HomeMy WebLinkAboutSOIL NUCLEAR GAUGEYCY1W- W - \,Iu-(>- V 1,'0"
1 Soil Nuclear Gauge Client: Project:
Cv A Report Date: 9/26/2019 Big Dog Repair 19-5966.00
Test Method: ASTM D 6938 855 SW McCoy Avenue 1815 Buttonbush Circle �I)A
ED
Port St. Lucie Port St. Lucie, FL 34953 Palm City, FL 9�'U
607 MW omm ^�i B�f811�9�
Pod NW Ccie,FL 4Cove F6J 1G 1
M Port St. Lucie, FL 34986 �
W Phone: 772-92435751 Fax: ] 2-924 3580
Test Results
i
Optimum Maximum In Place In Place Probe Min/Max
�l Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp.
Test # Of Date ProctorlD Method Classification % (p % (Pc(in) Compaction %) Remark
1 9/23119 P-1 N/A 12.3 104.2 11.0 1 100.2 12 96 95 / 105 Pass
Test Information
Gauge
�` -- Test # Test Location I Elevation Reference Make / Model / SN / Calibrated Field Technician
1 Slab on Grade: Golf Cart Garage Addition, Center of slab 0-1 Troxler / 3430 / 34161 / Guamied, Masonn
Remarks Comments
Pass: Tests results comply with specifications Tests am "Direct Transmission' (Method A) unless probe depth Is noted as
'Backscaaer'. Gauge calibration data on file with the testing agency. RECEIVED
SEP 3 0 2019
ST. Lucie County, Permitting
\k ltlil 111////,
N. KENT'%,
i
I _�W6321
f72019
,I rt Kent, P . IZ_
P p�fessionpeer #298
St"a��(' FI�Gt'belD P. • •' G��;
S TONAL 1EO kN`
Test Reports shall not be reproducedi, except in full, without the written approval of GFA International Inc. Page 1 of 1
Digitally signed printed copies of this 6cument are not considered signed and sealed and the signature must be verified on any electronic copies.