Gain: 26,848 Btuh 79 % Total Latent Gain: 7,243 Btuh 21 % Total Cooling Required Including Ventilation Air: 34,091 Btuh 2.84 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturers performance data at your design conditions. C:\Users\Owner\Desktop\All Rh Files\All rh9 findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. I J Florida H.E.R.O. FYC-Taraba RV I Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: AHRI Reference No.: Capacity: Efficiency: Heating System Type: Model: Manufacturer: Capacity: Efficiency: Standard Air Conditioner 4TTR40371-11 TAM9AOC36V31 TRANE TRANE 10093791 35,000 16 SEER Electric Resistance TAM7AOC36 Trane 31 0% This system's equipment was selected in accordance vvith ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODS: 42F, SIDB: 75F, SIRH: 50%, WIDB: 72F, Sen. gain: 26,848 Btuh, Lat. gain: 7,243 Stuh, Sen. loss: 30,043 Btuh, Entering c1g. coil DB: 76.2F, Entering c1g. coil VVB: 64F, Entering htg. coil DB: 72F, CIg. coil TD: 20F, Htg. coil TD: 70F, Req. cIg. airflow: 1150 CFM, Req. htg. airflow: 391 CFM C:\Users\Owner\Desktop\All Rh Files\All rh9 findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, I c. Florida H.E.R.O. FYC-Taraba RV Newberry, FL 32669 page A system 1 Room Load Summa1y -1 Htg Min Run Run Clg CIg Min A Room Area Sens Htg Duct Duct Sens Lat CIg No Name SF Btuh CFM Size Val Btuh Btuh --- Zone 1- 1 Master Bedroom 368 3,690 48 2-6 358 2,965 400 135 141 2 Master WIC 1 84 1,243 16 1-4 175 321 0 15 15 3 Master WIC 2 36 56 1 1-4 27 49 0 2 2 4 Master Bath 224 3,527 46 1-6 337 1,393 450 63 66 5 Master Bath WC 18 295 4 1-4 208 383- 550 17 18 6 Den 172 2,013 26 1-6 337 1,396 0 64 66 7 Foyer 78 1,193 16 1-4 348 640 0 29 30 8 Great Room 420 3,354 44 2-7 629 7,085 600 322 336 9 Dining 185 3,469 45 1-6 435 1,800 0 82 85 10 Kitchen 330 512 7 1-6 526 2,174 550 99 103 11 Pantry 42 607 8 1-4 80 147 0 7 7 12 Bedroom 2 182 1,416 18 1-6 340 1,405 0 64 67 13 Utility 124 2,172 28 1-4 566 1,041 250 47 49 14 Bath 2 81 864 11 1-4 172 316 250 14 15 15 Bedroom 3 207 1,827 24 1-6 352 1,458 0 66 69 16 Bedroom 4 186 1,338 17 1-6 334 1,383 0 63 66 17 Bedroom 4 WIC 42 1,085 14 1-4 129 238 0 11 11 18 Bath-3--- 45 1,382 IS 1-4' 592 1�088 250 49 52 Ventilation 0 1,566 3,943 -Systern 1 total 823._ 30,043 391 26848 7,243_1,150 1,200 System 1 Main Trunk Size: 16xl6 in. Velocity: 675 ft./min Loss per 100 ft.: 0.238 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent T olal Tons Split Btuh Btuh Btuh Net Required: 2.84 79%/21% 26,848 7,243 34,091 Actual: 2.92 77%/23% 26,950 8,050 35,000 Equipment Data Type: Heating System Electric Resistance Cooling Syste Standard Air Conditioner Model: TAM7AOC36 4TTR40371-11 Indoor Model: TAM9AOC36V31 Brand: TRANE Efficiency: 0% 16 SEER Sound: 0 0 Capacity: 31 Btuh 35,000 Stuh Sensible Capacity: n/a 26,950 Btuh Latent Capacity: n/a 8,050 Btuh AHRI Reference No.: n1a 10093791 This system's equipment was selected in accordance vvith ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 72F, Sen. gain: 26,848 Btuh, Lat. gain: 7,243 Btuh, Sen. loss: 30,043 Btuh, Entering cIg. coil DB: 76.2F, Entering c1g. coil WB: 64F, Entering htg. coil DB: 72F, Cig. coil TD: 20F, Htg. coil TD: 70F, Req. c1g. airflow: 1150 CFM, Req. htg. airflow: 391 CFM C:\Users\Owner\Desktop\A[I.Rh Files\All.rh9findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM