Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEAD""! FOP.M R405-2017 (� r� 9 rrp G`Po ir�� ,,,-'FLORIDA OP FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING STRUCTI( Florida Department of Business and Professional Regulation - Residential PeMmance Method Project Name: Adams Homes - 2010 Model - 5113 Birch Drive Builder Name: Adams Homes SCANNED Street: 5113 Birch Drive Permit Office: St. Lucie County @�C1�101fNC� City, State, Zip: Fort Pierce , FL, 34982 Permit Number: BY Owner: Adams Homes - 2010 Model Jurisdiction: St. Lucie County St Lucie Coo*Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing _ New (From Plans) 9. Wall Types(1488.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block-- Ext Insul, Exterior R=4.1 1328.00 ft' Number of units; if multiple family 1 b. Frame - Wood, Adjacent R=13.0 160.00 ft- 4. Number of Bedrooms 3 c. c. N/A d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (2010.0 sqft.) R= ft' Insulation Area 6. Conditioned floor area above grade (ft') 2010 a. Under Attic (Vented) b. N/A R=30.0 2010.00 ft' R= ft' Conditioned floor area below grade (ft') '0 c. N/A R= ft' 7. Windows(156.0 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Hall, AH: Laundry R ft' 6 130 a. U-Factor: Dbl, U=0.65 150.00 ft' SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 6.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 41.5 SEER:15.00 C. U-Factor: N/A 0= SHGC: ft' d. U-Factor: N/A 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 41.5 HSPF:8.50 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.252 14. Hot water'systems 8. Floor Types (2010.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2010.00 ft' b. Conservation features EF: 0.950 b. N/A R= ft' None c. N/A R= ft' 15. Credits CF, Pstat Glass/Floor Area: 0.078 Total Proposed Modified Loads: 55.90 PASS Total Baseline Loads: 58.73 1 hereby certify that the plans and specifications covered by Review of the plans and -'Vf[E S`1TA this calculation are in compliance with the Florida Energy specifications covered by this D p Code. ` calculation indicates compliance yW /;r� % o 'ds� with the Florida Energy Code. !� /ro,_ ' , x; ;•;,,+, PREPARED BY: Before construction is completed „YO DATE: 4-10-19 this building will be inspected for compliance Section d I hereby certify that this building, as designed, is in compliance with the Florida Fe2rgy with 553.908 Florida Statutes. t Code. 0D iNE� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - uumpnance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 4/10/2019 4:20 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 F0QM R405-2017 INPUT SUMMARY CHFCKI IST RFonOT - PROJECT Title: Adams Homes - 2010 Model - Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2010 Lot # Owner Name: Adams Homes - 2010 Model Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Adams Homes Rotate Angle: 0 Street: 5113 Birch Drive Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Single-family , FL, 34982 New/Existing: New (From Plans) Comment: CLIMATE / v Design Temp Int Design Temp Healing Design Daily Temp Design Location TMY Site 97.5 %— 2.5 % Winter Summer Degree Days Moisture Range FL, Fart Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2010 16080 ' SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Master Bath 162 1296 No 0 1 Yes Yes Yes 2 WIC 2 30 240 No 0 1 No Yes Yes 3 WIC 1 30 240 No 0 1 Yes Yes Yes 4 Master Bedroom 268 2144 No 2 1 1 Yes Yes Yes 5 Study 108 864 No 1 1 Yes Yes Yes 6 Foyer 60 480 No 0 1 Yes Yes Yes 7 Dining Room 108 864 No 2 1 Yes Yes Yes 8 Laundry 84 672 No 1 1 No Yes Yes 9 Bedroom 3 178 1424 No 2 1 1 Yes Yes Yes 10 Bath 54 432 No 0 1 Yes Yes Yes 11 Bedroom 2 210 1680 No 2 1 1 Yes Yes Yes 12 Kitchen 265 2120 Yes 2 1 Yes Yes Yes 13 Living Room 368 2944 No 2 1 Yes Yes Yes 14 Hall 85 680 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bath 25 ft 0 162 ft' 1 0 0 2Slab-On-Grade Edge Insulatio WIC 2 1 ft 0 30 ft' 0 0 _ 3 Slab -On -Grade Edge Insulatio WIC 1 6 ft 0 30 ft' 1 0 0 _ 4 Slab -On -Grade Edge Insulatio Master Bedroom 32 ft 0 268 ft- 1 0 -- 0 4/10/2019 4:20 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPI IT CI IIVIMeDV rruorvr le� mom, m, -- — -- .w.��wr r�Lr VRI - FLOORS # Floor Type 5 Slab -On -Grade Edge Insulatio Space Perimeter Perimeter R-Value Study 9 ft 0 Area 108 ft' Joist R-Value Tile Wood 1 0 Carpet 0 6 Slab -On -Grade Edge Insulatio Foyer 5 ft 0 60 ft. 1 0 0 7Slab-On-Grade Edge Insulatio Dining Room 9 ft 0 108 ft' 1 0 0 8Slab-On-Grade Edge Insulatio Laundry 1 ft 0 84 ft- 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 3 14 ft 0 178 ft- 1 0 0 — — _ 1 OSlab-On-Grade-Edge-Insulatio — -- Bath — - 6 ft- 0 54 ft' — _- -- 1 —0 0-- 11SIab-On-Grade Edge Insulatio Bedroom 2 30 ft 0 210 ft' _—_ 1 0 0 12SIab-On-Grade Edge Insulatio Kitchen 14 ft 0 265 ft- —_ 1 0 0 13SIab-On-Grade Edge Insulatio Living Room 16 ft 0 368 ft- 1 0 0 14Slab-On-Grade Edge Insulatio Hall 1 It 0 85 ft. 1 0 0 ROOF Roof # Type Materials Area Gable Area Roof Color Solar Absor. SA Emitt Tested Emitt Deck Tested Insul. Pitch (deg) 1 Hip Composition shingles 2248 ft- 0 W Medium 0.6 No 0.9 No 0 26.6 ATTIC / it # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2010 ft- N N CEILING # Ceiling Type 1 Under Attic (Vented) 2 Under Attic (Vented) 3 Under Attic (Vented) 4 Under Attic (Vented) 5 Under Attic (Vented) 6 Under Attic (Vented) 7 Under Attic (Vented) 8 Under Attic (Vented) 9 Under Attic (Vented) 10 Under Attic (Vented) 11 Under Attic (Vented) 12 Under Attic (Vented) 13 Under Attic (Vented) 14 Under Attic (Vented) Space Master Bath WIC 2 WIC 1 Master Bedroom Study Foyer Dining Room Laundry Bedroom 3 Bath Bedroom 2 Kitchen Living Room Hall R-Value 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Ins Type Batt Batt Batt Batt Batt Batt Batt Batt Batt Batt Batt Batt Batt Batt Area 162 ft- 30 ft- 30 ft- 268W 108 W 60 ft� 108 ft. 84 ft- 178 ft- 54 it- 210 ft- 265 ft- 368 ft. 85 ft- Framing Frac Truss Type 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 4/10/2019 4:20 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPIIT RI IMMAPV r-141=rkl 14ZT DGDnDr - WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 S Exterior Concrete Block - Ext InsMaster Bath 4.1 11 0 8 0 88.0 ft' 0 0 0.6 0 2 W Exterior Concrete Block - Ext InsMaster Bath 4.1 14 0 8 0 112.0 W 0 0 0.6 0 _3 S Exterior Concrete Block -Ext Insul WIC 4.1 6 0 8 0 48.0 ft- 0 0 0.6 0 4 E Exterior Concrete Block - Ext In3dbster Bedro 4.1 14 0 8 0 112.0 ft- 0 0 0.6 0 5 S Exterior Concrete Block - Ext Inidbster Bedro 4.1 18 0 8 0 144.0 W 0 0 0.6 0 6 E Exterior Concrete Block - Ext Insul Study 4.1 9 0 8 0 72.0 ft' 0 0 0.6 0 7 E Exterior Concrete Block - Ext Insul Foyer 4.1 5 0 8 0 40.0 ft' 0 0 0.6 0 _ 8 E - Exterior Concrete Block -Ezt Ins11ning Room 4.1 9- 0 8 0 -72.0 fP - 0 - 0 0.6 0 9 N Exterior Concrete Block - Ext InsiBedroom 3 4.1 14 0 8 0 112.0 W 0 0 0.6 0 _ 10 N Exterior Concrete Block- Ext Insul Bath 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 _ 11 N Exterior Concrete Block - Ext Insdbedreom 2 4.1 15 0 8 0 120.0 W 0 0 0.6 0 _ 12 E Exterior Concrete Block - Ext lnsdiedroom 2 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 13 W Exterior Concrete Block - Ext Insd3edroom 2 4.1 14 0 8 0 112.0 ft- 0 0 0.6 0 14 W Exterior Concrete Block - Ext Insul Kitchen 4.1 14 0 8 0 112.0 ft- 0 0 0.6 0 15 W Exterior Concrete Block - Ext Insbfving Room 4.1 .16 0 8 0 128.0 W 0 0 0.6 0 _16 N Garage Frame - Wood Laundry 13 7 8 56.0W 0 0.25 0.600000 0 17 N Garage Frame - Wood Bedroom 3 13 13 8 104.0 ft- 0 0.25 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood Foyer None .39 3 6 10 20.5 ft- 2 W Wood Kitchen None .39 2 10 6 10 19.4 W WINDOWS Orientation shown is the entered, Proposed orientation. / V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Double Yes 0.65 0.3 N 6.0 ft' 2 ft 0 in 1 ft 4 in None None 2 E 4 Metal Low-E Double Yes 0.65 0.25 N 30.0 ft' 2 ft 0 in 1 ft 4 in None None 3 E 6 Metal Low-E Double Yes 0.65 0.25 N 15.0 W 2 ft 0 in 1 ft 4 in None None 4 E 8 Metal Low-E Double Yes 0.65 0.25 N 15.0 W 2 ft 0 in 1 ft 4 in None None 5 N 9 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None 6 W 13 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 2 ft 0 in 1 ft 4 in None None 7 W 14 Metal Low-E Double Yes 0.65 0.25 N 30.0 f12 2 ft 0 in 1 ft 4 in None None 8 W 15 Metal Low-E Double Yes 0.65 0.25 N 30.0 ft- 2 ft 0 in 1 ft 4 in None None 4/10/2019 4:20 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY t^HFrWI ICT RGunoT - GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 638 ft' 638 ft' 20 ft 8 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1876 102.99 193.69 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 41.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 41.5 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation .1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS / V # — Supply — Location R-Value Area — Return --- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 130 ft' Hall 15 ft' Default Leakage Laundry (Default) (Default) 1 1 4/10/2019 4:20 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 F013M R405-2017 INPUT SUMMARY CNFCIII ICT 171=10nOT TEMPERATURES - Programablfre Thermostat: Y Ceiling Fans: Ian VentinMa [X] Jan Feb [X] Mar rr ]] [r Ap € n ri [f 4 Oct Ov Dec g Feb ]RS [X] Mar [X� Apr May Jun �X� JulJul [X� Aug [X� Sep €Xj Oct �Xi Nov Dec Thermostat Schedule: HIE 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD)-- -- AM PM --66 68 66 68 66- 68 66-- 68 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction .Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 Master Bath Default(8 lbs/sq.ft. ft. ft 0.3 WIC 2 Default(8 lbs/sq.ft. ft' ft 0.3 WIC 1 Default(8 lbs/sq.ft, ft' ft 0.3 Master Bedroom Default(8 lbs/sq.ft. ft' ft 0.3 Study Default(8 lbs/sq.ft. ft, ft 0.3 Foyer Default(8 Ibs/sq.fl. ft' ft 0.3 Dining Room Default(8 lbs/sq.ft. fN ft 0.3 Laundry Default(8 Ibs/sq.ft. ft' ft 0.3 Bedroom 3 Default(8 lbs/sq.ft. fl' ft 0.3 Bath Default(8 Ibs/sq.ft. ft' ft 0.3 Bedroom 2 Default(8 lbs/sq.ft. ft- ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft' ft 0.3 Living Room Default(8 lbs/sq.ft. ft' ft 0.3 Hall Name: Rating Compant: Signature: Date: 4/10/2019 4:20 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2617 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Adams Homes-2010 Model-5113 Birch Drive Builder Name: Adams Homes-2010 Model Street: 5113 Birch Drive Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL, 34982 Permit Number: y Owner: Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce w x U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceiling/soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. Knee walls shall be sealed. with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barder. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors (including The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to above -garage maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub on exterior wall The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids of Ipp walls shall ua m BMm��...er. one .......:..:...... ... .�....,,, a. In addition, inspection 8/13/2019 8:50 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Enerqv Conservation. 6th Edition Jurisdiction: St. Lucie County Permit #: r, x zvs `vrrt+7".;�* syaj c " ',�+ic,✓, 5 1'.� _; r,�r A*' ew 4--SM >"'i" {n-�.ry :'' �., k"i,. `w,n, 3u 3 ia4o4'v L '.J� , F S'Cj 1 y T 2 ^�' }aN 1(1��` y Job Information - t .- , r yam r b a loff,..a. ,_ p Builder: Adams Homes-2010 Model Community: Lot: NA Address:-5113-Birch-Drive - - — — - - -- - - - - — - City: Fort Pierce State: FL Zip: 34982 Air, Leakage Test Results 'Pass/ gresultssmust meef a �herthe Perfo P�escrr bve o th ` manta �p �RlMethod r ; A- METHODThe bulldmg dwelling tie OPRESCRIPTIVE or umt shall testedan'uenfied as havmg an airleakage`2te of not exceedmg 7 air2. 1s cfian es er'hourat a pressure of 0 2 mch W g (50 Pascals) In Climate Zopes 1 and '>�� '�`"� '� ��3 _21� �. ,�.rl p,, 7 li 'the selected gCH(SOJ va ueEa shown on Form R405-2017 (Perfofmance)`Io bR�406-2017 w: 4 (ERf) secfion labeled asmfiltra6onasii6;'secLon ACHSOx 4 r'" : 'r !,[�(-l($0) sp`ecifled orr Fo[m R40$ 2017 Energy Calc (Performance) dF R406 20 7; " e =`" '(ERI} 5.000 v s x. s .,. ,.- w_�' s. �. , ? ?. ,... �c r'' e e✓ ,...r..: , ... � w �.., x 60 _ 16080 — Method for calculating building volume: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(0, (9), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exteriorwindows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the lest, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. � Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with ilia 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 8113/2019 9:30:07 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts _ _ _ _ _ _ _R 6.0 _ - 2-Single-family or multiple -family- - -- - - 2.--Single=family - - -b)-Return ducts R 6.0 3. No. of units (if multiple -family) 3. 1 c) AHU location Laundry 4. Number of bedrooms q, 3 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 2010 7. Windows, type and area a) U-fador:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.252 c) Area 7c. 666.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c, 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly C) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 13. Cooling system: Capacity 41.5 a) Split system SEER b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 15.0 14. Heating system: Capacity 41.5 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 8.50 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 1061. 13.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes 11 a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11 d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. r Builder Signature: Date: /C( Address of New Home: 5113 Birch Drive City/FL Zip: _ Fort Pierce, FL 34982 8/13/2019 8:50:42 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 y y, 'S r e, *-wrightsoft Project Summary Date: Entire House By: SCANNED Quick Calcs, Inc. BY Y 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone:7724666799 Email: quickcalcs@aol.com Slpp . Lucie �;(111* Project Information For: Adams Homes - 2010 Model 5113 Birch Drive, Fort Pierce, FL 34982 Notes: RECEIVED AUG 14 2019 -- -ST-Lucie County, -Permitting- - Desipla Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 'F Inside db 70 °F Inside db 75 'F Design TO 28 °F Design TO 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 17367 Btuh Ducts 6763 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24130 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (fta) 2010 2010 Volume (ft3) 16080 16080 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 86 43 Heating Equipment Summary Make Carrier Trade CARRIER Model 25HBC542A00300 AHRI ref 9155360 )oint= 28 °F Sensible Cooling Equipment Load Sizing Structure 22308 Btuh Ducts 8241 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 29022 Btuh Latent Cooling Equipment Load Sizing Structure 4791 Btuh Ducts 2675 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 7466 Btuh Equipment Total Load (Sen+Lat) 36488 Btuh Req. total capacity at 0.70 SHR 3.5 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond 25HBC542AO0300 Coil FX4DNF043L AHRI ref 9155360 8.5 HSPF Efficiency 12.5 EER, Sensible cooling 42000 Btuh @ 47'F Latent cooling 28 °F Total cooling 1383 cfm Actual air flow 0.057 cfm/Btuh Air flow factor 0.50 in H2O Static pressure Load sensible heat ratio Backup: Input = 7 kW, Output = 23727 Btuh, 100 AFUE 15 SEER 29050 Btuh 12450 Btuh 41500 Btuh 1383 cfm 0.045 cfm/Btuh 0.50 in H2O 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ti -�:- wNghlbsofY 2019-Apr.1016:17:42 .--+.—.-. RightSuite@ Universa1201919.0.01 RSU08101 Page 1 IM..Adams Homes -2020 Model- 5113 Birch Dmre.rup Cale =MA Front Door faces: E FILE C®Py wrightsoft Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By 317 St. Lucie Lane. Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Entire House Master Bath 2 Exposed wall 166.0 it 25.0 It 3 Room height 8.0 it 8.0 ft heat/cool 4 Room dimensions 1.0 x 162.0 It 5 Room area 2010.0 ft2 162.0 ft' Ty Construction U-value I Or HTM Area (ft') I Load I Area (ft2) I Load I number (B[uN([2-°F71 (Btuh/ft') or perimeter (ft) (BI or perimeter (ft) (Btuh) Heat I Cool Gross I N/P/S Heat Cool Gross 14/P/S Heal Cool 6 Yy 13A-0ocs - - 0.143 n -4W 1 —2801-2(51 1061 ----580 0 --•--0 0 I--G 9A5-2om - _- s _.. _0.770 n _.,2156 . _19.31 -_- „15 ��_., _0 ._ ..,...323 _ 290 ___ __0 .___ _ 0 ., �„_ , ,o ._e ... 0 13A4ocs 0.143 a 4.00 2.19 304 224 895 489 0 0 0 0 4A5-2om 0.770 a 21.56 45.10 60 4 1294 2706 0 0 0 0 11 11DO 13A-4ors -rye 4A5:2om-_.,._� ._�. 0.390 0.743 __.__0.770 a s _.s _ 10.92 400 _21.56 10.34 2:19 _ _79.31, 20 2_ _,___6 _ 20 274 __•�,Y„6 223 _1097 __- _ 2_129 211 599 -_ ..;,i t6 0 88 „_.___.-_ 6 0 y 82 __,.6 0 J 328 ..... __129 0 '779 ':____1 6 _ W 13A-4ocs 0.143 w 4.00 2.19 464 370 1480 809 112 112 448 245 4A5-2om 0.770 w 21.56 45.10 75 5 1617 3383 0 0 0 0 0.390 w 10.92 10.34 19 19 210 C__._ 76B$0ad__ -,-.� ____0.032 ._ __-090: ____1.60 ____ _-__2010 .____, '____2010 __y, .-1801 _199 ___._3216 _— ------ ...__._162 __-_762 _'__-__145 „__. .259 F. 22A tot .,_.___ __.. „. _. ,0.989 Y 27.69 ,-__ 0.00 2010 - 166 _ - _-4597 _ _0 - 162 ___ _25 692 0 6 c) AED excursion 353 S6 Envelope loss/gain 74728 12951 1744 744 12 a) Infiltration 2639 707 397 1 106 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 15 3450 0 0 Appliances/other 5200 0 Subtotal (lines 6 to 13) 1 17367 22308 1 1 2141 850 external load 0 0 0 0 Less transfer 0 0 0 0 [Less Redistribution 0 0 0 0 14 Subtotal 17367 22308 2141 850 Duct loads 39% 37% 6763 8241 39% 31% 834 314 Toal m load 213830 0149 311383I 2171 115634 Airrrequired (cfrn) I I I 3I I I I Calculations aooroved by ACCA to meet all reouirements of Manual J 8th Ed '!•1'f wr!131�t�- 2019-Apr-7016:17:42 A RightSuile® Universal 201919.0.01 RSU08101 Page 1 ...Adams Homes - 2020 Model - 5113 Birch Ddve.rup Cale c M.18 Front Door faces: E I wrightsoR Right-J® Worksheet Job: Entire House Date: Quick Callas, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name WIC WIC 2 Exposed wall 0 ft 6.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 6.0 ft 30.0 ft2 5.0 x 6.0 ft 30.0 ft2 Ty Construction U-value I Or HTM I Area (ft2) Load I Area (R2) Load number (BtuNft'-°Fy (BtuN(N) or perimeter (ft) (BNh) or perimeter (ft) (Btuh) Heat I Cool j Grass I N/P/S I Heat I Cool Grass I N/P/S I Heat Cool 6 W---.-13A-0ocs---.-- -`0:743 n4-400 '2:19 0 -� 0 _ 0 -°00 --J---^0 ---0 --1U I-G 4A54om_ ._._ ._ _..0.770 _...n_ ._ 21.56 -19.31 ._.0 __ _,0 ."_0,. _:0 '-:0 .--0 „. 0 _ ::_0 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 11 �DD 4A5.20m i7D0 0.770 0.390 a e_ 21.56 10.92 45.10 70.34 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. �73A-4ocs�_-- 9A8-2om_�___.�.. 0.143 _..._-0.770_.s.-2156 s 400 .�2:19 19.31 o _-.:0 o �;0_-0_,�_._.0,,. =- 0 �'�0 48 ,.-._0__.__ _ __ - 48 0___....__0 - 782 w. 105 .,..,..-.0 w 13A.4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 I--G III--DDD 4A5.2om 11D0 A6B-30ads -__.._ 0.770 0.390 ._._.,. 0.032 w w _..,_;._-_090 21.56 10.92 45A0 70.34 _.... _1.60 0 0 ...._.__30. 0 0 _-_-30 0 0 ;.__.27 0 0 .:.._..__48 0 0 _ _.90 0 0 t.._._._30 0 0 .._. ,27 0 0 _:..,:_..48 22A-tol__ _ _ -__0.989 _ _-_ 27.69... _ 0.00 _ -_30 0 0 0 30 ___6 _ _,. _ 166 --,.-.-0 6 c)AED excursion -3 -11 Envelope loss/gain 27 45 385 742 12 a) Infiltration 0 0 95 26 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 27 45 481 168 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistibudon Subtotal 0 27 0 45 0 481 0 168 15 Duct loads 39% 37% 10 17 39% 37% 187 62 AoteleQUomdl(cfm) 32 63 638I 2301 I I I I Calculations aooroved by ACCA to meet all reeuirements of Manual J 8th Ed. ' �!HtitsoTC- 2019-Apr.1016:17:42 RightBirch ®ve.rup sa1c=MJ8.Fo RSU08101 Page2 ..Adams Homes -2020 Model -5113 Birch Drive.mp CaIc=MJB Front Door faces: E wrightsofr Right-J® Worksheet Job: Entire House Date: Quick Callas, Inc. By, 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalm@aol.com 1 Room name Master Bedroom Study 2 Exposed vall 32.0 It ao It 3 Room height 8.0 it heat/cool 8.0 it heat/coot 4 Roam dimensions 1.0 x 268.0 It 9.0 x 12.0 ft 5 Room area 268.0 ft° 108.0 ft' Ty Construction U-value Or HTM I Area (ft') Load Area (ft') Load number (Stuh/ft'-°F (BluNft') or penmeter (f, I (BNh) I or perimeter (ft) I (Btuh) Heat Cool Gross NIP/S Heat Cool Gross NIP/S Heat Cool _6 —u. 13A-0ocs _7 p,i43 a - 400 219 .� - �` 0 --�—., _. _,_ —�=0 w 4A5-20m•_.. _. �_,_._. _0.770 _d. _: 21.56 ..'.79.31. _0t..>:._..0_..____-.0 N.-O.-..._.,.._..0 0 ___-, __0 __..«.Z0 13A 4ocs 0.143 a 4.00 2.19 112 82 328 179 72 57 228 125 4A5-20m 0.770 a 21.56 45.10 30 2 647 1353 15 1 323 677 11 11DO 0.390 e 1092 10.34 0 0 0 0 0 0 0 0 W __ 73A flocs A 0.143 's _ 4 00 2.19 144 144 -. 577 315 0 - - 0 '- -G 4A5-2om___.. _ ,.,...,: -0.770 s_ __2156 _ 19.31 v_ _: l) _._,__.0 _-.-.--0 �.__ 0,._,,,,__ _0 _ __ —.0 _...,.�_ 0, ,_-;:—_0 13A-40cs 0A43 w 4.00 2.19 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.10 0 0 0 0 0 0 0 0 11D0 0.390 w_ 10.92 10.34 0 0 0 0 0 0 0 0 C_.,__ _ 16B30ad. _...�.,. _-_�-..,0.032 ..,_.-Xg1Y „. __160 '._._...268 .e__ 268 _.__-240 '_. 429 __._ 108 _:— _708. _97.. _.,_773 F 22A-tDl _0.989 ,-_-. 27.69 0.00 268 _,32 -_____886 - 0 _-_ _108 __. _ _ 9 _.249 -,_ 0 6 c) AED excursion -172 -116 Envelope loss/gain 2678 2104 898 858 12 a) Infiltration 509 736 1 143 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 900 900 Subtotal (lines 6 to 13) 31871 3600 11047 2256 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3187 3600 1041 2256 15 Duct loads 39% 37% 1241 1330 39% 37% 405 834 INrtrequvedload 428 4223 1 30�00I (cfm) I I 254I I I 83I Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed -fi*- wrl9htsaf!- 2019-Apr-1016:17:42 A°C; RightSuite® U niversal 201919.0.01 RSU08101 Page ...Adams Homes -2020 Model- 5113 Birch Drive.rup Colo =MJ8 Front Door faces: E 'P+ wrightsofr Right-J® Worksheet Job: Entire House Date: sy: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalos@aol.com 1 Room name Foyer Dining Room 2 Exposed wall 5.0 ft 9.0 It 3 Room height 8.0 It heat/cool 8.0 ft heat/cool 4 Room dimensions 5.0 x 12.0 ft 9.0 x 12.0 If 5 Room area 60.0 fe 108.0 ft2 Ty Construction U-value I Or HTM I I Area (ft2) I Load I Area (ft2) Load number (Btuh/ft"Fy (Btuh/W) or perimeter (ft) (BNh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 1-6 -6 ..... �- ..._._ _...._ 73A-0ocs--: ..... -0.143 n T -=-400 ... -2'19 ----0 -•---0 -` 0 ---- '-0 '0 _- --�0=1=6 —'-'-0 4A5-2om ,. _- _ .._ ,0.770 _ n_ _:_21.56 ___19.31 r. ___0 „ _. -_0 _._-0 ... - __ 0 . _ _0 .. _ _..,_0 .. ..-.0 _-..._ .0 13A-40cs 0.143 a 4.00 2.19 40 20 78 43 72 57 228 125 4A5-2om 0.770 a 21.56 45.10 0 0 0 0 15 1 323 677 11 D 11D0 0.390 e_ 10.92 10.34 20 20 223 211 0 0 0 0 y-yyy1 '�-0'� 13A-0ocs 0.143 s �400 2.19 0 - 0 - 0 -� 0 0 0 0 WHO. AA5.2cm �...,._ ... _ _ 0.770 _ s _ _ 21.56 19,31 ._.,...,. 0 _....-_,_. 0 _0 ._-.. 0 .�._ _ -.0 --..._, 0 13A-0ocs 0.143 w 4.00 -- 2.19 .A 0 _m. �. 0 0 0 0 0 -,.. 0 0 4A5-2om 0.770 w 21.56 45.10 0 0 0 0 0 0 0 0 11D0 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C.._Y_ 16&30ad.__.W. -___0.032 -__.,-.0.90�60 __..__54 _. ........_96 ... _708 _108 ._.____97 .__...173 22A-tol_„-. _ - .._ �., -- .__0.989 _ :_ . 27.69, __ _%00 - 60 . _ 5 - 4-1 8 _._ . ___g8 _ _ 0 -_ __. 108 - 9 _249 _. 0 6 c) AED excursion -23 -fit Envelope loss/gain 493 327 898 913 12 a) Infiltration 79 21 143 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliancestother 0 0 Subtotal (lines 6 to 13) 573 348 1041 1412 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 11 18 14 Subtotal 573 348 1051 1430 15 Duct loads 39% 37% 223 129 39% 37% 409 128 Total room load 796 477 1461 1911 Air required (cfm) I 46I 22I I 84I 89 Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. -e}i- �r19tis'+otC- 2019-Apr-10 16:17:42 RightSuite® Universal 201919.0.01 RSU08101 Page ...Adams Homes -2020 Model- 5113 Birch Drive.rup Calc=MJB Front Door faces: E wrightsofr Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772A66-6799 Email: quickcalcs@aol.com 1 Room name Laundry Bedroom 3 2 Exposed wall 0 ft 14.0 ft 3 Room height 8.0 ft heatcool 8.0 ft heat/cool 4 Room dimensions 7.0 x 12.0 ft 1.0 x 178.0 ft 5 Room area 84.0 ft2 178.0 ft2 Ty Construction U-value Or HTM I Area (fP) Load I Area (ft2) I Load number (Btuh/ftMF� (Btuh/ft2) or perimeter (ft) (Stuh) or perimeter (fl) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 � 13A-0ocs -"-- - 0143 —n --400 --2'19-�0 ^0 =0 -- -0 li2 --97 �-388 --212 4A5-2om _ . _ - _. �0.770 --n. �..21.56 . 19.31 '_ _ 0 _.._. - 0 „. 0 . __.0 _ _ 15 :_ _ 0 ._- 323 _ "....:.290 VL13A-flocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 �—D 2 4A5-tom 0.770 a 21.56 45A0 0 0 0 0 0 0 0 0 11 11D0 a 10.92 10.34 0 0 0 0 0 0 0 0 W-'73A4ocs L•—G 4A5.2om _0.390 0,743 ._-0.770_s,_-2111 s —400 A19,31 ----0 __,—_„_0_ O _.�.0 .. _.. __A ._:0 _. _. __.0 _._._ 0 0 w 13A-4ocs 0.143 w 4.00 2.79 0 0 0 0 0 0 0 0 I—G II—� 4A5.2om 0.770 w 21.56 45.10 0 0 0 0 0 0 0 0 w_ 70.92. 0 0 0 0 0 9 0 0 _--DDD C------ 16B-30ad _ .__ ___-_-0.390 ____ 0.032 - ,_ _ ___ 0.90 _7.0._34 _ — 1.60 . '_._84 ___ . _ _, _ .. _ 84 _.. _ _ __-_ _75 ._,__... . _ .130 ._- _- _ __._778 ._. _778 ___... _.. -.__ __. 285 F _. 22Aipl- _ _._ _ _ U.989._=._ 27.69. __.. 0,00 ____ 84 _. _0._ .-_0 ... _p _778 .14 388 -_.. 388 6 c)AED excursion -53 -80 Envelope losstgain 75 81 1259 706 12 a) Infiltration 0 0 2231 60 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 2 460 Appliances/other 500 0 Subtotal (lines 6 to 13) 75 811 1482 1226 external load 0 0 0 0 Less transfer 0 0 0 0 [Less Redistribution ii 18 7 11 14 Subtotal 86 829 1488 1237 Duct loads 391 37% 33 306 39% 37% 580 457 Total room load 119 1136 2068 1695 Air required(cfm) I 7I fill I 1191 77I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. =.:!Rk solY 2019-Apr-10 16:17:42 RightSuite® Universal 201919.0.01 RSU08101 Page ..Adams Homes -2020 Model- 5113 Birch Dnve.mp Code =MJ8 Front Door faces: E I wrightsofC Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772A666799 Email: quickcalm@aol.com 1 Room name Bath Bedroom 2 2 Exposed wall 6.0 ft 30.0 ft 3 Room height 8.0 ft heat/cool &0 ft heallcool 4 5 Room dimensions Room area 9.0 x 6.0 ft 54.0 ft' 14.0 x 15.0 ft 210.0 fix Ty Construction U-value I Or HTM I Area (ft2) Load Area (tv) Load number (Btuh/ft,'F (BH:h/fl2) or perimeter (ft) I (Btuh) or perimeter (ft) I (Btuh) Heal I Cool Gross N/P/S j Heat Cool Gross NIP/S Heat Cool 6 -W- 13A-0ocs -` � '0,148 n : 4.00 --239 —�8 48 - 192 -. i05 V 120 — 120""480 263 !---G 4A5-tom _ ._ _ 13A-4ocs _- _..0.770 0.143 _.n, a __21.56 4.00 -19.31 2.19 _ .,.-.0 0 . 0 0 _ _... _0 0 -,.0 0 - _ v 0 8 _ __-0 8 0 32 _0 18 17 4A5-2am 11DO 13A flocs 4A5-tom -_ _ _,_ 13A-4ocs 0.770 0,390 0-'143 ._ 0.770 0.143 a a s _ s w 21.56 10.92 --- 400 ..21.56' 4.00 45.10 10.34 2.19 19.31 2.19 0 0 - —00 T _0 0 0 0 ,l__- _0 0 0 0 _-- 0 _-0 0 0 0 0 _ .__,_ 0 0 0 0 -0 0 112 0 0 - 0 _ __0 97 0 _ _.0 �- 0 . __ 0 388 0 0 0 212 W `G —G T 4A5-2am - 0.770 w w-..-_-090.. 21.56 45.10 0 0 0 0 15 1 323 677 C _ F. _-_- 16B-30ad., . 22A-lol— _ - - - _ ,. ._a .,0..032 _ _ 0.989 , y , - 27.69 _ L BO - _ 0.00 _-__754 _ _ _ 54 - -5-4 - .. _6 166 . _86 _ _ _ - 0 _. _210 .210 _-- � _..310 - - _30 831 336 --�_ 0 61 c)AED excursion -13 188 Envelope loss/gain 407 178 2243 1693 12 a) Infiltration 95 26 477 128 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 502 204 2720 2281 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 9 511 0 15 219 0 6 2726 0 10 2291 15 Duct loads 39% 37% 199 81 39% 37% 1062 846 1A, To loadd(cm) 7401 304I 32i71 371 3142 requtal ired I I I I Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed -44- wrl9ti oR- 2019-Apr-1016:17:42 Right-SuileO U niversal 201919.0.01 RSU08101 Page ..Adams Homes-2020 Model - 5113 Birch Ddve.rup Calc=MJ8 Front Doorfaces: E wrightsoft• Right -A) Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772.466.6799 Email: quickcalcsQaol.com 1 Room name Kitchen Living Room 2 Exposetl wall 14.0 ft 16.0 ft 3 Room height 8.0 ft hea6'cool 8.0 ft heat/cool 4 5 Roam tlimensions Room area 1.0 x 265.0 ft 2650 ft2 16.0 x 23.0 it 368.0 ft- Ty Consbucton number U-value (Btuh/ft2-°F I Or HTM (Btuh/ft2) I Area (ft-) or perimeter (ft) Load (Btuh) I Area (!t°) or perimeter (ft) I Load (Btuh) He Cool Gross N/P/S Heal Cool Gross N/P/S Heat Cool 6- 6 —2a9 - _ 19.31 0` .. , ..0 0 ,. __ _-0 "- —6 , --'—a 0 ---,- _,.a '0 ,.- __.a —0 _- _ -a `0 _.._ _ . ,0 ­0 a 0 Vy _ 13A;4ocs - 4A5-2om._. _. _.. - —-'0.143 - __0.770 n _n.-. '- 400 ..21.56. 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 11 4A5-2om 11DO 0.770 0.390 a a 21.56 45.10 10.34 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W _ 13A 4bcs�� 41,5r20m____., _ _ 0.143 __-0.770 S _s_ _10_92 400 2156 � -_2.19 ,19.31 —�11 -0 __ 0 --,_0 'V_^0 —_-0 _ _ 0 _ —__.0 _____ _—, 0 —,----a _.. 0' _ _ a _ 0 _o -_. _ 0 _ __a 13A-4acs 0.143 w 4.00 2.19 112 63 251 137 128 98 392 214 4A5-2om 0.770 0a390 w 21.56 10.92 45.10 10.34 30 19 2 19 647 210 1353 199 30 0 2 0 647 0 1353 0 A _..._.. 16&30ad.._._�.._. ___0.032 -w_ .,.- _ ___0.9D .. __. _.. _. 1.60 . --2 65 _. _ __265 _. _. ___..._237 _._._.__,.. _ -424 _ _ __., 368 _. _ _ .368 ._ _.. .._ _ 330 -. _._. _. _ ,._. 589. F_ _- 22A-tol-_,__„ . - _27.69 _.. 0.00 - -_265 _ ---388 -- - 0 ._-.__ 368 , 61 c)AED excursion 349 413 Envelope losslgain 1734 2462 18121 2569 12 a) Infiltration 223 60 254 68 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 2 460 2 460 Appliances/other 2000 900 Subtotal (lines 6 to 13) 1956 4982 2066 3998 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 26 1982 0 44 5026 0 6 2072 0 10 4008 15 1 Duct loads 39% 37% 772 1857 39% 37% 807 1481 Total room load 2754 6883 2880 88 54249 Air required(cfm) I I 158I 312I I I 165I Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. a -46- wrlghtso-� 2019-Apr-1016:17:42 • RightSuite® Universal 201919.0.01 RSU08101 Page ...Adams Homes -2020 Model- 5113 Birch Drive.rup Calc=MJ8 Front Door faces: E wrightsofr Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By- 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalo @aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Hall 0 ft 8.0 ft heat/cool 1.0 x 85.0 ft 85.0 fP —1 Ty Conshuc6on number U-value (Btuhlft- Or HTM (Btuh/ft2) Area (fe) or perimeter (ft) Load I (Btuh) Area I or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 11 Wl1� _LG Yy �L-----DG 13A-flocs - 4A5.2onn ._ _ , 13A-4ocs 4A5.2om 1100._ ,_ - ..._ 4A5-20 s- AA&tom „.^.. 13A-4om 4A5-tom 11D0 16B-30ad. _ __._ _ 22A-wl_ _._ _ _ _ "'- �343 —.0.770 0.143 0.770 0.390 ..Y., 0.14J ._._0'143 0.770 0.770 039 .0 --0.032 ____..0.989 b _n a a a s s_ w w w _ ,- . 21.56 4.00 21.56 10.92 ___ , 4 56 __2100 4.56 21.56 __ 10.92 _.:090 .. 27.69. 219 _, _19.31 2.19 45.10 10.34 1F6_ 9.31 r12.19 5.10 45.10 10.34 -._,11.60._ _. 0.00 — 0 . _ _0 0 0 0 _.._ 0 _. —..�0 0 0 _ 0 _85 . _ . _ _ 85 �—'- 0—`�`"—'U _ _ _ 0 0 0 0 __ 0 0.�._._ 0 0 0 __ 85 _ _ _ _ 0 , , _. ---0 0 0 0 _.0. 0 0 _ 0 ___.._76 _. 0 --'�-0 _ 0 0 0 - - _-_-_0 _.D. 0 0 —_0 _ 136 _ .-a ---- .Y_. ___- _ ..,. __ W V '-G C_-,_ F _ __, 6 c) AED excursion -8 Env elope loss/gain 76 128 12 a) In61trabon b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 Appliancestother 0 0 0 Subtotal (lines 6 to 13) 1 1 76 128 14 15 Less external load Less transfer Redistribution Subtotal Duct loads :3L91/379/6 0 0 -76 0 0 0 0 -128 0 0 Totl room load Air raequired (cfm) I I 0I I 0 001 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,� -rk- w� Igh�oTC 2019-Apr-1016:17:42 I&k RighlSuitel) Universal 201919.0.01 RSU08101 Page ...Adams Homes -2020 Model- 5113 Birch Drive.rup call; =MJ8 Front Door faces: E Duct System Summary Deb: * 'wrightsoft y ry Date: Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com i"'roject intormation For: Adams Homes -2010 Model 5113 Birch Drive, Fort Pierce, FL 34982 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.300 in/100ft 0.300 in/100ft Actual air flow 1383 cfm 1383 cfm Total effective length (TEL) 167 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (fit) Ftg.Egv Ln (ft) Trunk Bath h 710 41 14 0.393 5.0 Ox0 VIFx 12.3 115.0 st2 Bedroom h 3788 217 142 0.370 8.0 Ox0 VIFx 20.2 115.0 st2 Bedroom 3 h 2068 119 77 0.409 6.0 Ox 0 VIFx 7.3 115.0 st2 Dining Room c 1958 84 89 0.381 6.0 Ox 0 VIFx 16.1 115.0 st3 Foyer h 796 46 22 0.370 5.0 Ox0 VIFx 20.3 115.0 st3 Kitchen c 3441 79 156 0.356 8.0 OXO VIFx 25.6 115.0 st3 Kitchen -A c 3441 79 156 0.379 8.0 Ox0 VIFx 17.0 115.0 st3 Laundry c 1136 7 51 0.390 5.0 Ox0 VIFx 13.3 115.0 st2 Living Room c 2744 83 124 0.301 7.0 Ox0 VIFx 31.3 135.0 SW Living Room -A c 2744 83 124 0.317 7.0 Ox0 VIFx 22.9 135.0 st4 Master Bath h 2975 171 53 0.315 8.0 Ox0 VIFX 43.7 115.0 stl Master Bedroom h 2214 127 112 0.331 7.0 Ox0 VIFx 36.1 115.0 stl Master Bedroom -A h 2214 127 112 0,323 7.0 Ox0 VIFx 39.8 115.0 stl Study c 3090 83 140 0.300 7.0 Ox0 VIFx 31.8 135.0 st4 wicI h 668 38 10 0.316 5.0 Ox0 VIFx 43.2 115.0 st1 wlC2 c 62 2 3 0.332 4.0 Ox0 VIFx 1 35.6 115.0 SO Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk stl Peak AVF 465 289 0.315 592 12.0 0 x 0 VinlFlx st4 Peak AVF 248 388 0.300 495 12.0 0 x 0 VinlFlx st3 st3 Peak AVF 535 810 0.300 758 14.0 0 x 0 VinlFlx st2 Peak AVF 383 284 0.370 488 12.0 0 x 0 VinlFlx �F wrightrsofV 2019-Apr-1016:17:43 ....., ...�..... Right-Suite(g) Universal 201919.0.01 RSU08101 Page 1 /if+�i..AdamsHomes -2020 Model- 5113 Birch Ddve.mp Calc=MJB Front Door faces:E Name Grille Size (in) HJgClg (Cffm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox0 1383 1383 0 0 0 0 Ox 0 VIFx wrightSoft- 2019-Apr-10 16:17:43 ... 1 1a... RightSuite® Universal 201919.0.01 RSU08101 Paget ..Adams Homes -2020 Model- 5113 Birch Dnve.rup Cato =MJ8 Front Door faces:E