Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 600A-2004R EnergyGauge® 4.5.2 -FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Wisner Residence Builder. Address: Lot 729 Nettles Island Permitting Office: St. Lucie County City, State: Ft. Pierce, FL Permit Number. Owner- - Jurisdiction Number: Climate Zone: Central 1. New construction or existing New 2. Single family or multi -family Single family _ 3. Number of units, if multi -family I 4. Number of Bedrooms 3 5. Is this a worst case? No 6. Conditioned floor area (112) 1987 ft2 _ 7. Glass typel and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 70(Sngle Default) 221.8 ft' _ b. SHGC: (or Clear or Tint DEFAULT) 7b. (Tint) 176.8 fit' _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 158.0(p) ft _ b. N/A _ c. N/A _ 9. Wall types a. Concrete, lnt hvsul, Exterior R=5.0, 2034.8 ft b. Frame, Wood, Adjacent R=11.0, 321.4 112 _ c. NIA _ d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=21.0, 1020.0 ft2 b. N/A _ c. N/A _ 11. Ducts _ a. Sup: Unc. Ret: Unc. AH: Garage Sup. R=6.0, 250.0 It b. N/A 12. Cooling systems a. Central Unit SCANNED b. N/A ®Y St. Lucie c nlntt, c. N/A 13. Heating system a. Electric Heat Pump b. N/A c. NIA 14. Hot water systems a. Electric Resistance b. NIA c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.11 Total as -built points: 22484 PASS r n Total base points: 24271 I hereby certify that the plartj nd-so-cifiraVris covered by this calculation are in compliance with the Florida Energy Code. d PREPARED BY: r&10hgT1d6 17P06-! Cpl°IS DATE: 3it9��9 I hereby certify that this buil 1 g, as designed, is in compliance with the Florida Energy Co Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. OWNERIAGENT: BUILDING OFFICIAL: _ DATE: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCPB v4.5.2) ;jjk Cap: 42.0 kBtu/hr _ SEER: 14.00 Cap: 40.5 kBtuhu _ HSPF: 8.30 Cap: 50.0 gallons _ EF: 0.95 _ MZ-C' PT' - y TNERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 87.3 The higher the score, the more efficient the home. , Lot 729 Nettles Island, Ft. Pierce, FL, L New construction or existing New _ 2. Single family or mull -family Single family _ 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 3 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ft') 1987 R' _ 7. Glass typel and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description .Area (or Single or Double DEFAULT) 7a(Sngle Default) 221.8 ft' b. SHGC: (or Clear or Tint DEFAULT) 7b. (Tint) 176.8 ft' _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 158.0(p) ft _ b. N/A _ c. N/A _ 9. Wall types a. Concrete, Int Insul, Exterior R=5.0, 2034.8 ft' _ b. Frame, Wood, Adjacent R=I1.0, 321.4 ft' _ c. N/A _ d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=21.0, 1020.0 ft' _ b. N/A _ c. N/A _ 11. Ducts a. Sup: Unc. Ret: Unc. AH: Garage Sup. R=6.0, 250.0 ft _ b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, BF -Whole house fan, PT -Programmable Thermostat, M&C-Multizone cooling, M2rH-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the ove energy saving features which will be installed (or exceeded) in this home before fma ' pection. ( erwise, a new EPL Display Card will be completed based on installed Co mpliant fie es. Builder Signature: 'N9. Date: Address of New t City/FL Zip: Cap: 42.0 kBtm/hr _ SEER:14.00 _ Cap: 40.5 kBtu/br _ HSPF: 8.30 Cap: 50.0 gallons _ EF: 0.95 M71C, PT, - *NOTE.- The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86 for a US EPADOE Enerv&ar'mdesignation), your home may qualify for energy efflciency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsea ucf edu for information and a list of certified Raters. For information about Florida's Energy Efciency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on ages 2&.4. EnergyGauge® (Version: FLKCP� v4.5.2) kin Summary Energy Code Results Residential Whole Building Performance Method A Project Title: Code Only Lot 729 Nettles Island Wisner Residence Professional. Version Ft. Pierce, FL Climate: Central 3/1912008 Building Loads Base As -Built Summer: 38517 points Summer: 37066 points Winter: 7893 points Winter: 10546 points Hot Water: 6790 points Hot Water: 6790 points Total: 53200 points Total: 54401 points Energy Use Base As -Built Cooling: 12518 points Cooling: 10185 points Heating: 4373 points Heating: 5152 points Hot Water: 7380 points Hot Water: 7147 points Total: 24271 points Total: 22484 points PASS e-Ratio: 0.93 EnergyGauge®(Version: FLRCPB v4.5) FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT#: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points 12.Single, Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 1997.0 24.35 8709.0 1.Single, Clear N 8.0 6.0 15.0 3DA9 0.68 309.0 Tint N 8.0 6.0 6.0 24.46 0.68 100.0 3.Single, Tint W 1.0 7.0 7.0 47.90 0.98 329.0 4.Single, Tint NW 1.0 7.0 • 7.0 33.43 0.99 230.0 5.Single, Tint NE 1.0 7.0 7.0 38.88 0.99 268.0 6.Single, Tint N 1.0 5.0 30.0 24.46 0.96 705.0 7.Single, Tint E 1.0 5.0 45.0 53.27 0.95 2278.0 S.Single, Tint W 1.0 3.0 9.0 47.90 0.86 369.0 9.Single, Tint E 1.0 7.0 7.0 53.27 0.98 366.0 110.8ingle, Clear NW 1.0 6.0 30.0 40.72 0.97 1186.0 11.8ingle, Tint W 1.0 5.0 30.0 47.90 0.95 1364.0 12.Single, Tint N 1.0 3.0 6.9 24.46 0.90 152.0 13.Single, Tint S 1.0 5.0 15.0 39.84 0.92 547.0 14.8ingle, Tint E 1.0 3.0 6.9 53.27 0.86 315.0 As -Built Total: 221.8 8518.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 321A 0.70 225.0 1. Concrete, Int Insul, Extedor 5.0 2034.8 1.00 2034.6 Exterior 2034.8 1.90 3868.1 2. Frame, Wood, Adjacent 11.0 321.4 0.70 225.0 Base Total: 2356.2 4091.1 As -Built Total: 2356.2 2269.8 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.0 1.60 33.6 1.Exterior Wood 21.0 7.20 151.2 Exterior 21.0 4.80 100.E 2.Adjacent Wood 21.0 2.40 50.4 Base Total: 42.0 134.4 As -Built Total: 47-0 201.6 CEILING TYPES Area X BSPM = Points Type R Value Area X SPM X SCM = Points UnderAttic 1020.0 2.13 2172.6 1. Under Attic 21.0 1020.0 2.64 X 1.00 2692.8 Base Total: 1020.0 2172.6 As -Built Total: 1020.0 2692.8 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 158.0(p) -31.8 5024.4 1. Slab -On -Grade Edge Insulation 0.0 158.0(p -31.90 5040.2 Raised 0.0 0.00 0.0 Base Total: -6024A I As -Built Total: 158.0 504D.2 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®IFlaRES2004R FLRCPB W.5.2 1. ♦ 1.0 FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT #: BASE AS -BUILT INFILTRATION Area X BSPM = Points Area X SPM = Points 1987.0 14.31 28434.0 1987.0 14.31 28434.0 Summer Base Points: 38516.7 Summer As -Built Points: 37066.0 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) lays 1: Central Unit 42000bbih ,SEER/EFF(14.0) Ducts:Unc(S),Unc(R),Gar(AH),R6.00NS) 37066 1.00 (1.09 x 1.150 x 1.00) 0.244 0.902 10185.4 38516.7 0.3250 12517.9 37066.0 1.00 1.250 0.244 0.902 10185.4 EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FIaRES'200411 FLRCPB v4.5.2 I FORM 60OA-2004R EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT #: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points 12.Single, Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 1997.0 9.11 3258.0 1.Single, Clear N a.0 8.0 15.0 15.07 0.99 223.0 Tint N 8.0 6.0 6.0 15.38 0.99 91.0 Mingle, Tint W 1.0 7.0 7.0 13.80 1.00 96.0 4.Single, Tint NW 1.0 7.0 7.0 15.30 1.00 106.0 5.8ingle, Tint NE 1.0 7.0 7.0 15.07 1.00 105.0 6.Single, Tint N 1.0 5.0 30.0 15.38 1.00 460.0 7.Single, Tint E 1.0 5.0 45.0 13.04 1.01 593.0 8.Single, Tint W 1.0 3.0 9.0 13.80 1.02 126.0 9.Single, Tint E 1.0 7.0 7.0 13.04 1.01 91.0 10.Single, Clear NW 1.0 6.0 30.0 14.97 1.00 448.0 11.Single, Tint W 1.0 5.0 30.0 13.80 1.01 416.0 12.Single, Tint N 1.0 3.0 6.9 15.38 1.00 105.0 13.Single, Tint S 1.0 5.0 15.0 10.88 1.02 166.0 14.5ingle, Tint E 1.0 3.0 6.9 13.04 1.03 92.0 As -Built Total: 221.8 3118.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 321A 1.80 578.5 1. Concrete, Int Insul, Exterior 5.0 2034.8 2.90 5900.9 Exterior 2034.8 2.00 4069.6 2. Frame, Wood, Adjacent 11.0 321A 1.80 578.5 Base Total: 2356.2 4648.1 As-BuikTotal: 2366.2 6479.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.0 4.00 84.0 1.Extedor Wood 21.0 7.60 159.6 Exterior 21.0 5.10 107.1 2Adjacent Wood 21.0 5.90 123.9 Base Total: 42.0 191.1 As -Built Total: 42.0 283.5 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under AtBc 1020.0 0.64 652.8 1. Under Attic 21.0 1020.0 0.81 X 1.00 826.2 Base Total: 1020.0 652.8 As -Built Total: 1020.0 826.2 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 158.0(p) -1.9 -300.2 1. Slab -On -Grade Edge Insulation 0.0 158.0(p 2.50 395.0 Raised o.o 0.00 0.0 Base Total: -3DD.2 As -Built Total: 158.0 395.0 EnergyGaugeO DCA Form 60OA-2004R EnergyGauge40/FlaRES'2004R FLRCPB v4.5.2 0 ---- -- --- - IT FORM 60OA-2004R 1L- EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT* BASE AS -BUILT INFILTRATION Area X BWPM = Points Area X WPM = Points 1987.0 -0.28 -556.4 1987.0 -0.28 -556.4 Winter Base Points: 7893.5 Winter As -Built Points: 10546.8 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 40500 btuh ,EFF(8.3) Ducts:Unc(S),Unc(R),Gar(AH),R6.0 10545.8 1.000 (1.078 x 1.160 x 1.00) 0.411 0.950 5151.5 7893.5 0.5540 4373.0 10545.8 1.00 1.250 0.411 0.950 5161.6 EnergyGaugeTM DCA Form 60DA-20UR EnergyGauge®IFIaRES'20D4R FLRCPB v4.5.2 ._\,,. /yy�..: d (\ \\)\/ ( _ zz.yi � } �§�. } � ' ,�� . . } }, \ '{ � � `{ \ . }\\`� � �� ��. � } } \ iy �}`® ; �\/:)\\\).� ( � ;§. �3! ; ..5 e / ; � v�{� : � ; . ��} -� 23)/� / � : :z; . � �}.>^)\} 1 � i�'>}}j.!&� ' � } �\&T|•:.: � �~ §(`f !\� � ` !� _ � � ._� � (� � ; § �� ! \ � : ( ( } � \\}\ /{zP ! " ` : ` ):( i } � \ \�( ` ( })�\�} � ! . i/i 2\!\� }:{\? ,. `� , � � {� �;z {- � ! � , , ` ;\ ; � . � .�1�� ! < ��!\� } � 1\� /` ��)_��: ��./d } } 2 \ � 2 (:� � \ d \2 � � FORM 60OA-2004R EnergyGauge® 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = , Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 50.0 0.95 3 1.00 2382.32 1.00 7146.9 As -Built Total: 7146.9 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Hot Water = Total Points Points Points Points Cooling + Heating + Hot Water = Total Points Points Points Points 12618 4373 7380 24271 10185 5152 7147 22484 PASS EnergyGauge" DCA Form 600A-2004R EnergyGauge4D/FIaRES'2004R FLRCPB V4.5.2 -7 ;t- -,-- I FORM 60OA-2004R EnergyGauge® 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1 ABCA.1 Maximum:.3 cfrm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Wells 606.1 ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiftmtion barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.tABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss orjoint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimcter, penetrations and scams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 12" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or Cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All duds, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducal in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTM DCA Forth 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCPB v4.5.2 Ll n 1' Wismer Residence HVAC Load Calculations for Wismer Lot 729 Nettles Island Port St. Lucie, Florida kL - VAC HVACRzsxDH'rt VAC LOADD S SCANNED StlucieCnunb/ Prepared By: Residential Energy Calds Wednesday, March 19, 2008 Project Report Designed By: Robert Fullan Project Date: Thursday, February 14, 2008 Client Name: Wismar Client Address: Lot 729 Nettles Island Client City: Port St. Lucie, Florida Company Name: Residential Energy Calc's Design Data _ Reference City: Fort Pierce, Florida Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor. 0.999 Elevation Sensible Adj. Factor. 1.000 Elevation Total Adj. Factor. 1.000 Elevation Heating Adj. Factor. 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter. 42 0 30 72 3 Summer. 90 78 50 75 61 Square ft of Room Area: 1,987 Volume (ft') of Cond. Space: 18,711 Square ft. Per Ton: 636 Air Turnover Rate (per hour): 3.9 Building Loads Total Heating Required With Outside Air. 37,462 Btuh 37.462 MBH Total Sensible Gain: 28,113 Btuh 77 % Total Latent Gain: 8,254 Btuh 23 % Total Cooling Required With Outside Air. 36,367 Btuh 3.03 Tons (Based On Sensible + Latent) 3.12 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Wismer Residence Port Saint Lucie FL 34983 Pa e 3 Miscellaneous Report System 1 Carrier Or Equivalent Outdoor Outdoors Indoor Indoor Grains Input Data Dry Bulb Wet Bulb R_ el.Hum Dry Bulb Difference Winter. 42 0 30 72 3.44 Summer: 90 78 50 75 61.09 Duct Sizin In uts Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor. 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./l00 ft. 0.1000 in.wg./l00 ft. Minimum Velocity. 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data _ Winter Summer Infiltration: 0.260 AC/hr 0.140 AC/hr Above Grade Volume: X 18,711 Cu.ft. X 18,711 Cu.ft. 4,865 Cu.ft./hr 2,620 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 81 CFM 44 CFM Total Building Ventilation: 69 CFM 69 CFM —System 1— Infiltration & Ventilation Sensible Gain Multiplier. 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier. 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) Duct Load FactorScenarios fors stem 1 Attic Duct Duct Surface From No. Type Description Location Ceiling Leakage Insulation _ Area MDD 1 Supply Main Attic 16B 0.12 6 536 No 1 Return Main Attic 16B 0.24 6 99 No ILL I�I� -�I�I I10 9DIV 9,llr f, 'N I''01� 4C'? 4IY PIY'^1'410ED w1b;3ml G N mlNCO �'�'Vll�, d C'N I�j fij ��O N C I m e I=15ia N'N �. d m I$iRla IgI I= I DIET, ^ Io.l N'oIm Flo I'Ig o'�'� 'I'1 51 3 W WI9I O I N glal IG i ,o I I I l i l i i l l I I I I I l ! I I I I l � III11II ,II III I i it ' i I I I I I - -L —1 J—I_ i A A L Lppa I yy IN I I I I'I Q IWN i f0 V_ I I(O _W I_A_LA ALN I^0_�IAOOoV--�VL AW IN,W A,;IV AI _V V It_Wif iOWiy�IwiN__t_NJ1A �O I_�_IfWjl'�_IVII�I_A W;VVi —II_V W�W m 'N IO W V NI IO AW W OO iV I�� V N N O11m �W6O Ntr tO �m'O Vt L�N IOoyW Ia'A I I I I ! i-m+'.mi �W I�I�I��IN -A+IOVo IN NI�I�OIV_!W ��I�L�IOJjJ I I �I�IWj I�^�, 'NI I+IW IO N �fWil :...1V 1W IW A Ipp 10I tpI�IW,W tfOIW I ItT IIfI��T1��, ro'W VLGWO W JI(WO �W 'N VIJ Nl�py�IA —L _� T-4—.--i—I•--�-- I 1 i I fTIOIUI m O AIm;- IN IN I Mimi. Of IV IONoIV 1_IV I`V I 1 NI+ + N W10• NWr ND TIC OII A IN W V_I W_ t0 W_ N i N i �ili �ilii�'lilil�lilil',i 3 vac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Wismer Residence Part Saint Lucie FL 34983 Pa e,6 Total Bugqft Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 10A-f: Glazing -French door, single pane clear glass, 45 945 0 1,550 1,550 insulated fiberglass frame, u-value 0.7 1A-hm-o: Glazing -Single pane, operable window, heat- 15 571 0 704 704 absorbing, metal frame no break, u-value 1.27 IA-hb-o: Glazing -Single pane, operable window, heat- 161.8 5.244 0 7,862 7,862 absorbing, metal frame with break, u-value 1.08 11 D: Door -Wood -Solid Core 42 369 0 336 336 13A-5ocs: Wall -Block, board insulation only, R-5 board 2034.8 7,632 0 3,889 3,889 insulation, open core, siding finish 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity, 321.4 468 0 468 468 no board Insulation, siding finish, wood studs CustomRoofl: Roof/Ceiling-Under attic or knee wall, 1372.5 1,811 0 2,416 2,416 Custom, Icynene under roof joist, with an R value of 22. Unvented attic. 22A-ph: Floor -Slab on grade, No edge insulation, no 158 6,437 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 23,477 0 17,225 17,225 People: 4 800 920 1,720 Equipment: 900 1,500 2,400 Lighting: 0 0 0 Ductwork: 9,036 1,877 6,611 8,489 Infiltration: Winter CFM: 81, Summer CFM: 44 2,674 1,813 719 2,532 Ventilation: Winter CFM: 69, Summer CFM: 69 2,275 2,864 1,137 4,001 Total Building Load Totals: 37,462 8,254 28,113 36,367 Check Figures - Total Building Supply CFM: 1,227 CFM Per Square ft.: 0.618 Square ft. of Room Area: 1,987 Square ft. Per Ton: 636 Volume (ft3) of Cond. Space: 18,711 Air Turnover Rate (per hour): 3.9 Building Loads Total Heating Required With Outside Air. 37,462 Btuh 37.462 MBH Total Sensible Gain: 28,113 Btuh 77 % Total Latent Gain: 8,254 Btuh 23 % Total Cooling Required With Outside Air. 36,367 Btuh 3.03 Tons (Based On Sensible + Latent) 3.12 Tons (Based On 75% Sensible Capacity) Notes..... _ _ _ Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. , ' � ,. 0 Ken Wismer Or -1UA-r: vlazmg-rrencn door, single pane clear glass, 45 945 0 1,550 1,550 insulated fiberglass frame, u-value 0.7 IA-hm-o: Glazing -Single pane, operable window, heat- 15 571 0 704 704 absorbing, metal frame no break, u-value 1.27 1A-hb-o: Glazing -Single pane, operable window, heat- 161.8 5,244 0 7,862 7,862 absorbing, metal frame with break, u-value 1.08 11 D: Door -Wood --Solid Core 42 369 0 336 336 13A-5ocs: Wall -Block, board insulation only, R-5 board 2034.8 7,632 0 3,889 3,889 insulation, open core, siding finish 128-0sw: Part -Frame, R-11 insulation in 2 x 4 stud cavity, 321.4 468 0 468 468 no board insulation, siding finish, wood studs CustomRoofl: Roof/Ceiling-Under attic or knee wall, 1372.5 1,811 0 2,416 2,416 Custom, Icynene under roof joist, with an R value of 22. Unvented attic. 22A-ph: Floor -Slab on grade, No edge insulation, no 158 6.437 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 23,477 0 17,225 17,225 People: 4 800 920 1,720 Equipment: 900 1,500 2,400 Lighting: 0 0 0 Ductwork: 9,036 1,877 6,611 8,489 Infiltration: Winter CFM: 81, Summer CFM: 44 2,674 1,813 719 2,532 Ventilation: Winter CFM:69, Summer CFM:69 2,275 2,864 1,137 4,001 System 1 Carrier Or Equivalent Load Totals: 37,462 8,264 28.113 36,367 Supply t;rM: 1,227 CFM Per Square ft.: 0.618 Square ft. of Room Area: 1,987 Square ft. Per Ton: 636 Volume (W) of Cond. Space: 18,711 Air Turnover Rate (per hour): 3.9 Total Sensible Gain: 28,113 Btuh 77 % Total Latent Gain: 8,254 Btuh 23 % Total Cooling Required With Outside Air: 36,367 Btuh 3.03 Tons (Based On Sensible + Latent) 3.12 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary Be sure to select a unit that meets both sensible and latent loads. Rhvac - Residential 3 Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Wismar Residence Port Saint Lucie, FL 34983 Pa a 7' System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) iuA-r: dazing-t-rencn 000r, single pane clear glass, insulated fiberglass frame, u-value 0.7 1A-hm-o: Glazing -Single pane, operable window, heat - absorbing, metal frame no break, u-value 1.27 IA-hb-o: Glazing -Single pane, operable window, heat - absorbing, metal frame with break, u-value 1.08 11 D: Door -Wood - Solid Core 13A-5ocs: Wall -Block, board insulation only, R-5 board Insulation, open core, siding finish 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity, no board insulation, siding finish, wood studs CustomRoof1: Roof/Ceiling-Under attic or knee wall, Custom, Icynene under roof joist, with an R value of 22. Unvented attic. 22A-ph: Floor -Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, heavy 15 571 0 704 704 161.8 5,244 0 7,862 7,862 42 369 0 336 336 2034.8 7,632 0 3,889 3,889 321.4 468 0 468 468 1372.5 1,811 0 2,416 2,416 158 6,437 Subtotals for structure: 23,477 0 17,225 17,225 People: 4 800 920 1,720 Equipment: 900 1,500 2,400 Lighting: 0 0 0 Ductwork: 9,036 0 6,611 6,611 Infiltration: Winter CFM: 81, Summer CFM: 44 2,674 1,813 719 2,532 System 1, Zone 1 Load Totals: 35,187 3,513 26,975 30.488 Square ft. of Room Area: 1,987 Square ft. Per Ton: 770 Volume (ft') of Cond. Space: 18,711 Air Tumover Rate (per hour): 3.9 Zone. Loads - Total Heating Required: 35,187 Btuh 35.187 MBH Total Sensible Gain: 26,975 Btuh 88 % Total Latent Gain: 3,513 Btuh 12 % Total Cooling Required: 30,488 Btuh 2.54 Tons (Based On Sensible + Latent) 2.58 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary Be sure to select a unit that meets both sensible and latent loads. r Rhvac - Residential & Light Commercial HVAC Loads _ - Elite Software Development; Inc. Ken Humphrey Wismer Residence Port Saint Lucie FL 34983 Page 8 Detailed Room Loads - Room 1 - Foyer (Average Load Procedure General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number. 1 Room Width: 8.5 ft. Zone Number: 1 Area: 68.0 sq.ft. Supply Air. 52 CFM Ceiling Height: 16.0 ft. Supply Air Changes: 2.9 AC/hr Volume: 1,088.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: -- 0 CFM Percent of Supply.: 8 % Runout Duct Size: 4 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 596 ft./min. Percent of Supply: 6 % Runout Air Velocity: 596 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.400 in.wg./l00 ft. Actual Summer Infil.: 3 CFM Item _Area Un Sen Clg . Let , _. -9 '1 DescriptionOuanh Value. _'- - HTM <` _-'. Loss •-• - 'WTM Gain Gain N -Wall-13A-5ocs 8.5 X 16 115 0.125 3.8 431 1.9 0 220 N -GIs-10A-f shgc-0.45 100%S 15 0.700 21.0 315 20.0 0 300 N -GIs-lA-hm-o shgo-0.52 100%S 6 1.270 38.1 228 30.0 0 180 (2) UP-Ceil-CustomRoofl 8 X 8.5 68 0.044 1.3 90 1.8 0 120 Floor -MA -ph 9 ft..Per. 9 1.358 40.7 367 0.0 0 0 Subtotals for Structure: 1,431 0 820 Infil.: Win.: 4.8, Sum.: 2.6 136 1.176 160 0.316 108 43 Ductwork: 550 280 Room Totals: 2,141 108 1,143 Ken Detailed Room Loads - Room 2 - Livina (Average Load Procedure) Room Length: 16.4 ft. System Number. 1 Room Width: 17.3 ft. Zone Number. 1 Area: 284.0 sq.ft. Supply Air. 385 CFM Ceiling Height: 16.0 ft. Supply Air Changes: 6.1 AC/hr Volume: 4,540.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 3 Actual Winter Vent.: 21 CFM Runout Air. 0 CFM Percent of Supply.: 5 % Runout Duct Size: 7 in. Actual Summer Vent.: 22 CFM Runout Air Velocity: 480 ft./min. Percent of Supply: 6 % RunoutAirVelocity: 480 ft./min. Actual Winter Infil.: 22 CFM Actual Loss: 0.119 in.wg./100 ft. Actual Summer Infil.: 12 CFM Item Area , . -U- a Htg .-Sen Clg Lat Sen Description Quantity Value HTM', Loss HTM. - Gain Gain N -Wall-13A-5ocs 3 X 16 48 0.125 3.8 180 1.9 0 92 NW-Wall-13A-5ocs 3 X 16 41 0.125 3.8 164 1.9 0 78 N -Wall-13A5ocs 8 X 16 98 0.125 3.8 368 1.9 0 187 NE-Wall-13A-5ocs 3 X 16 41 0.125 3.8 154 1.9 0 78 N -Wall-13A5ocs 3 X 16 48 0.125 3.8 180 1.9 0 92 E -Wall-13A-5ocs 16.4 X 16 217.4 0.125 3.8 815 1.9 0 416 W -GIs-lA-hb-o shgc-0.52 11%S 7 1.080 32.4 227 61.6 0 431 NW-GIs-lA-hb-o shgc-0.52 0%S 7 1.080 32.4 227 52.1 0 365 NE-GIs-lA-hb-o shgc-0.52 0%S 7 1.080 32.4 227 52.1 0 365 N -GIs-lA-hb-o shgc-0.52 100%S 30 1.080 32.4 972 27.1 0 814 (2) E -GIs-lA-hb-o shgc-0.52 16%S (2) 45 1.080 32.4 1,458 59.7 0 2,688 UP-Cell-CustomRoofl 16.4 X 17.3 283.7 0.044 1.3 375 1.8 0 499 Floor-22A-ph 39 ft..Per. 39 1.358 40.7 1,589 0.0 0 0 Subtotals for Structure: 7,080 0 6,183 Infil.: Win.: 22.4, Sum.: 12.1 630 1.174 740 0.316 502 199 Ductwork: 2.702 2.072 Room Totals: 10,522 502 8,454 -...,. i ., ;,: .. _, t. .1 . i� �:.., �, ,� I, 1.=. ,' .. `r` .: � .. _ �j i '� � , Rhvac - Res dential 3 Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Wismar Residence Port Saint Lucie FL 34983 Pa a 10 Detailed Room Loads - Room 3 - Stairwav (Average Load Procedure) Room Length: 21.0 ft. System Number: 1 Room Width: 4.0 ft. Zone Number: 1 Area: 84.0 sq.ft. Supply Air. 66 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.9 AC/hr Volume: 672.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 ActualWinterVent,: 7 CFM Runout Air. - — 0 CFM Percent of Supply.: 11 % Runout Duct Size: 5 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 483 ft./min. Percent of Supply: 6 % Runout Air Velocity: 483 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.193 in.wg./100 ft. Actual Summer Infil.: 2 CFM item. Area -U= ..=Htg,.; Sen Clg Lat San Description Quantity Value" -_ HTM - .Loss HTM" Gain Gain': W -Wall-13A-5ocs 6 X 8 39 0,125 3.8 146 1.9 0 75 N -Wall-13A-5ocs 8 X 8 64 0.125 3.8 240 1.9 0 122 S-Door-11 D 3 X 7 21 0.390 5.9 123 5.9 0 123 W -GIs-1A-hm-o shgc-0.52 27%S 9 1.270 38.1 343 58.2 0 524 Floor-22A-ph 35 ft-Per. 35 1.358 40.7 1,426 0.0 0 0 Subtotals for Structure: 2,492 0 1,058 Infil.: Win.: 4.0, Sum.: 2.1 112 1.170 131 0.313 89 35 Ductwork: 906 355 Room Totals: 3,529 89 1,448 I Ken Wismer Residence I Detailed Room Loads - Room 4 - Kitchen (Average Load Procedure) Room Length: 18.0 ft. System Number. 1 Room Width: 10.0 ft. Zone Number. 1 Area: 180.0 sq.ft. Supply Air. 92 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.8 AC/hr Volume: 1,440.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: — — - - 0 CFM Percent of Supply.: 4 % Runout Duct Size: 6 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 467 ft./min. Percent of Supply: 6 % Runout Air Velocity: 467 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.140 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item Area -U- _ Htq Sen Clg: Let _ Sen Description Quantity Value HTM - Loss HTM Gain - Gain Floor-2 ph 18 ft..Per. 18 1.358 40.7 733 0.0 0 0 Subtotals for Structure: 1,273 0 275 Infil.: Win.: 5.1, Sum.: 2.8 144 1.174 169 0.319 115 46 Ductwork: 498 494 Equipment: 600 1.200 Room Totals: 1,940 715 2,015 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development 'no. Ken Humphrey Wismar Residence Port Saint Lucie FL 34983 1w Page 12 Detailed Room Loads - Room 5 - Dining (Average Load Procedure General _ Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number. 1 Room Width: 8.0 ft. Zone Number: 1 Area: 104.0 sq.ft. Supply Air. 9 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 0.6 AC/hr Volume: 832.0 cu.ft. Required Vent.: 0 CFM Number of Registers_ 1 Actual Winter Vent.: 2 CFM Runout Air. 0 CFM Percent of Supply.: 19 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 99 ft./min. Percent of Supply: 6 % Runout Air Velocity: 99 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.012 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area -U5._ Htg _ .: Sen Clg Lat Sen: Description - Quanti Value •` HTM - Loss - HTM - Gain_ Gain W -Part-150/150-12B-Osw 12.3 X 8 98.4 0.097 1.5 143 1.5 0 143 Floor-22A-ph 1211L.Per. 12 1.358 40.7 489 0.0 0 0 Subtotals for Structure: 632 0 143 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 218 46 Room Totals: 850 0 189 Rhvac- Residential 6 Light Commercial HVAC Loads Elite Sof vare.Development, Inc. Ken Humphrey 1w Warner Residence Port Saint Lucie FL 34983 Noe 13 Detailed Room Loads - Room 6 - Bedroom 1 (Average Load Procedure General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number. 1 Room Width: 11.0 ft. Zone Number: 1 Area: 132.0 sq.ft. Supply Air. 88 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.0 AC/hr Volume: 1,056.0 cu.ft. Required Vent.: 0 CFM Number of Registers: -__ 1 Actual Winter Vent.: 6 CFM Runout Air. 0 CFM Percent of Supply.: 7 % Runout Duct Size: 5 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 646 ft./min. Percent of Supply: 6 % Runout Air Velocity: 646 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.342 in.wg./l00 ft. Actual Summer Infil.: 4 CFM ItemArea -U Htg: .. - Sen _Clg - .° Let Sed. Deson ion' -Quantity Value - HTM'^ - Loss HTM - Gain = Gain E -Wall-I3A-5ocs 11 X 8 60 0.125 3.8 225 1.9 0 115 S -Wall-13A-5ocs 12 X 8 96 0.125 3.8 360 1.9 0 184 E-Door-11 D 3 X 7 21 0.390 11.7 246 10.1 0 213 E -GIs-1A-hb-o shgc-0.52 11%S 7 1.080 32.4 227 61.6 0 431 Floor-22A-ph 23 ft.. Per. 23 1.358 40.7 937 0.0 0 0 Subtotals for Structure: 1,995 0 943 Infil.: Win.: 6.6, Sum.: 3.5 184 1.174 216 0.315 146 58 Ductwork: 764 474 People: 200 Iattper, 230 sen/per. 2 400 460 Room Totals: 2,975 546 1,935 M Rhvac - Residentiall& Llght Commerclal HVAC Loads Elite Software Development Inc. Ken Humphrey Wismar Residence Port Saint Lucie FL 34983 1W a a 14 [Detailed Room Loads - Room 7 - Walk /n Closet (Average Load Procedure) Room Length: 9.0 ft. System Number" 1 Room Width: 6.4 ft. Zone Number: 1 Area: 88.0 sq.ft. Supply Air. 7 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 0.9 AC/hr Volume: 461.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent:: 1 CFM Runout Air. _ 0 CFM Percent of Supply.: 19 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 79 ft./min. Percent of Supply: 6 % Runout Air Velocity: 79 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.008 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item ;Area -U- Htg : San Clg Let _ San Descdiation "- Quantity Value. - ' HTM Loss HTM - - -Gain Gain Floor-22A-ph 6 ft.. Per. 6 1.358 40.7 244 0.0 0 0 Subtotals for Structure: 436 0 98 Infil.: Win.: 1.8, Sum.: 1.0 51 1.172 60 0.313 41 16 Room Totals: 667 41 151 Rhvac - Residential & Light Commercial HVAC Loads Ken Humphrey Elite Software DevelopmerM Inc. WismerResidence Port Saint Lucie, FL 34983. Pane 15 Detailed Room. Loads - Room 8 - Bath 1 (Average Load Procedure General Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 9.5 ft. System Number. 1 Room Width: 6.0 ft. Zone Number: 1 Area: 57.0 sq.ft. Supply Air: 13 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.7 AC/hr Volume: 456.0 cu.ft. Required Vent.: 0 CFM Number of Registers:_ — 1 Actual Winter Vent.: 3 CFM Runout Air. 0 CFM Percent of Supply.: 20 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 151 ft./min. Percent of Supply: 6 % Runout Air Velocity: 151 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.027 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item Area -U- ! Htg,. ..Sen Clg Lat Sen Descri tion, - Quantity,< _ Value -`-- HTM- Loss HTM Gain Gain S -Wall-13A-5ocs 6.1 X 8 48.8 0.125 3.8 183 1.9 0 93 W -Part-15°/15°-12B-Osw 9.5 X 8 76 0.097 1.5 111 1.5 0 111 Floor-22A-ph 16 ft..Per. 16 1.358 40.7 662 0.0 0 0 Subtotals for Structure: 946 0 204 Infil.: Win.: 1.7, Sum.: 0.9 49 1.168 57 0.307 39 15 Ductwork: 347 71 Room Totals: 1,350 39 290 I Ken Wismer Detailed Room Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air. Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: 14.0 ft. 4.0 ft. 56.0 sq.ft. 8.0 ft. 448.0 cu.ft. 1 0 CFM 5 in. 626 ft./min. 626 ft./min. 0.322 in.wg./100 ft. _Area _ ;.:-L niianfity. vAil System Number: Zone Number. Supply Air: Supply Air Changes: Required Vent.: Actual -Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 85 CFM 11.4 AC/hr 0 CFM 2 CFM 3 % 5 CFM 6 % 2 CFM 1 CFM Clg. _ Let HTM Gain - NW-GIs-IOA-f shgc-0.45 0%S (2) 30 0.700 21.0 630 41.7 0 1,250 UP-Ceil-CustomRoofl 14 X 4 56 0.044 1.3 74 1.8 0 99 Subtotals for Structure: 802 0 1,399 Infil.: Win.: 2.0, Sum.: 1.1 56 1.179 66 0.321 45 18 Ductwork: 300 460 Room Totals: 1,168 45 1,877 W Rhvac - Residential & Light Commercial HVAC Loads ���, Elite Software Development, Inc. Ken Humphrey �7 Wismer Residence Port Saint Lucie FL 34983 Page 17 Detailed Room Loads - Room 10 - Walk In Closet (Average Load Procedure General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number. 1 Room Width: 8.0 ft. Zone Number: 1 Area: 64.0 sq.ft. Supply Air: 24 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.8 AC/hr Volume: 512.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: _ 2 CFM Runout Air: 0 CFM Percent of Supply.: 8 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 274 ft./min. Percent of Supply: 6 % Runout Air Velocity: 274 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.087 in.wg./l00 ft. Actual Summer Infil.: 2 CFM Item _ Area, -U- ._. Htg San Clg Let Sen, Desceiption - Quantity Value HTM > -Loss• HTM Gain Gain. N -Wall-13A-5ocs 8 X 8 64 0.125 3.8 240 1.9 0 122 W -Wall-13A-5ocs 8 X 8 64 0.125 3.8 240 1.9 0 122 UP-Ceil-CustomRoofl 8 X 8 64 0.044 1.3 84 1.8 0 113 Subtotals for Structure: 564 0 357 Infil.: Win.: 4.6, Sum.: 2.5 128 1.172 150 0.313 102 40 Ductwork: 247 129 Room Totals: 961 102 526 Knvac- nesmenvarp ugnt commerciai nvwc LOWS ��� Elite Software Development, Inc. Ken Humphrey �,7 Wismar Residence Port Saint Lucie, FL 34983 Paoe 18 Detailed Room Loads - Room 11 - Stairway (Average Load Procedure Room Length: 11.5 ft. System Number. 1 Room Width: 3.5 ft. Zone Number: 1 Area: 40.0 sq.ft. Supply Alr: 4 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 0.8 AC/hr Volume: 322.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: _ _ _ 0 CFM Percent of Supply.: 3 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 49 ft./min. Percent of Supply: 6 % Runout Air Velocity: 49 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.003 In.wg./100 ft. Actual Summer Infil.: 0 CFM Subtotals for Structure: 53 0 71 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Room Totals: 71 0 94 Knvac - tcemaenaai a ugnt UOmmerclal nvwc Loads Elite Sottware Development, Inc. Ken Humphrey Wismer Residence Port Saint Lucie, FL 34983 Pam 19 Detailed Room Loads - Room 12 - Master Bedroom (Average Load Procedure Room Length: 18.5 ft. System Number. 1 Room Width: 16.0 ft. Zone Number. 1 Area: 296.0 sq.ft. Supply Air: 201 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 6.1 AC/hr Volume: 2,368.0 cu.ft. Required Vent.: 0 CFM Number of Registers:- 2 Actual Winter Vent.: 7 CFM Runout Air.0 CFM Percent of Supply.: 3 % Runout Duct Size: 6 in. Actual Summer Vent.: 11 CFM Runout Air Velocity: 512 ft./min. Percent of Supply: 6 % Runout Air Velocity: 612 ft./min. Actual Winter Infil.: 10 CFM Actual Loss: 0.168 in.wg./100 ft. Actual Summer Infil.: 5 CFM Item ,— . i,Area -,--'�U- .. ,- Htg:Sen Clg Lat S ,n De`scriiiod Quanti _ Value- .. HTM _- Loss _ HTM Gain Gain W -Wall-I3A-5ocs 16.5 X 8 102 0.125 3.8 383 1.9 0 195 S -Wall-13A-5ocs 18.5 X 8 148 0.125 3.8 555 1.9 0 283 W -GIs-1A-hb-o shgc-0.52 16%S (2) 30 1.080 32.4 972 59.7 0 1,792 UP-Ceil-CustomRoofl 18.5 X 16 296 0.044 1.3 391 1.8 0 521 Subtotals for Structure: 2,301 0 2,791 Infil.: Win.: 10.0, Sum.: 6.4 280 1.175 329 0.314 223 88 Ductwork: 909 1,084 People: 200 lat/per, 230 sen/per. 2 400 460 Room Totals: 3,639 623 4,423 Rhvac - Residential & Light Commercial HVAC Loads KenHumphreyWismar Elite Software Development, Inc. Residence Port Saint Lucie FL 34983 Page 20 Detailed Room Loads - Room 13 - Master Bath (Average Load Procedure General Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 12.5 ft. System Number. 1 Room Width: 6.5 ft. Zone Number: 1 Area: 81.0 sq.ft. Supply Air: 32 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.9 AC/hr Volume: 650.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: - - 0 CFM Percent of Supply.: 6 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 366 ft./min. Percent of Supply: 6 % Runout Air Velocity: 366 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.153 in.wg./100 ft. Actual Summer Infil.: 2 CFM Item Area U -- _., ... , Htgc San Clg Let San Desch tion;; Quanti Value -_ _ HTM '` Loss HTM Gain N -Wall-13A-5ocs 12 X 8 89.1 0.125 3.8 334 1.9 0 170 N :GIs-lA-hb-o shgc-0.52 100%S 6.9 1.080 32.4 224 27.1 0 187 UP-Ceil-CustomRoofl 12.5 X 6.5 81.2 0.044 1.3 107 1.8 0 143 Subtotals for Structure: 685 0 500 Infil.: Win.: 3.4, Sum.: 1.8 96 1.177 113 0.313 76 30 Ductwork: 269 172 Room Totals: 1,047 76 702 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development Inc. Ken Humphrey ` Wismar Residence Port Saint Lucie FL 34983 Pa 21 Detailed Room Loads - Room 14 - Bedroom 2 (Average Load Procedure General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.5 ft. System Number. 1 Room Width: 11.5 ft. Zone Number. 1 Area: 144.0 sq.ft. Supply Air. 52 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.7 AC/hr Volume: 1,150.0 cu.ft. Required Vent.: 0 CFM _ Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air - -- 0 CFM Percent of Supply.: 6 % Runout Duct Size: 4 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 590 ft./min. Percent of Supply: 6 % Runout Air Velocity: 590 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.392 in.wg./l00 ft. Actual Summer Infil.: 2 CFM Item . Area ": U. -„ .,. Htg ' .Sen Clg Lat San Descnptiom Ouanti Value HTM - - Loss HTM Gain Gain S -Wall-13A-5ocs 12.5 X 8 85 0.125 3.8 319 1.9 0 163 S -GIs-IA-hb-o shgC-0.52 100%S 15 1.080 32.4 486 27.1 0 407 UP-Ceil-CustomRoofl 12.5 X 11.5 143.8 0.044 1.3 190 1.8 0 253 Subtotals for Structure: 995 0 823 Infil.: Win.: 3.6, Sum.: 1.9 100 1.170 117 0.320 80 32 Ductwork: 384 278 Room Totals: 1,496 80 1,133 Rhvac - Residential& Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Warner Residence Port Saint Lucie, FL 34983 Pana, 92 Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air. Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: - Room 15 - 9.5 ft. 8.0 ft. 76.0 sq.ft. 8.0 ft. 608.0 cu.ft. 1 0 CFM 4 in. 209 ft./min. 209 ft./min. 0.051 in.wg./100 ft. System Number., Zone Number: Supply Air. Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 18 CFM 1.8 AC/hr 0 CFM_ 1 CFM 7 % 1 CFM 6 % 3 CFM 1 CFM item, Area ,U ... • Htg ; , Sen Cig Lat Sen Description, Quantitw Value HTM Loss HTM Gain Gain UP-Cell-CustomRoofl 9.5 X 8 76 0.044 1.3 100 1.8 0 134 Subtotals for Structure: 385 0 279 Infil.: Win.: 2.7, Sum.: 1.5 76 1.171 89 0.316 60 24 Room Totals: 638 60 401 Detailed Room Loads - Room 16 - Hall (Average Load Procedure Room Length: 26.0 ft. System Number. 1 Room Width: 4.0 ft. Zone Number: 1 Area: 104.0 sq.ft. Supply Air: 15 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.1 AC/hr Volume: 832.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: — ___ 0 CFM Percent of Supply.: 5 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 175 ft./min. Percent of Supply: 6 % Runout Air Velocity: 175 ft./min. Actual Winter Infil.: 1 CFM Actual Loss: 0.037 in.wg./100 ft. Actual Summer Infil.: 1 CFM Itema , w s -Area U Htg tr , *r.Sen, Clg .:Lat . .__, Sen Descriptions Quantity b `:' Value ==. %t HTM ' . Loss HTM P ;Gain Gain UP-Ceil-CustomRoofl 26 X 4 104 0.044 1.3 137 1.8 0 183 Subtotals for Structure: 257 0 244 Infil.: Win.: 1.1, Sum.: 0.6 32 1.188 38 0.313 25 10 Ductwork: 102 82 Room Totals: 397 25 336 Rhvac - Res identist R Light Commercial HVAC Loads `� Elite Software Development, Inc. Ken Humphrey Wismar Residence Port Saint Lucie FL 34983 'Pace 24 Detailed Room Loads - Room 17 - Laund (Average Load Procedure General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number. 1 Room Width: 7.1 ft. Zone Number. 1 Area: 78.0 sq.ft. Supply Air: 56 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.4 AC/hr Volume: 625.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: - 0 CFM Percent of Supply.: 3 % Runout Duct Size: 4 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 643 ft./min. Percent of Supply: 6 % Runout Air Velocity: 643 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.464 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item ..'_-_ Area -U- :,, Htg {. . ' -San Clg Let Sen Descri lion _ : -QLia6tity Value•-'< HTM Loss HTM Gain - =Gain E -Wall-13A-5ocs 7 X 8 49.1 0.125 3.8 184 1.9 0 94 E -GIs-lA-hb-o shgc-0.52 27%S 6.9 1.080 32.4 224 55.4 0 382 UP-Cell-CustomRoofl 11 X 7.1 78.1 0.044 1.3 103 1.8 0 137 Subtotals for Structure: 511 0 613 Infrl.: Win.: 2.0, Sum.: 1.1 56 1.179 66 0.321 45 18 Ductwork: 199 302 Fquipment: 300 300 Room Totals: 776 345 1,233 Rhvac - Residential & Light Commercial HVAC Loads - - - Elite Software Development, Inc. Ken Humphrey Wismer Residence Port Saint Lucie, FL 34983 Page 25 Detailed Room Loads - Room 18 - Walk In Closet 2 (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number. 1 Room Width: 7.4 ft. Zone Number: 1 Area: 81.0 sq.ft. Supply Air. 28 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.6 AC/hr Volume: 651.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 0 CFM Percent of Supply.: 8 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 325 ft./min. Percent of Supply: 6 % Runout Air Velocity: 325 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.121 in.wg./100 ft. Actual Summer Infil.: 3 CFM Clg. Lat ._' . Sen Descri tion�-- - Q'uanh . F ' - Value ` HTM'_'- '' Loss HTM:" -Gain Gain 8 -Wall-13A-5ocs 7.4 X 8 59.2 0.125 3.8 222 1.9 0 113 E -Wall-I3A-5ocs 11 X 8 88 0.125 3.8 330 1.9 0 168 UP-Ceil-CustomRoof1 11 X 7.4 81.4 0.044 1.3 107 1.8 0 143 Subtotals for Structure: 659 0 424 Infil.: Win.: 5.2, Sum.: 2.8 147 1.175 173 0.319 117 47 Ductwork: 287 153 Room Totals: 1,119 117 624 System 1 Room Load Summa . 'Htg Min Run Run Cig Clg -Min Act' Room Area Sens Htg Duct, Duct Sens Lat Cig Sys, No Name SF____ Btuh CFM Size Val Btuh Btuh CFM CFM -Zone 1- ._ 1 Foyer 68 2,141 28 1-4 596 1,143 108 52 52- 2 Living 284 10,522 137 3-7 480 8,454 502 385 385w 3 Stairway 84 3,529 46 1-5 483 1,448 89 66 660 4 Kitchen 180 1,940 25- 1-6 467 2,015 715 92 92- 5 Dining 104 850 11 1-4 99 189 0 9 9- 6 Bedroom 1 132 2,975 39 1-5 646 1,935 546 88 88' 7 Walk In Closet 58 667 9 1-4 79 151 41 7 7- 8 Bath 1 57 1,350 18 1-4 151 290 39 13 13- 9 Bridge 56 1,168 15 1-5 626 1,877 45 85 85. 10 Walk In Closet 64 961 12 1-4 274 526 102 24 24' 11 Stairway 40 71 1 1-4 49 94 0 4 4- 12 Master Bedroom 296 3,539 46 2-6 512 4,423 623 201 201y 13 Master Bath 81 1,047 14 1-4 366 702 76 32 32p 14 Bedroom 2 144 1,496 19 1-4 590 1,133 80 52 52• 15 Bath 2 76 638 8 1-4 209 401 60 18 18, 16 Hall 104 397 5 1-4 175 336 25 15 15, 17 Laundry 78 776 10 1-4 643 1,233 345 56 56, 18 Walk In Closet 81 1,119 15 1-4 325 624 117 28 28% Ventilation 2,275 1,137 2,864 Duct Latent 1,877 ystem 1 total 1,987 37,462 457 28,113 8,254 1,227 1,227 System 1 Main Trunk Size: 12x18 in. Velocity: 818 ft./min Loss per 100 ft.: 0.094 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total - -Tons .Rnlit. Rfijh RfnN.. Rf"h Recommended: 3.12 75% /25% 28,113 Actual: 3.50 76%/24% 31,900 Type: 25HCA342A( Model: Brand: CARRIER Description: HEAT PUMP Efficiency: HSPF 8.3 Sound: Capacity: 40.5K BTU Sensible Capacity: n/a Latent Capacity: n/a 9,371 37,484 10,100 42,000 CARRIER CENTRAL UNIT 14 SEER 42K BTU 31,900 Btuh 10,100 Btuh