Loading...
HomeMy WebLinkAboutTRUSS PAGEa_ , Cl C7 U C1 U m m Q Q Q Ca to U o REVIEWED ❑ REVISE AND RESUBMIT ❑ REVIEWED WITH NOTATIONS ❑ NOT REVIEWED (SEE EXPLANATION) Corrections or comments made on equipment submittals or shop drawings during this review do not relieve con- tractor from compliance with requirements of the draw- ings and specifications. This check is only for review of general conformance with the design concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for confirming and correlating all quantities and diman- sions; selecting fabrication processes and techniques of construction; coordinating his work with that of all ether trades and performing his work in a safe and satisfactory manner FLORIDA DESIGN SOLU OHS,INC. Date K BY. •,y , Submittal Na Pmlett Na Project Faq. Project Dos 05 05 D03 Doi Doe VA. CLG Doi SO¢ClWemaYM PF�OJN�Nf�1BY�eYNd romwovu wawawRruu[es cmRem �>xn xcevwm Rna�o . eonouwvw vrc so.o Y'�XLY1Ono" 1°ap1 Retumea Before Fabrication w1I Begin. For Your Protection Check All Dimensions And Conditions Prior To Approval Of Plan. SIGNATURE BELOW INDICATES ALL ROOF LOADING _ FLOOR LOADING TOLL: 20 NOTES AND DIMENSIONS HAVE PSF TLLL: 40 PSF BEEN ACCEPTED. TCDL' OT PSF TCDL: 10 PSF BCDL: 10 PSF BCDL 5 PSF By Data TOTAL: 37 PSF TOTAL. 55 PSF DURATION: 1.25 DURATION: 1.00 CAUTIONM DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO TXE ENGINEERING DRAWINGS AND BSCIAI SUMMARY SHEETS ALL PERMANENT BRACING MUST BE W PLACE PRIOR TO LOADING TRUSSES Co. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE W PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE 2) BEARING BLOCK REQUIREMENTS 3) SCAB DETAILS (IF REQUIRED). _ A) UPLIFT AND GRAVITY REACTIONS. WARNING Backehargea will Not Be Accepted RegaMlesa of Fault Wa W Prier Notificatlbn By Customer Within a8 Hours And Investigation By Builtlers Fint Soursa. NO EXECPTIONS. The General Contractor Is ResponoWle For All Connectiom Other Than Tmas to Truss, Gable Shear Wall, And Connections. Te..... and P...et &acing. And Gigng And Root Diaphragm Connections. ROOFPITCH: $112 CEILING PITCH: 3112 TOP CHORD SHE: 2 X a BOTTOM CHORD SRE: 2 X♦ OVERHANG LENGTH: IV END CUT: Plumb LANNLEVER: — TRUSS SPACWG: W BUILDING CODE: MC2017 BEARING HEIGHT SCHEDULE SCANNED �Y 8t.. Lucie Coon BUMER: Adams Homes PROJECT: Single Family MODEL 2010 A 1 OX20 LANAI ADDRESS: 5113 BIRCH DR LOT I BLOCK: SUBDIVISION: I ESTATESIST LUCIE CRY: I FORT 01910 DRAWN BY: KTEIIBER JOB 9: 1731015 DATE: I04101D019 SCALE: I NTS PLAN DATE: 1 2019 REVISIONS: 1. 2 1. �, BuNers Fu JtSoulm "bill Airport Road Plant City, FL 33563 Ph. (813)305-1300 Fax (813) 305.1301