HomeMy WebLinkAboutSURVEYI 1K
t
Ln
0
0
00
I'
Ln
E OF LOT 10. BLOCK 2
(VACANT)
NORTHWEST CORNER
SECTION 25/36/40 N88e0815719W
H
------------------------
112.2'
------}--------IS1Ji'-------------------
---------- 16351'------------------------�
loca-ViE,n aw(xrd
cuSF�er • _
I
rn
J
1"
360.00' FIRC
FORM BOARDS
TOP OF FORM
ELEV =54.61
S88008'5799E
I (VACANT)
CERTIFICATION
I hereby certify that the survey represented hereon was performed under
my supervision and it complies with the minimum technical standards, as
set forth by the Florida Board of Surveyors & Mappers in Chapter
61GW-6 of the Florida Administrative Code, pursuant to.Section 472.027,
Florida Statutes, and further that there are no visible, �bcve ground
encroachments unless shown or noted.
MARCH 9, 2007
Date of Signature WILLIAM B. ENNETT
Pro rveyor & Mapper
Florida Certificate No. 6353
LB No. 7235
,
,
,
,
,
i
,
,
360.009
1
,o
,o i
coly
i
i
t; EON;1 �
f C4R SIDE
EREAR 1 D
ZKIG.
3 TEC .
LEGEND
DUE =
DRAINAGE & UTILITY EASEMENT
FIN =
FOUND
OHE =
OVERHEAD UTILITY LINES
IR =
IRON ROD
FIRC =
FOUND IRON ROD & CAP
SIRC =
SET IRON ROD & CAP
R/W =
RIGHT-OF-WAY
(P) =
PLAT DIMENSION
M =
MEASURED DIMENSION
PK =
PK NAIL & DISK
N TT =
NAIL & TIN TAB
® =
DRAINAGE MANHOLE
Q =
SANITARY SEWER MANHOLE
30,
I m
lbCA
IDo
Z
0
I>� m
rn y I .
rDjl j
rn
mR m
lI
T
i 0n
OR
I��
100 U'
N
Itn m <y
II z
I =�
IW m
I
W
10 x
100
10
I
I =
m
i I
I m
I
J =
m
WPP &
ANCHORS
-(?=
FIRE HYDRANT
0 =
WOOD POWER POLE
X =
TELEPHONE RISER
♦ =
WATER METER
X =
CABLE TELEVISION RISER
D4 =
WATER VALVE
E =
POLE ANCHOR
WPP =
WOOD POWER POLE
WM =
WATER METER
CL =
CENTERLINE
EOW =
EDGE OF WATER
TOBB =
TOP OF BANK
cap
y =
SPOT ELEVATION
4
8
RECEIVED
MAR 2 0 2007
Public Works
St. Lucie County, FL
SITEi A
Location Map
(Not To Scale)
LEGAL DESCRIPTION:
ST. LUCIE GARDENS 25-36-40, Block 2, North 330 feet of Lot 10, Less
the East 330 Feet,as recorded in Plat Book 01, at Page 035, of the public record;
of St. Lucie County, Florida.
LOT AREA: 2.75 Acres± STREET ADDRESS: Dyer Road, Port St. Lucie, FL
SURVEYORS' NOTES:
1. Bearings shown hereon are based on the centerline of Dyer Road as platted
and is assumed to bear N00'18'25"E.
2. Written dimensions take precedence over scaled dimensions and distances are
not to be scaled for construction and/or design purposes.
3. All distances and bearings are as field measured and are coincident with
'PLAT" and description data unless otherwise noted.
4. This drawing is not valid without the signature and original raised seal of a
Florida licensed Surveyor & Mapper.
5. This survey is based upon a description furnished by the client, there has
been no search of the public records done by this office.
6, Property lies in Flood Zone "X" as scaled from the National Flood Insurance
Program Rate Map, Community Panel Number 12111CO263 F. with an effective
date of August 19, 1991.
7. Water & sewer are not available in this area.
8. Elevations shown hereon are based upon an assumed datum.
CERTIFIED TO: SCANNED
S. GREENE; SY
HARBOR FEDERAL SAVINGS BANK; St. LucileO®unN
SUN TITLE, AND ABSTRACT CO.;
UNITED GENERAL TITLE INSURANCE CO.;
or FIDELITY NATIONAL TITLE INSURANCE CO. OF N.Y. and
JPG ENT INC. MAJESTIC HOMES.
Revised: Form board tie-in. WBB, 03-09-07. ;1uM- *Owe - oS )�
Date of Last field work:03/07/2C
,,ennett
Form Board Tie —In Survey
,arod on the order of;
Bennett Surveying +Mapping
439 S.E. Port St Lucie Boulevard Unit 107 Reid:
Port St Lucie, Florida 34984
tel:-772.336.4933 fax: 772.336.8689 Drawn:
email: wbennettdd®cs.com Scaler
S., Greene
M/JD I Job
WBB I Date: