Loading...
HomeMy WebLinkAboutTRIANGLE TESTING LAB PAPERWORKW-o TRIANGLE TESTING LAB, INC. CoA#31 01 4750 ROYAL PALM BEACH BOULEVARD WEST PALM BEACH, FLORIDA 33411 (561)790-3049 e-mail: triangle2992(dqmaii.com Date: October 17, 2019 -SCANNED To: The City of Port St. Lucie Building Department BY Re: Soil Compaction Report -Density of In -Place Compacted Soil Lucie Counti SYNERGY HOMES - RESIDENCE 12192 RIVERBEND TRACE PORT SAINT LUCIE, FL Test Date Test # Test Location Elevation In -Place Readings MMPD Values % Density Moisture Density Moisture 10/16/19 1 Southeast Area 1'-2' 105.8 7.4 109.5 6.6 96.6 10116/19 2 Center Area 0-11 106.5 6-8 109.6 5.6 97.3 10/16/19 3 Northwest Area t 1-2' 1 105.9 7.1 109.5 6.6 96.7 Remarks: All elevations are measured from top of pad grade. (Mod Proctor Test #1) Verffication Statement This statement shall serve as verification that the soil beneath the proposed structure has been tested in accordance with Section R401.4 of the 2017 Florida Building Code, Residential edition. The tests were conducted from the existing grade. Density tests were taken at a minimum of three (3) locations throughout the total depth of fill. The depth of fill was approximately 2.0 feet. The foundation setbacks were based on information furnished by the client, at the time of testing. Based on the location and depths tested, we verify that the fill has been compacted to a minimum of 95% of the maximum dry density as determined by ASTM D-1 557 and that the minimum soil bearing value beneath the proposed foundation area is 2.500 Dounds Der sauare foot. Respectfully submitted, NS C, 0 Richard Boyette, FL PE #42485 Vice President ov cc Lij Z October 17, 2019 V File # 21546 N""' Permit # 1908-0177 N4 OCT 2 4 2019 Permitting Department St. Lucie County, FL