HomeMy WebLinkAboutCBUCK ENGINEERING PAPERWORKCBUCK Engineering Specialty Structural Englneerinq CBUCK, Inc. Certificate ofAuthorization #8064 Evaluation Report Mitten Vinyl Siding Panels Vinyl Siding Assembly Manufacturer: Mitten, Inc. 70 Curtis Avenue North Paris, Ontario N31- 3T2 Canada (800)265-0774 for Florida Product Approval # FL 13992.1 R1 Florida Building Code 2010 Per Rule 9N-3 Method: 1- D Category: Panel Walls Sub - Category: Siding SCOWL St. Luce BY Product: Mitten Vinyl Siding Panels Prepared by: James L. Buckner, P.E., S.E.C.B. Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 11-187-Siding -ER Date: 2 / 06 / 12 Contents: Evaluation Report Pages 1— 9 ame� uc ner, P.E., SECB Florida .E. # �11242 CBUCK, Inc. 1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403 Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net CBUCK Engineering FL #: FL 13992.1-R1 Date: 02 / 06 / 12 Report No.:11-187-Siding-ER Page 2 of 9 Specialttj Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Manufacturer: Product Name: Product Category: Mitten, Inc. Mitten Vinyl Siding Panels Panel Walls Product Sub -Category Siding Compliance Method: State Product Approval Rule 9N-3.005 (1) (d) Product/System Mitten Vinyl Siding Panels Description: Vinyl (PVC) Vinyl Siding Panels with a wood -grain texture appearance, concealed fasteners and an interlocking edge seam. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Siding Panel 2. Fasteners Support: Type 1: Wood Supports (Design of support system is outside the scope of this evaluation.) Type: Wood Studs Stud Size: 2" x (min. thickness) Dimensional Lumber Stud Spacing: 16" o.c. Type 2: Wood Structural Panel supported by wood studs (Design of support system Is outside the scope of this evaluation) Wood Structural Panel Description: • 7/16" (nominal) OSB (Oriented Strand Board), or • 15/32" (nominal) or greater Plywood Wood Stud Description: Stud Size:: 2" x (min. thickness) Dimensional Lumber Stud Spacing: 16" o.c. Performance: Wind Resistance: • Design Pressure: Refer toTable A (Refer to"Table A" attachment detals herein) FL M FL 13992.1-R1 Date: 02 / 06 / 12 Page Report No.: 3 of g7-Siding-ER CSUCK Engineering Speciaity Structural Engineertnq CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The product described herein has demonstrated compliance with: • ASTM D3679-05 — Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 2010, Section 1404.9. Standards Equivalency: The ASTM D3679-05 standard version used to test the evaluated product assembly is equivalent with the prescribed standards in ASTM D3679-06a adopted by the Florida Building Code 2010. Evaluation Report This product evaluation is limited to compliance with the structural requirements Scope: of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 9N-3.001. Limitations and • _Scope of "Limitations and Conditions of Use" for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 9N-3.005. Per Rule 9N-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval'. • Option for application outside "Limitations and Conditions of Use" Rule 9N-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Walls shall have a minimum water-resistant barrier equivalent to one layer of #15 asphalt felt complying with ASTM D 226, Type I in accordance with FBC 2010, Section 1404.2. • Design of support system is outside the scope of this report. Support shall be designed by others and shall comply with the FBC Chapter 23. • Fire Classification is outside the scope of Rule 9N-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of Siding panel products in accordance with the Florida Building Code and Rule 9N-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Architectural Testing, Inc. (FBC Organization M QUA 1844) FL M FL 13992.1-R1 Date: 02 / 06 / 12 CBUCK Engineering Report No.: 4 of 97-Siding-ER Speclalty Structural Englneerinc] CBUCK, Inc. Cert(flcate of Authorization #8064 Components/Materials Siding Panel: Mitten Vinyl Siding Panels (by Manufacturer): Profile/Dimensions: Refer to Table A & Profile Drawings Type: Solid, Perforated & Basketweave/Lanced Material: Vinyl Polyvinyl Chloride (PVC) Thickness: Refer to Table A Tensile Strength: 7,344 psi Standard: ASTM D 3679-05 Color: Painted, by manufacturer Fastener: FASTENER: Ring Shank Roofing Nail Type: Nail Length: 1-1/2" Size : Nail Shank Diameter: 1/8" Nail Head Diameter: 3/8" Corrosion Resistance: Per FBC Section 1506.5 Standard: Per ASTM F 1667 Installation: Installation Method: (Refer to Table "A" & Drawings on pages 5 — 9 of this report) Install "Mitten, Inc's Vinyl Siding Panels per the following: • Attach panels with fasteners per Table "A" • Supportspacing: PerTable"A" • Ensure panels are fully engaged along bottom length of panels, do not force up to tighten when fastening. Install Mitten Vinyl Siding Panels in compliance with the installation method listed in this report and applicable code sections of FBC 2010. The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. ASTM D3679-OS Test By Radco, Inc.(FBC Organization ID# TST 1987) Report #RAD-3853, Date: 5/11/09 Report #RAD-3578, Date: 5/11/09 Report #RAD-3550, Date: 5/11/09 Report #RAD-3499, Date: 5/11/09 2. Engineering Analysis By CBUCK Engineering 3. Quality Assurance Architectural Testing, Inc. (FBC Organization #QUA ID:1844) 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization #ANE 1916) FL ff: FL 13992.1-113 Date: 02 / 06 / 12 CBUCK Engineering Page5of9 rtNo.:7Siding-ER SpPCidity StrUC=tureil Enginel=rinq CBUCK, Inc. Certificate of Authorization #8064 Engineering Data Mitten, Inc. Vinyl Siding Panels Table "A" VINYL SIDING PANELS - DESIGN PRESSURES Model Configuration Thickness Exposure Support Stud & Fastener Design Pressure (PSF) (3.002") (x) Type Spacing (y) (max.) Positive Negative 1 4.5 Horizontal Double 4.5" 0.040" g" Wood 16" +18.9 -18.9 Oregon Pride Studs 2 4.5 Horizontal Double 0.040" g„ Sheathing 16" +52.4 -52.4 Oregon Pride w/Studs 3 Cabot D4 Double 4" 0.040" g' Wood 16" + 17.88 -17.88 Dutchlap Studs 4. Cabot D4 D Double 4" 0.040' 8" Sheathing 16" +50 -50 Dutchlap w/Studs S. D4 Horizontal Double4" 0.040" g„ Wood 16" +24.5 -24.5 Oregon Pride Studs 6' D4 Horizontal Double4" 0.040" 8" Sheathing 16" +68.1 - 68.1 Oregon Pride w/Studs 7. D4.5 Cove Double 4.5" 0.040" 91, Sheathing 16" + 16.3 -16.3 w/Studs 8. D4.5 Cove Double 4.5" 0.040" g', Sheathing 16" +45.27 - 45.27 w/Studs D4.5.Dutchlap -Sentry-� � _ r ' o61e 4;5� „_ _ 9 Sheathing Studs_ t= - _--+39.9_ -7.9d9;t 10. DS Cove Double 5" 0.040" 10" Wood 26" + 27.3 - 27.3 Studs 11. DSCove Doubles" 0.040" 10" Sheathing w/Studs 16" +75.7 -75.7 12. Sentry D4 Double4" 0.044" 8" Sheathing 16" +89.9 89.9 Horizontal w/Studs 13. D4 Dutchlap Double 4.5" 0.040" g" Wood 16" + 17.88 -17.88 Oregon Pride Studs D4 Dutchlap Sheathing 14. Oregon Pride Double 0.040' 9' w/Studs 16 „ +50 -50 15. DS Sentry Doubles" 0.044" 10" Wood 16" +22.8 -22.8 Dutchlap Studs 16. D5 Sentry Doubles" 0,044" 10" Sheathing 16" + 63.3 63.3 Dutchlap w/Studs 17. DSVertical Doubles" 0.040" 10" Sheathing 16" +45 -45 w/Studs 18 D6 Horizontal Double 6" 0.050" 12" Sheathing 16" +30.3 - 30.3 Insul lank w/Studs D6 Horizontal D-ouble 6'r 0.050" 12" eat ing 16" +84.3 - 84.3 Insulplank w/Studs Notes: Negative Pressure: Outward Positive Pressure: Inward FL #: FL 13992.1-113 Date: 02 / 06 / 12 Page No.: 6 of 97 Siding -ER C®UCK Engtnserinq SpeclaltLj Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 D4.5 Horizontal DS Cove D4 Installation Method Mitten, Inc. Vinyl Siding Panels PROFILE DRAWINGS D4 Horizontal D4.5 Cove D4 Dutchlap D5 Vertical i IDS Dutchlap 136 Horizontal TYPICAL PANEL PROFILES \ FL k: FL 13992.1-111 y Date: 02 / 06 / 12 \ C®UCK Engineering Pagert No.:; of97-Siding-ER SpPctaltLj Structural E_nc2Ineerinq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Mitten, Inc. Vinyl Siding Panels Barrier 2" Wood Studs By Others 16" o.c. m . INTERIOR 1/2" min. Sheathing By Others Siding Panel Ring Shank Nail EXTERIOR t)qm ire (x) TYPICAL SECTION AT SUPPORT VINYL SIDING PANEL ATTACHED TO WOOD SUPPORTS WITH SHEATHING ASSEMBLY SIDE VIEW CBUCK Engineering Specialty Structural Engineering Ring Shank Note: Fast oxmWed Intedoddn E Installation Method Mitten, Inc. Vinyl Siding Panels FL #: FL 13992.1-R1 Date: 02 / 06 / 12 Report No.:11-187-Siding-ER Page 8 of 9 CBUCK, Inc. Certificate of Authorization #8064 Vinyl Siding Panel TYPICAL ASSEMBLY PLAN VIEW VINYL SIDING PANEL ATTACHED TO WOOD SUPPORTS FL #: FL 13992.1-111 9 of 9 Date: 02 / 06 / 12 C®UCK Engineerinc� Report No.: -Siding-ER Page 9 of 9 Sp2claltLJ Structural EnglnPPrinq , CBUCK, Inc. certificate of Authorization #80r,4 Installation Method Mitten, Inc. Vinyl Siding Panels Ring Shank Note: Nails are In the mtedocid Panel TYPICAL ASSEMBLY PLAN VIEW VINYL SIDING PANEL ATTACHED TO WOOD SUPPORTS WITH SHEATHING