Loading...
HomeMy WebLinkAboutNOAMIAMFDADE Em BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION M OF ACCEPTANCE I James Hardie Building Product, 10901 Elm Avenue Fontana, CA 92337 MIAMI-DARE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 www.miamidade.eov BY St. Lucie l ®Unty SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Artisan Lap Siding APPROVAL DOCUMENT: Drawing No. 2008-8-7.vsd, titled" Artisan Lap Siding ", sheets 1 through 4 of 4, prepared by Ronald I.Ogawa, P.E., dated August 07, 2008, last revision #1 dated August 27, 2008, signed and sealed by Ronald I. Ogawa, P.E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and the approval date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any. section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1, evidence submitted page E-1 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E., M.S. /J NOA No. 08-02/2013 MIAMI�DpDE COUNTY Jj Expiration Date: 10/02/2013 008 2/wag Page Approval Date:10/Ol James Hardie Building Product Inc NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 2008-8-7.vsd, titled " Artisan Lap Siding ", sheets 1 through 4 of 4, prepared by Ronald I. Ogawa, P.E., dated August 07, 2008, last revision 41 dated August 27, 2008, signed and sealed by Ronald I. Ogawa, P.E. B. TESTS 1. Test Report 9MID3137643-01, by Intertek ETL Semko, dated January 30, 2008, per TAS 202 and TAS 203, signed and sealed by Rick Curkeet, P.E. 2. Test Report #MID3137643-03, by Intertek ETL Semko, dated April 16, 2008, per TAS 202 and TAS 203, signed and sealed by Rick Curkeet, P.E. 3. Test Report 43097158-009B, by Intertek ETL Semko, dated May 04, 2007, per Acceptance Criteria for Fiber Cement Siding used as Exterior Wall Siding, signed and sealed by Kai Kooner, EIT. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. Test Report 93099611SAT--001, by Intertek ETL Semko, dated June 28, 2006, per ASTME84-05, Surface Burning Characteristics of Building Materials, signed by C. Anthony Penaloza, Flammability Testing Team Leader. Hgfrify A. Makar, P.E., M.S. Product Control Examiner NOA No. 08-0514.11 Expiration Date: 10/02/2013 Approval Date: 10/02/2008 E-1 omu spacing at is- o.D. -� DETAIL S/e"miok/5ply PR D c DESCRIPTION B �--- will I111111 /, I /p, A APA rated plywood Artisan® Lap Siding material is a v1 Noto:Cmwaledplamfms mmse OSBM9-e rmtshownmrdety T- sheathing nonasbestos fiber -cement product tested `�____; '..:: -__.t ._ __ �________________________ _-__--. mechan in accordance with ASTM C1186 Grade 11, fastened to wood Type A and meeting the requirements of studs the Florida Building Code. Weatherproofing per PLANK DIMENSIONS 2121.s.2 of FloritlaWidth Length Thickness WALL -j.ArE .••. �• •Buldi g Code 5 8-'/." 12' 5/B"MIGHT I i i dlegs, Istarterstrip Nominal 2"X RAmIlUr a.F• �� 6'Metal C-stud.titer' ationRESSDREDesign Pressure AL Ariisarr®Le Sidi p ngIt.Impact Wood Studs -92 psf Resistant t-'/." feu X 5/e^ thinkPlanks Installed over 518" thick / 5 ply APA !________—_—L._______-__-!__.----____._,_____--___u-------------s--____._ rated plywood sheathing 5/a^ thick/ 5 ply APA rated plywood sheathing shall DFTAIL be attached to the studs In accordance with the — Florida Building Code, with Minimum 98 X 1" long ribbed bugle head screws, spaced a maximum or 9 Inches on center along the perimeter and a maximum of 12 inches on center along the �\ Intermediate supports.. \ Theexposed fastener shall bee Mnimum "\0.075° shank X 2' long corrosion resistant metal stud finish nail (pin) over metal studs. The exi, fastener sha0 be placed In the `r)-' 303LIV �7 { IaLve •oN The concealed fastener shall be a minimum No. e-18, 0.375 head diameter X 1-/.' long' r bugle head screw over metal studs. The concealed fastener shall be fastened • through the tap edge of a single plank; the r concealed fastener shall be positioned V down from the plank's top edge in such away that the Fastener is fully concealed by the next / coursaofpiank. j *or screw shall have at least 3 MI threads penetrating metal taming AdLs rnO Lap Siding L Weatherproofing per 2121.6.2 of Florida Building Code 5/11" thick / 5 ply APA rated plf weed sheathing fastened according to the Florida Building Cade 1890, Nominal 2" X 6" Metal C-stud IC- ARTISAN® LAP SIDING IN516L ATIDN DETAILS • All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sect... of the Florida Building Code. • Metal studs where Artisan® Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. • Planks shall be applied horimntaly commencing from the bottom course of the wall with 1-'/.'vride laps at the top of the plank. • The lounge and groove vertical joints must occur 4" off stud, do not nail within 2 inches of tongue and groove. • The planks shall be Installed over 518"thick / 5 ply APA rated plywood sheathing supported by a minimum of 18ga, Nominal 2• X 6" Metal C-studs spaced a maximum of 16" O.C. • The siding shall be fastened over the studs with a combination of both concealed and exposed fasteners. • The concealed fastener shall be a minimum No. 848, 0.375' head diameter X 1-'/.' long* bugle head screw over metal studs. ('or screw shall have at least 3 full threads penetrating metal framing) • The exposed fastener shall be a minimum 0.075" shank X 2' long corrosion resistant metal stud finish nail (pin) over metal shads. • The concealed fastener shall be fastened through the top edge of a single plank; the concealed fastener shall be positioned 1" down from the plank's top edge In such a way that the fastener is fully concealed by the next course of plank. The exposed fastener shall be placed in the overlapping area approximately W from the bottom edge of the overlapping plank. Both concealed and exposed fasteners shall be 5 7" O.C. vertically and 16" O.C. horizontally Into metal studs through 518" thick / 5 ply APA rated plywood sheathing. A fastener edge distance of/.' shall always be observed. 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to the studs in accordance with the Florida Building Code, with minimum #8 X 1" long ribbed bugle head screws spaced a maximum of 6 inches on center along the perimeter and a maximum of 12 inches on center alone the infermediafa .,,m. rk Artisan® Lap Siding (Metal Studs) This drawing and the copyright therein are the property of the named company and accordingly the drawing must not be copied or reproduced in any material form whatsoever and must be returned with quotation and on completion of job m..ovsacm,wmvzrmw—J A I Mlaml Dade NOA-Arhsan Lap Siring-2000e-l.vad Creator. C. Dierck5 SCALE 1/2" = 1'-0" Date: Br7/2008 SHEET 1 OF 4 FRAMING • NOMINAL 18 GAUGE 2" X 6" STEEL STUDS 16' O.C. FASTENED WITH NO. 8 X 1" LONG BUGLE HEAD SCREWS (2 PER TOP AND BOTTOM CONNECTION) SHEATHING • NOMINAL 5I8'THICK 15 PLY APA RATED PLYWOOD SHEATHING • FASTENED WITH #8 X 1" LONG RIBBED BUGLE HEAD SCREWS, AT 6" O.C. AROUND THE PERIMETER AND 12" O.C. WITHIN THE FIELD CLADDING • PLANKS OVERLAP 1 %" • THE EXPOSURE IS 7" • THE PLANKS ARE BLIND SCREWED WITH NO.8-18, 0.375" HEAD DIAMETER X 131: LONG CORROSION RESISTANT BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACE SCREWS 1' DOWN FROM THE TOP EDGE OF THE PLANK AT EACH STUD LOCATION • THE PLANKS ARE FACE NAILED WITH 0.075" SHANK DIAMETER 2' LONG CORROSION RESISTANT METAL STUD FINISH NAILS, PLACE FINISH NAILS 'Y.' UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION FOR METALAND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) Cladding Framing Sheathing L^LAY rgrEo �= / ORI '','*T1VAL O I . V'l v Artisan@ Lap Siding (Metal Studs) This dmWng and the copyright therein are the property of the named company and "up accordingly the drawing must not be copied or reproduced in any material form whatsoever and must be returned w8h quotation and on completion of )ob J"...xw Rm vnm . w. ®.smmn"•oc+nmu SIZE A FSCM NO DwG NO MiaM Daa•NOA •ANssnLap ai?eg200a8].vea REV 1 Creator. C. Dlercks SCALE 1' =1•-0" Date: 6 M08 SHEEr 2 0F4 Stud Spacing at 16' O.C. WALLLENGT B F-� i f4�j Note: Corceabd ask fasts. e,0 osa raskoners ml'M nor duly uALL TIGHT i ��••fi .� ` II '�i4 i i.i i }v�/ • M •... ..., , i i i i.i �� Q ___--- i------------- L ------------- ..:.-------- .___i. B 3/4' Minimum Edge Distance '�1�"-- '�N— �I Halls et 76' O.D. (typ.) 314°Minimum Edge Disfan--►II. SW MIdk/ 5 PN APA rated Plywood sheathing shag DETAILA be attached to the studs in accordance with the Florida Building Code, With minhnum ad 2-3r8" long nails spaced a maximum of 6 inches on carder / along the perimeter and a MaXimum of 12 inches on `� ranter along the intermediate supports. \" The exposed fastener shagbeanad, 2- // - W long corrosion resistant finish ran Over Wood studs. / The "Posed fastener shag be placed in n the overlapping area approximately ale r from the bottom edge of the overlapping plank The concealed fastener shall be an 8d, 2.3W long corrosion resistant ring shank box nail over wood erode. The concealed fastener shag be fastened through the by edge of a single plank the concealed fastener shag be positioned 1- down from this PLOWS top edge in such a way that the fastener is"concealed by the next course or plank Anisan® tap Siding Weathefprcofing per 2121.6.2 of Florida Building Code 5/8" thick/ 5 ply APA rated pywoad sheathing fastened avnrdng to the Florida Building Cale 2' X 4• S-P-F Wood Studs SEE 518"thick /5 ply DETAIL A APA rated plywood T sheathing r maobantcegy fastened to wood ,I studs Weetherproo8tg per 2121.6.2 of Florida Building Coda 2' X 4° S-P-F Wood Studs Adisar(S) Lap Siding 1-'/.'taO X 5/8' thick starter strip SECTION B-B PRODUCT DESCRIPTION Artisan® Lap Siding material Is a nonasbestos fiber -cement product tested In accordance with ASTM C1186 Grade 11, Type A and meeting the requirements of the Florida Building Code. PLANK D_ IMEN—S ON55 Width Length Thickness 5 8-'/.' 12' 518• DESIGN PRESSURE RATING Installation Design Pressure Wood Studs -92 Pat Impact Resistant — Planks installed over 5/8• thick / 5 ply APA i rated plywood sheathing ARTISAN® LAP SIDING IN TAI LATIDN DETAILS • All Installation shall be done in conformance with this Notice of Acceptance, the manufacturer's inshallation recommendations, and the applicable sections of the Florida Building Code. • Wood studs where Artisano Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.OA • Planks shall be applied horizontally commencing from the bottom course of the wall with 1-W wide Zaps at the top of the plank. • The tongue and groove vertical joints most ocolrr 4" off stud, do not nail within 2 inches of tongue and gmave. The planks shall be installed over 5/8" thick 15 ply APA rated plywood sheathing supported by a minimum of 2"X4° S-P-F wood studs spaced a maximum of 16" O.C. • The siding shall be fastened over the studs with a combination of both concealed and exposed fasteners. • The concealed fastener shag bean ad, 2J/8" long corrosion resistant ring shank box nail over wood stutls. • The exposed fastener shall be an ad. 2-'h' long corrosion resistant finish nail over wood sNtls. • The concealed fastener shall be fastened through the top edge of a single plank the odcorstuds. fastener shall be positioned 1" down from the plank's top edge in such a way that the fastener is fogy concealed by the next course of plank • The exposed fastener shall be placed In the overlapping area approximately from the bottom edge of the overlapping plank. • Both concealed and exposed fasteners shag be 5 7" O.C. vertically and 16" O.C. hcrox ntally into wood studs through 618" thick / 5 ply APA rated plywood sheathing. • A fastener edge distance of always be observed. • 5/8" thick 15 ply APA rated plywood sheathing shag be attached to the studs in accordance with the Florida Building Code, with minimum 8d 2-W8' long box nails spaced a maximum of 6Inkhes on center along the pertmeterand a maximum of 12 inches on center along the intermediate support. Creator: C. Dlemks ANisaro Lap Siding (Wood Studs) This drawing and the copyright therein are the property of the named company and accordingly the drawing must not be copied or reproduced In any material form whatsoever and must be returned with quotation and on completion of job A I I Wain Dade NOA-Alban lap Siding20a 7.vsd 112" =1'-0" i Date: BR/2og8 3 OF 6.00in. ta- �-16.001n.—►I i I -------------------------------- ----------------------------•12.001n. n. `\\�� ,.. _ 21 I. = k - ST (y c ,, •.!2OR10 �� O � I •//I//lllll III1111\\\\\Vj 1' V 4b FRAMIN-Q • NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED WITH 16d COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) SHEATHING • NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD SHEATHING • FASTENED WITH 2.3f8 INCH 8d COMMON NAILS, AT 6" O.C. AROUND THE PERIMETER AND 12" O.C. WITHIN THE FIELD CLADDING • PLANKS OVERLAP 1-Y" • THE EXPOSURE IS 7" • THE PLANKS ARE BLIND NAILED WITH A 2-3/8" CORROSION RESISTANT COMMON RING SHANK NAILS, 1" DOWN FROM THE TOP EDGE OF THE PLANK AT EACH STUD LOCATION • THE PLANKS ARE FACE NAILED WITH 2 W CORROSION RESISTANT FINISH NAILS,'V.." UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) Artisan(D Lop Siding (Wood Studs) / Cladding / Framing / Sheathing This drawing and the copyright thereln are the property of the named company and accordingly the drawing must not be copied or reproduced In any material form whatsoever and must be returned with quotation and on completion of job SIZE I FSCM NO I DwO NO RE A I MIaM Oad. NOA-Artisan Lap SI0No- 200 87Md Creator. C. Diercks SCALE 1"= 11-0. Data: Bf712008 SHEET 4 OF 4