HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405.2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: JONATHAN 8 SHARI GREENE
Builder Name: BDR
SCANNED
1815 NW BUTTONWOOD CIRCLE
Permit Once: ST. LUCIE COUNTY
State, Zip: PALM CITY, FL,
Permit Number.
BYCity,
Owner. JONATHAN & SHARI GREENE
Jurisdiction: ST. LUCIE COUNTY
;;yS rya
St Lucie Countv
Design Location: FL, Fort Pierce
County: St Lucie (Florida Climate Zone 2 )
1 Newconstruc0onorexisting - - - - Addition- - - - -
-9--Wall-Types(1872.0 sqR) _
_ --Insulation Area
2. Single family or multiple family Single-family
- _
a. Concrete Block- Ext Insul, Exterior R=4.1 1692.00 ft'
• 3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 180.00 ft'
c. N/A
4. Number of BedmomgBedrms In Addition) 3(0)
d. N/A
R=
S. Is this a worst case? No
10. Ceiling Types (2202.0 sqft.)
ft
Insulation Area
6. Conditioned floor area above (W) 2202
a. Under Attic (Vented)
R=30.0 2202.00 ft'
grade
b. WA
R= ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= ft'
7. Windows(402.5 sgft11.
.) Description Area
Ducts
a. Sup: Attic, Rat Attic, AH: Attic
R ft'
6 225
a. U-Factor: Sgi, U=0.35 200.00 ft'
SHGC: SHGC=0.20
b. U-Factor: Sgl, U=029 113.82 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.23
a. Central Unit
46.5 SEER:16.00
c. U-Factor. Sgi, U=0.34 45.00 ft'
SHGC: SHGC=0.17
d. U-Factor. other (see details) 43.67 ft'
13. Heating systems
kBtu/hr Efficiency
SHGC: other (see details)
a. Electric Strip Heat
34.0 COP:1.00
Area Weighted Average Overhang Depth: 6.969 R.
Area Weighted Average SHGC: 0.205
14. Hot water systems- Replacement equipment
8. Floor Types (2202.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2202.00 ft'
b. Conservation features
EF: 0.950
b. NIA R= �
None
c. WA R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.183 Total Proposed Modified Loads: 62.37
PASS
Total Baseline Loads: 65.83
I hereby certify that the plans and specifications covered by
Review of the plans and
STglF
this calculation are in compliance with the Florida Energy
Code,
specifications covered by this
pf-VUE
4V a p
PREPARED BY:-
calculation indicates compliance
with the Florida Energy Code.
F glu,Y •,. ;+a";;',3°r p
Before construction is completed
Z:
DATE: 9 77
this building will be inspected for
compliancewith Section 553.908
I hereby certify that this building, as design .d, is in compliance
with the Florida
Florida Statutes.
r,
Energy Code.
WE
OWNER/ENT
BUILDING OFFICIAL:
DATE: - t
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9/17/2019 10:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
JONATHAN & SHARI GREE
User
JONATHAN & SHARI GREE
1
BDR
ST. LUCIE COUNTY
ST. LUCIE COUNTY
Single-family
Addition
Bedrooms: 3
Conditioned Area: 2202
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBcok:
Street: 1815 NW BUTTONWO
County. St. Lucie
City, State, Zip: PALM CITY,
FL,
CLIMATE
/
V Design Location TMY Site
Design Temp
97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH MUNI 39 90
70 75 299 62 LOW
BLOCKS
Number
Name Area
Volume
1
Blockl 2202
19818
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main 2202
19818 Yes 0
3 1 Yes Yes Yes
FLOORS
#
Floor Type Space
Perimeter R Value
Area Tile Wood Carpet
1 Slab-On-Grsde Edge Insulatio Main 245 ft 0
2202 W _ 0 0 1
ROOF
_ /
V #
Type Materials
Roof Gable Roof
Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Bart Absor. Tested Tested Insul. (deg)
1
Gable or shed Barrel the
2385 W 458 ft' Medium
N 0.6 No 0.9 No 0 22.6
ATTIC
/
V #
Type Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic Vented 150 2202ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2202 ft' 0.11 Wood
9/17/2019 10:35 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY (_I4I=rKI ICT 12PPAPT
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar
Below
_ 1 E
Exterior Concrete Block- Ext Insul
Main
4.0999 54 9
486.0 IF
0
0 0.600000
0
2 S
Exterior Concrete Block - Ext Insul
Main
4.0999 64 9
576.0 ft'
0
0 0.600000
0
-3 W
Exterior Concrete Block- Ext Insul
Main
4.0999 32 9
288.0 ft'
0
0 0.600000
0
4 N
Exterior Concrete Block- Ed Insul
Main
4.0999 38 9
342.0 ft'
0
0 0,600000
0
_5 W
Garage Frame -Wood
Main
11 20 9
180.0 ft'
0
0.23 0.600000
0
WINDOWS
Orientation shown Is the entered Pro osed orieritaflon.- -
Orientation
- -
- - - ----
/
Wall
Overhang
V #
Omt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade Screening
1
E 1 Vinyl Low-E Single
Yes
0.29 0.23 N
40.5 W 2 S 0 in
1 It 41n
None
None
2
E 1 Vinyl Low-E Single
Yes
0.35 0.2 N
152.0 it' 12 It 0 in
1 ft 4 in
None
None
_ 3
E 1 Vinyl Low-E Single
Yes
0.34 0.17 N
30.0 W 2 ft 0 in
1 It 4 in
None
None
4
S 2 Vinyl Low-E Single
Yes
0.35 0.2 N
48.0 ft' 12 ft 0 in
1 ft 4 in
None
None
_ 5
S 2 Vinyl Low-E Single
Yes
0.34 0.18 N
13.7 IF 2 ft 0 in
1I ft 4 in
None
None
6
S 2 Vinyl Low-E Single
Yes
0.34 0.17 N
15.0 W 2 ft 0 in
1 ft 4 in
None
None
7
S 2 Vinyl Low-E Single
Yes
0.29 0.23 N
5.3 ft' 2 ft 0 in
1 It 4 in
None
None
8
W 3 Vinyl Low-E Single
Yes
0.29 0.23 N
48.0 ft' 2 ft 0 In
1 ft 4 In
None
None
9
W 3 Vinyl Low-E Single
Yes
0.31 0.18 N
10.0 ft' 2 ft 0 In
1 ft 4 In
None
None
' 10
N 4 Vinyl Low-E Single
Yes
0.29 0.23 N
20.0 ft' 2 It 0 in
1 ft 4 in
None
None
11
N 4 Vinyl Low-E Single
Yes
0.59 0.23 N
20.0 ft' 2 ft 0 in
1 It 4 In
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
528 ft' 528 ft'
24 ft
8 It
t t
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004
2312.1 126.93 238.71 .1454
7
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/Fxistingloo None
COPA
34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1
.Central Unit/Existing/confirms None
SEER: 16 46.5 k8tu/hr 1395 cfm 0.8
1
sys#1
9/171201910:35 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
I
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
#
System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.95
50 gal
60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart #
Company Name
System
Model # Collector Model
# Area
Volume
FEF
None
None
fta
—
---
-- -DUCTS—
—
— —
— —
—
—
—
—
Supply—
—Return
Air
CFM 25
CFM25
HVAC#
V #
Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Coal
1
Attic
6 225 ft'
Attic
65 it'
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:ar
Cooling Jan
Venting Jan
Feb
Feb
M
Mar
Apr
Apr
May
�0
Jun [ ] Jul
D(�
1 Aug
D�
)) Sep
[ j
L 1
Dec
rDO, Decec
[ JX
May
Jun [)Jul
E 1 Aug
[ 1 Sep
Ixl
Oct
X Nov
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9
10
11
12
Cooling (WO)
AM
78
78 78
78
78 78
78
78
80
80
80
80
PM
80
80 78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78
78 78
78
78
78
78
78
78
PM
78
78 78
78
78 78
78
78
78
78
78
78
Heating(WD)
AM
66
66 66
66
66 68
68
68
68
68
68
68
PM
68
68 68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66
66 68
68
68
68
68
68
68
PM
68
68 68
68
68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default B lbs/s .ft.
0 ft.
0 ft
0.3
Main
9117/201910:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. Addition 12. Ducts, location & insulation level
a) Supply ducts R 6.0
--2-Single-family or multiple=family -2-Single-family 15TReturn ducts - --R - 6.0 -
c) AHU location Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms
4.
3
5. Is this a worst case? (yes/no)
5.
No
6. Conditioned floor area (sq. ft.)
6.
2202
7. Windows, type and area
a) U-factor.(weighted average)
7a.
0.343
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.205
c) Area
7c.
402.5
8. Skylights
a) U-factor:(weighted average)
8a.
NA
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
T Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
c) Concrete, raised (R-value)
90.
10. Wall type and insulation:
A. Exterior.
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee wallsiskylight walls
d) Radiant barrier installed
10A1.
10A2. 4.1
13. Cooling system:
Capacity 46.5
a) Split system
SEER
b) Single package
SEER
c) Ground/water source
SEERICOP
d) Room unit/PTAC
EER
e) Other
16.0
14. Heating system: Capacity 34.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
10131. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:
Address of New Home: 1815 NW BUTTONWOOD CIRCLE City/FL Zip: PALM CITY, FL
9/17/201910:35:34 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
no Dom.
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Wave)
TABLE 402.4.1.1 SEP 17 201•9
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Permlttin De a�
Project Name: JONATHAN & SHARI GREENS Builder Name: BDR St. Lucie r
Street 1815 NW BUTTONWOOD CIRCLE Permit Office: ST. LUCIE COUNTY
City, State, Zip: PALM CITY, FL, Permit Number:
Y
Owner. JONATHAN & SHARI GREENS Jurisdiction: ST. LUCIE COUNTY
LLI
Design Location: FL, Fort Pierce
O
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A -continuous air barrier shall be installed in the building envelope—'
Air -permeable insulation shall
requirements
q
The exterior thermal envelope contains a continuous airbarrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceilin soffit
Y aped !1/
the insulation and any gaps in the air bander shall be sealed.
shall be aligned with the air bonier,
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed In substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be Insulated.
Floors
The air barrier shall be Installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfioor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be In contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spar
3s.
Recessed lighting
Recessed light factures Installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
/ sow rs and to s shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
on exterior wall
tubs shall separate them from the showers and tubs,
a CiE
Electricallphone box or
The air barrier shall be installed behind electrical or communication
1 'p'�/
exterior walls
boxes or airsealed boxes shall be installed.
CIE COUNTY
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
BOCC
be sealed to the sub -floor or drywall.
ID
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire %prinkler cover plates and walls or ce-61ina-g.
N-11 M 0""Chav
a. in aaamon, inspecrion or log Walls snail oe In aGooroance wan me provisions of ICC-400. jr 1 IV it `V v u -
9/17/2019 10:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1