FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Resident ethod I
Project Name: FYC-Taraba RV
SCANNED
L
Builder Name: Syneregy Home LLC
AUG 0
Street: Riverbend Terrace
Permit Office:
[ST.
City, State, Zip: Port St Lucie, FL, 34953 BY
Permit Number: Lucie County, Permitting
Owner: Synergy Homes, LLC
St. Lucie Countlif
Jurisdiction:
Design Location: FL, Fort Pierce
County: St Lucie (Florida Climate Zone 2
1 . New construction or existing
New (From Plans)
9. Wall Types (2834.1 scift.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=6.5 2563.60 112
b. Frame - Wood, Adjacent
R=13.0 270.57 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
4
d. N/A
R= ft2
10. Ceiling Types (2968.0 sqft.)
Insulation Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=21.0 2823.00 ft2
6. Conditioned floor area above grade (112)
2823.29003906
b. Knee Wall (Unvented)
R=19.0 145.00 ft2
Conditioned floor area below grade (W)
0
c. N/A
R= ft2
11. Ducts
R 112
7. Windows(361.9 scift.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 564.65
a. U-Factor: Dbl, U=0.32
361.86 ft2
SHGC: SHGC=0.19
b. U-Factor: NIA
ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.0 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
31.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
8.195 it
Area Weighted Average SHGC:
0.190
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2623.0 sqft.)
Insulation Area
EF: 0.930
a. Slab -On -Grade Edge Insulation
R=0.0 2823.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. NIA
R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.128
Total Proposed Modified Loads, 90.86
PASS
Total Baseline
Loads: 91.96
1 hereby certify that the plans and specifications covered by
Review of the plans and
'tjiE S7�4A
this calculation are in compliance with the Florida Energy
specifications covered by this
-- 0
Code.
calculation indicates compliance
z
with the Florida Energy Code.
RREPARED BY: Xi�
Before construction is completed
DATE: 7/1112019
this building will be inspected for
compliance with Section 553.908
A X
1w hereby certify that this building, as designed, is in compliance
Florida Statutes.
AV
with the Florida Energy Code.
0 WE
OWNER/AGEINI: A
BUILDING OFFICIAL:
DATE: ai! MW
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FILE COPY
AUG 2 8 2019
7/11/2019 3:07 PIVI EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
'FORM A405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Ju(isdiction:
Family Type:
New/Existing:
Comment:
FYC-Taraba RV Bedrooms: 4
User Conditioned Area: 2823
Synergy Homes, LLC Total Stories: 1
1 Worst Case: No
Syneregy Homes, LLC Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Single-family
New (From Plans)
Riverbend Terrace, PSL Revised 7/9/2019
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: Riverbend Terrace
County: St. Lucie
City, State, Zip: Port St Lucie,
FL, 34953
CLIMATE
V Design Location
Design Temp
TMY Site 97.5% 2.5%
Int Design Temp Heating Design DailyTemp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL—VERO—BEACH—MUNI 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2823.290 26341.3
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Whole House
2823.29 26341.3 Yes 5
4 1 Yes Yes Yes
FLOORS
y#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Whole House 282 ft 0
2823 ft2 ---- 0.35 0 0.65
ROOF
V #
Roof Gable Roof
Type Materials Area Area Color
Red Solar SA Emitt Emift Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip
Metal 3058 ft2 0 ft2 Medium
N 0.7 No 0.9 No 21 22.6
ATTIC
V#
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Unvented 0 2823 ft2 N N
CEILING
V #
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
— 1
— 2
Under Attic (Unvented)
Knee Wall (Unvented)
Whole House 0 Blown
Whole House 19 Blown
2823 ft2 0.11 Wood
145 f12 0.11 Wood
7/1112019 3:07 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing
Solar Below
y it
nrnt
Tn
WAT, 1-ype Space
A-Vall A
Ft
In
in
Aran
R-Vnhip.
Frnct'nn
Ah-gor
rrnrIPR1
1
NE
Exterior
Concrete Block - Int InsiNhole House
6.5
15.67
-a
0 9.33
0
146.2 ft2
0
0
0.8
0
-2
SE
Exterior
Concrete Block - Int lnsUVhole House
6.5
20
0 9.33
0
186.6 ft2
0
0
0.8
0
-3
SE
Exterior
Concrete Block - Int InsiNhole House
6.5
14
0 9.33
0
130.6 ft2
0
0
0.8
0
4
SW
Exterior
Concrete Block - Int InsUlfhole House
6.5
12
0 9.33
0
112.0 ft2
0
0
0.8
0
5
BE
Exterior
Concrete Block - Int InslMhole House
645
17
0 9.33
0
158.6 ft2
0
0
0.8
0
6
NW
Exterior
Concrete Block - Int InsiNhole House
6.5
9.5
0 9.33
0
88.6 ft2
0
0
0.8
0
7
SE
Exterior
Concrete Block - Int InsiNhole House
6.5
3
0 9.33
0
28.0 ft2
0
0
0.8
0
8
SW
Exterior
Concrete Block - Int lnsVVhole House
6.5
7.5
0 9.33
0
70.0 ft2
0
0
0.8
0
-9
NW
Exterior
Concrete Block - Int lnsVVhole House
6.5
13
0 9.33
0
121.3 ft2
0
0
0.8
0
10
SW
Exterior
Concrete Block - Int lnsVVhole House
6.5
7.75
0 12.33
0
95.6 ft2
0
0
0.8
0
11
NE
Exterior
Concrete Block - Int lnsVVhole House
6.5
15
0 11
0
165.0 ft2
0
0
0.8
0
12
NE
Exterior
Concrete Block - Int InsVVhole House
6.5
13.67
0 9.33
0
127.5 ft2
0
0
0.8
0
13
SE
Exterior
Concrete Block - Int InsVVhole House
6.5
11
0 9.33
0
102.6 ft2
0
0
0.8
0
14
NW
Exterior
Concrete Block - Int InsiNhole House
6.5
11
0 9.33
0
102.6 ft2
0
0
048
0
15
NE
Exterior
Concrete Block - Int InslMhole House
6.5
7
0 9.33
0
65.3 ft2
0
0
0.8
0
16
SW
Exterior
Concrete Block - Int InslHhole House
6.5
3
0 9.33
0
28.0 ft2
0
0
0.8
0
17
SW
Garage
Frame - Wood Whole House
13
29
0 9.33
0
270.6 ft2
0
0.23
0.8
0
18
NW
Exterior
Concrete Block - Int Insiffhole House
6.5
8.5
0 9.33
0
79.3 112
0
0
0.8
0
19
SW
Exterior
Concrete Block - Int InsiNhole House
6.5
15
0 9.33
0
139.9 ft2
0
0
0.8
0
20
NW
Exterior
Concrete Block - Int InsiNhole House
6.5
9
0 9.33
0
8440 112
0
0
0.8
0
21
NW
Exterior
Concrete Block - Int lnsVVhole House
6.5
18
0 9.33
0
16749 ft2
0
0
0.8
0
22
NW
Exterior
Concrete Block - Int lnsVVhole House
6.5
12
0 9.33
0
112.0 ft2
0
0
0.8
0
23
NW
Exterior
Concrete Block - Int lnsVVhole House
6.5
6
0 9.33
0
56.0 ft2
0
0
0.8
0
24
NE
Exterior
Concrete Block - Int InsUfhole House
6.5
7
0 9.33
0
65.3 ft2
0
0
0.8
0
25
NE
Exterior
Concrete Block - Int InsiNhole House
6.5
9
0 9.33
0
84.0 ft2
0
0
048
0
26
SE
Exterior
Concrete Block - Int InsiNhole House
6.5
5
0 9.33
0
46.7 112
0
0
0.8
0
DOORS
V
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated Whole House
None
.29
3
6.7
20 ft2
2
SW
Insulated Whole House
None
.29
3
6.7
20 ft2
3
SW
Insulated Whole House
None
.29
2.7
8
21.4 ft2
WINDOWS
Orientation shown
is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes NFRO U-Factor
SHGC
Imp
Area
Depth
Separatiop
Int Shade
Screening
-
1
NE 1
Vinyl Low-E Double Yes
0.32
0.19
N
24.0 ft2
1 ft0in
1 ft0in
None
None
-
2
SE 2
Vinyl Low-E Double Yes
0.32
0.19
N
12.0 ft2
1 ft0ln
1 ft0in
None
None
-
3
SW 4
Vinyl Low-E Double Yes
0.32
0.19
N
22.5 ft2
2 it 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
-
4
SE 7
Vinyl Low-E Double Yes
0.32
0.19
N
4.0 ft2
1 ItOln
1 ft0in
None
None
-
5
SW 8
Vinyl Low-E Double Yes
0.32
0.19
N
15.0 ft2
6 it 0 in
1 It 0 in
None
Exterior 5
-
6
SW 10
Vinyl Low-E Double Yes
0.32
0.19
N
18.0 ft2
12ft0in
1 It 0 in
None
None
7/11/2019 3:07 PM - EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
'FnRM A405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
7
8
9
10
- 11
- 12
13
14
15
- 16
NE 11 Vinyl
NE 11 Vinyl
NE 12 Vinyl
SE 13 Vinyl
SW 16 Vinyl
NW 18 Vinyl
NW 20 Vinyl
NW 21 Vinyl
NW 22 Vinyl
NE 25 Vinyl
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
0.32 0.19 N 96.0 ft2 12 ft 0 in
0.32 0.19 N 36.0 f12 12 ft 0 in
0.32 0.19 N 30.0 ft2 12 It 0 in
0.32 0.19 N 30.0 ft2 12 It 0 in
0.32 0.19 N 15.0 ft2 1 It 0 in
0.32 0.19 N 4.0 ft2 1 It 0 in
0.32 0.19 N 4.0 ft2 2 If 0 in
0.32 0.19 N 15.0 ft2 1 It 0 in
0.32 0.19 N 15.0 ft2 I It 0 in
0.32 0.19 N 21.4 ft2 10 It 0 in
4 It 0 in
2 ft 0 in
I It 0 in
I It 0 in
1 ft0in
1 ft 0 in
2 It 0 in
1 It 0 in
1 ft 0 in
1 It 0 in
Drapes/blinds
None
Drapesiblinds
Drapes/blinds
None
None
None
Drapestblinds
Drapestblinds
Drapes/blinds
None
None
Exterior 5
Exterior 5
Exterior 5
None
Exterior 5
Exterior 5
Exterior 5
None
GARAGE
y#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
1102 W
1102 112
105 It 9.33 it
0
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EqLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000296
2195.1 120.51 226.63 .1092
5
HEATING SYSTEM
y #
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat[ None
COPA 31 kBtu1hr
1
sys#1
COOLING SYSTEM
V #
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
None
SEER: 16 35 kBtu/hr 1050 cfm
0.77 1
sys#1
HOT WATER SYSTEM
y#
System Type
SubType Location
EF Cap Use SetPnt
Conservation
1
Electric
None Garage
0.93 50 gal 40 gal 120 deg
None
SOLAR HOT WATER SYSTEM
V FSEC
Cert # Company Name
System Model # Collector Model #
Collector
Area
Storage
Volume
FEF
None None
ft2
7/11/2019 3:07 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R40S-217117 INPUT SUMMARY CHECKLIST REPORT
DUCTS
---- Supply ----
---- Return ----
Air
OFM25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1
Attic 6 564.65
Attic
141.16
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Prograrnable Thermostat: Y
Ceiling Fans:
Coo' in Ian
Feb Me r
AAPprr
me
un Jul
Jun
A.ug
8ctt
Nov
De 0
Heat ng an
J
Feb Mar -
J1
I
Mayy
11 jxj Ju
jxj A 9
ri ss:PP
J�
No v
Dec
Venting Jan
Feb Mar
Apr
May
Jun Jul
Aug
Sep
Oct
X
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
—a---
9 10
11
12
Cooling (WD)
AM 78
78
78
78
78 78
78
78
80 80
80
80
PM 80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH)
AM 78
78
78
78
78 78
78
78
78 78
78
78
PM 78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD)
AM 66
66
66
66
66 68
68
68
68 68
68
68
PM 68
68
68
68
68 68
68
68
68 68
66
66
Heating (WEH)
AM 66
66
66
66
66 68
68
68
68 68
68
68
PM 68
68
68
68
66 68
68
68
68 68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust GFM
Fan Watts HRV Heating System
Run Time Cooling System
Runtime Vent
85
0
0
0 1 - Electric Strip Heat
% 1 - Central Unit
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 lbsfsq.ft
0 ft2
0 ft
0.3
Whole House
7/11/2019 3:07 PM EnergyGaugeg USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R-6 0
2. Single-family or multiple -family 2. Sincile-fami y b) Return ducts R 6.0
c) AHU location Attic
3. No. of units (if multiple -family) 3.
4. Number of bedrooms 4. 4 13. Cooling system: Capacity ---- 35-0
a) Split system SEER-
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Groundiwater source SEER/COP_
6. Conditioned floor area (sq. ft.) 6. 2823 d) Room unitIPTAC EER
a) Other 16.0
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.320
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.190
c) Area 7c. 361.9
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floortype, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (insulation R-value)
B. Adjacent:
1. Wood frame (insulation R-value)
2. Masonry (insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
14. Heating system: Capacity 31.0
a) Split system heat pump HSPF__
b) Single package heat pump HSPF�_
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
a) Gas furnace, LPG AFUE
0 Other
9a. 0.0
9b.-
15. Water heating system
9c.
a) Electric resistance EF�_0.93
b) Gas fired, natural gas EF-
c) Gas fired, LPG EF
d) Solar system with tank EF_
10A1._
a) Dedicated heat pump with tank EF
1 OA2. 6.5
0 Heat recovery unit Heafflei;0/6_
g) Other
1 OB1. 13.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 0.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c. 19.0
d) Multizone cooling credit
11d. No
a) Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature7:z Date: 8'19 L'i
OF
Address of New Home: Riverbend Terrace City/FL Zip: Port St Lucie. FL 34953
7/11/2019 3:06:27 PM EnergyGaugeD USA 6.0.03 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Permit #:
ioll*�Ijr!brma-ft'n-
Builder: Syneregy Homes, LLC Community: Lot: NA
Address: Riverbend Terrace
City: Port St Lucie State: FL Zip: 34953
suits
Adr,"Lee'lik'a !qlT-. Rpqql��, Passinq"rd 'Mustrneet,`ef�Per:thq,fO: nce, �r�s�riptivel or-'E?1t thod
�PRES�6-Fi[076�E'MEi-H6D.f64�buileihg ordw6lflnj�unit shqllbe�tqs�ed and verp�das h6ihg an iii�-leaka96 rate of notreixceedinq 7alr
'a' 'p�r�e�s-s�ur�e�6fb.2:ir�06'w.g��.
c6ngps,perhour6i a an
!pr='RO16RMANCEorthi�gETHdb.Th�-b�il'ai�g�6rdw&flin�,66!t�k'�1:69te'sted4�n�" d' ex�' ding
qyenp�,.,;ks hay!ng'�n�ali leakage i�te of not oe�'
26.'sele6tiv
Adk(��J, viO�,-as'a6wo onFormROO'5- oV. Parfi3rmanc61`orF446G-2017 (ERI), section lab�fleda�i - nfiltrati6n, gub-section ACH56.
-;kO
ACH(�O) spqchledon Form R405-'2017-Energy Catc (Per�ormance),orR406.2017(ERI):
x 60 - 26341 Method for calculating building volu a:
CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans
F]PASS 0 Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation 0 Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNETACC 380 and reported ata pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7). Florida Statues.or individuals licensed as set forth in Section
489.105(3)(% (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode officiaL Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shaJI be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
16. Supply and return registers, if installed at the time of the test, shall be fully open.
OstingiCompany,,
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test.
Printed Name of Tester:
License/Certification #: Issuing Authority:
7/11/2019 3:06:41 PM EnergyGauge@ USA 6.0.03 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page I of I
��5 0 Z Ils
SCANNED
BY
St Lucie County
FYC-Taraba RV
HVAC Load Calculations
for
Synergy Homes, ILLC
4568 Royal Palm Beach Blvd
West Palm Beach, FL 33411
Prepared By:
Ken Fonorow
Florida H.E.R.O., Inc.
15220 NW 6th Ave
Newberry, FI 32669
(352) 472-5661
Thursday, July 11, 2019
-AUG 2 8 2�
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads Elite Sottware Development, Inc.
Florida H.E.R.O.
FYC-Taraba RV
Newberrv. FL 32669
Eage 2
Proiect Report
General Probect Information
Project Title:
FYC-Taraba RV
Designed By:
Ken Fonorow
Project Date:
5/3/2019
Project Comment:
Riverbend Terrace, PSL Revised 7/9/2019
Client Name:
Synergy Homes, LLC
ClientAddress:
4568 Royal Palm Beach Blvd
Client City:
West Palm Beach, FL 33411
Client Phone:
561315-3317
Client E-Mail Address:
deanne@synergyhomesfi.com
Company Name:
Flodda H.E.R.O., Inc.
Company Representative:
Ken Fonorow
Company Address:
15220 NW 5th Ave
Company City:
Newberry, FI 32669
Company Phone:
(352) 472-5661
Company E-Mail Address:
ken@fioridahero.com
Company Website:
www.floddahero.com
I Desian Data
Reference City:
Fort Pierce, Florida
Building Orientation:
Front door faces Southwest
Daily Temperature Range:
Medium
Latitude:
27 Degrees
Elevation:
25 ft.
Altitude Factor:
0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Rulh Rei.Hurn RPI Hurn Dry Bul Difference
Dry
Winter:
Bulb Wet
42 39.4 n/a n/a 72 n/a
Summer:
90 78 59% 50% 75 61
Check Figures
Total Building Supply CFM:
1,200 CFM Per Square ft.: 0.425
Square ft. of Room Area:
2,823 Square ft. Per Ton: 994
Volume (W):
32,431
Building Loads
Total Heating Required Including Ventilation Air: 30,043 Btuh 30.043 MBH
Total Sensible Gain:
26,848 Btuh 79 %
Total Latent Gain:
7,243 Btuh 21 %
Total Cooling Required Including Ventilation Air: 34,091 Btuh 2.84 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
I
C:\Users\OwnerXDesktop\All Rh Files\All rh9 findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM
Rhvao - Residential & Light Commercial HVAC Loads
Elite Sottware Development, Inc.
Florida H.E.R.O.
FYC-Taraba RV
Newberm EL 32669
Page 3
Miscellaneous Report
System 1 Whole House Outdoor
Outdoor Outdoor Indoor Indoor Gr n:
InDut Data Dry Bulb
Wet Bulb Rel.Hum Rel.Hum ON ulb Differen c
Winter: 42
39.4 80% n/a 72 n1a
Summer: 90
78 59% 50% 75 61.09
Duct Sizing Inputs
Main Trun
Runnut
Calculate: Yes
Yes
Use Schedule: Yes
Yes
Roughness Factor: 0.15000
0.15000
Pressure Drop: 0.1000 in.wg./l 00 ft.
0.1000 in.wg./l 00 ft.
Minimum Velocity: 650 ft./min
450 ft./min
Maximum Velocity: 900 ft./min
750 ft./min
Minimum Height: 0 in.
0 in.
Maximum Height: 0 in.
0 in.
F r Data
Winter
Infiltration Specified: 0.220 AC/hr
Surnme
0.110 AC/hr
119 CFM
59 CFM
Infiltration Actual: 0.282 AC/hr
0.000 AC1hr
Above Grade Volume: X 32,431 Cu.ft.
X 32 431 Cu.ft.
9,132 Cu.ft./hr
X 0-0167
0 Cu.ft./hr
X D 0167
Total Building Infiltration: 152 CFM
0 CFM
Total Building Ventilation: 0 CFM
95 CFM
--System I —
Infiltration & Ventilation Sensible Gain Multiplier: 16.49
= (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 41.50
= (0.68 X 0.999 X 61.09,Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 32.97
= (1. 10 X 0.999 X 30.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.220 AC/hr (119 CFM), Construction: Semi -Tight
Summer Infiltration Specified: 0. 110 AC/hr (59 CFM), Construction: Semi -Tight
C:\Users\Owner\Desktop\Ail Rh Files\All rh9 findings�FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM
Rhvac - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Florida H.E.R.O.
FYC-Taraba
RV
Newberry. FL 32669
Eage 4
DUCt Size Preview
Room or
Source
I
Minimu
Maxim
Rough
Des! SP
Du
Du
H
t
Duct Name
Velool
Velooll
Factol
U1901 Loss
Velocit Lengt
Fh
Svstern 1
Supqly�Runouts
Zone 1
Built-in
0.15
358.4
141,
2-f
1-Master Bedroom
2-Master VVIC 1
Built-in
750 0.11
'__ - . -_ - t- I
750 0.15 OA
174.6
117
1 50
-------- -
1
- -
1-4
3-Master WC 2
Built-in
45d
750 0.15
_16.i
4__
20M
2
__1:4
4-Master Bath
-450'
750 0.15 0.1�
336.7,____
141OW63
66'
1-6
5-Master Bath WG -
I Built-in
45 - 0
750 -0.15,--- 0.1
208.3---
1-20m,
-
181�
1-4
6-Den
450
750 0.15 0.1
337.5
SOWFal
661
1__6
_;_Built-in
7-Foyer
I Built-in
45d
*0 0.15'
348.1
48
O-Great Room
Bullt-1 n
450--_
-0.1
75d 0.15 0.1�_
629.2
__21,0_ _1-4
336'
2-7
9-Dininq
-
Built-in
450
750 0.15 0.1
435.1
__1341ffM31__
1391W8
-
851
1-6
10-Kitchen
'Built-in
450
75Q 0.15 0.1
525.6
20 Q3,
jjjVl
1 103
-7
1_6
11 -Pantry
Built-in
450
F
750 0.15 ____O.i 801
I I
24 M'
: 7]
_7
1-4
12-Bedroom 2
Built -In
45d
0.15 0.1
339.6'
57
67
1__G
Built-in
450
7, 019 Of
566.�
87 ZZ n4'
4��
11
-13-Utilitv -
14-Bath 2
15-Bedroom 3
Built-in
t P- tfit In 1
450 1
45Q
7 015 Oil
75 0.15 0.1
171.9
-
352.5
35
73MNM�_
15
69
_�66"
-4
16-Bedroom 4
Built-in
45d
75 0.1� 0.1
334.3
53
43 1
ill
1-4
17-Bedroom 4 VVIC
-
Built-in
45d
75Q 0.15 0.1
129.5
-
_4
- __
18-Bath 3
1 Built-in
I---
450
75 0.4' 0.1 1j
591.8
55 6
i 521
1-4
Other Ducts In yelem 1
S
j
Suppiv Main Trunk
Built-in 1
650
900 0.15 0.1
675
11200197206
1,200
16XIE
Summary
Svstem 1
Heatina Flow: 1200
Coolino Flow: 1200
CA1Jsers\OvvnerNDesktop\All Rh Files\All A9 findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM
Rhvac - Re Idential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Florida H.E.R.O.
FYC-Taraba RV
Newberry. FL 3209
Total Buildini:7 Summaty Loads
Component
Area Sen Lat Sen Total
Description
Quan Loss Gain Gain Gain
1 OC-f: Glazing -French door, double pane low-e glass (e
24 324 0 1,116 1,116
0.40), insulated fiberglass frame, ground reflectance
= 0.32, U-value 0.45, SHGC 0.43
VYN 34 23: Glazing-Dbl Pn Vyn Fr U.34 SHGC.23,
16 163 0 305 305
ground reflectance = 0.23, U-value 0.34, SHGC 0.23
VYN 34 23: Glazing-Dbl Pn Vyn Fr U.34 SHGC.23,
82.5 842 0 1,304 1,304
ground reflectance = 0.23, outdoor insect screen with
50% coverage, medium color blinds at 45'with 25%
coverage, U-value 0.34, SHGC 0.23
VYN 34 23: Glazing-DbI Pn Vyn Fr U .34 SHGC .23,
4 41 0 71 71
ground reflectance = 0.23, U-value 0.34, SHGC 0.23
VYN 34 23: Glazing-DbI Pn Vyn Fr U.34 SHGC .23,
16 153 0 134 134
ground reflectance = 0.32, outdoor insect screen with
50% coverage, U-value 0.34, SHGC 0.23
VYN 34 23: Glazing-DbI Pn Vyn Fr U.34 SHGC.23,
54 551 0 1,296 1,296
ground reflectance = 0.32, U-value 0.34, SHGC 0.23
1OC-f.' Glazing -French door, double pane low-e glass (e
96 1,296 0 3,892 3,892
0.40), insulated fiberglass frame, ground reflectance
= 0.32, medium color blinds at 45* with 25%
coverage, U-value 0.45, SHGC 0.43
VYN 34 23: Glazing-DbI Pn Vyn Fr U.34 SHGC.23,
30 306 0 210 210
ground reflectance = 0.32, outdoor insect screen with
50% coverage, medium color blinds at 45* with 25%
coverage, U-value 0.34, SHGC 0.23
VYN 34 23: Glazing-Dbl Pn Vyn Fr U .34 SHGC .23,
15 153 0 283 283
ground reflectance = 0.23, outdoor insect screen with
50% coverage, U-value 0.34, SHGC 0.23
VYN 34 23: Glazing-Dbl Pn Vyn Fr U.34 SHGC.23,
4 41 0 84 84
ground reflectance = 0.23, outdoor insect screen with
50% coverage, U-value 0.34, SHGC 0.23
I OC-f.' Glazing -French door, double pane low-e glass (e
21.4 288 0 866 866
0.40), insulated fiberglass frame, ground reflectance
= 0.32, medium color blinds at 450 with 50%
coverage, U-value 0.46, SHGC 0.43
11 P: Door -Metal - Polyurethane Core, U-value 0.29
61.4 534 0 463 463
13A-6ocs: Wall -Block, board insulation only, R-6 board
2140.3 7,125 0 3,158 3,158
insulation, open core, siding finish, U-value 0. 111
12C-Osw: Wall -Frame, R-1 3 insulation in 2 x 4 stud
110 300 0 215 215
cavity, no board insulation, siding finish, wood studs,
U-value 0.091
ISAl-21o: Roof/Ceiling-Roof Joists Between Roof Deck
3069.4 4,327 0 3,750 3,750
and Ceiling or Foam Encapsulated Roof Joists,
Spray Foam Insulation, Dark or Bold -Color Asphalt
Shingle, Dark Metal, Dark Membrane, Dark Tar and
Gravel, R-21 open cell 1/2 lb. spray foam, 5.5 inches
in 2 x 6 joist cavity, 1 inch on joist, U-value 0.047
16B-19: Roof/Ceiling-Under Attic with Insulation on Attic
145 213 0 355 355
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-19 insulation, U-value 0.049
22A-pl: Floor -Slab on grade, No edge insulation, no
282 8,366 0 0 0
insulation below floor, any floor cover, passive, light
y so -value 0.989
—dr Jil U
Subtotals for structure:
25,023 0 17,502 17,502
People:
6 1,200 1,380 2,580
C:%Users\Owner\Desktop\A]I.Rh Files\All.rhg findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM
Rhvac; - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Florida H.E.R.O.
FYC-Taraba RV
blewbg[ry, FL 32669
Eage 6
Total Buildiag Summary Loads (contd)
t Area
Sen
Lat
Sen Total
I Quan
Loss
Gain
Gain Gain
Equipment:
2,100
6,400 8,500
Lighting: 0
0 0
Ductwork:
0
0
0 0
Infiltration: Winter CFM: 152, Summer CFM: 0
5,020
0
0 0
Ventilation: Winter CFM: 0, Summer CFM: 95
0
3,943
1,566 5,509
-Exhaust., W*interCFM."95,.Summ.e-rC-FM.:O--.
Total Building Load Totals:
30,043
7,243
26,848 34,091
Check Figures
Total Building Supply CFM: 1,200 CFM Per Square ft.:
0.426
Square ft. of Room Area: 2,823 Square ft.
Per Ton:
994
Volume (W): 32,431
-7:71
Building Loads
Total Heating Required Including Ventilation Air: 30,043 Btuh
30.043
MBH
Total Sensible Gain: 26,848 Btuh
79
%
Total Latent Gain: 7,243 Btuh
21
%
Total Cooling Required Including Ventilation Air: 34,091 Btuh
2.84
Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturers performance
data at
your design conditions.
C:\Users\Owner\Desktop\All Rh Files\All rh9 findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. I J
Florida H.E.R.O. FYC-Taraba RV I
Cooling
System Type:
Outdoor Model:
Indoor Model:
Tradename:
Outdoor Manufacturer:
AHRI Reference No.:
Capacity:
Efficiency:
Heating
System Type:
Model:
Manufacturer:
Capacity:
Efficiency:
Standard Air Conditioner
4TTR40371-11
TAM9AOC36V31
TRANE
TRANE
10093791
35,000
16 SEER
Electric Resistance
TAM7AOC36
Trane
31
0%
This system's equipment was selected in accordance vvith ACCA Manual S.
Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODS: 42F, SIDB: 75F, SIRH: 50%, WIDB: 72F, Sen. gain:
26,848 Btuh, Lat. gain: 7,243 Stuh, Sen. loss: 30,043 Btuh, Entering c1g. coil DB: 76.2F, Entering c1g. coil VVB: 64F,
Entering htg. coil DB: 72F, CIg. coil TD: 20F, Htg. coil TD: 70F, Req. cIg. airflow: 1150 CFM, Req. htg. airflow: 391 CFM
C:\Users\Owner\Desktop\All Rh Files\All rh9 findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM
Rhvac - Residential & Light Commercial HVAC Loads
Elite
Software Development, I c.
Florida H.E.R.O.
FYC-Taraba RV
Newberry, FL 32669
page A
system 1 Room Load Summa1y
-1
Htg Min
Run
Run
Clg
CIg
Min
A
Room
Area
Sens Htg
Duct
Duct
Sens
Lat
CIg
No Name
SF
Btuh CFM
Size
Val
Btuh
Btuh
--- Zone 1-
1 Master Bedroom
368
3,690 48
2-6
358
2,965
400
135
141
2 Master WIC 1
84
1,243 16
1-4
175
321
0
15
15
3 Master WIC 2
36
56 1
1-4
27
49
0
2
2
4 Master Bath
224
3,527 46
1-6
337
1,393
450
63
66
5 Master Bath WC
18
295 4
1-4
208
383-
550
17
18
6 Den
172
2,013 26
1-6
337
1,396
0
64
66
7 Foyer
78
1,193 16
1-4
348
640
0
29
30
8 Great Room
420
3,354 44
2-7
629
7,085
600
322
336
9 Dining
185
3,469 45
1-6
435
1,800
0
82
85
10 Kitchen
330
512 7
1-6
526
2,174
550
99
103
11 Pantry
42
607 8
1-4
80
147
0
7
7
12 Bedroom 2
182
1,416 18
1-6
340
1,405
0
64
67
13 Utility
124
2,172 28
1-4
566
1,041
250
47
49
14 Bath 2
81
864 11
1-4
172
316
250
14
15
15 Bedroom 3
207
1,827 24
1-6
352
1,458
0
66
69
16 Bedroom 4
186
1,338 17
1-6
334
1,383
0
63
66
17 Bedroom 4 WIC
42
1,085 14
1-4
129
238
0
11
11
18 Bath-3---
45
1,382 IS
1-4'
592
1�088
250
49
52
Ventilation
0
1,566
3,943
-Systern 1 total
823._
30,043 391
26848 7,243_1,150
1,200
System 1 Main Trunk Size:
16xl6 in.
Velocity:
675 ft./min
Loss per 100 ft.:
0.238 in.wg
Cooling System Summary
Cooling
Sensible/Latent
Sensible
Latent
T olal
Tons
Split
Btuh
Btuh
Btuh
Net Required:
2.84
79%/21%
26,848
7,243
34,091
Actual:
2.92
77%/23%
26,950
8,050
35,000
Equipment Data
Type:
Heating System
Electric Resistance
Cooling Syste
Standard Air Conditioner
Model:
TAM7AOC36
4TTR40371-11
Indoor Model:
TAM9AOC36V31
Brand:
TRANE
Efficiency:
0%
16 SEER
Sound:
0
0
Capacity:
31 Btuh
35,000 Stuh
Sensible Capacity:
n/a
26,950 Btuh
Latent Capacity:
n/a
8,050 Btuh
AHRI Reference No.:
n1a
10093791
This system's equipment was selected
in accordance vvith ACCA Manual S.
Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB:
72F, Sen.
gain:
26,848 Btuh, Lat. gain: 7,243 Btuh, Sen. loss: 30,043 Btuh, Entering cIg.
coil DB:
76.2F, Entering
c1g. coil WB: 64F,
Entering htg. coil DB: 72F,
Cig. coil TD: 20F, Htg. coil TD: 70F,
Req. c1g.
airflow:
1150 CFM, Req.
htg.
airflow: 391 CFM
C:\Users\Owner\Desktop\A[I.Rh Files\All.rh9findings\FYC-Taraba RV.rh9 Thursday, July 11, 2019, 3:10 PM