HomeMy WebLinkAboutKSM REPORTHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
DATE TESTED:
PERMIT #:
CONTRACTOR:
JOB LOCATION:
C1 t ENGINES"'V6
1�7iYi AND1FSurlC
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 2922
January 2, 2020
Adams Homes
5301 San Benedetto Place
Lot 1, Waterstone
Fort Pierce, Florida
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone:772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB #: 200023-1c�MH_/jo
ECEnNrED
f JAN 0 71010
ng Department
SCAMM t. Lurie County
St. LucieCounti
ITEM TESTED: Compacted Foundation Fill
TEST LOCATION DEPTH PEN DRY MAX. DRY PERCENT
OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION
1. S.W.
2. N.W.
3. Center
4. S.E.
5. N.E.
Soil Description:
Brown Sand with Shell
Fragments
In Place Moisture:
6.3%
Optimum Moisture:
11.0%
Max. Dry Density: P.C.F.
114.9
0" -12" 50
" 50
50
@ Test Locations The
Density & Penetrometer
Readings Indicate the
Degree of Compaction Meets
Minimum Required
for Staked Founda
50
" 50
111.6 114.9
114.5 "
113.7 "
112.9 "
110.4 "
W 116.0 f
E
I
G 115.0 1—
H
T
114.0 �—
P
C 113.0T-—I—
F I I
• I I I
112.0 D ` ..—.1—..—.�.—..—r —
R i I I I
Y t I I I
111.0 I—..—. _.._...—..—i —
8 9 10 11
rTgst, eel 9
Red fly tie: D BUJ
JAN 7 2020
1 " S
Dahlke P.Ee
r ggTATE O o
of kngmeer("
Fi'�`�1�\ 1/3/2020
97.1 %
99.7%
99.0%
98.3%
96.1%
i
i
I
I
I
I
I
I
I
I
I
I
12
13
14
Moisture - % of Dry Weight
Disclaimer: Contractor is responsible to maintain
the tested area in the condition that KSM
completed the indicated passed compaction test.
KSM is not responsible if the tested area has been
altered from the approved inspected condition.
"jokinsbn,C�adamshomes.com; ceo2459@gma'il.com
III Jill\ Proudly Serving Florida since 1990