Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405.2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JONATHAN 8 SHARI GREENE Builder Name: BDR SCANNED 1815 NW BUTTONWOOD CIRCLE Permit Once: ST. LUCIE COUNTY State, Zip: PALM CITY, FL, Permit Number. BYCity, Owner. JONATHAN & SHARI GREENE Jurisdiction: ST. LUCIE COUNTY ;;yS rya St Lucie Countv Design Location: FL, Fort Pierce County: St Lucie (Florida Climate Zone 2 ) 1 Newconstruc0onorexisting - - - - Addition- - - - - -9--Wall-Types(1872.0 sqR) _ _ --Insulation Area 2. Single family or multiple family Single-family - _ a. Concrete Block- Ext Insul, Exterior R=4.1 1692.00 ft' • 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 180.00 ft' c. N/A 4. Number of BedmomgBedrms In Addition) 3(0) d. N/A R= S. Is this a worst case? No 10. Ceiling Types (2202.0 sqft.) ft Insulation Area 6. Conditioned floor area above (W) 2202 a. Under Attic (Vented) R=30.0 2202.00 ft' grade b. WA R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 7. Windows(402.5 sgft11. .) Description Area Ducts a. Sup: Attic, Rat Attic, AH: Attic R ft' 6 225 a. U-Factor: Sgi, U=0.35 200.00 ft' SHGC: SHGC=0.20 b. U-Factor: Sgl, U=029 113.82 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 46.5 SEER:16.00 c. U-Factor. Sgi, U=0.34 45.00 ft' SHGC: SHGC=0.17 d. U-Factor. other (see details) 43.67 ft' 13. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 6.969 R. Area Weighted Average SHGC: 0.205 14. Hot water systems- Replacement equipment 8. Floor Types (2202.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2202.00 ft' b. Conservation features EF: 0.950 b. NIA R= � None c. WA R= ft' 15. Credits Pstat Glass/Floor Area: 0.183 Total Proposed Modified Loads: 62.37 PASS Total Baseline Loads: 65.83 I hereby certify that the plans and specifications covered by Review of the plans and STglF this calculation are in compliance with the Florida Energy Code, specifications covered by this pf-VUE 4V a p PREPARED BY:- calculation indicates compliance with the Florida Energy Code. F glu,Y •,. ;+a";;',3°r p Before construction is completed Z: DATE: 9 77 this building will be inspected for compliancewith Section 553.908 I hereby certify that this building, as design .d, is in compliance with the Florida Florida Statutes. r, Energy Code. WE OWNER/ENT BUILDING OFFICIAL: DATE: - t DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 9/17/2019 10:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: JONATHAN & SHARI GREE User JONATHAN & SHARI GREE 1 BDR ST. LUCIE COUNTY ST. LUCIE COUNTY Single-family Addition Bedrooms: 3 Conditioned Area: 2202 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBcok: Street: 1815 NW BUTTONWO County. St. Lucie City, State, Zip: PALM CITY, FL, CLIMATE / V Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Blockl 2202 19818 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2202 19818 Yes 0 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R Value Area Tile Wood Carpet 1 Slab-On-Grsde Edge Insulatio Main 245 ft 0 2202 W _ 0 0 1 ROOF _ / V # Type Materials Roof Gable Roof Area Area Color Red Solar SA Emitt Emitt Deck Pitch Bart Absor. Tested Tested Insul. (deg) 1 Gable or shed Barrel the 2385 W 458 ft' Medium N 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2202ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2202 ft' 0.11 Wood 9/17/2019 10:35 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY (_I4I=rKI ICT 12PPAPT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 E Exterior Concrete Block- Ext Insul Main 4.0999 54 9 486.0 IF 0 0 0.600000 0 2 S Exterior Concrete Block - Ext Insul Main 4.0999 64 9 576.0 ft' 0 0 0.600000 0 -3 W Exterior Concrete Block- Ext Insul Main 4.0999 32 9 288.0 ft' 0 0 0.600000 0 4 N Exterior Concrete Block- Ed Insul Main 4.0999 38 9 342.0 ft' 0 0 0,600000 0 _5 W Garage Frame -Wood Main 11 20 9 180.0 ft' 0 0.23 0.600000 0 WINDOWS Orientation shown Is the entered Pro osed orieritaflon.- - Orientation - - - - - ---- / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Single Yes 0.29 0.23 N 40.5 W 2 S 0 in 1 It 41n None None 2 E 1 Vinyl Low-E Single Yes 0.35 0.2 N 152.0 it' 12 It 0 in 1 ft 4 in None None _ 3 E 1 Vinyl Low-E Single Yes 0.34 0.17 N 30.0 W 2 ft 0 in 1 It 4 in None None 4 S 2 Vinyl Low-E Single Yes 0.35 0.2 N 48.0 ft' 12 ft 0 in 1 ft 4 in None None _ 5 S 2 Vinyl Low-E Single Yes 0.34 0.18 N 13.7 IF 2 ft 0 in 1I ft 4 in None None 6 S 2 Vinyl Low-E Single Yes 0.34 0.17 N 15.0 W 2 ft 0 in 1 ft 4 in None None 7 S 2 Vinyl Low-E Single Yes 0.29 0.23 N 5.3 ft' 2 ft 0 in 1 It 4 in None None 8 W 3 Vinyl Low-E Single Yes 0.29 0.23 N 48.0 ft' 2 ft 0 In 1 ft 4 In None None 9 W 3 Vinyl Low-E Single Yes 0.31 0.18 N 10.0 ft' 2 ft 0 In 1 ft 4 In None None ' 10 N 4 Vinyl Low-E Single Yes 0.29 0.23 N 20.0 ft' 2 It 0 in 1 ft 4 in None None 11 N 4 Vinyl Low-E Single Yes 0.59 0.23 N 20.0 ft' 2 ft 0 in 1 It 4 In None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 528 ft' 528 ft' 24 ft 8 It t t INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2312.1 126.93 238.71 .1454 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Fxistingloo None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 .Central Unit/Existing/confirms None SEER: 16 46.5 k8tu/hr 1395 cfm 0.8 1 sys#1 9/171201910:35 AM EnergyGauge® USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None fta — --- -- -DUCTS— — — — — — — — — — Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Coal 1 Attic 6 225 ft' Attic 65 it' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans:ar Cooling Jan Venting Jan Feb Feb M Mar Apr Apr May �0 Jun [ ] Jul D(� 1 Aug D� )) Sep [ j L 1 Dec rDO, Decec [ JX May Jun [)Jul E 1 Aug [ 1 Sep Ixl Oct X Nov [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WO) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default B lbs/s .ft. 0 ft. 0 ft 0.3 Main 9117/201910:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 --2-Single-family or multiple=family -2-Single-family 15TReturn ducts - --R - 6.0 - c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 2202 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.343 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.205 c) Area 7c. 402.5 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA T Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 90. 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee wallsiskylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 13. Cooling system: Capacity 46.5 a) Split system SEER b) Single package SEER c) Ground/water source SEERICOP d) Room unit/PTAC EER e) Other 16.0 14. Heating system: Capacity 34.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10131. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Address of New Home: 1815 NW BUTTONWOOD CIRCLE City/FL Zip: PALM CITY, FL 9/17/201910:35:34 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 no Dom. 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Wave) TABLE 402.4.1.1 SEP 17 201•9 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Permlttin De a� Project Name: JONATHAN & SHARI GREENS Builder Name: BDR St. Lucie r Street 1815 NW BUTTONWOOD CIRCLE Permit Office: ST. LUCIE COUNTY City, State, Zip: PALM CITY, FL, Permit Number: Y Owner. JONATHAN & SHARI GREENS Jurisdiction: ST. LUCIE COUNTY LLI Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A -continuous air barrier shall be installed in the building envelope—' Air -permeable insulation shall requirements q The exterior thermal envelope contains a continuous airbarrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceilin soffit Y aped !1/ the insulation and any gaps in the air bander shall be sealed. shall be aligned with the air bonier, Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R3 Knee walls shall be sealed. per Inch minimum. Exterior thermal envelope insulation for framed walls shall be installed In substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be Insulated. Floors The air barrier shall be Installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfioor decking, or floor framing cavity insulation and cantilevered shall be permitted to be In contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spar 3s. Recessed lighting Recessed light factures Installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall / sow rs and to s shall Shower/tub The air barrier installed at exterior walls adjacent to showers and on exterior wall tubs shall separate them from the showers and tubs, a CiE Electricallphone box or The air barrier shall be installed behind electrical or communication 1 'p'�/ exterior walls boxes or airsealed boxes shall be installed. CIE COUNTY HVAC register boots HVAC register boots that penetrate building thermal envelope shall BOCC be sealed to the sub -floor or drywall. ID Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire %prinkler cover plates and walls or ce-61ina-g. N-11 M 0""Chav a. in aaamon, inspecrion or log Walls snail oe In aGooroance wan me provisions of ICC-400. jr 1 IV it `V v u - 9/17/2019 10:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1