HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Vkginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Faz:(772)462-6443 PROPERTY INFORMATION Address: 6904 Ocala Ave City IState /-Zip: Fort Pierce, FI 34947 Parcel#: 1301-612-0254-000/1 Zoning: RS-4 APPLICATION INFORMATION Permit Number: 1805-0392 REVIEW COMMENTS ,XANWED St. LUC� C®Uw Owner(s): Claudia C Cuba / Miguel A Guerra-Ressy Jurisdiction: SAINT LUCIE COUNTY Lot#: 6 Block: 129 Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Stories: Automatic Sprinkler System? No Contractor Name: Roderick J Waller Fax Number: 772-907-0420 Business Name: Sunrise City Community Housing Dev Org Inc Business Addr: 3550 Okeechobee Road Email: Rodwallerl@Gmail.Com City / State I Zip: Fort Pierce, FI 34947 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released PLANS EXAMINER REVIEW INCOMPLETE Joseph Fersch Comment: THE PERMIT THAT HAS BEEN APPLIED FOR IS FOR RENOVATIONS. THE STRUCTURE WAS PERMITTED UNDER THE 1989 FLORIDA SOUTHERN BUILDING CODE PERMIT #48774 AND CONSTRUCTED AS A 7/11/2018 SHEDIWORKSHOP. IN ORDER TO MAKE THE CHANGE FROM A SHEWWORKSHOP THE PERMIT NEEDS TO BE CHANGED FROM A RENOVATION TO A CHANGE OF OCCUPANCY AND WILL BE REQUIRED TO MEET THE 2017 FLORIDA BUILDING CODE AND CURRENT ST. LUCIE COUNTY ORDINANCES & REQUIREMENTS. Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 7/11/2018 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. Comment: THE CHANGE OF OCCUPANCY TYPE SHALL SHOW COMPLIANCE WITH 2O17 FLORIDA BUILDING CODE 7/11I2018 EXISTING AND REQUIRE GNED t THATT LIMIT STHEOM A FLORIDA INCLUDELL PROFESSIONAL BUTNOT D TTOLED FOLLOWING ITEMS. 7 1. 1 7/11/2018 Comment: APPROVALS FROM THE HEALTH DEPARTMENT WILL BE REQUIRED. Comment: PROVIDE DETAILED 2017 FLORIDA BUILDING CODE ANALYSIS FROM A FLORIDA DESIGN PROFESSIONAL THAT INCLUDES BUT NOT LIMITED TO AL APPLICABLE FLOORIDA BUILDING CODES, 7/11/2018 NFPA CODES NEC CODES, OCCUPANT LOAD INCLUDING EACH OCCUPANCY TYPE OF THE BUILDING, AND PROVIDE COMMON PATH OF EGRESS TRAVEL ALLOWED AND PROVIDE, CORRIDOR WIDTH REQUIRED AND CORRIDOR WIDTH PROVIDE, EXIT EIDTH REQUIRED AND EXIT WIDTH PROVIDED, AND PLUMBING FIXTURE COUNT REQUIRED AND PROVIDED. Ill I Comment: THE WIND LOAD OF THE BUILDING NEEDS TO BE ADDRESSED WHEN THE CHANGE OF OCCUPANCY PUTS 7/11/2018 THE STRUCTURE INTO A HIGHER RISK CATEGORY PER CHAPTER 16 OF THE 2017 FLORIDA BUILDING CODE. L "Io jf 3 7/11/2018 Comment: THE LIVE LOAD OF WOOD FLOORS AND STAIRS MUST COMPLY WITH THE REVISED USE OF THE BUILDING PER CHAPTER 16 OF THE 2017 FLORIDA BUILDING CODE. L '161- ,— Y 7/1112018 Comment: THE NEW OCCUPANCY MUST COMPLY WITH CHAPTER 9 OF THE 2017 FLORIDA BUILDING CODE FOR FIRE SAFETY. 7/11/2018 Comment: WIND BORNE DEBRIS PROTECTION WILL BE REQUIRED FOR GLASEO OPENINGS PER THE 2017 BUILDING CODE. G�.4x3 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Faz:(772)4626443 REVIEW COMMENTS Comment: THE NEW OCCIUPANCY MUST COMPLY WITH CHAPTER 10 OF THE FLORIDA BUILDING CODE. WHICH 7/11/2018 INCLUDES BUTNOT LIMITED TO DOOR, CORRIDORS, STAIRS GUARDRAILS/FALL PROTECTION, CEILING HEIGHTS 7/11/2018 Comment: THE NEW OCCUPANCY WILL REQUIRE COMPLIANCE WITH THE .2017.FLORIDA .BUILDING CODE ACCESSIBILITY. 7/11/2018 Comment: THE NEW OCCUPANCY WILL BE REQUIRED COMPLY WITH THE 2017 FLORIDA BUILDING CODE FOR MECHANICAL. 7/11/2018 Comment: THE NEW OCCUPANCY WILL BE REQUIRED TO COMPLY WITH THE 2014 NATIONAL ELECTRICAL CODE. ZONING REVIEW INCOMPLETE Lydia Galbraith 7/9/2018 7/1012018 Comment: PLEASE PROVIDE A COPY OF THE HEALTH DEPARTMENT PERMIT FOR SEPTIC AND FOR THE WELL. 7/102018 Comment: PLEASE PROVIDE TWO FLOOR PLANS AND TWO UPDATED SURVEYS STAMPED FOR APPROVAL BY THE HEALTH DEPARTMENT. Comment: PLEASE PROVIDE (2) SIGNED AND SEALED UPDATED SURVEYS INDICATING: - LOCATION OF THE STRUCTURE - FINISHED FLOOR ELEVATION - ELEVATION OF THE CENTER LINE OF THE ROAD 7/10/2018 -SETBACKS - DRIVEWAY AND SURFACE USED OR PROPOSED - 2 PAVED PARKING SPACES OF EACH 10'X18' ARE REQUIRED BY SLC LAND DEVELOPMENT CODE. THE PARKING SPACES MAY BE LOCATED ON A PAVED DRIVEWAY - LOCATION OF THE DRAIN FIELD, SEPTIC TANK AND WELL. 7/10/2018 Comment: A DRIVEWAY PERMIT IS REQUIRED TO CONNECT WITH OCALA AVE. AN APPLICATION FOR THE ROAD & BRIDGE DEPARTMENT IS REQUIRED. THE FEE OF $ 150.00 WILL BE ADDED TO THIS PERMIT. Comment: DUE TO CONVERSION OF STORAGE BUILDING TO A SFR IMPACT FEES WILL BE APPLICABLE. THE TOTAL 7/10/2018 REQUIRED IMPACT FEES OF $ 14.463.00 WILL BE ADDED TO THIS PERMIT AND ARE DUE AT TIME OF PICK UP. JG• �arritPi �Po[�t� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:V72)462.2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 6904 Ocala Ave .City /-State / Zip: Fort Pierce, FI 34947 Parcel#: 1301-612-0254-000/1 Zoning: RS-4 APPLICATION INFORMATION Permit Number: 1802-0357 REVIEW COMMENTS °p�c�fNNEg Jf. CUg6C6a* Page 1 Owner(s): Claudia C Cuba/-MiguelAGuerra-Ressy Jurisdiction: SAINT LUCIE COUNTY Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State I Zip: REVIEWS AND COMMENTS Lot#: 6 Block: 129 Stories: Automatic Sprinkler System? No Fax Number: Email: Review Type Status Reviewed By Date Started Date Completed Date Released PLANS EXAMINER REVIEW INCOMPLETE Joseph Fersch 5/1612018 Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 5/16/2018 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. Comment: • PLEASE FURNISH A INTERIOR WALL DETAIL SHOWING STUD SPACING, STUD SIZE, AND WALL FINISH IN 5/16/2018 ACCORDANCE WITH 602.2 OF THE 2017 FLORIDA BUILDING CODE Comment: • PLEASE FURNISH DETAIL FOR INTERIOR GUARD RAILS BEING IN ACCORDANCE WITH SECTION 3I2OF 5/1612018 THE 2010 FLORIDA RESIDENTIAL CODE Comment: • PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING 5/16/2018 FINISHES IN ACCORDANCE WITH SECTION 302.9 OF THE 2017 FLORIDA RESIDENTIAL CODE Comment: • PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS 5/16/2018 REQUIRED IN SECTION 302.10 OF THE 2017 FLORIDA RESIDENTIAL CODE 5/16/2018 Comment: PLEASE SHOW THE WATER SUPPLY AND DISTRIBUTION SYSTEM-DESIGN(CHAPTER 29) Comment: PLEASE SHOW ELECTRICAL DETAIL IN ACCORDANCE WITH SECTION E3401.4 FLORIDA RESIDENTIAL 5/16/2018 CODE SIXTH ADDITION. Comment: PLEASE SHOW MECHANICAL DETAIL IN ACCORDANCE WITH M1202.1 FLORIDA RESIDENTIAL CODE SIXTH 5/16/2018 ADDITION. i �lT�G 46"ftzy Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS 1 PROPERTY INFORMATION Address: 6904 Ocala Ave Owner(s): Claudia C Cuba I Miguel A Guerra-Ressy City I State / Zip: Fort Pierce, FI 34947 Parcel #: 1301-612-0254-000/1 Jurisdiction: SAINT LUCIE COUNTY Zoning: RS-4 Lot#: 6 Block: 129 APPLICATION INFORMATION Permit Number: 1805-0392 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Roderick J Waller Fax Number: 772-907-0420 Business Name: Sunrise City Community Housing Dev Org Inc Email: Rodwallerl@Gmail.Com Business Addr: 3550 Okeechobee Road City / State / Zip: Fort Pierce, FI 34947 REVIEWS AND COMMENTS Review Tvoe Status Reviewed By Date Started Date Completed Date Released PLANS EXAMINER REVIEW INCOMPLETE Joseph Fersch Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED 5/16QO18 DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. Comment: PLEASE FURNISH A INTERIOR WALL DETAIL SHOWING STUD SPACING, STUD SIZE, AND WALL FINISH IN 5116/2018 ACCORDANCE WITH 602.2 OF THE 2017 FLORIDA BUILDING CODE Comment: PLEASE FURNISH DETAIL FOR INTERIOR GUARD RAILS BEING IN ACCORDANCE WITH SECTION 312 OF THE 511612018 2010 FLORIDA RESIDENTIAL CODE Comment: PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES 5/16/2018 IN ACCORDANCE WITH SECTION 302.9 OF THE 2017 FLORIDA RESIDENTIAL CODE Comment: PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED 5/16/2018 IN SECTION 302.10 OF THE 2017 FLORIDA RESIDENTIAL CODE 5/16/2018 Comment: PLEASE SHOW THE WATER SUPPLY AND DISTRIBUTION SYSTEM-DESIGN(CHAPTER 29) Comment: PLEASE SHOW ELECTRICAL DETAIL IN ACCORDANCE WITH SECTION E3401.4 FLORIDA RESIDENTIAL 5/16/2018 CODE SIXTH ADDITION Comment: PLEASE SHOW MECHANICAL DETAIL IN ACCORDANCE WITH M1202.1 FLORIDA RESIDENTIAL CODE SIXTH 5/16/2018 ADDITION. Planning a Development Services Building & Code Regulation DlWaion 2300 Virginia Avenue FortPleme,FL 34982 Phone:V72)462.2172 Fax;( M)162.6443 REVIEW COMMENTS SCANNED BY St LucieCount/ 1 Address: 6904 Ocala Ave Owner(s): Claudia C Cuba /Miguel A Guerra-Ressy City State /-Zip: Fort Pierce, FI 34947 Parcel #: 1301-612-0254-000/1 Jurisdiction: SAINT LUCIE COUNTY Zoning: RS4 Lot#: 6 Block: 129 APPLICATION INFORMATION Permit Number: 1805-0392 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Roderick J Waller Fax Number: 772-907-0420 Business Name: Sunrise City Community Housing Dev Org Inc Business Addr: 3550 Okeechobee Road Email: Rodwallerl@Gmail.Com City / State / Zip: Fort Pierce, FI 34947 REVIEWS AND COMMENTS Review Type PLANS EXAMINER REVIEW Comment: 5/16/2018 5/16/2018 Comment: 5/16/2018 Comment: 5/162018 Comment: 5/162018 Comment: 5/16/2018 Comment: 5/16/2018 Comment: 5/162018 Comment: Status Reviewed By Date Started Date Completed Date Released INCOMPLETE Joseph Fersch PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. PLEASE FURNISH A INTERIOR WALL DETAIL SHOWING STUD SPACING, STUD SIZE, AND WALL FINISH IN ACCORDANCE WITH 602.2 OF THE 2017 FLORIDA BUILDING CODE PLEASE FURNISH DETAIL FOR INTERIOR GUARD RAILS BEING IN ACCORDANCE WITH SECTION 312 OF THE 2010 FLORIDA RESIDENTIAL CODE PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES IN ACCORDANCE WITH SECTION 302.9 OF THE 2017 FLORIDA RESIDENTIAL CODE PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED IN SECTION 302.10 OF THE 2017 FLORIDA RESIDENTIAL CODE PLEASE SHOW THE WATER SUPPLY AND DISTRIBUTION SYSTEM-DESIGN(CHAPTER 29) PLEASE SHOW ELECTRICAL DETAIL IN ACCORDANCE WITH SECTION E3401.4 FLORIDA RESIDENTIAL CODE SIXTH ADDITION PLEASE SHOW MECHANICAL DETAIL IN ACCORDANCE WITH M1202.1 FLORIDA RESIDENTIAL CODE SIXTH ADDITION. S.z��OrG!!i !/Ov+aw.Z Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 REVIEW COMMENTS SCANNED BY St Luce COOnty 2/19/2019 Comment: 14. PLEASE PROVIDE A COMPLETE ELECTRICAL DETAIL PURSUANT TO OF THE FLORIDA BUILDING CODE - RESIDENTIAL 6TH EDITION 2017 AND THE NEC 2014 211912019 Comment: 15. PLEASE PROVIDE THE REQUIRED ENERGY CALCULATION PURSUANT TO CHAPTER 4 OF THE FLORIDA BUILDING CODE -ENERGY CONSERVATION ZONING REVIEW INCOMPLETE Lydia Galbraith 7/9/2018 7/10/2018 Comment: PLEASE PROVIDE A COPY OF THE HEALTH DEPARTMENT PERMIT FOR SEPTIC AND FOR THE WELL. " TWO UPDATED SURVEYS STAMPED FOR APPROVAL BY THE Vol 7/10/2018 Comment: PLEASE PROVIDE TWO FLOOR PLANS AND HEALTH DEPARTMENT. Comment: PLEASE PROVIDE (2) SIGNED AND SEALED UPDATED SURVEYS INDICATING: - LOCATION OF THE STRUCTURE ✓ - FINISHED FLOOR ELEVATION ✓ ✓ - ELEVATION OF THE CENTER LINE OF THE ROAD 7/10/2018 -SETBACKS - DRIVEWAY AND SURFACE USED OR PROPOSED - 2 PAVED PARKING SPACES OF EACH 1 O'X18' ARE REQUIRED BY SLC LAND DEVELOPMENT CODE. THE PARKING SPACES MAY BE LOCATED ON A PAVED DRIVEWAY LO ATION OF THE DRAIN FIELD, SEPTIC TANK AND WELL. Comment: A RIVEWAY PERMIT IS REQUIRED TO CONNECT WITH OCALA AVE. AN APPLICATION FOR THE ROAD & 7/10/2018 IDGE DEPARTMENT IS REQUIRED. THE FEE OF $ 150.00 WILL BE ADDED TO THIS PERMIT. Comment: DUE TO CONVERSION OF STORAGE BUILDING TO A SFR IMPACT FEES WILL BE APPLICABLE. THE TOTAL 7/10/2018 REQUIRED IMPACT FEES OF $ 14.463.00 WILL BE ADDED TO THIS PERMIT AND ARE DUE AT TIME OF PICK UP. 1805-0392 1. Please provide the design criteria pursuant to section R301 of the florida building code -residential 6th edition 2017 2. Please provide ceiling height detail pursuant to section R304.3 of the florida building code -residential 61h edition 2017 3. Please provide ceiling height detail pursuant to section R305.1 of the florida building code -residential 61h edition 2017 4. Please provide human impact loads detail pursuant to section-R308.3 of the floridabuildingcode- residential 611' edition 2017 5. Please provide ceiling height detail pursuant to section R310.2.1of the florida building code -residential 61h edition 2017 6. Please provide detail Floors and landings at exterior doors pursuant to SECTION R311.3 & R311.3.1 of the florida building code -residential 6t1 edition 2017 7. Please provide complete stair detail pursuant to section R311.7 - R311.7.8.3 of the florida building code - residential 61h edition 2017 8. Please provide complete stair detail smoke alarms pursuant to section R314 of the florida building code - residential 6'h edition 2017 9. Please provide detail for accessibility pursuant to section R320.1.1 of the florida building code -residential 61h edition 2017 10. Please provide floor framing design drawings pursuant to section R502.2 of the florida building code - residential 6th edition 2017 11. Please provide truss design drawings pursuant to section R802 of the florida building code -residential 6'h edition 2017 12. Please provide roof venting detail pursuant to section R806.1- R806.3 of the florida building code - residential Wh edition 2017 13. Please provide a complete mechanical detail pursuant to of the florida building code -residential 6'h edition 2017 14. Please provide a complete electrical detail pursuant to of the florida building code -residential 6th edition 2017 and the nec 2014 15. Please provide the required energy calculation pursuant to chapter 4 of the florida building code -energy conservation