Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEF01 r,M R40Er2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JOHN & LISA WISWELL Builder Name: -Street: 0 DYER ROAD SCANNED Permit Office: ST. LUCI COUNTY City, State, Zip: PORT ST. LUCIE, FL, Permit Number: AUG n 9 -"i1q O� Owner: JOHN & LISA WISWELL Y St. Jurisdiction: Design Location: FL, Fort Pierce Lucie County County: St. Lucie FSTNALUWIBiRsURt1�-, MaYmlct(no r 1. New construction or existing New (From Plans) 9. Wall Types (1116.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1116.00 ft2 3. Number of units, if multiple family 1 b. NIA c. N/A R= ft2 R= ft2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (752.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 752.00 11:2 6. Conditioned floor area above grade (112) 752 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 0. N/A R= ft2 7. Windows(111.3 sqft.) Description Area 11. Ducts a. Sup: Attic, Rat: Attic, AH: Attic R 112 6 150 a. U-Factor: Sgl, U=0.65 56.00 ft2 SHGC: SHGC=0.30 b. U-Factor. Sgl, U=0.65 55.33 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 17.6 SEER:16.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 7.353 ft. Area Weighted Average SHGC: 0.275 14. Hot water systems 3. Floor Types (752.0 sqft.) Insulation Area a. Electric Cap: 50 gallons _ a. Slab -On -Grade Edge Insulation R=0.0 752.00 f' b. Conservation features EF: 0.950 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.148 Total Proposed Modified Loads: 32.02 PASS Total Baseline Loads: 34.26 I hereby certify that the plans and specifications covered by Review of the plans and S7,f?� this calculation are in compliance with the Florida Energy specifications covered by this �F'S1iE ♦ _ p Code. calculation indicates compliance with the Florida Energy Code. !~ nn„> ••,' ;;€r''x°„ �p PREPARED BY:p Before construction is completed DATE: $-$- l9 this building will be inspected for ?II y compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. �t with the Florida Energy Cod CpD WS OWNER/AGENT: // ff BUILDING FBI 'tearv�4 W DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACIREV9 n D FOR CODE COMPLIANCE ., ST. LUCIE COUNTY BOCC 802019 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHFCICI I--ST RFI3n17T PROJECT Title: JOHN & LISA WISWELL Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 752 Lot # Owner Name: JOHN & LISA WISWELL Total Stories: 1 Block/Subdivision: - # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 0 DYER ROAD Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: PORT ST. LUCIE Family Type: Single-family FL, . New/Existing: New (From Plans) Comment: CLIMATE / V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 752 6768 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 WIC 52 468 No 0 1 Yes Yes Yes 2 BATH 88 792 No 0 1 Yes Yes Yes 3 BEDROOM 187 1683 No 2 1 1 Yes Yes Yes 4 KITCHEN/LIVING 425 3825 Yes 2 1 Yes Yes Yes l FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio WIC 16 ft 0 52 W -_ 0 1 0 2 Slab -On -Grade Edge Insulatio BATH 19 ft 0 88 W — 0 1 0 3SIab-On-Grade Edge Insulatio BEDROOM 22 ft 0 187 ft- -_ 0 1 0 48Iab-On-Grade Edge Insulatio KITCHENILIVING 67 It 0 425 W _ 0 1 0 ROOF / V Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Bart Absor. Tested Tested Insul. (deg) 1 Hip Metal 775 ft' 0 ft' Light N 0.5 No 0.9 No 20 14 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 752 ft' N N 8/8/2019 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ,♦ v CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type ^_ 1 Under Attic (Unvented) WIC 0 Blown 52 ft' 0.1 Wood 2 Under Attic (Unvented) BATH 0 Blown 88 ft' 0.1 Wood _ 3 Under Attic (Unvented) BEDROOM 0 Blown 187 ft' 0.1 Wood 4 Under Attic (Unvented) KITCHEN/LIVING 0 Blown 425 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o _ _ 1 NE Exterior Concrete Block - Ext Insul WIC 4.1 6 0 9 0 54.0 W 0 0 - 0.6 0 _ 2 SE , Exterior Concrete Block - Ext Insul WIC 4.1 1 0 9 0 9.0 ft' 0 0 0.6 0 3 NW Exterior Concrete Block -Ext Insul WIC 4.1 9 0 9 0 81.0 ft' 0 0 0.6 0 -4 NE Exterior Concrete Block - Ext Insul BATH 4.1 11 0 9 0 99.0 ft' 0 0 0.6 0 _ 5 SE Exterior Concrete Block - Ext Insul BATH 4.1 8 0 9 0 72.0 ft' 0 0 0.6 .0 -6 SE Exterior Concrete Block - Ext lnS®EDROOM 4.1 11 0 9 0 99.0 tt' 0 0 0.6 0 -7 NW Exterior Concrete Block - Ext Ins®EDROOM 4.1 11 0 9 0 99.0 ft' 0 0 0.6 0 -8 SE Exterior Concrete Block - Ext IniUTCHEN/LIV 4.1 25 0 9 0 225.0 ft' 0 0 0.6 0 -9 SW Exterior Concrete Block- Ext In*UTCHEN/LIV 4.1 17 0 9 0 153.0 ft' 0 0 0.6 0 10 NW Exterior Concrete Block - Ext Inl111fCHEN/LIV 4.1 25 0 9 0 225.0 ft' 0 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated KITCHEN/LIV None .39 3 6 8 20 ft' WINDOWS - Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 3 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft' 5 It 0 in 1 It 4 in None None 2 SE 5 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft' 2 It 0 in 1 ft 4 in None None 3 NW 7 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft' 5It 0 in 1 It 4 in None None 4 SW 9 Metal Low-E Single Yes 0.65 0.3 N 56.0 ft' 10 ft 0 in 1 ft 4 in None None 5 NW 10 Metal Low-E Single Yes 0.65 0.25 N 28.3 ft' 5 ft 0 in 1 It 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 789.6 43.35 81.52 .1454 7 8/8/2019 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHFCKI 1ST RFPART -- — HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 17.6 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM - # _System Type. SubTpe. .Location _ EF Cap Use SetPnt Conservation 1 Electric None BEDROOM 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS _ / —Supply— --Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ft' Attic 65 ft' - Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablfe'Thermostat: Ceiling Fans: '�Y r' • Heat ng Jan IXI Feb [X] Mar N € Jul May nIrXI[X i � �X� ct �X� Nov Dee Venting [ 1 Jan II 11 Feb Mar I 1 lx� l�l �] Apr May Jun [ Jul [ Aug Sep OctX Nov Dec Thermostat Schedule: HERS 2006 Reference Hours JSchedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Coaling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 BEDROOM Default 8 Ibs/s .ft. ft' ft 0.3 KITCHEN/LIVING 818/2019 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2617 LPL DISPLAY CARD RECEIVED I y, J6 r AUG 0 4 019 ENERGY PERFORMANCE LEVEL (EPL) DISPLA QARElcounty, Permitting ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply duds R 6.0 2. Single-family or multiple -family 2. Single-family b) Returnducts R' 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 1 13. Cooling system: Capacity 17.6 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 752 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.275 14. Heating system: Capacity 17.0 c) Area 7c. 111.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE ® Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF --0.95 / b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec9/6 B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: l Date: Q (4 1 (C( Address of New Home: 0 DYER ROAD City/FL Zip: PORT ST. LUCIE. FL 8/8/2019 10:02:17 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA ,r TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT ITER5ECENEQ V Project Name: JOHN&LISA WISWELL Builder Name: AUG 0 Street: 0 DYER ROAD Permit Office: ST. LUCIE CO NTY City, State, Zip: PORT ST. LUCIE , FL, Permit Number. ST. Lucie County, Permitting U Owner: JOHN & LISA WISWELL Jurisdiction: w Design Location: FL, Fort Pierce x � COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA -General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit Y the insulation and any gaps in the air barrierair shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exteriorwalls, or insulation that on installation readily conforms to available space shall extend behind pipino and winna. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall an exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover plates and walls or ceilincs. I I d. m eommon, mspecmon or iog wails snap oe in accordance wan the provisions or icc-4uu. 8/8/2019 10:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Pro ect Summa Job: �!- wri�htsoft® Entire House ry Bate: ar• QUICK CALCS, INC. 317 ST. LUCIE LANE, FORTPIERCE, FL34946 Plow 772-466-6799 Email: OUICKCALCS@AOL.COM Project• • For. JOHN & LISAWISWELL 0 DYER ROAD, PORT ST. LUCIE, FL RECEIVED Notes: SCANNED 1 1 B`/ 'Ui; O'� '' 9 — SttucieCoanty -JT, LW910946lnty, ftnt Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr4b Heating Summary Structure 12362 Btuh Duds 1942 Btuh Central vent (0 cfin) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 14304 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Hea75g Cool'g Area(tR) Volume (fl) 6768 6768 Airchangeslhour 0.61 0.32 Equiv. AVF (cfm) 69 36 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflowfactor Static pressure Space thermostat 100 EFF 4.0 kW 13628 Btuh 50 OF 248 din 0.017 cfmBtuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 10570 Btuh Duds 2208 Btuh Central vent (0 cm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Ratelswingg multiplier 0.95 Equipment sensible load 12139 Btuh Latent Cooling Equipment Load Sizing Structure 2308 Btuh Duds 720 Btuh Central vent (0 chi) 0 Btuh (none) Equipment latent load 3028 Btuh Equipment Total Load (Sen+Lat) 15167 Btuh Req. total capacity at 0.70 SHR 1.4 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond CA16NW01800GOA0 Coil FX4DNF025L AHRI ref 9200857 Efficiency 13.0 EER,16 SEER Sensibleccoling 12320 Btuh Latent cooling 5280 Btuh Total cooling 17600 Btuh Actual airflow 587 Clint Airflowfador ��446 dmBtuh Static pressurREVIEWED F®°0.50 in H2O Load sensCibl®f6Vtip,®MPLI� E STo LUCIE COUNTY S®CC Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ wrigM1tsoTt' 2019-Aug-0810:1428 ACCA ..—...—.-, RI9h-SuteDaUriversa1207919.0.07 RSW8101 Pagel ...urefts�WrIghsaBHUAMISWELL, JOHN&LISAny Calc=MIB From Dooffaces: W ffOO Om O A O o fmD O p O m—m N � �ty] !D �O § �ry`a pm Io tO000 Opm000 Nc1 l7 m3 N no p O000m u�m .J � � m N N i U � 0 x �m000np000�m I _'.E 0 0 m N �mOOOmmOpO�N'N p e V !`fp 1{{r�r��NO�'Y I�NNO O m N O mp N pp0 mN O 0000 m^l� O O N� U �y �m (7 pmjn N('pprnWmryA bh OnN nO j`V OOO(�Vp pN m V O C = �O = y C N��O�m �pOONr^ N N .ii O m m N N N N p e NNcq �di�icd�NmNNNo—o i� _� o ogm oom op mm msi, vrni,� �mm�REEEECo�m� W V V0 V P V rmj V m �`�lN o0000000 0000 6 S ap$ � a 1 � � t�r7 �i � � C�C a ed, T E.7 WW9 INB FT �?IULL u 3 o � `o m8 LL o� 0 m m ryti N U I' T n O n000�00NON0 N Q ry t�l a0 � �00 O �O YI t0 OOOtf]n m mm m g Cl N O&O 0 0 0 m 0 0' OS) m NOOm Ip 0 _N 0 0 0 _Nry n W O 8 i 0 o x �� om000�o000 �.� e C i O O E O&fO OOWOO'O�� N V N Q Wn O O O O O O O 00 O Q m O W 00 W rm OOOgV Nm m � m 8 m �v SQq �i000O000Q�o u� 0 �o m N O x = mi ��m0000000 mmW o O � Lll N Cy m E W�mo00000022 0 F9 W Ww PU,S N-cgwcs o NtO IV (7 l�NNmO�O _ SSm g`°Smm(mV �iN� {per Yn Q Q � Q2 P2 M2 M2 C2 � A N Z� 2� e �eovQvmPW o00000000000 o wigs FSC f 44E m m EE g'3�ry�Wpp Ufj2C/j� -cM—H E EE A qq wrightsoft• Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Ptone: 772466-6799 Emil: QUICKCALCS@AOL.COM 1 Room name KrrCHENAMNG 2 3 4 5 ETosed wall Room height Roandmenio Room area 67.0 ft 9.0 ft heaVmol 17.0 x 25.0 It 425.0 fK Ty Conshdion number U-value (Bfuh/ 'F) Or HTM (BhAu1P) Area (" ar penmeter (M Load (Btuh) Area or Perimeter Lead Heat Cool Gros N1P)S Heat Cool Gros NINS Heat Cad 6 11 W Y—G 13A-4ocs 13A4= 4A5-2ov 13A-4ors 4A5-20W 13A-0ov 13AAov 4A5-20v 4A5-2ov 11DO 16X19-0ml 22A-ptl 0.143 0.143 0.470 0.143 0.470 0.470 0.470 0A70 0.470 0.390 OA08 0.989 m se se sw sv nw w rra w nw - 4.00 4.00 13.16 4.00 13.16 13.00 4.16 13.16 13.16 10.92 1.59 27.69 219 219 16.14 219 13.55 219 28.E 28.29 28.29 10.34 1.13 0.00 0 225 0 153 54 220 0 28 0 21 425 425 0 225 0 99 54 170 0 0 0 21 425 67 0 901 0 395 716 703 0 373 0 229 674 1855 0 492 0 216 737 384 0 801 0 217 481 0 1�! L--6 C F 6 C)AED exoJrsim 1314 En%clope loss(gain 5846 4643 12 a) Infiltralion b) Roomy iilafion 1144 0 322 0 13 Interval gains Omtpanls@ 230 2 460 Appliarms(olher 20DO Sublotal(Iines6to13) 6990 7424 14 15 LeseAwlalload Lestansrer Redishibulim Submlal Duct loads 16% 21% 0 0 0 699 0 1098 0 0 0 7424 1551 Total room load Airregdred(dm) 8089 140 8975 412 Calculations approved byACCAto meet all requirements of Manual J 8th Ed �f't- wrighisoR^ 2019-Aug-0810:14:28 Rigt1-Sute®UdvemI201919.0o7 RSU08101 Page 3 ..mer/s\Wni;;Woft WAC\WISWELL, JOHNS, USAxW Cafc=MJB Fror¢Doorfaces W -�+ wrightsoft° Duct System Summary Job: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LANE. FORiPIERCE, FL34946 P1ure: 772-466-6799 Email: OUICKCALCS@AOL.COM Project• • For. JOHN&LISAWISWELL 0 DYER ROAD, PORT ST. LUCIE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest fiction rate Actual airflow Total effective length (fEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 248 cfm E Supply Branch Detail Table Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 587 cfm Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfrn) (cfm) FIR (in) (in) Mat Ln (ft) Ln (ft) Trunk BATH c 821 35 38 0.080 4.0 Ox0 VIFx 12.4 70.0 BEDROOM c 2158 44 99 0.080 7.0 Ox0 VIFx 3.2 70.0 WCHENLMNG C 4488 70 206 0.080 8.0 OXO VIFX 19.0 70.0 KncHENLIVING-A C 4488 70 206 0.080. 8.0 OXO VIFX 5.0 70.0 wlc C 823 29 38 0.080 4.0 Ox0 VIFx 13.4 70.0 Return Branch Detail Table Name Grille Size (in) Htg (Cfm) Clg (Cfm) TEL (it) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 248 587 0 0 0 0 Ox 0 Wx _ wrightsoft' 2019-Aug-0810:1428 ••..-� ...-+�....+ MgICSLite®Urizrml201919.0.07RSU08101 ACCK Page ...umerLs\WrigItsoHHUAQWISWELL, JOHN&USAxW Cale=MJ8 FromOoorface& W