HomeMy WebLinkAboutPRODUCT APPROVALS5/15/2019 Florida Building Code online
EMS Home ug in I User Registration I.Ho[hplcs I submit Su¢harge I State &Fasts Publications I Corti Us I BCIS Ste Map I links I Search
Florida
, •` '� Yam) Product Approval
D USER: Public User
'= proval ro Protlu¢ ApMenu > PtluR or Aoplica[Ion search > Application List > implication Detail RECEIVED
A: FL# FL5259-1128 SCANNEDAUG 0 9 2019
f A type PPlication YP Revision - Code -Version - - 2017- - - BY — -ST. Lucie-County,-Permittin]- -
Application Status Approved St Luc/p_ r'(tnnP ai
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
POLYGLASS USA l
1111 W. Newport Center Drive P9C\0��\WIE�^3�t �',tP1�i�
REVIEWED ED OR
Deerfield Beach, FL 33442
(954) Ext242
O P I CE
CODE COMPLIANCE
malpert@polyglass.com
ST. LUCIE COUNT/
Maury Alpert
malpert@polyglass.com
BOCC
az>
Maury Alpert
•
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912) 429-8610
MAlpert@polygiass.com
Ariel Lender
1111 W. Newport Center Drive �l{lep�
Deerfield Beach, FL 33442 _ ®pqj
(954) 233-1230
ALender@ polyglass.com
Roofing
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
- Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name
who developed the Robert Nieminen
Evaluation Report
Florida License
PE-59166 ?X
Quality Assurance Entity
'UL LLC
- -
Date 09/13/20J
John W. Kin
y Validati
1-L5259 R;
idard) Standard
�r
ASTM Dl�
ASTM D2:
rv' "` ..�.. S'...-". .YL:d.. P y� ^, t''U •e'1'is"r_.:.. s... ASTM D4i
ASTM D6]
ASTM D6:
FM 4474
FRSA/TRI
t NStreamislus Promos
https://www.floddabuilding.org/pr/pr app_dfl.aspx9param=wGEVXQwtDgvbSgAaZp3Crk2vSn/e2fegOlipJYmiSimiPV6uypRuXszPog°/g3d°/a3d 112
5/1512019 . - Florida Building Cade Online
UL 1897 _.. 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 01/24/2018
Date Validated 01/29/2018
-- - - - - - - - Date Pending FBC Approval - -- - - -- - - 01/30/2018 - - - - - - - - -- -- — - - -
Date Approved 04/10/2018
Summary of Products
FL #
be
Description
9.1
_Polyglass Roof
Ping underlayments
-
Un erld laymen
Limits Limits of Use
Installation Instructions
roved for : No
FL5259 R28 II 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
Approved for use outside,HVHZ: Yes
R28.odf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
Evaluation Reports
application relates to one particular
FL5259 R28 AE 2018 Ol FINAL ER POLYGLASS UND RLAYMENTS 5259-
underlayment system (over concrete deck) for
R28.pdf
use under foam -on file systems (where the
Created by Independent Third Party: Yes
underlayment forms part of the load -path).
Refer to ER Section 5.6.4 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
Fie-1 Nazi
Contact Us :: 2601 alai Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Flarida is an AWEEO employer. Coavright 2007-2013 State of Florida.:: Privac, Statement :: Acm sibirty Statement :: Refund Statement
Under Florida law, email addresses are public retards. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail W this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Nmuant to section 455.275(1),
Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for olfival communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public To determine If you are a licensee under Chapter 455, F.s., please dick heM.
Product Approval Accepts:
M ® eCkcl W
Credit Card
Safe
https:IANww.loridabuilding.org/pdpr app_dfi.aspx?param=wGEVXOwtDgvbSgAaZp3Crk2vS%2feg01ipJYmiSimlPVBuypRuXszPog%3d%3d M
2/4/2019 Florida Building Code Online
— :3
1 , A .✓ £I tl..w.> � '¢„ey.ct'}.�M° �, .t;�t .^!^A MI L �r"t Y. 4"p Met.+ -
VIE
�. ..... L��..� rv:.-ry e_.
BCIS Home I Lag In User Reglia atimi Hat Topa Submit Surcharge 1 scats a Facts j Publications i contactm I Ms Site Map i ❑ak I V search j
Fiorioa ��pp
t product al
_e.al
icUw
'! USER: Publi<User
PmduR Aoyroval Menu > Product or ApylicatMn Seamh > Ap_pllratiAn List> Application Detail
FL #
F1-17022-117 SCANt
Application Type
Revision �/
BY
Code Version _
_ _ 2017 S}. LUC1
l
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
08/18/2017v. date reapply 08/21/17
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
fivalidation@ya hoo.com
REVI��E,WE��DooF®K
COL. E 1.rOAY1PL'/' NCt.
ST. LUCIE COUN" ti `r
SOCC
RECEIVED
AUG 0 9 2019
ST. Lucie County, Permitting
V
Richard McKuhen
fival idation@yahoo. com
Richard McKuhen
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
richard@emfab.net
Roofing
Metal Roofing
—A' I
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
04/2212024
Validated By
Zachary R. Priest, P.E.
-� Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL17022 R7 COT FL 17022.1 S V CRIMP ssr. pdf
Standard
TAS 125
UL 1897
UL 580
Year
2003
2012
2006
https:!/www.floridebuilding.orglpr/pr app dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 113
2/4/2019
Florida Building Code Onlir,
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
08/18/2017
08/25/2017
08/28/2017
10/10/2017
R I Mo her or Name ascription
17022.1 +..-
24" wide lapped roof panel
-plywood orWood Deck with
Limits of Use
Approved for use in HVH
Inst ructions -�
Approved for use outside HVHZ: Yes
FL17022 R7 li FL 17022 1 5 V CRIMP ssrpdF
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions. Install the
Evaluation Reports
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr df
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation Instructions.
17022.2 2 - "SV Crimp" (R6) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
EL17022 R7 II FL 17022 2 5 V CRIMP 0,032 ALUM ssr pdf
Impact Resistant: No
Verified
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
by Independent Third Party: Yes
Evaluation Reports
Other: Refer to evaluation report for mnditions.Install the
assembly in compliance with the Installation method listed
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 AlIIM ss pdf
in
this report and applicable cotle sections of FBC. Refer to
Created by Independent Third Party: Yes
manufacturer's installation instructions.
17022.3 3 - "1.5° Mechanical Seam" (RS) 11.5" rib height, 16' wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL17022 R7 If FL 17022.3 1.5 MECHANICAL
Impact Resistant: No
seam 24ga ssr pdf
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
of use. Install the assembly in compliance with the installation
FL17022 R7 AE FL 170223 1.5 MECHANICAL
method listed in this report and applicable code sections of
seam 24g ssr.Wdf
FBC. Refer to manufacturer's installation instructions.
Created by Independent Third Party: Yes
17022.4 4 - "LS" Mechanical Seam" (RS) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to 15/32" plywood or Wood Deck
with dips and fasteners.
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL17022, R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes ALUMINUM ssr pdf
Impact Resistant: No Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations Evaluation Reports
of use. Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
method listed in this report and applicable code sections of ALUMINUM ss�pdf
FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes
17022.5 15 - "1 in. Nail Strip" (RS) 1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly In compliance with the installation
Installation Instructions
FL17022 R7 II FL 17022 5 1,9 UAILSTRIP ssrpdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr cad
Created by Independent Third Party: Yes
https://www.fioddabuilding.org/pr/pr app dtl.aspx?param=WGEVXQwtDgv2aBQPHpQQe6rM7MkUEoR°/a2bGxHGxFe5QkCHzEgvOQveeg%3d°/a3d 2/3
2/4/2019
Florida Building Code Online
method listed In this repan apd applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.6
6 - "1 in. Nail Strip" (RS)
1" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
Limits of use
Installation Instructions
Approved for use In HVHZ; No
Approved for use outside HVHZ: Yes
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0,032
ALUM ssr.pdf
Impact Resistant: No
Design Pressure: +N/A/ Table A
Other: Refer to evaluation report for conditions and limitations
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party- Yes
Evaluation Reports
of use. Install the assembly In compliance with the installation
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0,032
ALUM ssrpd
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation Instructions.
Created by Independent Third Party: Yes
17022.7
7 - '1.5 In. Nail Strip" (RS)
1.5" rib height, 19" wide, 26 _gauge. steel, standing seam roof
- -
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 IT FL 17022.7 1.5 Nail Strip 26GA ssrod
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report for Conditions and limitations
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssrodf
Created by Independent Third Party: Yes
of use. Install the assembly in compliance with the installation
method listed in this report and applicable Code sections of
FBC. Refer to manufacturer's installation instructions.
17022.8
8 - "EMAX Rib" (R5)
29 gauge steel, lapped roof panel mechanically attached to
1S/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R7 If FL 177022.8 EMAX Rib ssrodf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report for Conditions and limitations
FL17022 R7 AE FL 177022.8 EMAX Rib ssr.pd
of use. Install the assembly in compliance with the installation
Created by Independent Third Parry: Yes
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation Instructions.
f
17022.9
9 - " PBR MAX' (RS)
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 IT FL 17022.9 PBR RIB ssr.pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report far conditions and limitations
FL17022 R7 AE FL 17022.9 PBR RIB ssr.pdf
of use. Install the assembly in compliance with the installation
Created by Independent Third Party: Yes i
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
Eq FV—.71
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an ANEW employe[ Copyright 2007-2013 State of Marine :: PrNmy Statement :: Aomssibility Statement :: Refund Stateme
Under Florida law, email addresses are public records, a you do not want your e-mail address released In response M a public -records request, do not send electronic
mat] to this entity. Instead, contact the Grace by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.27S(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. most provide the Department with an email address if they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
EM
O ® Fog
Credit Card
'Safe
https://www.floddabuilding.orgfprlpr app dill.aspx7param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 3/3
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications -
Pro uct: 5AftCrimpZ6GA.5te_ e_ oof Pa FBC Sec. 1507.4.2
Yield strength: 50 ksi ., tta hed to min.15/32" plywood or Wood
Dec w min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" o.c.
16" D.C.
8" D.C.
6" D.C.
FASTENER SPACING (ALONG Panel width)
12" D.C.
12" o.c.
12" D.C.
12" D.C.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL 580-06 & 1897-04i Test Report EM893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-15 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1Ty *Design
pressure margin of safety 2:1
Locke Bowden, P.E. does not have, not will acquire a financial
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by e
report.
B p�
colApadvombb9flaturer, or
o' e
NA4
or distributing products
Products under this
Limitations: FL17022.1 5v Crimp (26GA Steel), 24" Wide Ro` .-lanes -Details
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ed.
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.,
6. Support framing in compliance w1FBC 2017 6U, ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
99.1-112"Min. or
#10•1-112"Mh perTaWe A"PorRow 5V Cdap Rod Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
Deck
-15W crgreater PVwcod, cr
- Wood plank
3<�
OPRONALSTRIATIONS
Panel Profile
Nominall2" Nominall2"
O.C. o.c.
Fasten
9 x -112" Min. or #10 x 1-112" Min. per
"fable "A" Hex Washer Head Screw
Panel Spaced 12" o.c. across the Panel Width
Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15132" or greater
Plywood, or