HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 600A-2004R EnergyGauge® 4.5.2
-FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name:
Wisner Residence
Builder.
Address:
Lot 729 Nettles Island
Permitting Office: St. Lucie County
City, State:
Ft. Pierce, FL
Permit Number.
Owner- -
Jurisdiction Number:
Climate Zone:
Central
1.
New construction or existing
New
2.
Single family or multi -family
Single family _
3.
Number of units, if multi -family
I
4.
Number of Bedrooms
3
5.
Is this a worst case?
No
6.
Conditioned floor area (112)
1987 ft2 _
7.
Glass typel and area: (Label reqd. by 13-104.4.5 if not default)
a. U-factor:
Description Area
(or Single or Double DEFAULT) 70(Sngle Default) 221.8 ft' _
b. SHGC:
(or Clear or Tint DEFAULT) 7b.
(Tint) 176.8 fit' _
8.
Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 158.0(p) ft _
b. N/A
_
c. N/A
_
9.
Wall types
a. Concrete, lnt hvsul, Exterior
R=5.0, 2034.8 ft
b. Frame, Wood, Adjacent
R=11.0, 321.4 112 _
c. NIA
_
d. N/A
_
e. N/A
_
10. Ceiling types
a. Under Attic
R=21.0, 1020.0 ft2
b. N/A
_
c. N/A
_
11. Ducts
_
a. Sup: Unc. Ret: Unc. AH: Garage
Sup. R=6.0, 250.0 It
b. N/A
12. Cooling systems
a. Central Unit SCANNED
b. N/A ®Y
St. Lucie c nlntt,
c. N/A
13. Heating system
a. Electric Heat Pump
b. N/A
c. NIA
14. Hot water systems
a. Electric Resistance
b. NIA
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.11 Total as -built points: 22484 PASS
r n Total base points: 24271
I hereby certify that the plartj nd-so-cifiraVris covered by
this calculation are in compliance with the Florida Energy
Code.
d PREPARED BY: r&10hgT1d6 17P06-! Cpl°IS
DATE: 3it9��9
I hereby certify that this buil 1 g, as designed, is in compliance
with the Florida Energy Co
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
OWNERIAGENT: BUILDING OFFICIAL: _
DATE: DATE:
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCPB v4.5.2)
;jjk
Cap: 42.0 kBtu/hr _
SEER: 14.00
Cap: 40.5 kBtuhu _
HSPF: 8.30
Cap: 50.0 gallons _
EF: 0.95 _
MZ-C' PT' -
y
TNERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 87.3
The higher the score, the more efficient the home.
, Lot 729 Nettles Island, Ft. Pierce, FL,
L New construction or existing
New _
2. Single family or mull -family
Single family _
3. Number of units, if multi -family
1 _
4. Number of Bedrooms
3 _
5. Is this a worst case?
No _
6. Conditioned floor area (ft')
1987 R'
_
7. Glass typel and area: (Label reqd. by 13-104.4.5 if not default)
a. U-factor:
Description .Area
(or Single or Double DEFAULT) 7a(Sngle Default) 221.8 ft'
b. SHGC:
(or Clear or Tint DEFAULT) 7b.
(Tint) 176.8 ft' _
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 158.0(p) ft _
b. N/A
_
c. N/A
_
9. Wall types
a. Concrete, Int Insul, Exterior
R=5.0, 2034.8 ft' _
b. Frame, Wood, Adjacent
R=I1.0, 321.4 ft' _
c. N/A
_
d. N/A
_
e. N/A
_
10. Ceiling types
a. Under Attic
R=21.0, 1020.0 ft' _
b. N/A
_
c. N/A
_
11. Ducts
a. Sup: Unc. Ret: Unc. AH: Garage
Sup. R=6.0, 250.0 ft _
b. N/A
12. Cooling systems
a. Central Unit
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
BF -Whole house fan,
PT -Programmable Thermostat,
M&C-Multizone cooling,
M2rH-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the ove energy saving features which will be installed (or exceeded)
in this home before fma ' pection. ( erwise, a new EPL Display Card will be completed
based on installed Co mpliant fie es.
Builder Signature: 'N9. Date:
Address of New
t
City/FL Zip:
Cap: 42.0 kBtm/hr _
SEER:14.00 _
Cap: 40.5 kBtu/br _
HSPF: 8.30
Cap: 50.0 gallons _
EF: 0.95
M71C, PT, -
*NOTE.- The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86 for a US EPADOE Enerv&ar'mdesignation),
your home may qualify for energy efflciency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsea ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efciency Code For Building
Construction, contact the Department of Community Affairs at 8501487-1824.
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on ages 2&.4.
EnergyGauge® (Version: FLKCP� v4.5.2)
kin
Summary Energy Code Results
Residential Whole Building Performance Method A
Project Title: Code Only
Lot 729 Nettles Island Wisner Residence Professional. Version
Ft. Pierce, FL Climate: Central
3/1912008
Building Loads
Base
As -Built
Summer:
38517 points
Summer:
37066 points
Winter:
7893 points
Winter:
10546 points
Hot Water:
6790 points
Hot Water: 6790 points
Total:
53200 points
Total:
54401 points
Energy Use
Base
As -Built
Cooling:
12518 points
Cooling:
10185 points
Heating:
4373 points
Heating:
5152 points
Hot Water:
7380 points
Hot Water: 7147 points
Total:
24271 points
Total:
22484 points
PASS
e-Ratio: 0.93
EnergyGauge®(Version: FLRCPB v4.5)
FORM 60OA-2004R EnergyGauge® 4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT#: I
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Points
12.Single,
Overhang
Floor Area
Type/SC
Omt
Len
Hgt
Area X SPM X SOF = Points
.18 1997.0 24.35
8709.0
1.Single, Clear
N
8.0
6.0
15.0
3DA9 0.68
309.0
Tint
N
8.0
6.0
6.0
24.46 0.68
100.0
3.Single, Tint
W
1.0
7.0
7.0
47.90 0.98
329.0
4.Single, Tint
NW
1.0
7.0
• 7.0
33.43 0.99
230.0
5.Single, Tint
NE
1.0
7.0
7.0
38.88 0.99
268.0
6.Single, Tint
N
1.0
5.0
30.0
24.46 0.96
705.0
7.Single, Tint
E
1.0
5.0
45.0
53.27 0.95
2278.0
S.Single, Tint
W
1.0
3.0
9.0
47.90 0.86
369.0
9.Single, Tint
E
1.0
7.0
7.0
53.27 0.98
366.0
110.8ingle, Clear
NW
1.0
6.0
30.0
40.72 0.97
1186.0
11.8ingle, Tint
W
1.0
5.0
30.0
47.90 0.95
1364.0
12.Single, Tint
N
1.0
3.0
6.9
24.46 0.90
152.0
13.Single, Tint
S
1.0
5.0
15.0
39.84 0.92
547.0
14.8ingle, Tint
E
1.0
3.0
6.9
53.27 0.86
315.0
As -Built Total:
221.8
8518.0
WALL TYPES
Area X BSPM
= Points
Type
R-Value
Area
X SPM =
Points
Adjacent
321A 0.70
225.0
1. Concrete, Int Insul, Extedor
5.0
2034.8
1.00
2034.6
Exterior
2034.8 1.90
3868.1
2. Frame, Wood, Adjacent
11.0
321.4
0.70
225.0
Base Total:
2356.2
4091.1
As -Built Total:
2356.2
2269.8
DOOR TYPES
Area X BSPM
= Points
Type
Area
X SPM =
Points
Adjacent
21.0 1.60
33.6
1.Exterior Wood
21.0
7.20
151.2
Exterior
21.0 4.80
100.E
2.Adjacent Wood
21.0
2.40
50.4
Base Total:
42.0
134.4
As -Built Total:
47-0
201.6
CEILING TYPES Area X BSPM = Points
Type
R Value Area X SPM X SCM =
Points
UnderAttic
1020.0 2.13
2172.6
1. Under Attic
21.0
1020.0 2.64 X 1.00
2692.8
Base Total:
1020.0
2172.6
As -Built Total:
1020.0
2692.8
FLOOR TYPES
Area X BSPM
= Points
Type
R-Value
Area
X SPM =
Points
Slab
158.0(p) -31.8
5024.4
1. Slab -On -Grade Edge Insulation
0.0 158.0(p
-31.90
5040.2
Raised
0.0 0.00
0.0
Base Total:
-6024A I
As -Built Total:
158.0
504D.2
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®IFlaRES2004R FLRCPB W.5.2
1.
♦
1.0
FORM 60OA-2004R EnergyGauge® 4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT #:
BASE
AS -BUILT
INFILTRATION Area X BSPM = Points
Area X SPM
= Points
1987.0
14.31 28434.0
1987.0
14.31
28434.0
Summer Base Points:
38516.7
Summer As -Built Points:
37066.0
Total Summer X System
= Cooling
Total X Cap
X Duct X System X
Credit
= Cooling
Points Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
lays 1: Central Unit 42000bbih ,SEER/EFF(14.0) Ducts:Unc(S),Unc(R),Gar(AH),R6.00NS)
37066 1.00
(1.09 x 1.150 x 1.00) 0.244
0.902
10185.4
38516.7 0.3250
12517.9
37066.0 1.00
1.250 0.244
0.902
10185.4
EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FIaRES'200411 FLRCPB v4.5.2
I
FORM 60OA-2004R
EnergyGauge® 4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
I ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT #: I
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM = Points
12.Single,
Overhang
Floor Area
Type/SC
Omt
Len
Hgt
Area X
WPM X WOF = Point
.18 1997.0 9.11 3258.0
1.Single, Clear
N
a.0
8.0
15.0
15.07 0.99
223.0
Tint
N
8.0
6.0
6.0
15.38 0.99
91.0
Mingle, Tint
W
1.0
7.0
7.0
13.80 1.00
96.0
4.Single, Tint
NW
1.0
7.0
7.0
15.30 1.00
106.0
5.8ingle, Tint
NE
1.0
7.0
7.0
15.07 1.00
105.0
6.Single, Tint
N
1.0
5.0
30.0
15.38 1.00
460.0
7.Single, Tint
E
1.0
5.0
45.0
13.04 1.01
593.0
8.Single, Tint
W
1.0
3.0
9.0
13.80 1.02
126.0
9.Single, Tint
E
1.0
7.0
7.0
13.04 1.01
91.0
10.Single, Clear
NW
1.0
6.0
30.0
14.97 1.00
448.0
11.Single, Tint
W
1.0
5.0
30.0
13.80 1.01
416.0
12.Single, Tint
N
1.0
3.0
6.9
15.38 1.00
105.0
13.Single, Tint
S
1.0
5.0
15.0
10.88 1.02
166.0
14.5ingle, Tint
E
1.0
3.0
6.9
13.04 1.03
92.0
As -Built Total:
221.8
3118.0
WALL TYPES
Area X BWPM =
Points
Type
R-Value
Area X WPM =
Points
Adjacent
321A 1.80
578.5
1. Concrete, Int Insul, Exterior
5.0
2034.8
2.90
5900.9
Exterior
2034.8 2.00
4069.6
2. Frame, Wood, Adjacent
11.0
321A
1.80
578.5
Base Total:
2356.2
4648.1
As-BuikTotal:
2366.2
6479.4
DOOR TYPES
Area X BWPM =
Points
Type
Area
X WPM =
Points
Adjacent
21.0 4.00
84.0
1.Extedor Wood
21.0
7.60
159.6
Exterior
21.0 5.10
107.1
2Adjacent Wood
21.0
5.90
123.9
Base Total:
42.0
191.1
As -Built Total:
42.0
283.5
CEILING TYPES Area X BWPM =
Points
Type
R-Value Area X WPM X WCM =
Points
Under AtBc
1020.0 0.64
652.8
1. Under Attic
21.0
1020.0
0.81 X 1.00
826.2
Base Total:
1020.0
652.8
As -Built Total:
1020.0
826.2
FLOOR TYPES
Area X BWPM =
Points
Type
R-Value
Area X WPM =
Points
Slab
158.0(p) -1.9
-300.2
1. Slab -On -Grade Edge Insulation
0.0 158.0(p
2.50
395.0
Raised
o.o 0.00
0.0
Base Total:
-3DD.2
As -Built Total:
158.0
395.0
EnergyGaugeO DCA Form 60OA-2004R EnergyGauge40/FlaRES'2004R FLRCPB v4.5.2
0
----
-- --- -
IT
FORM 60OA-2004R
1L-
EnergyGauge® 4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT*
BASE
AS -BUILT
INFILTRATION
Area X BWPM = Points
Area X WPM
= Points
1987.0
-0.28 -556.4
1987.0
-0.28
-556.4
Winter Base Points:
7893.5
Winter As -Built Points:
10546.8
Total Winter X
System =
Heating
Total X Cap
X Duct X System X
Credit
= Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Electric Heat Pump 40500 btuh ,EFF(8.3) Ducts:Unc(S),Unc(R),Gar(AH),R6.0
10545.8 1.000
(1.078 x 1.160 x 1.00) 0.411
0.950
5151.5
7893.5
0.5540
4373.0
10545.8 1.00
1.250 0.411
0.950
5161.6
EnergyGaugeTM DCA Form 60DA-20UR EnergyGauge®IFIaRES'20D4R FLRCPB v4.5.2
._\,,.
/yy�..:
d
(\
\\)\/
(
_
zz.yi
�
}
�§�.
}
�
'
,��
.
.
}
},
\
'{
�
�
`{
\
.
}\\`�
� ��
��.
�
}
}
\
iy
�}`®
;
�\/:)\\\).�
(
� ;§.
�3!
;
..5
e
/ ;
�
v�{�
:
�
;
. ��}
-�
23)/�
/ �
: :z;
.
�
�}.>^)\}
1
�
i�'>}}j.!&�
'
�
}
�\&T|•:.:
�
�~
§(`f
!\�
�
`
!�
_
� � ._�
� (�
�
; §
��
!
\
� :
( (
}
�
\\}\ /{zP
!
"
`
: `
):(
i
}
�
\
\�(
`
(
})�\�}
�
!
. i/i
2\!\�
}:{\?
,.
`�
,
�
�
{�
�;z
{-
�
!
�
,
,
`
;\
;
�
.
�
.�1��
!
<
��!\�
}
�
1\�
/`
��)_��:
��./d
} }
2
\
�
2
(:�
�
\
d \2
� �
FORM 60OA-2004R
EnergyGauge® 4.5.2
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT #:
BASE
AS -BUILT
WATER HEATING
Number of X Multiplier =
, Total
Tank EF
Number of X Tank X Multiplier X Credit = Total
Bedrooms
Volume
Bedrooms Ratio Multiplier
3 2460.00
7380.0
50.0 0.95
3 1.00 2382.32 1.00 7146.9
As -Built Total:
7146.9
CODE COMPLIANCE STATUS
BASE
AS -BUILT
Cooling + Heating + Hot Water = Total
Points Points Points Points
Cooling + Heating + Hot Water = Total
Points Points Points Points
12618 4373 7380 24271
10185 5152 7147 22484
PASS
EnergyGauge" DCA Form 600A-2004R EnergyGauge4D/FIaRES'2004R FLRCPB V4.5.2
-7
;t- -,-- I
FORM 60OA-2004R
EnergyGauge® 4.5.2
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: Lot 729 Nettles Island, Ft. Pierce, FL, PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1 ABCA.1
Maximum:.3 cfrm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Wells
606.1 ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiftmtion barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.tABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss orjoint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimcter, penetrations and scams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 12" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker electric or Cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All duds, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducal in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTM DCA Forth 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCPB v4.5.2
Ll
n
1'
Wismer Residence
HVAC Load Calculations
for
Wismer
Lot 729 Nettles Island
Port St. Lucie, Florida
kL
- VAC HVACRzsxDH'rt VAC LOADD
S
SCANNED
StlucieCnunb/
Prepared By:
Residential Energy Calds
Wednesday, March 19, 2008
Project Report
Designed By:
Robert Fullan
Project Date:
Thursday, February 14, 2008
Client Name:
Wismar
Client Address:
Lot 729 Nettles Island
Client City:
Port St. Lucie, Florida
Company Name:
Residential Energy Calc's
Design Data
_
Reference City:
Fort Pierce, Florida
Daily Temperature Range:
Medium
Latitude:
27 Degrees
Elevation:
25 ft.
Altitude Factor.
0.999
Elevation Sensible Adj. Factor. 1.000
Elevation Total Adj. Factor.
1.000
Elevation Heating Adj. Factor.
1.000
Elevation Heating Adj. Factor:
1.000
Outdoor Outdoor Indoor Indoor
Grains
Dry Bulb Wet Bulb Rel.Hum Dry Bulb
Difference
Winter.
42 0 30 72
3
Summer.
90 78 50 75
61
Square ft of Room Area: 1,987
Volume (ft') of Cond. Space: 18,711
Square ft. Per Ton: 636
Air Turnover Rate (per hour): 3.9
Building Loads
Total Heating Required With Outside Air.
37,462
Btuh
37.462 MBH
Total Sensible Gain:
28,113
Btuh
77 %
Total Latent Gain:
8,254
Btuh
23 %
Total Cooling Required With Outside Air.
36,367
Btuh
3.03 Tons (Based On Sensible + Latent)
3.12 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Rhvac - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Wismer Residence
Port Saint Lucie FL 34983
Pa e 3
Miscellaneous Report
System 1 Carrier Or Equivalent Outdoor
Outdoors Indoor Indoor
Grains
Input Data Dry
Bulb
Wet Bulb R_ el.Hum Dry Bulb Difference
Winter.
42
0 30 72
3.44
Summer:
90
78 50 75
61.09
Duct Sizin In uts
Main Trunk
Runouts
Calculate: Yes
Yes
Use Schedule: Yes
Yes
Roughness Factor. 0.00300
0.01000
Pressure Drop: 0.1000 in.wg./l00 ft.
0.1000 in.wg./l00 ft.
Minimum Velocity. 650 ft./min
450 ft./min
Maximum Velocity: 900 ft./min
750 ft./min
Minimum Height: 0 in.
0 in.
Maximum Height: 0 in.
0 in.
Outside Air Data
_
Winter
Summer
Infiltration: 0.260 AC/hr
0.140 AC/hr
Above Grade Volume: X 18,711 Cu.ft.
X 18,711 Cu.ft.
4,865 Cu.ft./hr
2,620 Cu.ft./hr
X 0.0167
X 0.0167
Total Building Infiltration: 81 CFM
44 CFM
Total Building Ventilation: 69 CFM
69 CFM
—System 1—
Infiltration & Ventilation Sensible Gain Multiplier.
16.49
= (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier:
41.50
= (0.68 X 0.999 X 61.09 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier.
32.97
= (1.10 X 0.999 X 30.00 Winter Temp. Difference)
Duct Load FactorScenarios fors stem 1
Attic
Duct Duct Surface
From
No. Type Description Location
Ceiling
Leakage Insulation _ Area
MDD
1 Supply Main Attic
16B
0.12 6 536
No
1 Return Main Attic
16B
0.24 6 99
No
ILL I�I� -�I�I I10 9DIV 9,llr f, 'N I''01�
4C'? 4IY PIY'^1'410ED w1b;3ml
G N mlNCO �'�'Vll�, d C'N I�j fij ��O N C I
m e I=15ia N'N �. d m I$iRla IgI I= I DIET, ^
Io.l N'oIm Flo I'Ig o'�'� 'I'1
51
3 W WI9I
O I N glal IG
i ,o
I I I l i l i i l l I I I I I
l ! I I I I l
� III11II ,II
III I i it
'
i
I I I
I I
- -L —1 J—I_ i A
A L
Lppa I yy IN I I I I'I Q IWN i f0
V_
I I(O _W
I_A_LA ALN I^0_�IAOOoV--�VL
AW IN,W A,;IV AI _V V
It_Wif iOWiy�IwiN__t_NJ1A �O I_�_IfWjl'�_IVII�I_A W;VVi —II_V
W�W
m
'N IO W V NI IO AW W OO iV
I��
V N N O11m �W6O Ntr tO �m'O Vt L�N IOoyW
Ia'A
I I I I
!
i-m+'.mi �W I�I�I��IN
-A+IOVo IN NI�I�OIV_!W ��I�L�IOJjJ
I I �I�IWj I�^�, 'NI I+IW IO N �fWil
:...1V 1W IW A Ipp 10I tpI�IW,W tfOIW I ItT IIfI��T1��,
ro'W VLGWO W JI(WO �W
'N VIJ
Nl�py�IA
—L _� T-4—.--i—I•--�--
I
1 i I
fTIOIUI m O AIm;- IN IN I Mimi. Of IV IONoIV
1_IV I`V
I 1
NI+ + N W10• NWr ND TIC OII
A IN W V_I W_ t0 W_ N i
N
i �ili �ilii�'lilil�lilil',i
3
vac - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Wismer Residence
Part Saint Lucie FL 34983
Pa e,6
Total Bugqft Summary Loads
Component
Area Sen
Lat
Sen
Total
Description
Quan Loss
Gain
Gain
Gain
10A-f: Glazing -French door, single pane clear glass,
45 945
0
1,550
1,550
insulated fiberglass frame, u-value 0.7
1A-hm-o: Glazing -Single pane, operable window, heat-
15 571
0
704
704
absorbing, metal frame no break, u-value 1.27
IA-hb-o: Glazing -Single pane, operable window, heat-
161.8 5.244
0
7,862
7,862
absorbing, metal frame with break, u-value 1.08
11 D: Door -Wood -Solid Core
42 369
0
336
336
13A-5ocs: Wall -Block, board insulation only, R-5 board
2034.8 7,632
0
3,889
3,889
insulation, open core, siding finish
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity,
321.4 468
0
468
468
no board Insulation, siding finish, wood studs
CustomRoofl: Roof/Ceiling-Under attic or knee wall,
1372.5 1,811
0
2,416
2,416
Custom, Icynene under roof joist, with an R value of
22. Unvented attic.
22A-ph: Floor -Slab on grade, No edge insulation, no
158 6,437
0
0
0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure:
23,477
0
17,225
17,225
People:
4
800
920
1,720
Equipment:
900
1,500
2,400
Lighting:
0
0
0
Ductwork:
9,036
1,877
6,611
8,489
Infiltration: Winter CFM: 81, Summer CFM: 44
2,674
1,813
719
2,532
Ventilation: Winter CFM: 69, Summer CFM: 69
2,275
2,864
1,137
4,001
Total Building Load Totals:
37,462
8,254
28,113
36,367
Check Figures
-
Total Building Supply CFM: 1,227
CFM Per Square ft.:
0.618
Square ft. of Room Area: 1,987
Square ft. Per Ton:
636
Volume (ft3) of Cond. Space: 18,711
Air Turnover Rate (per hour):
3.9
Building Loads
Total Heating Required With Outside Air. 37,462
Btuh 37.462 MBH
Total Sensible Gain: 28,113
Btuh 77 %
Total Latent Gain: 8,254
Btuh 23 %
Total Cooling Required With Outside Air. 36,367
Btuh 3.03 Tons (Based On Sensible + Latent)
3.12 Tons (Based On 75%
Sensible Capacity)
Notes..... _ _ _
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
,
' �
,.
0
Ken
Wismer
Or
-1UA-r: vlazmg-rrencn door, single pane clear glass,
45
945
0
1,550
1,550
insulated fiberglass frame, u-value 0.7
IA-hm-o: Glazing -Single pane, operable window, heat-
15
571
0
704
704
absorbing, metal frame no break, u-value 1.27
1A-hb-o: Glazing -Single pane, operable window, heat-
161.8
5,244
0
7,862
7,862
absorbing, metal frame with break, u-value 1.08
11 D: Door -Wood --Solid Core
42
369
0
336
336
13A-5ocs: Wall -Block, board insulation only, R-5 board
2034.8
7,632
0
3,889
3,889
insulation, open core, siding finish
128-0sw: Part -Frame, R-11 insulation in 2 x 4 stud cavity,
321.4
468
0
468
468
no board insulation, siding finish, wood studs
CustomRoofl: Roof/Ceiling-Under attic or knee wall,
1372.5
1,811
0
2,416
2,416
Custom, Icynene under roof joist, with an R value of
22. Unvented attic.
22A-ph: Floor -Slab on grade, No edge insulation, no
158
6.437
0
0
0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure:
23,477
0
17,225
17,225
People:
4
800
920
1,720
Equipment:
900
1,500
2,400
Lighting:
0
0
0
Ductwork:
9,036
1,877
6,611
8,489
Infiltration: Winter CFM: 81, Summer CFM: 44
2,674
1,813
719
2,532
Ventilation: Winter CFM:69, Summer CFM:69
2,275
2,864
1,137
4,001
System 1 Carrier Or Equivalent Load Totals:
37,462
8,264
28.113
36,367
Supply t;rM: 1,227 CFM Per Square ft.: 0.618
Square ft. of Room Area: 1,987 Square ft. Per Ton: 636
Volume (W) of Cond. Space: 18,711 Air Turnover Rate (per hour): 3.9
Total Sensible Gain:
28,113 Btuh
77
%
Total Latent Gain:
8,254 Btuh
23
%
Total Cooling Required With Outside Air:
36,367 Btuh
3.03
Tons (Based On Sensible + Latent)
3.12
Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary
Be sure to select a unit that meets both sensible and latent loads.
Rhvac - Residential 3 Light Commercial HVAC Loads Elite Software Development, Inc.
Ken Humphrey Wismar Residence
Port Saint Lucie, FL 34983 Pa a 7'
System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms)
iuA-r: dazing-t-rencn 000r, single pane clear glass,
insulated fiberglass frame, u-value 0.7
1A-hm-o: Glazing -Single pane, operable window, heat -
absorbing, metal frame no break, u-value 1.27
IA-hb-o: Glazing -Single pane, operable window, heat -
absorbing, metal frame with break, u-value 1.08
11 D: Door -Wood - Solid Core
13A-5ocs: Wall -Block, board insulation only, R-5 board
Insulation, open core, siding finish
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity,
no board insulation, siding finish, wood studs
CustomRoof1: Roof/Ceiling-Under attic or knee wall,
Custom, Icynene under roof joist, with an R value of
22. Unvented attic.
22A-ph: Floor -Slab on grade, No edge insulation, no
insulation below floor, any floor cover, passive, heavy
15 571 0 704 704
161.8
5,244
0
7,862
7,862
42
369
0
336
336
2034.8
7,632
0
3,889
3,889
321.4
468
0
468
468
1372.5 1,811 0 2,416 2,416
158 6,437
Subtotals for structure:
23,477
0
17,225
17,225
People:
4
800
920
1,720
Equipment:
900
1,500
2,400
Lighting:
0
0
0
Ductwork:
9,036
0
6,611
6,611
Infiltration: Winter CFM: 81, Summer CFM: 44
2,674
1,813
719
2,532
System 1, Zone 1 Load Totals:
35,187
3,513
26,975
30.488
Square ft. of Room Area:
1,987
Square ft. Per Ton: 770
Volume (ft') of Cond. Space:
18,711
Air Tumover Rate (per hour): 3.9
Zone. Loads -
Total Heating Required:
35,187
Btuh
35.187 MBH
Total Sensible Gain:
26,975
Btuh
88 %
Total Latent Gain:
3,513
Btuh
12 %
Total Cooling Required:
30,488
Btuh
2.54 Tons (Based On Sensible + Latent)
2.58 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary
Be sure to select a unit that meets both sensible and latent loads.
r Rhvac - Residential & Light Commercial HVAC Loads
_ -
Elite Software Development; Inc.
Ken Humphrey
Wismer Residence
Port Saint Lucie FL 34983
Page 8
Detailed Room Loads - Room 1 - Foyer
(Average Load Procedure
General
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
8.0 ft.
System Number.
1
Room Width:
8.5 ft.
Zone Number:
1
Area:
68.0 sq.ft.
Supply Air.
52 CFM
Ceiling Height:
16.0 ft.
Supply Air Changes:
2.9 AC/hr
Volume:
1,088.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
4 CFM
Runout Air: --
0 CFM
Percent of Supply.:
8 %
Runout Duct Size:
4 in.
Actual Summer Vent.:
3 CFM
Runout Air Velocity:
596 ft./min.
Percent of Supply:
6 %
Runout Air Velocity:
596 ft./min.
Actual Winter Infil.:
5 CFM
Actual Loss:
0.400 in.wg./l00 ft. Actual Summer Infil.:
3 CFM
Item
_Area Un Sen
Clg
. Let ,
_. -9 '1
DescriptionOuanh
Value. _'- - HTM <` _-'. Loss •-• -
'WTM
Gain
Gain
N -Wall-13A-5ocs 8.5 X 16
115
0.125 3.8 431
1.9
0
220
N -GIs-10A-f shgc-0.45 100%S
15
0.700 21.0 315
20.0
0
300
N -GIs-lA-hm-o shgo-0.52 100%S
6
1.270 38.1 228
30.0
0
180
(2)
UP-Ceil-CustomRoofl 8 X 8.5
68
0.044 1.3 90
1.8
0
120
Floor -MA -ph 9 ft..Per.
9
1.358 40.7 367
0.0
0
0
Subtotals for Structure:
1,431
0
820
Infil.: Win.: 4.8, Sum.: 2.6
136
1.176 160
0.316
108
43
Ductwork:
550
280
Room Totals:
2,141
108
1,143
Ken
Detailed Room Loads - Room 2 - Livina (Average Load Procedure)
Room Length:
16.4
ft.
System Number.
1
Room Width:
17.3
ft.
Zone Number.
1
Area:
284.0
sq.ft.
Supply Air.
385
CFM
Ceiling Height:
16.0
ft.
Supply Air Changes:
6.1
AC/hr
Volume:
4,540.0
cu.ft.
Required Vent.:
0
CFM
Number of Registers:
3
Actual Winter Vent.:
21
CFM
Runout Air.
0
CFM
Percent of Supply.:
5
%
Runout Duct Size:
7
in.
Actual Summer Vent.:
22
CFM
Runout Air Velocity:
480
ft./min.
Percent of Supply:
6
%
RunoutAirVelocity:
480
ft./min.
Actual Winter Infil.:
22
CFM
Actual Loss:
0.119
in.wg./100 ft.
Actual Summer Infil.:
12
CFM
Item
Area , . -U-
a Htg .-Sen
Clg Lat Sen
Description
Quantity Value
HTM', Loss
HTM. - Gain Gain
N -Wall-13A-5ocs 3 X 16
48
0.125
3.8
180
1.9
0
92
NW-Wall-13A-5ocs 3 X 16
41
0.125
3.8
164
1.9
0
78
N -Wall-13A5ocs 8 X 16
98
0.125
3.8
368
1.9
0
187
NE-Wall-13A-5ocs 3 X 16
41
0.125
3.8
154
1.9
0
78
N -Wall-13A5ocs 3 X 16
48
0.125
3.8
180
1.9
0
92
E -Wall-13A-5ocs 16.4 X 16
217.4
0.125
3.8
815
1.9
0
416
W -GIs-lA-hb-o shgc-0.52 11%S
7
1.080
32.4
227
61.6
0
431
NW-GIs-lA-hb-o shgc-0.52 0%S
7
1.080
32.4
227
52.1
0
365
NE-GIs-lA-hb-o shgc-0.52 0%S
7
1.080
32.4
227
52.1
0
365
N -GIs-lA-hb-o shgc-0.52 100%S
30
1.080
32.4
972
27.1
0
814
(2)
E -GIs-lA-hb-o shgc-0.52 16%S (2)
45
1.080
32.4
1,458
59.7
0
2,688
UP-Cell-CustomRoofl 16.4 X 17.3
283.7
0.044
1.3
375
1.8
0
499
Floor-22A-ph 39 ft..Per.
39
1.358
40.7
1,589
0.0
0
0
Subtotals for Structure:
7,080
0
6,183
Infil.: Win.: 22.4, Sum.: 12.1
630
1.174
740
0.316
502
199
Ductwork:
2.702
2.072
Room Totals: 10,522 502 8,454
-...,.
i
.,
;,:
..
_,
t.
.1
.
i�
�:..,
�,
,�
I, 1.=.
,'
..
`r`
.: �
.. _
�j
i
'�
� ,
Rhvac - Res dential 3 Light Commercial HVAC Loads Elite Software Development, Inc.
Ken Humphrey Wismar Residence
Port Saint Lucie FL 34983 Pa a 10
Detailed Room Loads - Room 3 - Stairwav (Average Load Procedure)
Room Length:
21.0
ft.
System Number:
1
Room Width:
4.0
ft.
Zone Number:
1
Area:
84.0
sq.ft.
Supply Air.
66
CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
5.9
AC/hr
Volume:
672.0
cu.ft.
Required Vent.:
0
CFM
Number of Registers:
1
ActualWinterVent,:
7
CFM
Runout Air. - —
0
CFM
Percent of Supply.:
11
%
Runout Duct Size:
5
in.
Actual Summer Vent.:
4
CFM
Runout Air Velocity:
483
ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
483
ft./min.
Actual Winter Infil.:
4
CFM
Actual Loss:
0.193
in.wg./100 ft.
Actual Summer Infil.:
2
CFM
item.
Area -U=
..=Htg,.; Sen
Clg
Lat San
Description
Quantity Value"
-_ HTM - .Loss
HTM" Gain Gain':
W -Wall-13A-5ocs 6 X 8
39
0,125
3.8
146
1.9
0
75
N -Wall-13A-5ocs 8 X 8
64
0.125
3.8
240
1.9
0
122
S-Door-11 D 3 X 7
21
0.390
5.9
123
5.9
0
123
W -GIs-1A-hm-o shgc-0.52 27%S
9
1.270
38.1
343
58.2
0
524
Floor-22A-ph 35 ft-Per.
35
1.358
40.7
1,426
0.0
0
0
Subtotals for Structure:
2,492
0
1,058
Infil.: Win.: 4.0, Sum.: 2.1
112
1.170
131
0.313
89
35
Ductwork:
906
355
Room Totals: 3,529 89 1,448
I Ken
Wismer Residence I
Detailed Room Loads - Room 4 - Kitchen (Average Load Procedure)
Room Length:
18.0
ft.
System Number.
1
Room Width:
10.0
ft.
Zone Number.
1
Area:
180.0
sq.ft.
Supply Air.
92
CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
3.8
AC/hr
Volume:
1,440.0
cu.ft.
Required Vent.:
0
CFM
Number of Registers:
1
Actual Winter Vent.:
4
CFM
Runout Air: — — -
- 0
CFM
Percent of Supply.:
4
%
Runout Duct Size:
6
in.
Actual Summer Vent.:
5
CFM
Runout Air Velocity:
467
ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
467
ft./min.
Actual Winter Infil.:
5
CFM
Actual Loss:
0.140
in.wg./100 ft.
Actual Summer Infil.:
3
CFM
Item
Area -U-
_ Htq Sen
Clg:
Let _ Sen
Description
Quantity Value
HTM - Loss
HTM Gain - Gain
Floor-2 ph 18 ft..Per.
18 1.358 40.7 733 0.0
0
0
Subtotals for Structure:
1,273
0
275
Infil.: Win.: 5.1, Sum.: 2.8
144 1.174 169 0.319
115
46
Ductwork:
498
494
Equipment:
600
1.200
Room Totals:
1,940
715
2,015
Rhvac - Residential & Light Commercial HVAC Loads
Elite Software Development 'no.
Ken Humphrey
Wismar Residence
Port Saint Lucie FL 34983
1w
Page 12
Detailed Room Loads - Room 5 - Dining (Average Load Procedure
General _
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
13.0
ft.
System Number.
1
Room Width:
8.0
ft.
Zone Number:
1
Area:
104.0
sq.ft.
Supply Air.
9
CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
0.6
AC/hr
Volume:
832.0
cu.ft.
Required Vent.:
0
CFM
Number of Registers_
1
Actual Winter Vent.:
2
CFM
Runout Air.
0
CFM
Percent of Supply.:
19
%
Runout Duct Size:
4
in.
Actual Summer Vent.:
0
CFM
Runout Air Velocity:
99
ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
99
ft./min.
Actual Winter Infil.:
0
CFM
Actual Loss:
0.012
in.wg./100
ft. Actual Summer Infil.:
0
CFM
Item
Area
-U5._ Htg _ .: Sen
Clg
Lat
Sen:
Description -
Quanti
Value •` HTM - Loss -
HTM -
Gain_
Gain
W -Part-150/150-12B-Osw 12.3 X 8
98.4
0.097 1.5 143
1.5
0
143
Floor-22A-ph 1211L.Per.
12
1.358 40.7 489
0.0
0
0
Subtotals for Structure:
632
0
143
Infil.: Win.: 0.0, Sum.: 0.0
0
0 0
0
0
0
Ductwork:
218
46
Room Totals:
850
0
189
Rhvac- Residential 6 Light Commercial HVAC Loads
Elite Sof vare.Development, Inc.
Ken Humphrey
1w
Warner Residence
Port Saint Lucie FL 34983
Noe 13
Detailed Room Loads - Room 6 - Bedroom 1 (Average Load Procedure
General
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
12.0 ft.
System Number.
1
Room Width:
11.0 ft.
Zone Number:
1
Area:
132.0 sq.ft.
Supply Air.
88 CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
5.0 AC/hr
Volume:
1,056.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers: -__
1
Actual Winter Vent.:
6 CFM
Runout Air.
0 CFM
Percent of Supply.:
7 %
Runout Duct Size:
5 in.
Actual Summer Vent.:
5 CFM
Runout Air Velocity:
646 ft./min.
Percent of Supply:
6 %
Runout Air Velocity:
646 ft./min.
Actual Winter Infil.:
7 CFM
Actual Loss:
0.342 in.wg./l00 ft.
Actual Summer Infil.:
4 CFM
ItemArea
-U
Htg: .. - Sen
_Clg - .°
Let
Sed.
Deson ion' -Quantity
Value
- HTM'^ - Loss
HTM -
Gain =
Gain
E -Wall-I3A-5ocs 11 X 8
60
0.125
3.8 225
1.9
0
115
S -Wall-13A-5ocs 12 X 8
96
0.125
3.8 360
1.9
0
184
E-Door-11 D 3 X 7
21
0.390
11.7 246
10.1
0
213
E -GIs-1A-hb-o shgc-0.52 11%S
7
1.080
32.4 227
61.6
0
431
Floor-22A-ph 23 ft.. Per.
23
1.358
40.7 937
0.0
0
0
Subtotals for Structure:
1,995
0
943
Infil.: Win.: 6.6, Sum.: 3.5
184
1.174 216
0.315
146
58
Ductwork:
764
474
People: 200 Iattper, 230 sen/per.
2
400
460
Room Totals:
2,975
546
1,935
M
Rhvac - Residentiall& Llght Commerclal HVAC Loads Elite Software Development Inc.
Ken Humphrey Wismar Residence
Port Saint Lucie FL 34983 1W a a 14
[Detailed Room Loads - Room 7 - Walk /n Closet (Average Load Procedure)
Room Length:
9.0
ft.
System Number"
1
Room Width:
6.4
ft.
Zone Number:
1
Area:
88.0
sq.ft.
Supply Air.
7
CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
0.9
AC/hr
Volume:
461.0
cu.ft.
Required Vent.:
0
CFM
Number of Registers:
1
Actual Winter Vent::
1
CFM
Runout Air.
_
0
CFM
Percent of Supply.:
19
%
Runout Duct Size:
4
in.
Actual Summer Vent.:
0
CFM
Runout Air Velocity:
79
ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
79
ft./min.
Actual Winter Infil.:
2
CFM
Actual Loss:
0.008
in.wg./100 ft.
Actual Summer Infil.:
1
CFM
Item
;Area -U-
Htg : San
Clg Let _ San
Descdiation "-
Quantity Value.
- ' HTM Loss
HTM - - -Gain Gain
Floor-22A-ph 6 ft.. Per.
6 1.358 40.7 244 0.0
0
0
Subtotals for Structure:
436
0
98
Infil.: Win.: 1.8, Sum.: 1.0
51 1.172 60 0.313
41
16
Room Totals:
667
41 151
Rhvac - Residential & Light Commercial HVAC Loads
Ken Humphrey
Elite Software DevelopmerM Inc.
WismerResidence
Port Saint Lucie, FL 34983.
Pane 15
Detailed Room. Loads - Room 8 - Bath 1 (Average Load Procedure
General
Calculation Mode:
Htg. & cig.
Occurrences:
1
Room Length:
9.5
ft.
System Number.
1
Room Width:
6.0
ft.
Zone Number:
1
Area:
57.0
sq.ft.
Supply Air:
13
CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
1.7
AC/hr
Volume:
456.0
cu.ft.
Required Vent.:
0
CFM
Number of Registers:_
— 1
Actual Winter Vent.:
3
CFM
Runout Air.
0
CFM
Percent of Supply.:
20
%
Runout Duct Size:
4
in.
Actual Summer Vent.:
1
CFM
Runout Air Velocity:
151
ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
151
ft./min.
Actual Winter Infil.:
2
CFM
Actual Loss:
0.027
in.wg./100 ft.
Actual Summer Infil.:
1
CFM
Item
Area -U-
! Htg,. ..Sen
Clg
Lat
Sen
Descri tion, -
Quantity,< _ Value
-`-- HTM- Loss
HTM
Gain
Gain
S -Wall-13A-5ocs 6.1 X 8
48.8 0.125
3.8 183
1.9
0
93
W -Part-15°/15°-12B-Osw 9.5 X 8
76 0.097
1.5 111
1.5
0
111
Floor-22A-ph 16 ft..Per.
16 1.358
40.7 662
0.0
0
0
Subtotals for Structure:
946
0
204
Infil.: Win.: 1.7, Sum.: 0.9
49
1.168 57
0.307
39
15
Ductwork:
347
71
Room Totals:
1,350
39
290
I Ken
Wismer
Detailed Room
Room Length:
Room Width:
Area:
Ceiling Height:
Volume:
Number of Registers:
Runout Air.
Runout Duct Size:
Runout Air Velocity:
Runout Air Velocity:
Actual Loss:
14.0
ft.
4.0
ft.
56.0
sq.ft.
8.0
ft.
448.0
cu.ft.
1
0
CFM
5
in.
626
ft./min.
626
ft./min.
0.322
in.wg./100 ft.
_Area _ ;.:-L
niianfity. vAil
System Number:
Zone Number.
Supply Air:
Supply Air Changes:
Required Vent.:
Actual -Winter Vent.:
Percent of Supply.:
Actual Summer Vent.:
Percent of Supply:
Actual Winter Infil.:
Actual Summer Infil.:
1
1
85
CFM
11.4
AC/hr
0
CFM
2
CFM
3
%
5
CFM
6
%
2
CFM
1
CFM
Clg. _
Let
HTM Gain -
NW-GIs-IOA-f shgc-0.45 0%S (2)
30 0.700 21.0 630 41.7
0
1,250
UP-Ceil-CustomRoofl 14 X 4
56 0.044 1.3 74 1.8
0
99
Subtotals for Structure:
802
0
1,399
Infil.: Win.: 2.0, Sum.: 1.1
56 1.179 66 0.321
45
18
Ductwork:
300
460
Room Totals:
1,168
45 1,877
W
Rhvac - Residential & Light Commercial HVAC Loads ���,
Elite Software Development, Inc.
Ken Humphrey
�7
Wismer Residence
Port Saint Lucie FL 34983
Page 17
Detailed Room Loads - Room 10 - Walk In Closet (Average Load Procedure
General
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
8.0 ft.
System Number.
1
Room Width:
8.0 ft.
Zone Number:
1
Area:
64.0 sq.ft.
Supply Air:
24 CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
2.8 AC/hr
Volume:
512.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
_
2 CFM
Runout Air:
0 CFM
Percent of Supply.:
8 %
Runout Duct Size:
4 in.
Actual Summer Vent.:
1 CFM
Runout Air Velocity:
274 ft./min.
Percent of Supply:
6 %
Runout Air Velocity:
274 ft./min.
Actual Winter Infil.:
5 CFM
Actual Loss:
0.087 in.wg./l00 ft.
Actual Summer Infil.:
2 CFM
Item _
Area, -U-
._. Htg San
Clg
Let
Sen,
Desceiption -
Quantity Value
HTM > -Loss•
HTM
Gain
Gain.
N -Wall-13A-5ocs 8 X 8
64 0.125
3.8 240
1.9
0
122
W -Wall-13A-5ocs 8 X 8
64 0.125
3.8 240
1.9
0
122
UP-Ceil-CustomRoofl 8 X 8
64 0.044
1.3 84
1.8
0
113
Subtotals for Structure:
564
0
357
Infil.: Win.: 4.6, Sum.: 2.5
128
1.172 150
0.313
102
40
Ductwork:
247
129
Room Totals:
961
102
526
Knvac- nesmenvarp ugnt commerciai nvwc LOWS ��� Elite Software Development, Inc.
Ken Humphrey �,7 Wismar Residence
Port Saint Lucie, FL 34983 Paoe 18
Detailed Room Loads - Room 11 - Stairway (Average Load Procedure
Room Length:
11.5
ft.
System Number.
1
Room Width:
3.5
ft.
Zone Number:
1
Area:
40.0
sq.ft.
Supply Alr:
4
CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
0.8
AC/hr
Volume:
322.0
cu.ft.
Required Vent.:
0
CFM
Number of Registers:
1
Actual Winter Vent.:
0
CFM
Runout Air: _ _ _
0
CFM
Percent of Supply.:
3
%
Runout Duct Size:
4
in.
Actual Summer Vent.:
0
CFM
Runout Air Velocity:
49
ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
49
ft./min.
Actual Winter Infil.:
0
CFM
Actual Loss:
0.003
In.wg./100 ft.
Actual Summer Infil.:
0
CFM
Subtotals for Structure: 53 0 71
Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0
Room Totals: 71 0 94
Knvac - tcemaenaai a ugnt UOmmerclal nvwc Loads Elite Sottware Development, Inc.
Ken Humphrey Wismer Residence
Port Saint Lucie, FL 34983 Pam 19
Detailed Room Loads - Room 12 - Master Bedroom (Average Load Procedure
Room Length:
18.5
ft.
System Number.
1
Room Width:
16.0
ft.
Zone Number.
1
Area:
296.0
sq.ft.
Supply Air:
201
CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
6.1
AC/hr
Volume:
2,368.0
cu.ft.
Required Vent.:
0
CFM
Number of Registers:-
2
Actual Winter Vent.:
7
CFM
Runout Air.0
CFM
Percent of Supply.:
3
%
Runout Duct Size:
6
in.
Actual Summer Vent.:
11
CFM
Runout Air Velocity:
512
ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
612
ft./min.
Actual Winter Infil.:
10
CFM
Actual Loss:
0.168
in.wg./100 ft.
Actual Summer Infil.:
5
CFM
Item ,— . i,Area -,--'�U- .. ,- Htg:Sen Clg Lat S ,n
De`scriiiod Quanti _ Value- .. HTM _- Loss _ HTM Gain Gain
W -Wall-I3A-5ocs 16.5 X 8 102 0.125 3.8 383 1.9 0 195
S -Wall-13A-5ocs 18.5 X 8
148
0.125 3.8
555
1.9
0
283
W -GIs-1A-hb-o shgc-0.52 16%S (2)
30
1.080 32.4
972
59.7
0
1,792
UP-Ceil-CustomRoofl 18.5 X 16
296
0.044 1.3
391
1.8
0
521
Subtotals for Structure:
2,301
0
2,791
Infil.: Win.: 10.0, Sum.: 6.4
280
1.175
329
0.314
223
88
Ductwork:
909
1,084
People: 200 lat/per, 230 sen/per.
2
400
460
Room Totals:
3,639
623
4,423
Rhvac - Residential & Light Commercial HVAC Loads
KenHumphreyWismar
Elite Software Development, Inc.
Residence
Port Saint Lucie FL 34983
Page 20
Detailed Room Loads - Room 13 - Master Bath (Average Load Procedure
General
Calculation Mode:
Htg. & cig.
Occurrences:
1
Room Length:
12.5 ft.
System Number.
1
Room Width:
6.5 ft.
Zone Number:
1
Area:
81.0 sq.ft.
Supply Air:
32
CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
2.9
AC/hr
Volume:
650.0 cu.ft.
Required Vent.:
0
CFM
Number of Registers:
1
Actual Winter Vent.:
2
CFM
Runout Air: - -
0 CFM
Percent of Supply.:
6
%
Runout Duct Size:
4 in.
Actual Summer Vent.:
2
CFM
Runout Air Velocity:
366 ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
366 ft./min.
Actual Winter Infil.:
3
CFM
Actual Loss:
0.153 in.wg./100 ft.
Actual Summer Infil.:
2
CFM
Item
Area
U --
_., ... , Htgc San
Clg
Let
San
Desch tion;;
Quanti
Value
-_ _ HTM '` Loss
HTM
Gain
N -Wall-13A-5ocs 12 X 8
89.1
0.125
3.8 334
1.9
0
170
N :GIs-lA-hb-o shgc-0.52 100%S
6.9
1.080
32.4 224
27.1
0
187
UP-Ceil-CustomRoofl 12.5 X 6.5
81.2
0.044
1.3 107
1.8
0
143
Subtotals for Structure:
685
0
500
Infil.: Win.: 3.4, Sum.: 1.8
96
1.177 113
0.313
76
30
Ductwork:
269
172
Room Totals:
1,047
76
702
Rhvac - Residential & Light Commercial HVAC Loads
Elite Software Development Inc.
Ken Humphrey
`
Wismar Residence
Port Saint Lucie FL 34983
Pa 21
Detailed Room Loads - Room 14 - Bedroom 2 (Average Load Procedure
General
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
12.5 ft.
System Number.
1
Room Width:
11.5 ft.
Zone Number.
1
Area:
144.0 sq.ft.
Supply Air.
52
CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
2.7
AC/hr
Volume:
1,150.0 cu.ft.
Required Vent.:
0
CFM
_
Number of Registers:
1
Actual Winter Vent.:
3
CFM
Runout Air - --
0 CFM
Percent of Supply.:
6
%
Runout Duct Size:
4 in.
Actual Summer Vent.:
3
CFM
Runout Air Velocity:
590 ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
590 ft./min.
Actual Winter Infil.:
4
CFM
Actual Loss:
0.392 in.wg./l00 ft.
Actual Summer Infil.:
2
CFM
Item .
Area ": U.
-„ .,. Htg ' .Sen
Clg
Lat
San
Descnptiom
Ouanti Value
HTM - - Loss
HTM
Gain
Gain
S -Wall-13A-5ocs 12.5 X 8
85 0.125
3.8 319
1.9
0
163
S -GIs-IA-hb-o shgC-0.52 100%S
15 1.080
32.4 486
27.1
0
407
UP-Ceil-CustomRoofl 12.5 X 11.5
143.8 0.044
1.3 190
1.8
0
253
Subtotals for Structure:
995
0
823
Infil.: Win.: 3.6, Sum.: 1.9
100
1.170 117
0.320
80
32
Ductwork:
384
278
Room Totals:
1,496
80
1,133
Rhvac - Residential& Light Commercial HVAC Loads Elite Software Development, Inc.
Ken Humphrey Warner Residence
Port Saint Lucie, FL 34983 Pana, 92
Room Length:
Room Width:
Area:
Ceiling Height:
Volume:
Number of Registers:
Runout Air.
Runout Duct Size:
Runout Air Velocity:
Runout Air Velocity:
Actual Loss:
- Room 15 -
9.5
ft.
8.0
ft.
76.0
sq.ft.
8.0
ft.
608.0
cu.ft.
1
0
CFM
4
in.
209
ft./min.
209
ft./min.
0.051
in.wg./100 ft.
System Number.,
Zone Number:
Supply Air.
Supply Air Changes:
Required Vent.:
Actual Winter Vent.:
Percent of Supply.:
Actual Summer Vent.:
Percent of Supply:
Actual Winter Infil.:
Actual Summer Infil.:
1
1
18 CFM
1.8 AC/hr
0 CFM_
1 CFM
7 %
1 CFM
6 %
3 CFM
1 CFM
item, Area ,U ... • Htg ; , Sen Cig Lat Sen
Description, Quantitw Value HTM Loss HTM Gain Gain
UP-Cell-CustomRoofl 9.5 X 8
76 0.044 1.3 100 1.8
0
134
Subtotals for Structure:
385
0
279
Infil.: Win.: 2.7, Sum.: 1.5
76 1.171 89 0.316
60
24
Room Totals: 638 60 401
Detailed Room Loads - Room 16 - Hall (Average Load Procedure
Room Length:
26.0
ft.
System Number.
1
Room Width:
4.0
ft.
Zone Number:
1
Area:
104.0
sq.ft.
Supply Air:
15
CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
1.1
AC/hr
Volume:
832.0
cu.ft.
Required Vent.:
0
CFM
Number of Registers:
1
Actual Winter Vent.:
1
CFM
Runout Air:
— ___ 0
CFM
Percent of Supply.:
5
%
Runout Duct Size:
4
in.
Actual Summer Vent.:
1
CFM
Runout Air Velocity:
175
ft./min.
Percent of Supply:
6
%
Runout Air Velocity:
175
ft./min.
Actual Winter Infil.:
1
CFM
Actual Loss:
0.037
in.wg./100 ft. Actual Summer Infil.:
1
CFM
Itema ,
w s -Area
U Htg tr , *r.Sen,
Clg .:Lat
. .__, Sen
Descriptions
Quantity b `:'
Value ==. %t HTM ' . Loss
HTM P ;Gain Gain
UP-Ceil-CustomRoofl 26 X 4 104 0.044 1.3 137 1.8 0 183
Subtotals for Structure: 257 0 244
Infil.: Win.: 1.1, Sum.: 0.6 32 1.188 38 0.313 25 10
Ductwork: 102 82
Room Totals: 397 25 336
Rhvac - Res identist R Light Commercial HVAC Loads
`�
Elite Software Development, Inc.
Ken Humphrey
Wismar Residence
Port Saint Lucie FL 34983
'Pace 24
Detailed Room Loads - Room 17 - Laund
(Average Load Procedure
General
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
11.0 ft.
System Number.
1
Room Width:
7.1 ft.
Zone Number.
1
Area:
78.0 sq.ft.
Supply Air:
56 CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
5.4 AC/hr
Volume:
625.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
2 CFM
Runout Air: -
0 CFM
Percent of Supply.:
3 %
Runout Duct Size:
4 in.
Actual Summer Vent.:
3 CFM
Runout Air Velocity:
643 ft./min.
Percent of Supply:
6 %
Runout Air Velocity:
643 ft./min.
Actual Winter Infil.:
2 CFM
Actual Loss:
0.464 in.wg./100 ft.
Actual Summer Infil.:
1 CFM
Item ..'_-_
Area
-U-
:,, Htg {. . ' -San
Clg
Let
Sen
Descri lion _ :
-QLia6tity
Value•-'<
HTM Loss
HTM
Gain
- =Gain
E -Wall-13A-5ocs 7 X 8
49.1
0.125
3.8 184
1.9
0
94
E -GIs-lA-hb-o shgc-0.52 27%S
6.9
1.080
32.4 224
55.4
0
382
UP-Cell-CustomRoofl 11 X 7.1
78.1
0.044
1.3 103
1.8
0
137
Subtotals for Structure:
511
0
613
Infrl.: Win.: 2.0, Sum.: 1.1
56
1.179 66
0.321
45
18
Ductwork:
199
302
Fquipment:
300
300
Room Totals:
776
345
1,233
Rhvac - Residential & Light Commercial HVAC Loads -
-
- Elite Software Development, Inc.
Ken Humphrey
Wismer Residence
Port Saint Lucie, FL 34983
Page 25
Detailed Room Loads - Room 18 - Walk In Closet 2 (Average
Load Procedure)
General
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
11.0 ft.
System Number.
1
Room Width:
7.4 ft.
Zone Number:
1
Area:
81.0 sq.ft.
Supply Air.
28 CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
2.6 AC/hr
Volume:
651.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
2 CFM
Runout Air:
0 CFM
Percent of Supply.:
8 %
Runout Duct Size:
4 in.
Actual Summer Vent.:
2 CFM
Runout Air Velocity:
325 ft./min.
Percent of Supply:
6 %
Runout Air Velocity:
325 ft./min.
Actual Winter Infil.:
5 CFM
Actual Loss:
0.121 in.wg./100 ft. Actual Summer Infil.:
3 CFM
Clg.
Lat ._'
. Sen
Descri tion�--
- Q'uanh . F '
- Value ` HTM'_'- '' Loss
HTM:"
-Gain
Gain
8 -Wall-13A-5ocs 7.4 X 8
59.2
0.125 3.8 222
1.9
0
113
E -Wall-I3A-5ocs 11 X 8
88
0.125 3.8 330
1.9
0
168
UP-Ceil-CustomRoof1 11 X 7.4
81.4
0.044 1.3 107
1.8
0
143
Subtotals for Structure:
659
0
424
Infil.: Win.: 5.2, Sum.: 2.8
147
1.175 173
0.319
117
47
Ductwork:
287
153
Room Totals:
1,119
117
624
System 1 Room Load Summa
. 'Htg Min
Run Run Cig Clg
-Min
Act'
Room Area Sens Htg
Duct, Duct Sens Lat
Cig
Sys,
No Name SF____ Btuh CFM
Size Val Btuh Btuh
CFM
CFM
-Zone 1-
._
1
Foyer
68
2,141
28
1-4
596
1,143
108
52
52-
2
Living
284
10,522
137
3-7
480
8,454
502
385
385w
3
Stairway
84
3,529
46
1-5
483
1,448
89
66
660
4
Kitchen
180
1,940
25-
1-6
467
2,015
715
92
92-
5
Dining
104
850
11
1-4
99
189
0
9
9-
6
Bedroom 1
132
2,975
39
1-5
646
1,935
546
88
88'
7
Walk In Closet
58
667
9
1-4
79
151
41
7
7-
8
Bath 1
57
1,350
18
1-4
151
290
39
13
13-
9
Bridge
56
1,168
15
1-5
626
1,877
45
85
85.
10
Walk In Closet
64
961
12
1-4
274
526
102
24
24'
11
Stairway
40
71
1
1-4
49
94
0
4
4-
12
Master Bedroom
296
3,539
46
2-6
512
4,423
623
201
201y
13
Master Bath
81
1,047
14
1-4
366
702
76
32
32p
14
Bedroom 2
144
1,496
19
1-4
590
1,133
80
52
52•
15
Bath 2
76
638
8
1-4
209
401
60
18
18,
16
Hall
104
397
5
1-4
175
336
25
15
15,
17
Laundry
78
776
10
1-4
643
1,233
345
56
56,
18
Walk In Closet
81
1,119
15
1-4
325
624
117
28
28%
Ventilation 2,275 1,137 2,864
Duct Latent 1,877
ystem 1 total 1,987 37,462 457 28,113 8,254 1,227 1,227
System 1 Main Trunk Size: 12x18 in.
Velocity: 818 ft./min
Loss per 100 ft.: 0.094 in.wg
Cooling System Summary
Cooling Sensible/Latent Sensible Latent Total
- -Tons .Rnlit. Rfijh RfnN.. Rf"h
Recommended: 3.12 75% /25% 28,113
Actual: 3.50 76%/24% 31,900
Type:
25HCA342A(
Model:
Brand:
CARRIER
Description:
HEAT PUMP
Efficiency:
HSPF 8.3
Sound:
Capacity:
40.5K BTU
Sensible Capacity:
n/a
Latent Capacity:
n/a
9,371 37,484
10,100 42,000
CARRIER
CENTRAL UNIT
14 SEER
42K BTU
31,900 Btuh
10,100 Btuh