HomeMy WebLinkAboutBOATLIFT PAPERWORKENGINEERING REVIEW.• BOAT LIFT MOUNTING BRACKETS AND SPECIFIED MOUNTING HARDWARE COMPLY WITH WIND LOAD REQUIREMENTS OF THE 6TH EDITION (2017) FLORIDA BUILDING CODE, PER ASCE 7, AND PER DESIGN LOAD REQUIREMENTS OF THE 2015 EDITION ALUMINUM ASSQCIATION'S ALUMINUM DESIGN MANUAL. MOUNTING BRACKETS INSTALLED PER HI —TIDE INSTRUCTIONS, WILL EXCEED ULTIMATE DESIGN WIND SPEED OF 180 MPH (EXPOSURE CATEGORY C OR D) BOATS ARE TO BE REMOVED FROM BOAT LIFTS PRIOR TO A MAJOR WIND EVENT. PILINGS• PILING PENETRATION TO BE 10' INTO THE SAND BOTTOM OR 5' INTO ROCK STRATA, SUB -SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH FBC 201 Z ALL PILINGS TO BE 1 2" MINIMUM DIAMETER 2.5 C.C.A PRESSURE TREATED WOOD, PRE -STRESSED CONCRETE OR COMPARABLE EQUIVALENT. SEAWALL I THE CONTRACTOR SHALL VERIFY SEAWALL CAPACITIES TO -COMPLY W I T H F B C 2 0 1 7'. X2 FLEC7RICAL RENEW.• 2 HP ELECTRIC MOTOR -- AMPS ® 115V EACH 12.4 AMPS 0 230V EACH QUANTTY.• 2 TOTAL WATTS: 5704 RECEIVED AUG 15 2019 ST. Lucie County, Permitting t.Uc,1e l0 B0G SCANNED BY St. LudeCounfy NOTE TO EXAMINER: THIS CERTIFIED ENGINEERED DRAWING HAS BEEN PREPARED SPECIFICALLY FOR USE ONLY BY: °°°°OpO000000000 onnuuu °° (G VL M e 1 e°° 0 \ O E H 8 140.43855 iAUG 091019p STATE OF 1u �a '8 A•L 0 R I 0 O N A 1. �l� o000 ROGER SABER P.E. NO. 43855 MCR PROFESSIONAL ENGINEERING C.A. NO. 26967 1014 NW PINELAKE DR. STUART, FL 34994 PILING MOUNTING PM (2) 5/8- DIA THREADED illOUNT REQUIRED FOR MOUNTING :AWALL MOUNTING 5/8- DIA ANCHORS FOR MOUN77NG F20,000 LB. ALUMINUM ELEVATOR X2 M� BOATLIF7S AND MARINE PRODUCTS(2017 FBC) l n IaU�Q�IT 4050 SELW77 ROAD FORT PIERCE, FL 34981 HYDE SCALE.• NIS DATE- 112118 REV 1 1-800-544-0735 www.hi—tide.com