Loading...
HomeMy WebLinkAboutPOOL PLANS2.7 VS FLO PRO PERFORMANCE CURVES ,m 43 39 35 ow5ft° HIG SEE _ " . 50 :gg _ S 17 13 211 10 _ .__ - _4 L 0 o 0 10 20 30 40 50 60 70 60 m IN 110 In I30 IQ ,60 160 in ISO 190 200 Flow Rate Gallon, P,, Menu, IGPMD GENERAL NOTES 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN -PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN. 4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40. 5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK -WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR. 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM. 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK -WASH REQUIRED. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING - Waterway Technical Bulletin: VG82008 640-18XX V B" Round Tru H9 Drain and Frame Watemay drain mmrs are compdam to the latest Consumer Safety Product Commission requiremens(CPSQ. listed and Certified and Tested In stria accordance to the requirements of ASME AT I2.19S-2007and ASME A112.19sie2008 as defined %: �Vi.IV �•`-a;Ai in CPSC letter dated April & WIT 1. CelOfied by. Underandars Laboratories, In" 2929 E. Imperial H41%W,, Wee IOD. Sma, CA 929216729. Watelwry 60311a V terms mce sand names are available M: ii U White M Bla k O Gray Q DRkGmy O Settle MBIA9 Aeeooduok"a" mwea, "mnkbneelue,"mob .w,.ra>:Nvwuawwrmvnn;asme;n ., ,rra"rol. eaManl"n"dmbb WpWL .rr .. - Wud"ukpoebamiabkobaav"n;e ..... � ., , M,vYyYPN"ikbel"sYen vm, , ueu. , v„n� no.i mpn o � ^.• .. ••.... .a.wa�m"k.a<w.meekwrmaseml�w*«w. Ws®.m.dtmsmN=.+•.alm:.u+emwu..,cswaN�aa� A"MyeMUBA1anH1ml. 4ud#u Besniptan She Tatal Open Ant Flea Fbb Ogre WaAFbb Rate Rmflate OM 5"ar,ace. GPM GPN 51.51ft/u 6,11111 XV TM So Y - I" 1S3 96 68 -. Panlla Oewipdon Sri' 02-714 Hb2c00y 8'Nlb0ahaw rTa Pks5Relaitc Bi3-714M e'iv0o00kparze M9�1` wanxx GI0 . �t�rtuay ANSI-7/ANSI-I5 EC PUMP = 2.7HP JANDY VARIABLE FLO PRO VARIABLE OW SPEED - 36 GPM MAX IGH SPEED = 120 GPM @ 46 TDH " SUCTION PIPE @ 120 GPM = 5.63 FT/SEC. 8 FT.ISEC. MAX. - SUCTION LINES) " BRANCH PIPE @ 60 GPM = 4.13 FT./SEC. 6 FT./SEC. MAX. - PRESSURE LINES) .5" PRESSURE PIPE @ 120 GPM = 8.43 FT./SEC. (10 FT./SEC. MAX. - PRESSURE LINES) 200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM BACKWASH VALVE NO (1) #5 REBAR OR (2) # 3 REBAR REBAR SHALL BE COVERED 6" BY A MINIMUM OF 2.5" NO SCALE WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 20" max. N.T.S. OUTSIDE ANGLE OF REPOSE 18" MIN. (ENTIRE PERIMETER) 6' AND FURTHER =4" THICK WALLS3REBAR REBAR O.C.EACH O.C. EACN WAY 3' TO T = 6" THICK WALLS W/#3 REBAR 1& 12" . EACH WAY D TO 3' 8' THICK WALLS W/#3 REBAR @ iT' O.C. EACH WAY PAVER DECK OR CONCRETE DECK C W.L. 9ft � N.T.S. saL III SOLID COPPER BOND - WIRE W/APPR. CLAMPS V' (ONE ON EACH SIDE OF i POOL 4 TOTAL) O4 8 GAUGE SOLID COPPER WIRE - Wq 7 2rcaa I EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: _ `SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT E(2UIP0_TENTIAL BONDING GRID DETAIL NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES MINIMUM 18" (MAXIMUM 24"( FROM EDGE OF POOL ARC ' COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED PER N.E.C. 2014 SEC. 680.2E AT C.O. OF THE SWIMMING POOL (WHERE ADOPTED) EN TIRE POOL PERIMETER BURIED 4"TO 6- DEEP LU V a I ALL MACHINE DIG OOL DETAIL APPROVED MAIN DRAIN FRAMES AND GRATER PER V.C.B. ASME/ANSI 112.19.E-2007 38 ft. 4 i n . SCREEN BY PIONEER (2) JANDY DECK JETS 2:5 1.5" 1.5" R 30 ft. TILED BENCH --- EDGE m "EEP 3.5' DEEP "e CO COLOR LED COLOR LED I' \ I / VAC LINE \ / �/► 4 ft. 2 in. m DECO DRAIN TO DRAIN WAY FROM THE HOUSE. DECO DRAIN TO BE ATLEAST FROM HOUSE. DECO RAIN EXACT LOCATION TO BE DETERMINED IN FIELD. 10F FASCIA N HEIGHT X DOOR AND WINDOW ALARMS POOL BARRIER BY OWNER 5o1.17.1- R4501.17.3 AND ANSI/NSPI-5-1995 SAFETY BARRIER PER FRC R4501.17.1- R4501.17.3 & ASTM5034-95, ASTM D3787- 89, ASTM 653-96 FOR RESIDENTIAL AND THE ANSVAPSP-7 20a6 FOR SUCTION ENTRAPMENT AVOIDANCE MINIMUM (2). SUCTION LINES PER PUMP 3 FT. SEPARATION OR SEPARATE PLANES 3 FT. MIN. 2.5" LINE TO FIRST TEE. 3" SUCTION LINE MAX 181 G.P.M. L TO FILTRATION PUMP LI NES INES FROM SUMP INESE 6 FPS MAX N.T.S. TRUSSED ROOF PATIO REMOVE AND REPLACE EXISTING PAVERS MISC. NOTES N.T.S. 1. ALL STEPS AND SWI MOUT BENCH EDGES WILL NAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT ARE WHERE DECK RAISED +6" ABOVE POOL UND WIRE HANDRAIL BONDING DETAIL 48"MAX Fr WHERE APPLICABLE � G PER NATIONAL ELECTRICAL CODE WATER DEPTHI-10" MIN. TIS MI. OF 10"W DE. 12" MAX. OT GREATER THAN I2" EXCEPT IF MORE 0 o THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 3000 PSI. N.T.S. *LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 EQUIPMENT VERIFY PAD EXACT PER FBC LOCATION IN R4501.22 FIELD WITH SUPERVISOR LINE TO :ST TEE 2.5" LAYOUT Nde T. S P O POOLBONO M2008 N.T.S WATER ONDING WIRE TO GRID PB-2008 LOCATION OF WATER BOND BY POOL EQUIPMENT IN ACCORDANCE WITH 680.2 C POOL WATER SHALL BE IN DIRECT CONTACT WITH AN APPROVED CORROSION -RESISTANT CONDUCTIVE SURFACE THAT EXPOSES NOT LESS THAN 9INCHES (5800 MM) OF SURFACE AREA TO THE POOL WATER AI ALL TIME. EQUIPMENT LAYOUT N.T.S. LEGEND D 1. 2.5" RETURN TO WATER FEATURE 2. 3" WATER FEATURE MAIN DRAIN LINE 3. 2.5" SPA MAIN DRAIN LINE FOR FILTRATION 4. 1.5" VACUUM LINE 5. 2.5" MAIN DRAIN LINE 6. 2" POOL RETURN LINE A. JANDY 2.7 FHPM VARIABLE SPEED W/APPR HAIR & LINT STRAINER B. 1.5" TO WASTE OR TO GROUND C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE D. VALVES (TYR) E. JANDY "TRU CLEAR" SALT SYSTEM F. ELECTRIC HEAT PUMP ELECTRICHEATOVERLOAD PUMP ELECTRICAL DIAGRAM WBUILT-IN OVERLOAD SWITCH Wl3-#6 THHN CU WITH -IN 3/4" CONDUIT Bo AMP POOL PANEL W/(3) - #4 THHN CU WITHIN 1" W.P. DISCONNECT ELECTRICAL CONDUIT N.T.S. VARIABLE SPEED FLOPRO PUMP MOTOR #8 SOLID CU GROUND WIRE WBUILT-IN OVERLOAD SWITCH W13-#10 THHN TO EXISTING PANEL CU WITH -IN Y" CONDUIT S.P.S.T. TOGGLE SWITCH STIMECLOCK DISCONNECT (3) POOL LIGHTS (GFI NOT REQUIRED) W.P. DISCONNECT TRU CLEAR SALT SYSTEM WBUILT-IN OVERLOAD SWITCH WM 910 THHN /�T(,/ 30" MIN. CU WITH-INN'CONDUIT /,(/O - 04 CLEARANCE 1=tEVIEWE[ IN FRONT 1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. 3. g� H SUBPANOF 2. 3-#12 THHN CU WITHIN'A" MIN. CONDUIT FOR POOL LIGHT (S) .,+'Ol7JE COME 4. ALLLOUND POOL PUMPS TOG CALL BOXES, FI PROTECTED PER NEC 680.22 (B) TS, MOTORS, ETC, WITH #8 SOLID'BARE COP " L1 V 1/"v�IE C BOCC • BURIED POWER LINES N.T.S. CONCRETE DECK N.T.S. POOL PATIO WATER LEVEL NOTE: REMGVE GRATE& OVERPOUR WELL POINT PLUG FROM BEND INTO D CK 48" Z (OR CAP TIL MAIN DRAIN & ATTACH AUX. . UMP LINE WHEN EMPTWN WHERE .T Poo APPLICABLE FROM 6"X6" TIL 4" SLAB T POWER INTERIOR LIGHT 2500 FIBii CONDUIT SUPPLY GRATE SHALL FINISH TYPIC UNDERWATE UNDERWATER BE SECURED /Y TYP. 4 SECTION & NO IN PLACE SO WALL LIGHT LIGHT DETAIL NICHE THAT TOOLS WELD POINT T l b (NO SCALE) ARE REQUIRED taa APPROVED FOR R MOVAL STEEL-TEX FORM GROUND CLAMP 6' TYP. R KRAFT WALL FLOOR #3 @ 12" O.C.B,W. CONTINUOUS BOND WIRE THREADE NOTE: FOR DEPTHS POOL FINISH �: COMMON POOL STEEL, PLUG REATER THAN 6' ADD 1- RAILS & EQUIPMENT in COVE AR @ 6" O.C. GRAVEL BED TO PUMP0. T.S. • APPROVED WITH THE 2017 FLORIDA BUILDING CODE 6TH EDITION FOR RESIDENTIAL SPECIFICATIONS MAX. WIDTH 1806" MAX. LENGTH 30' FILTER IDY 1.65HP SKIMMER MIN. FLOW 25 GPM SURFACE AREA OF POOL - 478SQ FT 97LN FT A. ALLEN ENGINEERING LLC, CA NO. 33042, 2367 7"' STREET, LA VERNE, CA, 91750 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY MINIMUM BUILDING CODES. ;'Ixe / AARON H. ALLEN PE, FL REG. NO. 86620 FL JOB NAME:_BIEDKA ADDRESS: 9046 PUMPKIN RIDGE RD. SAINT LUCIE WEST, FL 34986 PERMIT NO.: DATE DRAWN:JULY 22 2019 DRAWN BY: BOBBY AUSTIN CHECKED BY AARON H. ALLEN DESIGNER APPROVAL: _ CUSTOMER APPROVAL: SCALE: 1/4" = V SCANNE0 R BY j C o St.LUcieCoL;, CONCRETE POOLS, INC. DECK �/ 1 ROW OF WATERLINE TILE C WATERLI4 /," THICK 3.5' PILE CO #3 STEEL @ 12" O/C E.W. WA- $H/- FLOOR.SLOPE T�z• NO, FLOOR SLOPES SHALL BE SLC .. REASONABLY UNIFORM AND GREATER COMPLY WITH ARTICLES 6.61 THRU 563 THAN L:41 27' THE SLOPE OF THE FLOOR FROM TYPICAL SECTION THRU POOL (NO SCALE) 300